Search NASA⌕ Search

SEARCH · Search NASA

Results for “inline”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

103 records · Page 6

Progress on Ares First Stage Propulsion

The mission of the National Aeronautics and Space Administration (NASA) is not simply to maintain its current position with the International Space Station and other space exploration endeavors, but to build a permanent outpost on the Moon and then travel on to explore ever more distant terrains. The Constellation Program will oversee the development of the crew capsule, launch vehicles, and other systems needed to achieve this mission. From this initiative will come two new launch vehicles: the Ares I and Ares V. The Ares I will be a human-rated vehicle, which will be used for crew transport; the Ares V, a cargo transport vehicle, will be the largest launch vehicle ever built. The Ares Projects team at Marshall Space Flight Center (MSFC) in Huntsville, Alabama is assigned with developing these two new vehicles. The Ares I vehicle will have an inline, two-stage rocket configuration. The first stage will provide the thrust or propulsion component for the Ares rocket systems through the first two minutes of the mission. The First Stage Team is tasked with developing the propulsion system necessary to liftoff from the Earth and loft the entire Ares vehicle stack toward low-Earth orbit. Building on the legacy of the Space Shuttle and other NASA space exploration initiatives, the propulsion for the Ares I First Stage will be a Shuttle-derived reusable solid rocket motor. Progress to date by the First Stage Team has been robust and on schedule. This paper provides an update on the design and development of the Ares First Stage Propulsion system. The presentation provides an overview of the information presented in the paper.

Priskos, Alex S.↗

Two-Speed Rotorcraft Research Transmission Power-Loss Associated with the Lubrication and Hydraulic Rotating Feed-Through Design Feature

An investigation was completed into the power loss associated with a rotating feed-through (RFT) design feature used to transfer lubrication and a hydraulic control signal from the static reference frame to a rotating reference frame in the NASA GRC two-speed transmission tests conducted in the Variable-Speed Drive Test Rig. The RFT feature, not commercially available, was created specifically for this research project and is integral to all two-speed transmission configurations tested, as well as a variant concept design for a geared variable-speed transmission presented at AHS Forum 71 in 2015. The experimental set-up and results from measurements in the isolated rotating-feed-through (RFT) experiments are presented. Results were used in an overall power loss assessment for a scaled conceptual 1,000 horsepower inline concentric two-speed transmission to support a NASA Revolutionary Vertical Lift Technologies (RVLT) Technical Challenge, demonstrating 50% speed change with less than 2% power loss while maintaining current power-to-weight ratios.

Rotorcraft↗

Two-Speed Rotorcraft Research Transmission Power-Loss Associated with the Lubrication and Hydraulic Rotating Feed-Through Design Feature

An investigation was completed into the power loss associated with a rotating feed-through (RFT) design feature used to transfer lubrication and a hydraulic control signal from the static reference frame to a rotating reference frame in the NASA GRC two-speed transmission tests conducted in the Variable-Speed Drive Test Rig. The RFT feature, not commercially available, was created specifically for this research project and is integral to all two-speed transmission configurations tested, as well as a variant concept design for a geared variable-speed transmission presented at AHS Forum 71 in 2015. The experimental set-up and results from measurements in the isolated rotating-feed-through (RFT) experiments are presented. Results were used in an overall power loss assessment for a scaled conceptual 1,000 horsepower inline concentric two-speed transmission to support a NASA Revolutionary Vertical Lift Technologies (RVLT) Technical Challenge, demonstrating 50% speed change with less than 2% power loss while maintaining current power-to-weight ratios.

Rotorcraft↗

Two-Speed Rotorcraft Research Transmission Power-Loss Associated with the Lubrication and Hydraulic Rotating Feed-Through Design Feature

An investigation was completed into the power loss associated with a rotating feed-through (RFT) design feature used to transfer lubrication and a hydraulic control signal from the static reference frame to a rotating reference frame in the NASA GRC two-speed transmission tests conducted in the Variable-Speed Drive Test Rig. The RFT feature, not commercially available, was created specifically for this research project and is integral to all two-speed transmission configurations tested, as well as a variant concept design for a geared variable-speed transmission presented at AHS Forum 71 in 2015. The experimental set-up and results from measurements in the isolated rotating-feed-through (RFT) experiments are presented. Results were used in an overall power loss assessment for a scaled conceptual 1,000 horsepower inline concentric two-speed transmission to support a NASA Revolutionary Vertical Lift Technologies (RVLT) Technical Challenge, demonstrating 50% speed change with less than 2% power loss while maintaining current power-to-weight ratios.

