Search NASA⌕ Search

SEARCH · Search NASA

Results for “infrared reflectance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Iron oxide bands in the visible and near-infrared reflectance spectra of primitive asteroids

High resolution reflectance spectra of primitive asteroids (C, P, and D class and associated subclasses) have commonly revealed an absorption feature centered at 0.7 microns attributed to an Fe(2+)-Fe(3+) charge transfer transition in iron oxides and/or oxidized iron in phyllosilicates. A smaller feature identified at 0.43 microns has been attributed to an Fe(3+) spin-forbidden transition in iron oxides. In the spectra of the two main-belt primitive asteroids 368 Haidea (D) and 877 Walkure (F), weak absorption features which were centered near the location of 0.60-0.65 microns and 0.80-0.90 microns prompted a search for features at these wavelengths and an attempt to identify their origin(s). The CCD reflectance spectra obtained between 1982-1992 were reviewed for similar absorption features located near these wavelengths. The spectra of asteroids in which these absorption features have been identified are shown. These spectra are plotted in order of increasing heliocentric distance. No division of the asteroids by class has been attempted here (although the absence of these features in the anhydrous S-class asteroids, many of which have presumably undergone full heating and differentiation should be noted). For this study, each spectrum was treated as a continuum with discrete absorption features superimposed on it. For each object, a linear least squares fit to the data points defined a simple linear continuum. The linear continuum was then divided into each spectrum, thus removing the sloped continuum and permitting the intercomparison of residual spectral features.

Jarvis, Kandy S.↗

The Mars Underground Mole (MUM): A Subsurface Penetration Device with Infrared Reflectance and Raman Spectroscopic Sensing Capability

Searching for evidence of life on Mars will probably require access to the subsurface. The Martian surface is bathed in ultraviolet radiation which decomposes organic compounds, destroying possible evidence for life. Also, experiments performed by the Viking Landers imply the presence of several strongly oxidizing compounds at the Martian surface that may also play a role in destroying organic compounds near the surface. While liquid water is unstable on the Martian surface, and ice is unstable at the surface at low latitudes, recent results from the Mars Odyssey Gamma Ray Spectrometer experiment indicate that water ice is widely distributed near the surface under a thin cover of dry soil. Organic compounds created by an ancient Martian biosphere might be preserved in such ice-rich layers. Furthermore, accessing the subsurface provides a way to identify unique stratigraphy such as small-scale layering associated with lacustrine sediments. Subsurface access might also provide new insights into the Mars climate record that may be preserved in the Polar Layered Deposits. Recognizing the importance of accessing the subsurface of Mars to the future scientific exploration of the planet, the Mars Surveyor 2007 Science Definition Team called for drilling beneath the surface soils. Subsurface measurements are also cited as high priority in by MEPAG. Recognizing the importance of accessing the Martian subsurface to search for life, the European Space Agency has incorporated a small automated burrowing device called a subsurface penetrometer or Mole onto the Beagle 2 lander planned for 2003 launch. This device, called the Planetary Underground Tool (PLUTO), is a pointed slender cylinder 2 cm wide and 28 cm long equipped with a small sampling device at the pointed end that collects samples and brings them to the surface for analysis. Drawing on the PLUTO design, we are developing a larger Mole carrying sensors for identifying mineralogy, organic compounds, and water.

Stoker, C. R.↗

Capabilities and Limitations of Infrared Reflectance Microspectroscopy

Technological improvements in IR microspectroscopy have made it an increasingly appealing tool for planetary mineralogy. Microspectroscopy presents the prospect of examining small samples nondestructively and acquiring spectra that can be related to remote sensing observations. However, complications are introduced as a target beam size is reduced, and it is critical that limitations are understood. We present the results of a series of well constrained spectroscopic measurements, linking microspectroscopic data to traditionally collected reflectance spectra and petrologic information for the same rock.

Klima, R. L.↗

Conversion of Formic Acid on Single- and Nano-Crystalline Anatase TiO 2 (101)

Understanding thermochemical transformations of formic acid (FA) on metal oxide surfaces is important for many catalytical reactions. Here we study thermally induced reactions of FA on a single-crystalline and nanocrystalline anatase TiO 2 (101). We employ a combination of scanning tunneling microscopy (STM), temperature-programmed desorption (TPD), infrared reflection absorption spectroscopy (IRAS), diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS), and density functional theory (DFT) to follow the FA surface intermediates and reaction products above room temperature. We find that the primary reaction products desorbing at about 300, 480, and 515 K are molecular water, carbon monoxide, and formaldehyde, respectively. Bidentate (BD) formate and bridging hydroxyl (HO b ) are identified as central intermediates in the FA transformations. Bridging oxygen vacancies (V O ) are also likely participants despite their low stability at the surface. In conclusion, the parallel studies on single crystals and faceted TiO 2 (101) nanoparticles reveal the spectroscopic commonalities of surface species and of the thermal conversion of molecular and deprotonated forms of FA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multispectral remote sensing contribution to land surface evaporation

