Search NASA⌕ Search

SEARCH · Search NASA

Results for “installation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Successful cleanroom installation of PIP-II SSR2 coupler using robotic arm

To minimize the contamination of SRF cavities, remote installation techniques are needed during the installation of components. Recent work at Fermilab has been performed to begin the process of developing techniques for assembling cavities using robotics. Multiple alignment methods were prototyped including alignment and computer vision methods. Using a remotely controlled robotic arm, the alignment and installation of couplers have been successfully performed on prototype PIP-II SSR2 cavities in a cleanroom. The installation process will be shown to show to demonstrate the potential of future installations on other cavities and cavity ancillaries.

43 PARTICLE ACCELERATORS↗

Renewable Energy Assessment Methodology for Japanese OCONUS Army Installations

Since 2005, Pacific Northwest National Laboratory (PNNL) has been asked by Installation Management Command (IMCOM) to conduct strategic assessments at selected US Army installations of the potential use of renewable energy resources, including solar, wind, geothermal, biomass, waste, and ground source heat pumps (GSHPs). IMCOM has the same economic, security, and legal drivers to develop alternative, renewable energy resources overseas as it has for installations located in the US. The approach for continental US (CONUS) studies has been to use known, US-based renewable resource characterizations and information sources coupled with local, site-specific sources and interviews. However, the extent to which this sort of data might be available for outside the continental US (OCONUS) sites was unknown. An assessment at Camp Zama, Japan was completed as a trial to test the applicability of the CONUS methodology at OCONUS installations. It was found that, with some help from Camp Zama personnel in translating and locating a few Japanese sources, there was relatively little difficulty in finding sources that should provide a solid basis for conducting an assessment of comparable depth to those conducted for US installations. Project implementation will likely be more of a challenge, but the feasibility analysis will be able to use the same basic steps, with some adjusted inputs, as PNNL’s established renewable resource assessment methodology.

09 BIOMASS FUELS↗

Tracking the Sun VIII. The Installed Price of Residential and Non-Residential Photovoltaic Systems in the United States

Now in its eighth edition, Lawrence Berkeley National Laboratory (LBNL)’s Tracking the Sun report series is dedicated to summarizing trends in the installed price of grid-connected solar photovoltaic (PV) systems in the United States. The present report focuses on residential and nonresidential systems installed through year-end 2014, with preliminary trends for the first half of 2015. As noted in the text box below, this year’s report incorporates a number of important changes and enhancements. Among those changes, this year's report focuses solely on residential and nonresidential PV systems; data on utility-scale PV are reported in LBNL’s companion Utility-Scale Solar report series. Installed pricing trends presented within this report derive primarily from project-level data reported to state agencies and utilities that administer PV incentive programs, solar renewable energy credit (SREC) registration systems, or interconnection processes. In total, data were collected for roughly 400,000 individual PV systems, representing 81% of all U.S. residential and non-residential PV capacity installed through 2014 and 62% of capacity installed in 2014, though a smaller subset of this data were used in analysis.

14 SOLAR ENERGY↗

B341 MoMs Hydraulic System Design & Installation

This Statement of Work Document outlines the program equipment siting requirements for Building 341 to be installed at Lawrence Livermore National Laboratory (LLNL). The Subcontractor, who will be designing and installing B341 programmatic equipment hydraulic system, will be expected to provide engineering and construction support from procurement through installation. This scope of work includes the following: a) Walkdown and survey existing condition of Mechanics of Material (MoMs) programmatic equipment at B231. b) Engineering design, procurement, and installation of hydraulic system for MOMs programmatic equipment. c) Engineering design, procurement, and installation of indoor and outdoor hydraulic pumps. d) Engineering design of program equipment pits. e) Engineering design of new trenches to match existing B341 trenches.

