At least 109 records · Page 6

Refinement and Modeling of a Blackbody-Based Calibration Method in the InfraBREAD Detector

The Broadband Reflector Experiment for Axion Detection (BREAD) is an ongoing experiment searching for the conversion of yet undiscovered axion-like dark matter particles to photons in the presence of a magnetic field. InfraBREAD, a sub-experiment of BREAD, uses a superconducting nanowire single photon detector (SNSPD), a high-efficiency and low-noise device, to specifically detect infrared-range photons produced by $\mathcal{O}$(eV) axion-like particles. The unique BREAD reflector setup allows for the focusing of all converted signal photons to a 1mm $\times$ 1mm SNSPD. However, when the detector is cooled to cryogenic temperatures during operation, uneven thermal contraction of reflector components may lead to a small shift in the location of the focal spot. A novel calibration method using blackbody radiation is proposed to locate the true focal spot of the detector \textit{in situ}. Through ray tracing simulations done in FRED Optical Engineering Software, this method is demonstrated to locate the focus to within 50 $\mu$m in three dimensions.

Rao, Shardul↗

Modeling and Proof-of-Concept of a Blackbody-Based Calibration Method in the InfraBREAD Detector

The Broadband Reflector Experiment for Axion Detection (BREAD) is an ongoing collaboration searching for the conversion of yet undiscovered axion-like dark matter particles to photons in the presence of a magnetic field. InfraBREAD, a pilot experiment realization of BREAD, uses a superconducting nanowire single photon detector (SNSPD), a high-efficiency and low-noise device, to specifically detect infrared-range photons produced by $\mathcal{O}$(eV) axion-like particles. The unique BREAD coaxial reflector setup allows for the focusing of converted signal photons to a 1mm $\times$ 1mm SNSPD. However, when the detector is cooled to cryogenic temperatures during operation, uneven thermal contraction of reflector components may lead to a small shift in the location of the focal spot. A novel calibration method using blackbody radiation is proposed to locate the true focal spot of the detector \textit{in situ}. Through ray tracing simulations done in FRED Optical Engineering Software, this method is demonstrated to locate the focus to within $\SI{50}{\micro\metre}$ in the axial dimension. Additionally, it is demonstrated that the blackbody photon source used in this calibration must be at a temperature of at least $\SI{15}{\kelvin}$ to $\SI{40}{\kelvin}$, depending on the sensitivity of the SNSPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unusually Strong Near‐Infrared Photoluminescence of Highly Transparent Bulk InSe Flakes

Abstract Bulk γ‐InSe has a direct bandgap of 1.24 eV, which corresponds to near infrared wavelengths ( λ = 1.0 µm) useful in optoelectronic applications from biometric detectors to silicon photonics. However, its potential for optoelectronic applications is largely untapped due in part to the lack of quantitative studies of its optical properties. Here, the unusually low absorptance and high photoluminescence quantum efficiency of single‐crystalline InSe flakes with thickness in the hundreds of nanometers are studied. InSe emits brightly at room temperature from its direct bandgap with a peak photoluminescence quantum yield (PLQY) of 20%, despite displaying indirect bandgap like low absorption coefficient due to the symmetry of its crystal structure. By performing pump‐dependent PLQY measurements, the radiative and nonradiative recombination coefficients are extracted, including the Shockley‐Read‐Hall and Auger coefficients. Finally, a proof‐of‐concept alternating current electroluminescent device at low temperature is demonstrated to show the promise of InSe in optoelectronic technology such as highly transparent, bright NIR light sources.

Geng, Jamie↗

Hyper-Raman spectroscopy of CeO 2

Cerium dioxide (CeO 2 ) belongs to the fluorite structure group (Oh 5 point group) resulting in one Raman active T 2g mode and two IR active T 1u TO and LO modes. The T 2g Raman band in CeO 2 has been used to probe the symmetric Ce-O vibrational mode of different sized nanoparticulates. Far infrared studies of the Ce-O interactions are difficult to conduct due to low optical transmission, efficiency of the detector and water absorption bands interfering with the measurements. The selection rules of hyper-Raman spectroscopy (HRS) allow the study of IR bands in the far infrared spectral region, such as the motion of the Ce atoms. For the first time, HRS was used to investigate the T 1u TO and LO IR modes in CeO 2 . The position and full-width half-maximum (FWHM) of the TO and LO bands in the HRS spectrum were used to investigate the spectral response in relation to particle size (i.e., phonon confinement). The investigation of CeO2 with HRS provides a research platform for future work in the study of ThO 2 , UO 2 and PuO 2 IR modes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Crosstalk Effects in Microwave SQUID Multiplexed TES Bolometer Readout

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, in this study, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Kilonova Detectability with Wide-Field Instruments [Slides]