The global water cycle is perhaps the most important of all the biogeochemical cycles and evaporation, which is a significant component of the water cycle, is also linked with the energy and carbon cycles. Long-term evaporation over large areas has generally been computed as the difference of precipitation and river runoff. Analysis of short-term evaporation rate and its spatial pattern, however, is extremely complex, and multispectral remotely sensed data could aid in such analysis. Multispectral data considered here are visible and near-infrared reflectances, infrared surface temperature and the 37 GHz brightness temperatures. These observations are found to be not totally independent of each other. A few of their relationships are established and discussed considering physically-based models.

Choudhury, B. J.↗

Near infrared leaf reflectance modeling

Near infrared leaf reflectance modeling using Fresnel's equation (Kumar and Silva, 1973) and Snell's Law successfully approximated the spectral curve for a 0.25-mm turgid oak leaf lying on a Halon background. Calculations were made for ten interfaces, air-wax, wax-cellulose, cellulose-water, cellulose-air, air-water, and their inverses. A water path of 0.5 mm yielded acceptable results, and it was found that assignment of more weight to those interfaces involving air versus water or cellulose, and less to those involving wax, decreased the standard deviation of the error for all wavelengths. Data suggest that the air-cell interface is not the only important contributor to the overall reflectance of a leaf. Results also argue against the assertion that the near infrared plateau is a function of cell structure within the leaf.

Parrish, J. B.↗

Preliminary parameter studies to form pellets of hard materials for optical constants derived via single-angle reflectance spectroscopy

Infrared reflectance spectra can be influenced by many factors: the substrate and the thickness of the layer for liquids and the surface micromorphology, the form (powder, crystal) and the particle size for solids. All these parameters can play a role in the appearance of the measured spectrum. To avoid collecting multitudes of spectra to cover all such scenarios, the optical constants n and k, which are intrinsic properties of a material, can instead be used to model the reflectance spectrum. For solids, two techniques are often used to derive optical constants: ellipsometry and single-angle reflectance spectroscopy. For both methods, best results are usually obtained from single crystals. We have recently demonstrated for ammonium sulfate (a relatively soft material) that by optimizing certain conditions, high quality pellets with specularly reflective surfaces can be used in lieu of crystals. This was confirmed by the excellent agreement between the optical constants derived by these two methods. This work focuses on the possible extension of these methods to harder materials, starting with sodium sulfate. The first goal is to see if high quality pellet surfaces can be obtained as for ammonium sulfate. The reflectance values and the associated optical constants can also be obtained.

Diaz, Emmanuela↗

Spectral infrared hemispherical reflectance measurements for LDEF tray clamps

Infrared hemispherical reflectance measurements that were made on 58 chromic acid anodized tray clamps from LDEF are described. The measurements were made using a hemiellipsoidal mirror reflectometer with interferometer for wavelengths between 2-15 microns. The tray clamps investigated were from locations about the entire spacecraft and provided the opportunity for comparing the effects of atomic oxygen at each location. Results indicate there was essentially no dependence on atomic oxygen fluence for the surfaces studied, but there did appear to be a slight dependence on solar radiation exposure. The reflectances of the front sides of the tray clamps consistently were slightly higher than for the protected rear tray clamp surfaces.

Cromwell, B. K.↗

Spectral infrared hemispherical reflectance measurements for LDEF tray clamps

This paper describes infrared hemispherical reflectance measurements (2-15 microns) that were made on 58 chromic acid anodized tray clamps retrieved from the LDEF spacecraft. These clamps were used for maintaining the experiments in place and were located at various locations about the spacecraft. Changes in reflectance of the tray clamps at these locations were compared with atomic oxygen fluxes at the same locations. A decrease in absorption band depth was seen for the surfaces exposed to space indicating that there was some surface layer erosion. In all of the surfaces measured, little evidence of contamination was observed and none of the samples showed evidence of the brown nicotine stain that was so prominent in other experiments. Total emissivity values were calculated for both exposed and unexposed tray clamp surfaces. Only small differences, usually less than 1 percent, were observed. The spectral reflectances were measured using a hemi-ellipsoidal mirror reflectometer matched with an interferometer spectrometer. The rapid scanning capability of the interferometer allowed the reflectance measurements to be made in a timely fashion. The ellipsoidal mirror has its two foci separated by 2 inches and located on the major axis. A blackbody source was located at one focus while the tray clamp samples were located at the conjugate focus. The blackbody radiation was modulated and then focused by the ellipsoid onto the tray clamps. Radiation reflected from the tray clamp was sampled by the interferometer by viewing through a hole in the ellipsoid. A gold mirror (reflectance approximately 98 percent) was used as the reference surface.