42 ENGINEERING↗

Floating Photovoltaic System Cost Benchmark: Q1 2021 Installations on Artificial Water Bodies

In this report, we conduct a bottom-up analysis of the installed costs for FPV systems deployed on artificial water bodies under average site conditions (wind load of about 40 m/s, snow load of 20 psf, water depth of 50 m, water level variation of 10 m, and swell height of 1 m). We estimate an installed system cost premium of $\$0.26$/WDC (25%) for 10-MWDC fixed-tilt FPV systems, compared with ground-mounted, fixed-tilt PV installed over bare ground. Higher structural costs related to the floats and anchoring system are the largest contributors to this premium. Currently, site investigation costs are also higher for FPV because of the additional effort needed to plan and design these more complex installations. Our preliminary sensitivity analysis shows that the installed cost of FPV systems is most sensitive to float costs, wind and snow loading, and module efficiency. FPV deployment is in an early stage, and additional experience, best practice development, and new configurations and technologies could help reduce the costs of FPV systems over time.

14 SOLAR ENERGY↗

Transducer Installation Effects on Pressure Measurements in PGC Devices

Pressure gain devices such as rotating detonation engines present an extremely harsh environment, generally precluding the use of any intrusive probe measurement. The most widely used diagnostic is the measurement of high frequency pressure which can be used to determine the pressure amplitude, number of waves and their direction and the wave structure. The preferred approach for making pressure measurements is to install the sensing element flush with the combustion chamber wall, but is almost always inhibited by the extremely high heat fluxes that can damage the sensor. Alternately, recessed cavity or infinite probe installation is seldom used for high frequency pressure measurements. While amplitude attenuation and phase distortion of the pressure signal can be introduced by these installation types, its characterization in the presence of high amplitude steep fronted pressure waves encountered in PGC devices has not been previously performed. In the current work a highly modular calibration test-bed is designed to enable characterization of pressure transducers based on their installation in the presence of steep fronted high amplitude pressure waves. Two transducer types, piezoelectric PCB® 113B26 and water-cooled piezoresistive Kulite®WCT-312M were used and installed in the flush, recessed cavity and infinite tube probe configuration. The recessed cavity probe showed 5-26% amplitude attenuation and almost negligible time lag compared to the flush transducer, the infinite tube pressure (ITP) transducer showed a significantly higher delay and as much as 50% reduction in measured pressure amplitude. Secondary wave features from reflections within the test article, that were captured by the flush and recessed cavity transducer were damped by the infinite probe measurement.

20 FOSSIL-FUELED POWER PLANTS↗

Empirical Estimation of the Energy Impacts of Projects Installed through Residential Property Assessed Clean Energy Financing Programs in California

We examine the energy use impacts of energy efficiency and solar PV projects financed by residential property assessed clean energy (R-PACE) programs in California. We leverage household-level interval meter data to apply normalized metered energy consumption (NMEC) methods at significant scale—more than 25,000 electric meters and more than 15,000 gas meters. We develop a comparison group to account for non-project-related changes in usage. The projects include homes that replaced existing HVAC equipment with higher-efficiency units and homes that installed central heating or air conditioning equipment for the first time. We have limited information on pre-project household equipment stock so we develop a method to infer new installations. We find that projects that installed energy efficiency technologies reduce electricity consumption by approximately 3% and gas consumption by approximately 3.5% on average. When we remove homes that installed new cooling and heating equipment for the first time, savings rise to approximately 5% for electricity and approximately 6% for gas. Given the California climate and the results of an existing study of similar California projects, these results are in line with expectations. Solar PV projects produce electricity that offsets approximately 69% of household electricity consumption on average. We estimate that California R-PACE projects installed through the end of 2019 produce annual reductions in grid-tied electricity consumption of 506 GWh (equivalent to the electricity consumption of approximately 74,000 California households) and gas consumption reductions of 2 million therms (equivalent to the gas consumption of approximately 4700 California households) in a typical weather year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NASTRAN Installation: Implementation Steps and Possible Problems Encountered

NASTRAN, from its inception, was designed to operate on several diverse computer system. It is currently installed and operating on the CDC 6600, the IBM 360, and the UNIVAC 1108. This paper discusses the steps found by CSC to be necessary in installing NASTRAN on a computer system and the possible obstacles that might be encountered in undertaking NASTRAN installation. Reference is made to actual problems that arose during installation on the above machines. With a knowledge of what has happened to date in setting up NASTRAN, the future user will be better able to cope with and understand the implications of installing NASTRAN on his computer.

