Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrument designs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The Cabauw Intercomparison Campaign for Nitrogen Dioxide Measuring Instruments (CINDI): Design, Execution, and Early Results

From June to July 2009 more than thirty different in-situ and remote sensing instruments from all over the world participated in the Cabauw Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI). The campaign took place at KNMI's Cabauw Experimental Site for Atmospheric Research (CESAR) in the Netherlands. Its main objectives were to determine the accuracy of state-ofthe- art ground-based measurement techniques for the detection of atmospheric nitrogen dioxide (both in-situ and remote sensing), and to investigate their usability in satellite data validation. The expected outcomes are recommendations regarding the operation and calibration of such instruments, retrieval settings, and observation strategies for the use in ground-based networks for air quality monitoring and satellite data validation. Twenty-four optical spectrometers participated in the campaign, of which twenty-one had the capability to scan different elevation angles consecutively, the so-called Multi-axis DOAS systems, thereby collecting vertical profile information, in particular for nitrogen dioxide and aerosol. Various in-situ samplers and lidar instruments simultaneously characterized the variability of atmospheric trace gases and the physical properties of aerosol particles. A large data set of continuous measurements of these atmospheric constituents has been collected under various meteorological conditions and air pollution levels. Together with the permanent measurement capability at the CESAR site characterizing the meteorological state of the atmosphere, the CINDI campaign provided a comprehensive observational data set of atmospheric constituents in a highly polluted region of the world during summertime. First detailed comparisons performed with the CINDI data show that slant column measurements of NO2, O4 and HCHO with MAX-DOAS agree within 5 to 15%, vertical profiles of NO2 derived from several independent instruments agree within 25% of one another, and MAX-DOAS aerosol optical thickness agrees within 20-30% with AERONET data. For the in-situ NO2 instrument using a molybdenum converter, a bias was found as large as 5 ppbv during day time, when compared to the other in-situ instruments using photolytic converters.

Atmospheric composition↗

The Landsat Data Continuity Mission Operational Land Imager (OLI) Radiometric Calibration

The Operational Land Imager (OLI) on the Landsat Data Continuity Mission (LDCM) has a comprehensive radiometric characterization and calibration program beginning with the instrument design, and extending through integration and test, on-orbit operations and science data processing. Key instrument design features for radiometric calibration include dual solar diffusers and multi-lamped on-board calibrators. The radiometric calibration transfer procedure from NIST standards has multiple checks on the radiometric scale throughout the process and uses a heliostat as part of the transfer to orbit of the radiometric calibration. On-orbit lunar imaging will be used to track the instruments stability and side slither maneuvers will be used in addition to the solar diffuser to flat field across the thousands of detectors per band. A Calibration Validation Team is continuously involved in the process from design to operations. This team uses an Image Assessment System (IAS), part of the ground system to characterize and calibrate the on-orbit data.