Rotorcraft↗

Thermal Model of a Zero Boil Off System for the Nuclear Thermal Propulsion System

NASA is currently developing an updated concept for a nuclear thermal propulsion (NTP) system. To enable this concept, efficient thermal insulation and cryocooler heat exchanger systems are required to eliminate boil-off of propellant. This paper presents the results of a thermal model used to assess the feasibility of using active cooling with a tube-on-tank heat exchanger configuration for the inline tank of the NTP system. Results show that: cryocooler working fluid temperature and mass flow rate can be adjusted to achieve zero boil off (ZBO) with broad area cooling, over-sizing the cryocooler lift directly translates into a reduction in tank pressure, and broad area cooling may still maintain ZBO despite the reduced heat transfer between tank wall and propellant that is expected in reduced gravity.

zero boil off↗

Scroll Pump Dust Tolerance Test for Martian Atomospheric Acquisition

The ability to generate oxygen on the Martian surface will be essential to establishing a human presence on Mars. Flow generating devices such as pumps, compressors, and blowers will be essential components in Martian atmospheric acquisition and processing systems that need to work reliably during the mission duration. A concern with the reliability of the system is its ability to continue to perform nominally when Martian dust, if it bypasses the inlet filter, enters into the system. A series of tests were conducted to simulate the ingesting of Martian dust on a small scroll pump, similar to the one used on the MOXIE payload, during its pumping operation. The inlet of the pump was connected to a large volume closed-loop pipe system, known as the Mars Atmospheric Flow Loop, containing pure CO2 gas at a Martian pressure of 7 Torr. A length of stainless steel tubing was extended from the inlet port of scroll pump, which was mounted outside the flow loop, to the inside volume of the flow loop using a feed-through compression fitting. A steady low-speed flow was generated inside the flow loop to continuously disperse and transport the dust toward the inlet tubing. JSC-Mars 1 Martian simulant was used to challenge the pump. The pump performance parameters such as flow rate, pump speed, pressures and temperature were monitored during these tests. Samples of the dust entering the pump inlet were taken prior to exposure tests, using an inline filter element to determine the rate of dust ingestion into the internal components of the pump. After two tests with exposure times of the order of 60 minutes, the data indicated that small changes in pump performance took place under high rates of dust exposure.

scroll pump↗

Assessment of Holographic Microscopy for Quantifying Marine Particle Size and Concentration

Holographic microscopy has emerged as a tool for in situ imaging of microscopic organisms and other particles in the marine environment: appealing because of relatively larger sampling volumes and simpler optical configurations compared to similar imaging systems. However, its quantitative capabilities have remained uncertain, in part because hologram reconstruction and image recognition have required manual operation. Here we assess the quantitative skill of our automated hologram processing pipeline, the CCV Pipeline, to evaluate the size and concentration measurements of environmental and cultured assemblages of marine plankton particles, and microspheres. Over one-million particles, ranging from 10-200 microns equivalent spherical diameter (ESD), imaged by the 4-Deep HoloSea digital inline holographic microscope (DIHM) are analyzed. These measurements were collected in parallel with FlowCam, Imaging FlowCytobot, and manual microscope identification. Once corrections for particle location and nonuniform illumination were developed and applied, the DIHM showed an underestimate in ESD of about 3-10%, but successfully reproduced the size-spectral-slope from environmental samples, and the size distribution of monocultures and microspheres. DIHM concentrations (order 1-1000 particles~ml-1) showed linear agreement (r^2=0.73) with the other instruments, but individual comparisons at times had large uncertainty.

holograpy↗

Assessment of holographic microscopy for quantifying marine particle size and concentration

