Search NASA⌕ Search

SEARCH · Search NASA

Results for “insert magnet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Single Crystals of Vanadium Oxides as a Lens for Understanding Structural and Electronic Phase Transformations, Ion Transport, Chemo-Mechanical Coupling, and Electrothermal Neuronal Emulation

Vanadium oxides cystallize in a diverse array of structures and compositions arising from the redox versatility of vanadium, variable covalency of V−O bonds, and myriad coordination geometries. Their open frameworks present abundant interstitial sites that enable insertion of guest-ions. In such compounds, V3d electron and spin localization and disorder couple strongly to structural preferences. The rich structural diversity manifests as a “rugged” free energy landscape with multiple interconvertible polymorphs. Such a landscape sets up structural, electronic, and magnetic transitions that underpin the promise of these materials as ion-insertion battery electrodes; compact primitives for brain-inspired computing, and heterogeneous catalysts. Here, we examine the structural and compositional diversity, electronic instabilities, defect dynamics, structure transformations, mechanical properties, and surface structure of vanadium oxides using single crystals as a distinctive lens. Single crystals enable the measurement of structure−function correlations without the ensemble and orientational averaging inevitable in polycrystalline materials. Their well-defined surfaces further enable examination of facet-dependent reactivity toward molecular adsorbates, ion fluxes, and lattice (mis)matched solids. We provide a comprehensive account of vanadium-oxide single-crystal studies, from delineation of common structural motifs to single-crystal growth techniques, topochemical modification strategies, mechanisms underpinning electronic instabilities, and implementation as electrothermal neurons and battery electrode materials.

Ponis, John [Texas A&M University, College Station↗

Piezo-Operated Shutter Mechanism Moves 1.5 cm

The figure shows parts of a shutter mechanism designed to satisfy a number of requirements specific to its original intended application as a component of an atomic clock to be flown in outer space. The mechanism may also be suitable for use in laboratory and industrial vacuum systems on Earth for which there are similar requirements. The requirements include the following: a) To alternately close, then open, a 1.5-cm-diameter optical aperture twice per second, with a stroke time of no more than 15 ms, during a total operational lifetime of at least a year; b) To attenuate light by a factor of at least 1012 when in the closed position; c) To generate little or no magnetic field; d) To be capable of withstanding bakeout at a temperature of 200 C to minimize outgassing during subsequent operation in an ultrahigh vacuum; and e) To fit within a diameter of 12 in. (=305 mm) a size limit dictated by the size of an associated magnetic shield. The light-attenuation requirement is satisfied by use of overlapping shutter blades. The closure of the aperture involves, among other things, insertion of a single shutter blade between a pair of shutter blades. The requirement to minimize the magnetic field is satisfied by use of piezoelectric actuators. Because piezoelectric actuators cannot withstand bakeout, they must be mounted outside the vacuum chamber, and, hence, motion must be transmitted from the actuators to the shutter levers via a vacuum-chamber-wall diaphragm.

Glaser, Robert↗

Visible optical isolator using ZnSe

A compact Faraday effect optical isolator was constructed for visible wavelengths and tested at 5145 A. The nonreciprocal element of the isolator was polycrystalline zinc selenide placed in the magnetic field of a permanent magnet. For 5145 A the isolator had a 2.06-dB insertion loss and a 25.5-dB isolation. Indices of refraction and Verdet constants were measured for zinc selenide in the wavelength region from 4700 to 6300 A.

Wunderlich, J. A.↗

Properties of large nearly perfect crystals at very low temperatures

A liquid helium cryostat of a size and construction unavailable commercially, was built for use in measuring the Q of several materials at milli-Kelvin temperatures. The design and testing of the cryostat is described as well as the design of the experiment vacuum chamber and adaptor for the dilution refrigerator insert. Theory, design, and testing are also discussed for the magnetic coils built to levitate the materials so as to isolate them and increase the measured Q. A four point suspension with capacitor end plates as the transducer was used to obtain preliminary Q measurements of 6061 aluminum alloy and single crystal silicon. Results are tabulated.