Markham, Brian L.↗

Hawkeye Ocean Color Instrument – Performance Summary

Hawkeye is an ocean color instrument that is part of the SeaHawk satellite developed for SOCON, the Sustained Ocean Color Observations using Nanosatellites program funded by the Gordon and Betty Moore Foundation and managed by the University of North Carolina – Wilmington (UNC-W). HawkEye has spectral characteristics similar to SeaWiFS, but with 8 times finer resolution and a smaller field of view more appropriate for lakes, rivers, and near-shore terrestrial environments. With a volume of only 10 X 10 X 10 cm (a CubeSat 1U), it can produce 8 bands of image data in a single pass, each with 1800 x 6000 pixels, with a resolution of 120 meters per pixel. This paper will present a short summary of instrument design, the spacecraft interface, and “lessons learned” during this effort. Scientists considering using linear arrays in a pushbroom mode for remote sensing will find this useful. Much of the discussion will center on optical performance, such as flat field calibration, polarization effects, stray light, out-of-band response, and exposure linearity. Images from field tests will be shown.The Hawkeye instrument is an ocean color measuring instrument designed to fly on the SeaHawk satellite developed for SOCON, the Sustained Ocean Color Observations using Nanosatellites program funded by the Gordon and Betty Moore Foundation and managed by the University of North Carolina – Wilmington (UNC-W). The Hawkeye instrument measures ocean color in 8 spectral bands, similar to SeaWiFS, except Band 7, which is shifted to a slightly lower wavelength to avoid the oxygen absorption feature that a wider band overlapped on SeaWiFS. The instrument is approximately 1/3rd the volume of the entire satellite, which is a 3U Cubesat manufactured by Clydespace in Glasgow, Scotland. The purpose of this instrument is to ascertain the quality of ocean color data possible with such a small, inexpensive instrument and bus. The nominal orbit is 540 km, and the nominal pixel geometric instantaneous field of view (GIFOV) 120 meters on a side. Each band will produce an image 1800 x 6000 pixels in size, for a total field of view of 216 X 720 km.2) DESIGN CONCEPTThe Hawkeye instrument uses linear arrays in pushbroom mode to collect data over a two dimensional area. The instrument has 4 linear CCD arrays, the Onsemi KLI-4104, to collect the 8 bands of data. Figure 1 illustrates the optical design for two bands, sharing a single array.

Hawkeye↗

Glucose determination in human aqueous humor with Raman spectroscopy

It has been suggested that spectroscopic analysis of the aqueous humor of the eye could be used to indirectly predict blood glucose levels in diabetics noninvasively. We have been investigating this potential using Raman spectroscopy in combination with partial least squares (PLS) analysis. We have determined that glucose at clinically relevant concentrations can be accurately predicted in human aqueous humor in vitro using a PLS model based on artificial aqueous humor. We have further determined that with proper instrument design, the light energy necessary to achieve clinically acceptable prediction of glucose does not damage the retinas of rabbits and can be delivered at powers below internationally acceptable safety limits. Herein we summarize our current results and address our strategies to improve instrument design. 2005 Society of Photo-Optical Instrumentation Engineers.

Spectrum Analysis, Raman/methods↗

Submillimeter and Far Infrared Experiment for SOFIA (SAFIRE): Progress and Prospects

SAFIRE/SOFIA is a versatile imaging Fabry-Perot spectrograph covering 100 less than lambda less than 655 microns, with spectral resolving power of approx. l0(exp 3). Selected as a "PI" instrument for the airborne Stratospheric Observatory for Infrared Astronomy (SOFIA), SAFIRE will apply two dimensional pop-up bolometer arrays to provide background limited imaging spectrometry. We describe the instrument design, its application to a range of astro- physical investigations, and current progress and results in the innovative detector and instrument design. SAFIRE/SOFIA is on track for availability in 2006.

Shafer, R. A.↗

[Methods Used for Monitoring Cure Reactions in Real-time in an Autoclave]

The goal of the research was to investigate methods for monitoring cure reactions in real-time in an autoclave. This is of particular importance to NASA Langley Research Center because polyimides were proposed for use in the High Speed Civil Transport (HSCT) program. Understanding the cure chemistry behind the polyimides would allow for intelligent processing of the composites made from their use. This work has led to two publications in peer-reviewed journals and a patent. The journal articles are listed as Appendix A which is on the instrument design of the research and Appendix B which is on the cure chemistry. Also, a patent has been awarded for the instrumental design developed under this grant which is given as Appendix C. There has been a significant amount of research directed at developing methods for monitoring cure reactions in real-time within the autoclave. The various research efforts can be categorized as methods providing either direct chemical bonding information or methods that provide indirect chemical bonding information. Methods falling into the latter category are fluorescence, dielectric loss, ultrasonic and similar type methods. Correlation of such measurements with the underlying chemistry is often quite difficult since these techniques do not allow monitoring of the curing chemistry which is ultimately responsible for material properties. Direct methods such as vibrational spectroscopy, however, can often be easily correlated with the underlying chemistry of a reaction. Such methods include Raman spectroscopy, mid-IR absorbance, and near-IR absorbance. With the recent advances in fiber-optics, these spectroscopic techniques can be applied to remote on-line monitoring.