Dielmann, H. E.↗

Automated installation of large platform utilities

The capabilities of the assembler in installing nonstructural platform systems were assessed. These systems include electrical power distribution, heat transport, command and data signal transmission, and payload data transmission. The effects of including installation of utilities on the assembly process and on the design, operation, and performance of the assembler were evaluated. In addition, any special requirements on the assembler and/or the platform due to the installation of utilities were identified. The procedure followed was to define a set of candidate utility characteristics and installation requirements, define and design installation concepts, and perform an assessment of impacts on the assembler and its operation.

Vernon, R. M.↗

An experimental investigation of an advanced turboprop installation on a swept wing at subsonic and transonic speeds

An investigation was conducted in the Langley 16-Foot Transonic Tunnel to determine the effects of a turboprop-nacelle installation on the pressure distributions over a swept, supercritical wing. The tests were conducted at Mach numbers from 0.20 to 0.80, at angles of attack from 0 to 5 degrees, nacelle nozzle pressure ratios from 1.0 to 1.6, and at propeller tip speeds from 700 to 800 ft/sec. The results of this study indicate that the turboprop nacelle interference, with and without power, on a swept wing is greater on the inboard wing panel than on the outboard wing panel. The over-the-wing nacelle installation with the propeller upwash on the inboard panel had flow separation problems at a Mach number of 0.80. No severe flow separation problems appear to exist for either propeller rotation direction for the under-the-wing nacelle installation. The local flow disturbances caused by the under-the-wing nacelle installation were in general less severe than for the over-the-wing nacelle installation.

Carlson, John R.↗

Vortex generator installation studies on steady state and dynamic inlet distortion

The theoretical and experimental work carried out under the NASA/MOD Joint Aeronautical Program has shown that CFD vortex generator installations designs successfully managed inlet duct flow distortion and that significant benefits in flow unsteadiness at the engine face were also present. The main conclusions to date from the collaborative effort between NASA/Lewis and DRA/Bedford are as follows: (1) vortex generator installations can be designed to be effective over a wide range of inlet operating conditions using Computational Fluid Dynamics and formal optimization procedures, (2) reductions in steady state engine face distortion of up to 80% have been measured in the M2129 inlet S-duct using CFD designed vortex generator installations, (3) reductions in flow unsteadiness of up to 80% have been measured in the W129 inlet S-duct using CFD designed vortex generator installations, and (4) the Reduced Navier-Stokes code RNS3D is a useful tool to design vortex generator installations to manage engine face distortions over a wide range of inlet operating conditions.

Anderson, Bernhard H.↗

Purchase and Installation of NanoSIMS 50

Although this is a final report on NASA grant number NAG5-8729 we wish to state at the outset that it was mistakenly written as a two-year grant instead of a three-year grant as should have been done. The grant was made for the purpose of purchasing and installing a novel ion microprobe initially called the NanoSIMS 50 and now called the NanoSIMS. The total cost to NASA for purchasing the instrument and refurbishing a laboratory to house it was $1.1 M, split into three installments of $400 (FY 1999), $350K (FY2000), and $350K (FY-2001). We received the first installment in full and $335K in FY2000 for the second installment. The final $350K necessary to complete the purchase and installation was expected by us in the spring of 2001. However, we were recently informed that no more money can be transferred on this grant since it was originally written as a two-year grant. Therefore, we are closing out the current grant and simultaneously writing a new proposal to obtain the final $350K needed to complete the purchase.

Walker, Robert M.↗

Spin Investigation of a 1/29-Scale Model of the Republic XF-91 Airplane with a Conventional Tail Installed

An investigation has been conducted in the Langley 20-foot free-spinning tunnel of a 1/29-scale model of the Republic XF-91 airplane with a.conventional-tail arrangement installed. Previously, tests were made on the model with a vee tail installed. The erect spin and recovery characteristics of the model were determined for the normal loading with the wing installed at various amounts of incidence. The spin investigation also included inverted-spin tests, spin-recovery-parachute tests, tests with the center of gravity moved rearward, and tests with external fuel tanks added to the model. In addition, several tail.modifications were tested,on the model in an attempt, to improve the model's spin-recovery characteristics. The results indicate that any fully developed spin obtained on the airplane with the conventional tail installed will be satisfactorily terminated if rudder reversal is accompanied by moving the ailerons with the spin (stick right in a right spin).Decreasing the wing incidence from 6deg to -2deg should have a beneficial effect on the recovery characteristics of the airplane. Recovery characteristics by normal use of controls (full rudder reversal followed by moving the elevators down) will be satisfactory if the wing incidence,of the airplane is -2deg. Installation of external fuel tanks (with or without fuel) will have a somewhat adverse effect on the recovery characteristics of the airplane, but if the recovery technique includes movement of the ailerons to full with the spin, the spin rotation will be terminated rapidly. Varying the position of the center of gravity within the limits indicated to be possible on the airplane should not affect the recovery characteristics.