Holographic microscopy has emerged as a tool for in situ imaging of microscopic organisms and other particles in the marine environment: appealing because of the relatively larger sampling volume and simpler optical configuration compared to other imaging systems. However, its quantitative capabilities have so far remained uncertain, in part because hologram reconstruction and image recognition have required manual operation. Here, we assess the quantitative skill of our automated hologram processing pipeline (CCV Pipeline), to evaluate the size and concentration measurements of environmental and cultured assemblages of marine plankton particles, and microspheres. Over 1 million particles, ranging from 10 to 200 μm in equivalent spherical diameter, imaged by the 4‐Deep HoloSea digital inline holographic microscope (DIHM) are analyzed. These measurements were collected in parallel with a FlowCam (FC), Imaging FlowCytobot (IFCB), and manual microscope identification. Once corrections for particle location and nonuniform illumination were developed and applied, the DIHM showed an underestimate in ESD of about 3% to 10%, but successfully reproduced the size spectral slope from environmental samples, and the size distribution of cultures (Dunaliella tertiolecta, Heterosigma akashiwo, and Prorocentrum micans) and microspheres. DIHM concentrations (order 1 to 1000 particles ml(exp −1)) showed a linear agreement (r(exp 2) = 0.73) with the other instruments, but individual comparisons at times had large uncertainty. Overall, we found the DIHM and the CCV Pipeline required extensive manual correction, but once corrected, provided concentration and size estimates comparable to the other imaging systems assessed in this study. Holographic cameras are mechanically simple, autonomous, can operate at very high pressures, and provide a larger sampling volume than comparable lens‐based tools. Thus, we anticipate that these characterization efforts will be rewarded with novel discovery in new oceanic environments.

Noah L. Walcutt↗

Architecture for Space-Based Exoplanet Spectroscopy in Mid-Infrared

Characterizing exoearths at wavelength about 10 micron offers many benefits over visible coronagraphy. Apart from providing direct access to a number of significant bio-signatures, direct-imaging in the mid-infrared can provides 1000 times or more relaxation to contrast requirements while greatly shortening the time-scales over which the system must be stable. This in-turn enables tremendous relief to optical manufacturing, control and stability tolerances bringing them inline with current technology state of the art. In this paper, we explore a reference design that co-optimizes a large segmented linearized aperture telescope with one-dimensional phase-induced aperture apodization providing high-contrast imaging for spectroscopic analysis. By rotating about a parent star, the chemical signatures of its planets are characterized while affording additional means for background suppression.

Vasisht, Gautam↗

Scroll Pump Dust Tolerance Test for Martian Atmospheric Acquisition

The ability to generate oxygen on the Martian surface will be essential to establishing a human presence on Mars. Flow generating devices such as pumps, compressors, and blowers will be crucial components in Martian atmospheric acquisition and processing systems that need to work reliably during the mission duration. A concern with the reliability of the system is its ability to continue to perform nominally when Martian dust, if it bypasses the inlet filter, enters into the system. A series of tests were conducted to simulate the ingestion of Martian dust on a small scroll pump, similar to the one used on the MOXIE payload. The inlet of the pump was connected to a large volume closed-loop pipe system, known as the Mars Atmospheric Flow Loop, containing pure CO2 gas at a Martian pressure of 7 Torr. A length of stainless steel tubing was extended from the inlet port of scroll pump, which was mounted outside the flow loop, to the inside volume of the flow loop using a feed-through compression fitting. A steady low-speed flow was generated inside the flow loop to continuously disperse and transport the dust toward the inlet tubing. JSC-Mars 1 Martian simulant was used to challenge the pump. Pump performance parameters such as flow rate, pump speed, pressure and temperature were monitored during these tests. Samples of the dust entering the pump inlet were taken prior to the exposure tests, using an inline filter element to determine the rate of dust ingestion into the internal components of the pump. After two tests with exposure times of one hour, the data indicated that small changes in pump performance took place under high rates of dust exposure.

Martian Atmospheric↗

Feasibility Analysis of Unmanned Aerial Vehicle Based on Tensegrity Structure

For future unmanned aerial vehicles to be ubiquitous, they need to be safe to other aircraft and people on the ground even in the event of unintended collisions. Unfortunately, this is difficult for current rigid designs as a crash of all but the smallest aircraft will have a significant impact on its target. As an alternative, this pa-per explores using a soft tensegrity structure (interconnected cables and rods) as a lightweight, robust chassis for a UAS and analyze its ability to achieve stable, controllable flight and mitigate damage during a collision. Tensegrity structures are three dimensional geometric constructions which are able to undergo severe deformations without permanent damage, and can immediately return to their original shape. Experiments and analysis are performed using a simple physics simulation environment, allowing for rapid design iteration and thorough exploration of system behavior. We test multiple configurations of the vehicle to understand impacts of changing various physical characteristics, and take limitations such as modern propeller thrust coefficients and motor speeds into account to ensure our results are inline with those of a real world vehicle. We ultimately find that such a vehicle has considerable real world potential, and that a physical prototype could theoretically be constructed and flown with current technology.