Cooper, John B.↗

Optical-system design for next-generation pushbroom sensors

Next-generation pushbroom sensors for earth observation require high-performance optics that provide high spatial resolution over wide fields of view. Specifically, blur diameters on the order of 10 to 15 microns are needed over 5 to 15 deg fields. In addition to this fundamental level of optical performance, other characteristics, such as spatial coregistration of spectral bands, flat focal plane, telecentricity, and workable pupil location are significant instrument design considerations. The detector-assembly design, optical line-of-sight pointing method and sensor packaging all hinge on these secondary attributes. Moreover, the need for broad spectral coverage, ranging from 0.4 to 12.5 microns, places an additional constraint on optical design. This paper presents alternative design forms that are candidates for wide-field pushbroom sensors, and discusses the instrument-design tradeoffs that are linked to the selection of these alternate optical approaches.

Mika, A. M.↗

Development Status of Cassini Radar For Remote Sensing of Titan

Cassini Radar is a multimode rada instrument designed to probe the optically inaccessible surface of Titan, Saturn's largest moon. The individual modes will allow surface imaging, surface emissivity measurements. Recently, the breadboard model of this instrument was built and has undergone a series of functional and perfomance tests. The results obtained from these tests indicate that the instrument design is satisfactory and that the various required performance parameters are suffieciently met.

Cassini Radar Titan↗

The Infrared Spectrograph on the Spitzer Space Telescope

The Infrared Spectrograph (IRS) instrument on the Spitzer Space Telescope covered the 5 to 38 micron wavelength range at low and medium spectral resolutions. The instrument was very popular during Spitzer’s 5.7 year-long cold mission. Every year it attracted the most proposals, and garnered more observing hours, of any of the science instruments. This success was the culmination of a very long development period, where the instrument design changed radically. When the instrument was first selected by NASA in 1984 it was very complicated. As part of the overall reduction of the size of the SIRTF Observatory following its recovery from the mission’s cancellation in 1991 the IRS became smaller and much, much simpler. The only aspect of the instrument that increased from the original design was the pixel count of the detectors. The new, lean, IRS based on eight axioms: (1) SIRTF is a cost-driven mission; (2) Only Boeing Si:As and Si:Sb 128x128 BIB arrays shall be used; (3) The IRS has all Aluminum housing and optics; (4) Simple optics consisting of surfaces of revolution, flat gratings, and “bolt-and-go” tolerances; (5) No moving parts; (6) Redundancy only for credible single-point failures; (7) Strive for an observing efficiency of 80%; (8) The IRS shall be capable of internal health assessment. This led to a simple, robust, but still extremely powerful final instrument composed of four distinct modules. Many of the features developed for the IRS were subsequently employed in other spacecraft and SOFIA science instrumentation. This presentation will cover the developmental history of the IRS instrument, its final design and performance, and will especially highlight the sage decisions that Jim Houck made along the way that led to its highly successful career on the Spitzer Space Telescope.