Klinar, Walter J.↗

CFD-CAA Coupled Calculations of a Tandem Cylinder Configuration to Assess Facility Installation Effects

This paper presents a numerical assessment of acoustic installation effects in the tandem cylinder (TC) experiments conducted in the NASA Langley Quiet Flow Facility (QFF), an open-jet, anechoic wind tunnel. Calculations that couple the Computational Fluid Dynamics (CFD) and Computational Aeroacoustics (CAA) of the TC configuration within the QFF are conducted using the CFD simulation results previously obtained at NASA LaRC. The coupled simulations enable the assessment of installation effects associated with several specific features in the QFF facility that may have impacted the measured acoustic signature during the experiment. The CFD-CAA coupling is based on CFD data along a suitably chosen surface, and employs a technique that was recently improved to account for installed configurations involving acoustic backscatter into the CFD domain. First, a CFD-CAA calculation is conducted for an isolated TC configuration to assess the coupling approach, as well as to generate a reference solution for subsequent assessments of QFF installation effects. Direct comparisons between the CFD-CAA calculations associated with the various installed configurations allow the assessment of the effects of each component (nozzle, collector, etc.) or feature (confined vs. free jet flow, etc.) characterizing the NASA LaRC QFF facility.

Redonnet, Stephane↗

Vehicle for installing anchors in an underwater substrate

A method of installing one or more anchors in an underwater substrate in a body of water including installing an anchor into the underwater substrate by rotating an anchor installation vehicle about a central axis Y to drive the anchor coupled to the anchor installation vehicle into the underwater substrate. The anchor installation vehicle includes a vehicle frame having a top end and bottom end, a plurality of arms extending outward from the vehicle frame, one or more rotational thrusters disposed at distal ends of the respective arms, and an anchor system that holds the anchor extending from the bottom end of the vehicle frame with the anchor aligned with a central axis Y.

42 ENGINEERING↗

Installing Deep Groundwater Monitoring Wells in a Volcanic Dominated Rift Basin: Los Alamos National Laboratory, New Mexico - 17594