Wood, Bobby E.↗

Infrared diffuse reflectance spectra of carbonaceous chondrites: Amount of hydrous minerals

Infrared diffuse reflectance spectra (2.53-25 microns) of some carbonaceous (C) chondrites were measured. The integrated intensity of the absorption bands near 3 microns caused by hydrous minerals were compared with the modal content of hydrous minerals for the meteorites. The CM and CI chondrites show larger values of the intergated intensity than those of the unique C chondrites Y82162, Y86720 and B7904, suggesting that the amount of hydrous minerals in the CM and CI chondrites is larger, which supports the contention that hydrous minerals were dehydrated by thermal metamorphism in the unique chondrites. Orgueil (CI) has the largest value of the integrated intensity among the C chondrites we measured and shows a sharp absorption band at 3685/cm (2.71 microns) that is not seen in the spectra of the CM chondrites. There is an excellent correlation between the observed hydrogen content in C chondrites and the integrated intensity. The CM chondrites show a wide variation in the strength of absorption bands at 1470/cm (6.8 microns), despite the similarity in absorption features near 3 micron for all CM chondites. The 1470/cm band could be due to the presence of some hydrocarbons but may also be a result of terrestrial alteration processes.

Miyamoto, M.↗

Anaysis of the quality of image data required by the LANDSAT-4 Thematic Mapper and Multispectral Scanner

The spatial, geometric, and radiometric qualities of LANDSAT 4 thematic mapper (TM) and multispectral scanner (MSS) data were evaluated by interpreting, through visual and computer means, film and digital products for selected agricultural and forest cover types in California. Multispectral analyses employing Bayesian maximum likelihood, discrete relaxation, and unsupervised clustering algorithms were used to compare the usefulness of TM and MSS data for discriminating individual cover types. Some of the significant results are as follows: (1) for maximizing the interpretability of agricultural and forest resources, TM color composites should contain spectral bands in the visible, near-reflectance infrared, and middle-reflectance infrared regions, namely TM 4 and TM % and must contain TM 4 in all cases even at the expense of excluding TM 5; (2) using enlarged TM film products, planimetric accuracy of mapped poins was within 91 meters (RMSE east) and 117 meters (RMSE north); (3) using TM digital products, planimetric accuracy of mapped points was within 12.0 meters (RMSE east) and 13.7 meters (RMSE north); and (4) applying a contextual classification algorithm to TM data provided classification accuracies competitive with Bayesian maximum likelihood.

Colwell, R. N.↗

Measuring near infrared spectral reflectance changes from water stressed conifer stands with AIS-2

Airborne Imaging Spectrometer-2 (AIS-2) data was acquired over two paired conifer stands for the purpose of detecting differences in spectral reflectance between stressed and natural canopies. Water stress was induced in a stand of Norway spruce and white pine by severing the sapwood near the ground. Water stress during the AIS flights was evaluated through shoot water potential and relative water content measurements. Preliminary analysis with raw AIS-2 data using SPAM indicates that there were small, inconsistent differences in absolute spectral reflectance in the near infrared 0.97 to 1.3 micron between the stressed and natural canopies.

Riggs, George↗

Near-infrared spectral reflectance of mineral mixtures - Systematic combinations of pyroxenes, olivine, and iron oxides

Near-infrared spectral reflectance data are presented for systematic variations in weight percent of two component mixtures of ferromagnesium and iron oxide minerals used to study the dark materials on Mars. Olivine spectral features are greatly reduced in contrast by admixture of other phases but remain distinctive even for low olivine contents. Clinopyroxene and orthopyroxene mixtures show resolved pyroxene absorptions near 2 microns. Limonite greatly modifies pyroxene and olivine reflectance, but does not fully eliminate distinctive spectral characteristics. Using only spectral data in the 1 micron region, it is difficult to differentiate orthopyroxene and limonite in a mixture. All composite mineral absorptions were either weaker than or intermediate in strength to the end-member absorptions and have bandwidths greater than or equal to those for the end members. In general, spectral properties in an intimate mixture combine in a complex, nonadditive manner, with features demonstrating a regular but usually nonlinear variation as a function of end-member phase proportions.