Roellig, Thomas L.↗

Identifying Galactic Cosmic Ray Origins With Super-TIGER

Super-TIGER (Super Trans-Iron Galactic Element Recorder) is a new long-duration balloon-borne instrument designed to test and clarify an emerging model of cosmic-ray origins and models for atomic processes by which nuclei are selected for acceleration. A sensitive test of the origin of cosmic rays is the measurement of ultra heavy elemental abundances (Z > or equal 30). Super-TIGER is a large-area (5 sq m) instrument designed to measure the elements in the interval 30 < or equal Z < or equal 42 with individual-element resolution and high statistical precision, and make exploratory measurements through Z = 60. It will also measure with high statistical accuracy the energy spectra of the more abundant elements in the interval 14 < or equal Z < or equal 30 at energies 0.8 < or equal E < or equal 10 GeV/nucleon. These spectra will give a sensitive test of the hypothesis that microquasars or other sources could superpose spectral features on the otherwise smooth energy spectra previously measured with less statistical accuracy. Super-TIGER builds on the heritage of the smaller TIGER, which produced the first well-resolved measurements of elemental abundances of the elements Ga-31, Ge-32, and Se-34. We present the Super-TIGER design, schedule, and progress to date, and discuss the relevance of UH measurements to cosmic-ray origins.

deNolfo, Georgia↗

Design of an 8-40 GHz Antenna for the Wideband Instrument for Snow Measurements (WISM)

This poster describes the implementation of a 6x6 element, dual linear polarized array with beamformer that operates from about 8-40 GHz. It is implemented using a relatively new multi-layer microfabrication process. The beamformer includes baluns that feed dual-polarized differential antenna elements and reactive splitters that cover the full frequency range of operation. This fixed beam array (FBA) serves as the feed for a multi-band instrument designed to measure snow water equivalent (SWE) from an airborne platform known as the Wideband Instrument for Snow Measurements (WISM).

8-40 GHz Antenna↗

The Revised Space Environment Models in CREME-MC: A Replacement for CREME96

The CREME96 model has been available on the WWW for more than 10 years now. While principally for the estimation of radiation effects on spacecraft electronics, it contains space radiation environment models that have been used for instrument design calculations, estimation of instrumental background, estimation of radiation hazards and many other purposes. Because of the evolution of electronic part design we have found it necessary to revise CREME96, creating CREME-MC. As part of this revision, we are revising and extending the environmental models in CREME96. This talk will describe the revised radiation environment models that are being made available in CREME-MC

Adams, James H., Jr.↗

Concurrent Design used in the Design of Space Instruments

At the Project Design Center at the Jet Propulsion Laboratory, a concurrent design environment is under development for supporting development and analyses of space instruments in the early, conceptual design phases. This environment is being utilized by a Team I, a multidisciplinary group of experts. Team I is providing study and proposal support. To provide the required support, the Team I concurrent design environment features effectively interconnected high-end optics, CAD, and thermal design and analysis tools. Innovative approaches for linking tools, and for transferring files between applications have been implemented. These approaches together with effective sharing of geometry between the optics, CAD, and thermal tools are already showing significant timesavings.

Oxnevad, Knut I.↗

SeaWinds Scatterometer on QuikSCAT Mission and the Emerging Land and Ocean Applications

Spaceborne scatterometers are active microwave radar instruments designed to acquire near-simultaneous, spatially collocated measurements of the normalized radar backscattering cross section (sigma0) of the global surface from several azimuth and/or incidence angles. The primary objective of the scatterometer mission is to measure the near-surface wind speed and direction over the global ocean using sigma0 measurements together with a wind geophysical model function. However, since sigma0 measurements are collected globally all the time, sigma0 data can also be used for global land and ice applications. In this paper, we will first present the objectives of the QSCAT mission, the instrument design, and the unique features of the Ku-band scatterometer currently in operation, called SeaWinds on QuikSCAT (QSCAT). We will then present some emerging land and ocean applications of the QSCAT data, which include (1) global snow detection and monitoring, (2) melt region mapping on the Greenland ice sheet, (3) Monsoon flood detection and monitoring, (4) soil wetness application at large scale, and (5) hurricane monitoring and tracking.