Davis, W.↗

Flexible Interior-Impression-Molding Tray

Device used inside combustion chamber of complicated shape for nondestructive evaluation of qualities of welds, including such features as offset, warping, misalignment of parts, and dropthrough. Includes flexible polypropylene tray trimmed to fit desired interior surface contour. Two neodymium boron magnets and inflatable bladder attached to tray. Tray and putty inserted in cavity to make mold of interior surface.

Anders, Jeffrey E.↗

Overview of NASA's Microgravity Materials Program

The NASA Microgravity Materials Program currently funds 19 grants involving the development of experiments to be conducted on the International Space Station (ISS). These experiments are designed to utilize facilities built by partner agencies, primarily the European Space Agency. These facilities include furnace inserts to the Materials Science Research Rack, the Electro-Magnetic Levitator, and the Device for the study of Critical Liquids and Crystallization (DECLIC) facility. Projects are funded either through proposals responding to NASA announcements or unsolicited proposals associated with an international collaboration that is partially funded by a partner agency. An overview of the research content of the program, how potential investigations are solicited, reviewed and funded, and the operations of the ISS facilities is provided.

Downey, James Patton↗

High current, high-temperature operation test of the superconducting magnets in the RHIC yellow ring

We report on the tests conducted at the end of RHIC Run 21 to evaluate the operation of superconducting magnets in the RHIC yellow ring at higher currents – up to 5500 A for the arc dipoles and all other magnets on the dipole bus and the focusing arc quadrupoles, up to 5750 A for defocusing arc quadrupoles and up to 6000 A for the insertion quadrupoles Q1 through Q9 – and higher temperatures – up to 5.1 K – than routine. None of the magnets quenched. This is an encouraging finding as the superconducting magnet coils could reach up to 4.9 K during operation with the 275 GeV EIC hadron beams.

43 PARTICLE ACCELERATORS↗

Alkali-Metal Interlocking of 2D V 4 O 10 Sheets Defines Discretized Interlayer Shear Relationships

Low-dimensional materials manifest structural anisotropy, quantum confinement, and tightly bound excitonic states, which make them attractive building blocks that can be assembled within three-dimensional laterally stitched heterostructures, stacked van der Waals solids, and complex moiré superlattices. Ion intercalation in the galleries between layered materials provides a means of modifying interlayer separation and coupling, but it is also known to drive the shearing of the layers. In this article, we explore the distinct ligand coordination environments afforded by vanadyl oxygens of singular [V 4 O 10 ] sheets and examine how the size, polarizability, and stoichiometry of Group I cations sandwiched between such layers determine the interlocking of the sheets in stacked structures. Based on the topochemical insertion of alkali-metal ions into the layered λ-V 2 O 5 , we identify seven types of guest ion coordination sites discretized into four distinct regimes of interlayer shear in units of half octahedral widths. The coordination preferences of intercalated cations govern how they interlock 2D [V 4 O 10 ] sheets and engender specific shear conformations. We present evidence that static and dynamic disorder in guest ion arrangement modulate the magnetic structure of the intercalated compounds based on electrostatic polarization, localization of charge and spin density, and lattice distortion. The results illustrate the use of topochemical ion insertion to modulate stacking relationships and magnetic transition characteristics.

36 MATERIALS SCIENCE↗

De novo design of transmembrane β barrels

Transmembrane β-barrel proteins (TMBs) are of great interest for single-molecule analytical technologies because they can spontaneously fold and insert into membranes and form stable pores, but the range of pore properties that can be achieved by repurposing natural TMBs is limited. We leverage the power of de novo computational design coupled with a “hypothesis, design, and test” approach to determine TMB design principles, notably, the importance of negative design to slow β-sheet assembly. We design new eight-stranded TMBs, with no homology to known TMBs, that insert and fold reversibly into synthetic lipid membranes and have nuclear magnetic resonance and x-ray crystal structures very similar to the computational models. These advances should enable the custom design of pores for a wide range of applications.

Vorobieva, Anastassia A.↗

An improved nuclear magnetic resonance spectrometer

Cylindrical sample container provides a high degree of nuclear stabilization to a nuclear magnetic resonance /nmr/ spectrometer. It is placed coaxially about the nmr insert and contains reference sample that gives a signal suitable for locking the field and frequency of an nmr spectrometer with a simple audio modulation system.