Singer, R. B.↗

Infrared and Reflected Solar Radiation Measurements from the TIROS 2 Meteorological Satellite

TIROS II contains instrumentation for measuring infrared and reflected solar radiation from the earth and its atmosphere. A medium resolution scanning radiometer and a low resolution non-scanning radiometer are employed. The satellite's spin provides the scan line of the medium resolution radiometer which is then advanced by the orbital motion. The spatial resolution is about 40 miles square when the earth directly beneath the satellite is viewed. The five channels employ bolometer detectors and filters to limit the spectral responses to five bands: 6 to 6.5 microns, 8 to 12 microns, 0.2 to 6 microns, 8 to 30 microns, and 0.55 to 0.75 microns. These five bands study, respectively: radiation in the water vapor absorption band; day and nighttime cloud cover; albedo; thermal radiation; and visual maps for comparison with satellite vidicon pictures. The low resolution non-scanning radiometer measures the earth's black-body temperature and albedo. Its field when viewing directly below is a circle of 450 miles diameter, covering part of each frame from the wide-field television camera. This radiometer consists of two thermistors, each in the apex of a reflective cone which provides optical gain. One thermistor is black and responds to both thermal and reflected solar radiation. The second responds to thermal but reflects solar radiation. The design, calibration, performance, and data reduction for both systems are discussed herein.

Bandeen, W. R.↗

Infrared fluorescent coatings

The present invention provides for a composition comprising a pigment, wherein the composition is suitable for coating a surface that is, or is expected to be, exposed to the sun. The pigment comprises particles that fluoresce in sunlight, thereby remaining cooler in the sun than coatings pigmented with non-fluorescent particles. The particles comprise solids that fluoresce or glow in the visible or near infrared (NIR) spectra, or that fluoresce when doped. Suitable dopants include, but are not limited to, ions of rare earths and transition metals. A coating composition includes: (i) a film-forming resin; (ii) an infrared reflective pigment; and (iii) an infrared fluorescent pigment different from the infrared reflective pigment. When the coating composition is cured to form a coating and exposed to radiation comprising fluorescence-exciting radiation, the coating has a greater effective solar reflectance (ESR) compared to the same coating exposed to the radiation comprising fluorescence-exciting radiation except without the infrared fluorescent pigment. A multi-layer coating including the coating composition, and a substrate at least partially coated with the coating composition is also disclosed. A method of reducing temperature of an article includes applying the coating composition to at least a portion of the article.

Zalich, Michael Andrew↗

Infrared fluorescent coating compositions

A coating composition includes: (i) a film-forming resin; (ii) an infrared reflective pigment; and (iii) an infrared fluorescent pigment different from the infrared reflective pigment. When the coating composition is cured to form a coating and exposed to radiation comprising fluorescence-exciting radiation, the coating has a greater effective solar reflectance (ESR) compared to the same coating exposed to the radiation comprising fluorescence-exciting radiation except without the infrared fluorescent pigment. A multi-layer coating including the coating composition, and a substrate at least partially coated with the coating composition is also disclosed. A method of reducing temperature of an article includes applying the coating composition to at least a portion of the article.

Zalich, Michael A.↗

Infrared fluorescent coatings

The present invention provides for a composition comprising a pigment, wherein the composition is suitable for coating a surface that is, or is expected to be, exposed to the sun. The pigment comprises particles that fluoresce in sunlight, thereby remaining cooler in the sun than coatings pigmented with non-fluorescent particles. The particles comprise solids that fluoresce or glow in the visible or near infrared (NIR) spectra, or that fluoresce when doped. Suitable dopants include, but are not limited to, ions of rare earths and transition metals. A coating composition includes: (i) a film-forming resin; (ii) an infrared reflective pigment; and (iii) an infrared fluorescent pigment different from the infrared reflective pigment. When the coating composition is cured to form a coating and exposed to radiation comprising fluorescence-exciting radiation, the coating has a greater effective solar reflectance (ESR) compared to the same coating exposed to the radiation comprising fluorescence-exciting radiation except without the infrared fluorescent pigment. A multi-layer coating including the coating composition, and a substrate at least partially coated with the coating composition is also disclosed. A method of reducing temperature of an article includes applying the coating composition to at least a portion of the article.

Zalich, Michael Andrew↗