A diverse set of instruments increase the chances of detecting and identifying a kilonova. Early observations increase the probability of detection. More sensitive wide-field ultraviolet instruments are needed as GW detectors reach design sensitivity. There is a dearth of wide-field infrared instruments. These results are useful for guiding kilonova searches following a GW detection and sGRD observation, proposals for time on current and upcoming instruments, and planning future wide-field instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

Kilonova Detectability with Wide-Field Instruments

A diverse set of instruments increase the chances of detecting and identifying a kilonova. Early observations increase the probability of detection. More sensitive wide-field ultraviolet instruments are needed as GW detectors reach design sensitivity. There is a dearth of wide-field infrared instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultrasensitive Room Temperature Infrared Photodetection Using a Narrow Bandgap Conjugated Polymer

Abstract Photodetectors operating across the short‐, mid‐, and long‐wave infrared (SWIR–LWIR, λ = 1–14 µm) underpin modern science, technology, and society in profound ways. Narrow bandgap semiconductors that form the basis for these devices require complex manufacturing, high costs, cooling, and lack compatibility with silicon electronics, attributes that remain prohibitive for their widespread usage and the development of emerging technologies. Here, a photoconductive detector, fabricated using a solution‐processed narrow bandgap conjugated polymer is demonstrated that enables charge carrier generation in the infrared and ultrasensitive SWIR–LWIR photodetection at room temperature. Devices demonstrate an ultralow electronic noise that enables outstanding performance from a simple, monolithic device enabling a high detectivity ( D *, the figure of merit for detector sensitivity) >2.44 × 10 9 Jones (cm Hz 1/2 W −1 ) using the ultralow flux of a blackbody that mirrors the background emission of objects. These attributes, ease of fabrication, low dark current characteristics, and highly sensitive operation overcome major limitations inherent within modern narrow–bandgap semiconductors, demonstrate practical utility, and suggest that uncooled detectivities superior to many inorganic devices can be achieved at high operating temperatures.

36 MATERIALS SCIENCE↗

Time-walk and jitter correction in SNSPDs at high count rates

Superconducting nanowire single-photon detectors (SNSPDs) are a leading detector type for time correlated single photon counting, especially in the near-infrared. When operated at high count rates, SNSPDs exhibit increased timing jitter caused by internal device properties and features of the RF amplification chain. Variations in RF pulse height and shape lead to variations in the latency of timing measurements. To compensate for this, we demonstrate a calibration method that correlates delays in detection events with the time elapsed between pulses. The increase in jitter at high rates can be largely canceled in software by applying corrections derived from the calibration process. We demonstrate our method with a single-pixel tungsten silicide SNSPD and show it decreases high count rate jitter. The technique is especially effective at removing a long tail that appears in the instrument response function at high count rates. At a count rate of 11.4 MCounts/s, we reduce the full width at 1% maximum level (FW1%M) by 45%. The method, therefore, enables certain quantum communication protocols that are rate-limited by the FW1%M metric to operate almost twice as fast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Redefining precision interferometry and spectroscopy with high-performance optical interference coatings

High-performance optical interference coatings have transformed precision interferometry and spectroscopy by enabling unparalleled control over light–matter interactions. This review explores recent innovations in ion-beam sputtered amorphous dielectric, as well as substrate-transferred crystalline coatings, and their impact on systems at the forefront of precision metrology. These state-of-the-art coating techniques generate multilayers with ultralow optical losses, yielding mirrors with exceptional reflectivity. Refinements in their noise performance push the ultimate limits of sensitivity, resolution, and stability in demanding laser-based metrology applications. These technologies underpin the most advanced timekeeping and spatial measurement tools, enabling high-finesse reference cavities for the world’s most precise optical atomic clocks and low-noise reflective test masses for km-baseline gravitational-wave detectors. Emerging hybrid designs combining these techniques expand access to the mid-infrared spectral region, enabling the first ultralow-optical-loss coatings in the 3000–5000 nm wavelength range for enhanced spectroscopy and trace-gas detection. We highlight how these technologies redefine coating performance metrics and set new benchmarks in quantum science, fundamental physics, and precision optical sensing.

Cole, Garrett D. [University of Arizona, Tucson, A↗

Shaping the Infrared luminescence of Colloidal Nanocrystals Using a Dielectric Microcavity

As they have gained maturity, colloidal nanocrystals (NCs) have also expand the spectral range over of which they could be used for photonic and optoelectronic applications. In particular, the infrared use of NCs has become of utmost interest to develop cost-effective alternatives to current technologies. It is then critical not to let the material dictate the light–matter interaction, which is why the coupling of NCs to photonic cavities has been proposed. For infrared NCs, this approach has first been devoted to the control of absorption with in mind the increase of the signal magnitude for detectors. A Lot of efforts have been focused on the use of metallic metasurfaces. However, these generate significant optical losses and yield low quality factor. Here, this study rather focus on the coupling of infrared NCs to a dielectric mirror cavity. HgTe/CdS core-shell NCs are used and integrated into a cavity made of aperiodic dielectric mirrors. The effect of the substrate is systematically study on spectral linewidth, carrier dynamic, and emission directivity. The cavity is shown to narrow the PL by a factor 10, while focusing the emission over a 12° angle. Monitoring the power dependence of the emission, this study shows that the cavity leads to 250 K increase in the effective electronic temperature.