Los Alamos National Laboratory (LANL, or the Laboratory) is located in northern New Mexico near the west margin of the Espanola Basin. LANL is underlain by a complex basin-fill sequence of alluvial fan deposits, volcanic tuff, basaltic and dacitic lavas, and riverine deposits. On-going environmental remediation and characterization activities have evolved to improve the performance of groundwater monitoring wells, ensuring they yield representative groundwater and core samples. Groundwater occurs as canyon-fill alluvial water, perched intermediate-depth water associated with the basalts and other local-scale perching horizons, and as a regional-scale aquifer that is the main water supply for the area. Anthropogenic contaminants are found in all three groundwater zones. The regional aquifer below LANL is nominally 1000-1400 feet below ground surface (bgs). Monitoring wells at the Laboratory, are therefore, among the deepest routinely installed in the US. Logistical challenges at LANL include steep terrain, widespread cultural sites, and threatened and endangered species habitat restrictions. Additionally, the cost of installing monitoring wells is high because of groundwater depths and the variable drilling techniques that are required to characterize and install wells in a complex geologic environment. A major challenge to the characterization approach at LANL has been to meet sample quality requirements while minimizing drilling costs. In the late 1990's threaded drill-casing was advanced by rotary drilling methods using compressed air as the only circulation fluid. This resulted in relatively low impacts to the geochemical integrity of rock and groundwater samples, but led to frequent episodes of stuck casing. Additional fluids were introduced to the air-rotary program, improving penetration rates, but also resulting in non-representative groundwater samples due to long-term impacts to the aquifer in the vicinity of the well screen. Mud-rotary drilling was incorporated into the program, but it also had significant long-term impacts on groundwater quality, and often inhibited identification of perched groundwater zones and accurate identification of the water table in the regional aquifer. Current drilling practice makes limited use of fluid additives (e.g. foam) to supplement air circulation methods in order to advance drill casing through the vadose zone. Starting about 100 feet above the water table, drill casing is advanced to the target horizon in the regional aquifer using only air and municipal water (when needed) for circulation. Additionally, the threaded drill casing couplings have been replaced with welded connections, significantly reducing the occurrence of stuck casing. Careful observations of water production and water levels during drilling, coupled with the ability to retract casing for video and geophysical logs, now allows for robust characterization of perched groundwater systems and accurate definition of the top of regional saturation. Recent advances in the drilling program include combined dual-rotary/sonic drilling to depths up to 1150 feet and dual-rotary casing advance at angles up to 25 deg. from vertical. The former allows for core collection with minimal fluid addition, thereby preserving pore water chemistry. The latter method allows for well installation into portions of the aquifer otherwise inaccessible due to constraints at the surface (e.g., cultural sites or topography). Similar to the development of drilling techniques, both well design and groundwater sampling system design have evolved throughout the program. Current well design emphasizes a minimal annulus of filter pack, maximum screen slot size based on formation sieve analyses, and thorough well development to mitigate formation damage due to drilling. To sample groundwater at multiple levels in the same well, earlier sampling systems included Westbay{sup R} multi-zone systems and dual-screen single-pump and dual-screen dual-pump systems designed in collaboration with Baski, Inc. These multi-zone sampling systems proved difficult to develop and maintain given the depth to groundwater, and most current well installations are configured with a single screen and a submersible pump. The ability to purge from a well-developed single-screen well has substantially improved the collection of representative groundwater samples. A carefully crafted groundwater characterization program in target aquifers at depths ranging from 1,000 to 1,400 feet bgs within a complex geologic setting, while also retaining the ability to collect representative core and groundwater samples, may have application at a number of sites throughout the environmental industry. Optimizing each well to meet program objectives while reducing total project costs benefits all environmental investigations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Net Zero Energy Military Installations: A Guide to Assessment and Planning

The U.S. Department of Defense (DoD) recognizes the strategic importance of energy to its mission, and is working to reduce energy consumption and enhance energy self-sufficiency by drawing on local clean energy sources. A joint initiative formed between DoD and the U.S. Department of Energy (DOE) in 2008 to address military energy use led to a task force to examine the potential for net zeroenergy military installations, which would produce as much energy on site as they consume in buildings, facilities, and fleet vehicles. This report presents an assessment and planning process to examine military installations for net zero energy potential. Net Zero Energy Installation Assessment (NZEIA) presents a systematic framework to analyze energy projects at installations while balancingother site priorities such as mission, cost, and security.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of installation faults in air conditioners and heat pumps in single-family homes on U.S. energy usage

To ensure that new residential air conditioners and heat pumps operate optimally, care must be taken during the initial system design and installation to avoid missteps that immediately degrade a system’s performance. Laboratory and simulation studies have quantified the impact that faults can have on capacity and efficiency. Field studies have demonstrated that installation-related faults are commonplace. However, the national impact of installation-related faults cannot be accurately estimated by only simulating a limited number of homes at several fault levels because of the variety of home characteristics and climates involved. In our analysis, we use an improved residential building stock simulation tool to predict the annual energy increase and additional utility costs resulting from two common installation faults: indoor airflow rate and refrigerant charge level. Our method considers the wide range of building characteristics and climate zones of the U.S. housing stock. We use existing field data to develop fault intensity probability distributions to inform our analysis. The study shows that these two faults result in approximately 20.7 TWh/y of additional energy use for central air conditioners and air-source heat pumps in U.S. single-family detached homes, which is a 9% increase over baseline (no-fault) usage, costing homeowners approximately $2.5 billion annually on utility bills. Air-source heat pumps are responsible for a disproportionate fraction of this energy use increase because of the larger number of operating hours compared to central air conditioners and the sensitivity of heating mode performance to the faults analyzed compared to cooling mode.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