Elleman, D. D.↗

High-power and 2.5 kW advanced-technology ion thruster

Investigations for improving ion thruster components in the 30 cm engineering model thruster (EMT) resulted in the demonstration of useful techniques for grid short removal and discharge chamber erosion monitoring, establishment of relationships between double ion production and thruster operating parameters, verification of satisfactory specifications on porous tungsten vaporizer material and barium impregnated porous tungsten inserts, demonstration of a new hollow cathode configuration, and specification of magnetic circuit requirements for reproducing desired magnetic mappings. The capacity of a 30 cm EMT to operate at higher beam voltages and currents (higher power) was determined. Operation at 2 A beam current and higher beam voltage is shown to be essentially equivalent to operation at 1.1 kV with regard to efficiency, lifetime and operating conditions. The only additional requirement is an improvement in high voltage insulation and propellant isolator capacity. Operation at minimum voltage and higher beam currents is shown to increase thruster discharge chamber erosion in proportion to beam current. Studies to find alternatives to molybdenum for manufacturing ion optics grids are also reported.

Poeschel, R. L.↗

Test Results of the First Two Full-Length Quadrupole Magnets for the LHC Hi Lumi Upgrade

The future high luminosity (Hi-Lumi) upgrade of the Large Hadron Collider (LHC) at CERN will include eight (plus two spares) 8.4 m-long cryostatted cold masses which will be components of the triplets for two LHC insertion regions. Each cold mass will consist of two 4.2 m long Nb 3 Sn high gradient quadrupole magnets, designated MQXFA, with aperture 150 mm and operating gradient 132.6 T/m, for a total of twenty magnets. Before assembling and testing the final cold masses at Fermilab, the twenty component quadrupoles will be tested first at the ver-tical superconducting magnet test facility of the Superconducting Magnet Division at Brookhaven National Laboratory (BNL), in superfluid He at 1.9 K and to 18.0 kA, to meet LHC operational requirements. The first two full-length prototype quadrupole magnets, MQXFAP1 and MQXFAP2, have been tested at BNL. This paper reports on the quench test and training results of these magnets, and also the retest of the first prototype, rebuilt and designated as MQXFAP1b. We note the test results of these magnets will be important for validating the MQXFA design.

43 PARTICLE ACCELERATORS↗

Diamond magnetometer enhanced by ferrite flux concentrators

Magnetometers based on nitrogen-vacancy (NV) centers in diamond are promising room-temperature, solid-state sensors. However, their reported sensitivity to magnetic fields at low frequencies (≲1 kHz) is presently ≳10 pTs 1/2 , precluding potential applications in medical imaging, geoscience, and navigation. Here we show that high-permeability magnetic flux concentrators, which collect magnetic flux from a larger area and concentrate it into the diamond sensor, can be used to improve the sensitivity of diamond magnetometers. By inserting an NV-doped diamond membrane between two ferrite cones in a bowtie configuration, we realize a ~ 250-fold increase of the magnetic field amplitude within the diamond. We demonstrate a sensitivity of ~ 0.9pTs 1/2 to magnetic fields in the frequency range between 10 and 1000 Hz. This is accomplished using a dual-resonance modulation technique to suppress the effect of thermal shifts of the NV spin levels. The magnetometer uses 200 mW of laser power and 20 mW of microwave power. This work introduces a new degree of freedom for the design of diamond sensors by using structured magnetic materials to manipulate magnetic fields.