36 MATERIALS SCIENCE↗

Large Adaptive Optics Survey for Substellar Objects around Young, Nearby, Low-mass Stars with Robo-AO

We present results from the Large Adaptive optics Survey for Substellar Objects, where the goal is to directly image new substellar companions (<70 M {sub Jup}) at wide orbital separations (≳50 au) around young (≲300 Myr), nearby (<100 pc), low-mass (≈0.1–0.8 M{sub ⊙}) stars. We report on 427 young stars imaged in the visible (i') and near-infrared (J or H ) simultaneously with Robo-AO on the Kitt Peak 2.1 m telescope and later the Maunakea University of Hawaii 2.2 m telescope. To undertake the observations, we commissioned a new infrared camera for Robo-AO that uses a low-noise high-speed SAPHIRA avalanche photodiode detector. We detected 121 companion candidates around 111 stars, of which 62 companions are physically associated based on Gaia DR2 parallaxes and proper motions, another 45 require follow-up observations to confirm physical association, and 14 are background objects. The companion separations range from 2 to 1101 au and reach contrast ratios of 7.7 mag in the near-infrared compared to the primary. The majority of confirmed and pending candidates are stellar companions, with ~5 being potentially substellar and requiring follow-up observations for confirmation. We also detected a 43 ± 9 M {sub Jup} and an 81 ± 5 M {sub Jup} companion that were previously reported. We found 34 of our targets have acceleration measurements detected using Hipparcos–Gaia proper motions. Of those, 58{sub -14}{sup +12}% of the 12 stars with imaged companion candidates have significant accelerations (χ{sup 2}>11.8), while only 23{sub -6}{sup +11}% of the remaining 22 stars with no detected companion have significant accelerations. The significance of the acceleration decreases with increasing companion separation. These young accelerating low-mass stars with companions will eventually yield dynamical masses with future orbit monitoring.

47 OTHER INSTRUMENTATION↗

Probing nanoparticle substrate interactions with synchrotron infrared nanospectroscopy: Coupling gold nanorod Fabry-Pérot resonances with SiO 2 and $h$-BN phonons

Spectroscopic interrogation of materials in the midinfrared with nanometer spatial resolution is inherently difficult due to the long wavelengths involved, reduced detector efficiencies, and limited availability of spectrally bright, coherent light sources. Technological advances are driving techniques that overcome these challenges, enabling material characterization in this relatively unexplored spectral regime. Synchrotron infrared nanospectroscopy (SINS) is an imaging technique that provides local sample information of nanoscale target specimens in an experimental energy window between 330 and 5000 cm -1 . Here, using SINS, we analyzed a series of individual gold nanorods patterned on a SiO 2 substrate and on a flake of hexagonal boron nitride. The SINS spectra reveal interactions between the nanorod photonic Fabry-Pérot resonances and the surface phonon polaritons of each substrate, which are characterized as avoided crossings. A coupled oscillator model of the hybrid system provides a deeper understanding of the coupling and provides a theoretical framework for future exploration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simons Observatory Microwave SQUID Multiplexing Readout: Cryogenic RF Amplifier and Coaxial Chain Design

The Simons Observatory (SO) is an upcoming polarization-sensitive cosmic microwave background experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of O(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of O(1000), microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that connects room temperature readout electronics to superconducting resonators that are coupled to transition edge sensor bolometers operating at sub-Kelvin temperatures. We describe design considerations including cryogenic RF component selection, system linearity, noise, and thermal power dissipation.

47 OTHER INSTRUMENTATION↗

Raman Wavelength Conversion in Ionic Liquids

Here, we explore the use of room-temperature ionic liquids (ILs) as Raman wavelength converters. ILs provide an engineerable framework to design suitable liquids for wavelength conversion over a broad spectral range, through careful selection of the molecular structures of the IL anions and cations so that specific characteristics can be obtained, such as a desirable Raman shift, low Brillouin scattering, and good optical transmission in the pump and Stokes wavelengths. Applying such criteria, we demonstrate that 1-ethyl-3-methylimidazolium dicyanamide (EMIM DCA) is an effective medium for conversion of 532-nm pulses from a Q-switched Nd :YAG laser to 603 nm. This corresponds to an approximate 2200 cm –1 shift, which can be used to generate mid-infrared radiation through subsequent difference frequency generation for optical pumping of CO 2 lasers. Threefold-higher Raman conversion efficiency is obtained in EMIM DCA compared with water under identical conditions in a proof-of-principle single-pass conversion setup, resulting in an efficient generation of multimillijoule, <6 ns duration, high-quality orange laser pulses in a wavelength region that is difficult to access at high energies. Consequently, we examine ILs representing two other classes of Raman-active functional groups and obtain conversion up to the fifth-order Stokes shift and first anti-Stokes shift. Through the tunable selection of their components and their useful dynamical properties, ILs provide a platform for efficient, simple, and alignment-tolerant high-energy Raman shifting with numerous industrial and technological applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