Bjorn Johnson↗

Venous Gas Embolism: Review to Quantify a Safe Volume of Air in Intravenous Fluids Bags for Spaceflight Applications

INTRODUCTION: The ability to create intravenous fluids (IVF) in-situ from the potable water supply of a spaceflight vehicle or habitat is a desired capability for an exploration medical system. In order to define an acceptable volume of air in IVF bags, an understanding of the volume of venous gas embolism as it relates to negative outcomes is needed. The purpose of this study is to review the literature to determine if there is a known volume of gas that contributes to mortality and/or morbidity that could be used to define requirements for rapid IVF infusion in microgravity. METHODS: A literature review was conducted of the PubMed database using the syntax: (Venous) AND (Gas OR Air) AND (Embolism) AND (Morbidity) AND (Mortality) AND (Volume) as well as manual review of references from relevant articles. 151 articles were screened excluding partial text and pediatric articles. Studies were reviewed for identification of volume of venous gas embolism associated with morbidity and/or mortality, which identified 27 articles. RESULTS: Reviewed literature included animal studies, case reports, and review articles. A high variation of proposed volumes contributing to mortality was reported. The limited human data values ranged from 20 ml to 200 ml of infused air with mortality estimated to be 48 – 80%. No studies evaluated human morbidity in any capacity. DISCUSSION: The lack of consensus on the safe volume of infused air has potential ramifications for IVF use in spaceflight as current technologies to create IVF from potable water may introduce air in IVF bags. While current microgravity infusion protocols call for the use of inline air removal filters, commercially available options have flow rate limitations that preclude rapid infusion in a resuscitation scenario. Such filters may be used in parallel to increase flow rate, but the time required to set up such a system may exclude its use during a medical emergency. Additionally, these consumable filters drive up the overall mass and volume of the medical system. Identification of a safe volume of air in IVF would allow for guidelines for the in-situ production of IVF in future spaceflight vehicles/habitats.

Christopher R Woodard↗

Comprehensive Digital Twin of a Macro-fluidic Electrochemical Reactor to Optimize the Electrochemical-based Recovery of O2 from Metabolic CO2

Future long-duration missions will require a sustainable and efficient system capable of yielding a minimum of 75% O 2 recovery from metabolic CO 2 to achieve self-sufficiency for long space missions beyond Earth's low orbit. A Macro-fluidic Electrochemical Reactor (MFECR) development effort to electrochemically recover O 2 from CO 2 is underway at NASA Marshall Space Flight Center (MSFC) to increase current O 2 recovery efficiency and reduce air revitalization (AR) system complexity at the International Space Station (ISS) habitat and future long missions. The authors have developed and deployed a digital twin of an actual single cell of the MFECR via a comprehensive 3D multiphysics model that thoroughly replicates the exact configuration and fluid/material domains of the MFECR. This model's electrochemical physics consists of multicomponent-multiphase electrochemical-driven reactions leading to CO 2 conversion to C 2 H 4 and CO along with the formation of H 2 on the cathode in parallel with the generation of O 2 and H 2 O on the anode. This electrochemical model is coupled with all the physics phenomena involved in the process, including but not limited to fluid and non-ideal mass transfer of reactant and product species in free and porous media, convective/conduction/radiative heat transfer, and conduction of DC electrical current with Joule heating generation. The digital twin has proved to be an essential tool for performing different qualitative studies, including the effect of reducing the height (increasing the respect ratio) of the serpentine walls, leading to a further redesign of the EDU (the newly redesigned MFECR EDU has been fabricated and is expected to be used in future tests), the evaluation of setting different MFECRs connected in series, and the assessment of feeding air directly to the MFECR skipping the preceding metabolic CO 2 separation from air. The MFECR's test stand is fully automated and equipped with several inline measurements (flow, pressure, temperature, pH, component concentration) systems on all six MFECR's IO streams, allowing reliable experimental validation of the model, parametric determination of all electrochemical reactions, and process optimization.

Jesus A Dominguez↗