47 OTHER INSTRUMENTATION↗

New proposed ITER divertor design using carbon insert on tungsten to mitigate ELMs and secondary radiation effects on nearby components

Abstract Building a successful device for the magnetic fusion energy production is a great challenge. ITER is an international project of the tokamak based magnetic fusion design being developed for the demonstration of the feasibility of thermonuclear technologies for future realization of successful commercial fusion energy. A key obstacle to a successful magnetic fusion energy production is however, the performance during abnormal events including plasma disruptions and edge-localized modes (ELMs). A credible reactor design must tolerate at least a few of these transient events without serious consequences such as melting of the structure. This paper investigates and compares the performance of the current ITER tokamak design during two types of transient events, i.e., ELMs occurring at normal operation and disruptions during abnormal operation. We simulated the divertor components response using our integrated 3D HEIGHTS package. The simulations include self-consistent modeling of the interaction of the released core plasma particles with the initial solid divertor material, energy deposition processes, vaporization of divertor material, secondary plasma formation and MHD evolution, incident core particles collisions and scattering from this dense secondary plasma, photon radiation of secondary plasma, and the resulting heat loads on nearby components. Our simulations showed that using a small carbon insert around the strike point can significantly reduce the overall expected damage on the tungsten dome structure, reflector plates, and prevent tungsten vaporization and its potential core plasma contamination.

47 OTHER INSTRUMENTATION↗

Mass drivers. 3: Engineering

This paper is the last of a series of three by the Mass-Driver Group of the 1977 Ames Summer Study. It develops the engineering principles required to implement the basic mass-driver design defined in paper I and as presented previously in the literature. Optimum component mass trade-offs are derived from a set of four input parameters, and the program used to design a lunar launcher. The mass optimization procedure is then incorporated into a more comprehensive mission optimization program called OPT-4, which evaluates an optimized mass-driver reaction engine and its performance in a range of specified missions. Finally, this paper discusses, to the extent that time permitted, certain peripheral problems: heating effects in buckets due to magnetic field ripple; an approximate derivation of guide force profiles; the mechanics of inserting and releasing payloads; the reaction mass orbits; and a proposed research and development plan for implementing mass drivers. This paper also considers further optimization that depends on advances in component technology beyond the present state. It is concluded that significant advantage can be gained in the case of small reaction engines with high emission velocity by developing lightweight packaging technology for silicon-controlled rectifiers (SCR's).

William H. Arnold↗

Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system's eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware. Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in a beat frequency. However, for PDV, discerning the signal from the noise is difficult without a moving source to induce the modulation. A rotating wheel is currently being used as the moving source but its configuration is impractical and has cumbersome placement inside the current frangible joint test cell. As a way to combat this problem and verify a satisfactory signal-to-noise ratio, a reflective moving crystal piezo will be used to modulate a beat frequency, and an absorptive target will be used to block the signal in order to determine any back reflection coming from the probe and discern the true signal-to-noise ratio. The piezo will be mounted and inserted onto the test table on an extendable telescopic antenna grounded by a magnetic base in the test zone. This piezo configuration will be more compatible within the test zone and allow for easy removal of the disk following acceptable signal verification and prior to frangible joint tests.

Ellis, Tayera↗

Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system’s eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware.Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in a beat frequency. However, for PDV, discerning the signal from the noise is difficult without a moving source to induce the modulation. A rotating wheel is currently being used as the moving source but its configuration is impractical and has cumbersome placement inside the current frangible joint test cell. As a way to combat this problem and verify a satisfactory signal-to-noise ratio, a reflective moving crystal piezo will be used to modulate a beat frequency, and an absorptive target will be used to block the signal in order to determine any back reflection coming from the probe and discern the true signal-to noise ratio. The piezo will be mounted and inserted onto the test table on an extendable telescopic antenna grounded by a magnetic base in the test zone. This piezo configuration will be more compatible within the test zone and allow for easy removal of the disk following acceptable signal verification and prior to frangible joint tests.Additionally, topics of what was learned and smaller tasks given at White Sands Test Facility (WSTF) will be discussed. All statements in this paper are newly gained knowledge of what I have learned, observed, and have done while at WSTF.

Ellis, Tayera↗

Mars Global Surveyor Mission

The Mars Global Surveyor (MGS) spacecraft will be launched in November 1996 to the planet Mars for an extended study of the planet's surface, atmosphere, gravitational field, and magnetic field. In order to achieve the scientific objectives of the mission, the spacecraft will be inserted into a low-altitude, near-polar, sun-synchronous orbit. Data will be collected for over one Martian year (687 Earth days) and will provide for a better understanding of the geology, geophysics, and climatology of Mars.

Mars↗