The right conditions for high-precision dynamic temperature and heat capacity measurement via pyrometry and conductivity

The pursuit of accurate bulk temperature T under extreme conditions has been a long-standing goal of the high pressure science community, complicated by a lack of data to inform models. To reach these extremely high-pressure, high-temperature (high P − T) conditions, a combination of dynamic and heated static experiments (e.g., diamond or gem anvil cel experiments) are used. For example, in a diamond anvil cell (DAC) experiment, a sample placed in the DAC is first pressurized. Following pressurization, the sample T is increased either by heating the entire DAC (usually using resistive heating, and limited to ∼1000K) or by applying intense laser power to the sample surfaces. In a dynamic experiment, the process of pressurizing the sample also heats it. In the case of shock physics experiments, such heating is substantial, easily reaching thousands of Kelvin; in our work we have seen T ∼17000K. Most methods of measuring temperature at ambient are not compatible with experiments under these high-pressure, high-temperature conditions: thermocouples break, melt, or have conductivity properties that differ from ambient where they are calibrated; thermometers would melt; both are too slow. As a result most methods are based on non-contact techniques such as x-ray diffraction broadening, neutron scattering, or optical methods. Of these, optical methods using the visible and near-infrared region of the spectrum are the most commonly used as the sources and detectors are readily available. In the case of optical methods the optical depth, and therefore the measurement location, is limited to the surface. When a window or anvil material is used, heat flows from the sample into the window/anvil. Likewise, if the sample undergoes a change in thermodynamic state, such as expansion upon release, different T may be expected. As a result, the surface or apparent temperature T app measurement will differ from the bulk or interior temperature that is desired. This surface measurement must be related to the bulk measurement using thermal transport models and material models. While it is tempting to conclude that one should just use x-ray methods that directly probe the interior, even these methods have been shown to depend on thermal transport and material models. Regardless of the method used to create the high P − T condition, therefore, we must understand the role of thermal transport and material models upon our interpretation of the T measurement, as well as the errors and uncertainties associated with the choice of models used in the analysis. This is a substantial area of research and this paper is by no means a complete survey of the relevant sources of uncertainty. For example, we have yet to begin to address alternate transport models in a detailed manner (e.g., Tan-Ahrens), or the many models that use additional layers to approximate melting, turbulence, or epitaxial phenomena). Likewise, we have not explored the impact upon uncertainty of thermal models that use temperature-dependent thermal transport coefficients, or the wide range of material models that can be applied. Instead, this paper focuses on using one simple model, the Urtiew-Grover model, to understand the sources of error in T measurement so that we may identify how best to focus future research efforts to return the best improvements and avoid working on over-optimizing a single type of measurement. To this end, we work through some of the best and worst case scenarios for T measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A search for optical and near-infrared counterparts of the compact binary merger GW190814

Here, we report on our observing campaign of the compact binary merger GW190814, detected by the Advanced LIGO and Advanced Virgo detectors on 2019 August 14. This signal has the best localization of any observed gravitational wave (GW) source, with a 90 per cent probability area of 18.5 deg 2 , and an estimated distance of ≈240 Mpc. We obtained wide-field observations with the Deca-Degree Optical Transient Imager (DDOTI) covering 88 per cent of the probability area down to a limiting magnitude of w = 19.9 AB. Nearby galaxies within the high probability region were targeted with the Lowell Discovery Telescope (LDT), whereas promising candidate counterparts were characterized through multicolour photometry with the Reionization and Transients InfraRed (RATIR) and spectroscopy with the Gran Telescopio de Canarias (GTC). We use our optical and near-infrared limits in conjunction with the upper limits obtained by the community to constrain the possible electromagnetic counterparts associated with the merger. A gamma-ray burst seen along its jet’s axis is disfavoured by the multiwavelength data set, whereas the presence of a burst seen at larger viewing angles is not well constrained. Although our observations are not sensitive to a kilonova similar to AT2017gfo, we can rule out high-mass (>0.1 M ⊙ ) fast-moving (mean velocity ≥0.3c) wind ejecta for a possible kilonova associated with this merger.