Tsai, W.-Y.↗

Status of the Geostationary Spectrograph (GeoSpec) for Earth and Atmospheric Science Applications

GeoSpec will support future satellite mission concepts in the Atmospheric Sciences and in Land and Ocean Sciences by providing time-resolved measurements of both chemically linked atmospheric trace gas concentrations of important molecules such as O3, NO2, CH2O and SO2 and at the same time coastal and ocean pollution events, tidal effects, and the origin and evolution of aerosol plumes. The instrument design concept in development is a dual spectrograph covering the WMS wavelength region of 310-500 nm and the VIS/NIR wavelength region of 480-900 nm coupled to all reflective telescope and high sensitivity PIN/CMOS area detector. The goal of the project is to demonstrate a system capable of making moderate spatial resolution (750 meters at nadir) hyperspectral measurements (0.6 to 1.2 nm resolution) from a geostationary orbit. This would enable studies of time-varying pollution and coastal change processes with a temporal resolution of 5 minutes on a regional scale to 1 hour on a continental scale. Other spatial resolutions can be supported by varying the focal length of the input telescope. Scientific rationale and instrument design and status will be presented.

Janz, Scott↗

The solar ultraviolet spectral irradiance monitor (SUSIM) experiment on board the Upper Atmosphere Research Satellite (UARS)

The state of solar ultraviolet irradiance measurements in 1978, when NASA requested proposals for a new generation of solar ultraviolet monitors to be flown on the Upper Atmosphere Research Satellite (UARS), is described. To overcome the radiometric uncertainties that plagued the measurements at this time, the solar ultraviolet spectral irradiance monitor (SUSIM) instrument design included in-flight calibration light sources and multichannel photometers. Both are aimed at achieving a maximum precision of the SUSIM measurements over a long period of time, e.g., one solar cycle. The design of the SUSIM-UARS instrument is compared with the original design specifications for the UARS instruments. Details including optical train, filters, detectors, and contamination precautions are described. Also discussed are the SUSIM-UARS preflight calibration and characterization, as well as the results of the inflight performance of the instrument during the first 3 months of operation. Finally, flight operations, observation strategy, and data reduction schemes are outlined.

Brueckner, G. E.↗

A Regional CO2 Observing System Simulation Experiment for the ASCENDS Satellite Mission

Top-down estimates of the spatiotemporal variations in emissions and uptake of CO2 will benefit from the increasing measurement density brought by recent and future additions to the suite of in situ and remote CO2 measurement platforms. In particular, the planned NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) satellite mission will provide greater coverage in cloudy regions, at high latitudes, and at night than passive satellite systems, as well as high precision and accuracy. In a novel approach to quantifying the ability of satellite column measurements to constrain CO2 fluxes, we use a portable library of footprints (surface influence functions) generated by the WRF-STILT Lagrangian transport model in a regional Bayesian synthesis inversion. The regional Lagrangian framework is well suited to make use of ASCENDS observations to constrain fluxes at high resolution, in this case at 1 degree latitude x 1 degree longitude and weekly for North America. We consider random measurement errors only, modeled as a function of mission and instrument design specifications along with realistic atmospheric and surface conditions. We find that the ASCENDS observations could potentially reduce flux uncertainties substantially at biome and finer scales. At the 1 degree x 1 degree, weekly scale, the largest uncertainty reductions, on the order of 50 percent, occur where and when there is good coverage by observations with low measurement errors and the a priori uncertainties are large. Uncertainty reductions are smaller for a 1.57 micron candidate wavelength than for a 2.05 micron wavelength, and are smaller for the higher of the two measurement error levels that we consider (1.0 ppm vs. 0.5 ppm clear-sky error at Railroad Valley, Nevada). Uncertainty reductions at the annual, biome scale range from 40 percent to 75 percent across our four instrument design cases, and from 65 percent to 85 percent for the continent as a whole. Our uncertainty reductions at various scales are substantially smaller than those from a global ASCENDS inversion on a coarser grid, demonstrating how quantitative results can depend on inversion methodology. The a posteriori flux uncertainties we obtain, ranging from 0.01 to 0.06 Pg C yr-1 across the biomes, would meet requirements for improved understanding of long-term carbon sinks suggested by a previous study.

remote sensing↗