Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrumentation: interferometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The Effects of the Local Environment on a Compact Radio Interferometer I: Cross-Coupling in the Tianlai Dish Pathfinder Array

The visibilities measured by radio astronomical interferometers include non-astronomical correlated signals that arise from the local environment of the array. These correlated signals are especially important in compact arrays such as those under development for 21cm intensity mapping. The amplitudes of the contaminated visibilities can exceed the expected 21cm signal and represent a significant systematic effect. We study the receiver noise radiated by antennas in compact arrays and develop a model for how it couples to other antennas. We apply the model to the Tianlai Dish Pathfinder Array (TDPA), a compact array of 16, 6-m dish antennas. The coupling model includes electromagnetic simulations, measurements with a network analyzer, and measurements of the noise of the receivers. We compare the model to drift-scan observations with the array and set requirements on the level of antenna cross-coupling for 21cm intensity mapping instruments. Here, we find that for the TDPA, cross-coupling would have to be reduced by three orders of magnitude in order to contribute negligibly to the visibilities.

21cm intensity mapping↗

Differently Structured Fabry-Perot Interferometers for Gas Pressure Monitoring

In this study, we present an experimental comparison of gas pressure sensors based on differently structured extrinsic Fabry-Pérot interferometers (FPIs). Different fabrication techniques were adopted to foster the practical realization of these sensors. A novel photonic crystal fiber (PCF) based FPI with an angle cleaved end face that enables gas to easily flow in and out of the cavity while also avoiding the mixed signal from the cascaded structure is also presented. We measured helium gas pressure from 0.1 MPa (atmospheric pressure) to 5 MPa at room temperature and obtained a gas pressure sensitivity coefficient of 0.5±0.01 nm/MPa. Furthermore, the gas pressure sensitivities are numerically analyzed to validate the experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-inductive plasma vertical position measurement for the 1056 s discharge on EAST

Vertical position stability plays a crucial role in maintaining safe and reliable plasma operation for long-pulse fusion devices. In general, the vertical position is measured by using inductive magnetic coils installed inside the vacuum vessel; however, the integration drift effects are inherent for steady-state or long-pulse plasma operation. Further, developing a non-magnetic approach provides a fusion reactor-relevant steady-state solution that avoids the negative impact of integration drift. In this paper, we compare the non-inductively determined vertical position achieved by line-integrated interferometer and polarimeter measurements to that employing an inductive flux loop for a 1056 s discharge recently achieved on EAST (Experimental Advanced Superconducting Tokamak). Experimental results show that the non-inductive measurement is more robust than flux loops after 300 s if the integrator is not reset to suppress integrator drift. Real-time vertical position control using the non-inductive system is proposed for the next EAST experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Faraday Michelson Interferometers for Signal Demodulation of Fiber-Optic Sensors

We developed an all-fiber-based optical demodulator for the signal interrogation of low-coherence fiber-optic Fabry–Perot interferometric sensors. The optical demodulator consists of a Michelson interferometer implemented by using a 3×3 fiber coupler and two fiber-coupled Faraday reflectors with tunable fiber delay lines. The demodulator's output contains two optical interference signals with a constant phase shift and the output shows no sensitivity to the polarization variation in the light source or fibers. A digital phase recovery algorithm is used to extract the measurand information from the phase-shifted signals at high accuracy, high dynamic range, and high stability. The optical demodulator has been applied to the measurement of high-frequency vibrations and strains using fiber-optic sensors.

47 OTHER INSTRUMENTATION↗

Discriminative Dimensionality Reduction using Deep Neural Networks for Clustering of LIGO Data

In this paper, leveraging the capabilities of neural networks for modeling the non-linearities that exist in the data, we propose several models that can project data into a low dimensional, discriminative, and smooth manifold. The proposed models can transfer knowledge from the domain of known classes to a new domain where the classes are unknown. A clustering algorithm is further applied in the new domain to find potentially new classes from the pool of unlabeled data. The research problem and data for this paper originated from the Gravity Spy project which is a side project of Advanced Laser Interferometer Gravitational-wave Observatory (LIGO). The LIGO project aims at detecting cosmic gravitational waves using huge detectors. However non-cosmic, non-Gaussian disturbances known as "glitches", show up in gravitational-wave data of LIGO. This is undesirable as it creates problems for the gravitational wave detection process. Gravity Spy aids in glitch identification with the purpose of understanding their origin. Since new types of glitches appear over time, one of the objective of Gravity Spy is to create new glitch classes. Towards this task, we offer a methodology in this paper to accomplish this.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementing Faraday effect measurement constraints into the Grad–Shafranov equilibrium fitting code EFIT

A new tool for the exploration and diagnosis of the internal magnetic field of plasmas in the DIII-D tokamak in the form of a constraint on the EFIT (Equilibrium Fitting) Grad–Shafranov code based on the Faraday-effect Radial Interferometer-Polarimeter (RIP) diagnostic is presented, including description, verification, and sample application. The physics underlying the diagnostic and its implementation into EFIT are discussed, and the results showing the verification of the model are given, and the model’s limitations are discussed. The influence of the diagnostic’s input on the resulting equilibrium parameters is characterized. Furthermore, the effect of electron density profile refinement is evaluated and found to be negligible. A sample application of the diagnostic is shown, indicating that the RIP constraint has similar effects on the equilibrium as motional Stark effect constraints do.

47 OTHER INSTRUMENTATION↗

Real-time jitter correction in a photonic analog-to-digital converter

A real-time jitter meter is used to measure and digitally sample the pulse-to-pulse timing error in a laser pulse train. The jitter meter is self-referenced using a single-pulse delay line interferometer and measures timing jitter using optical heterodyne detection between two frequency channels of the pulse train. Jitter sensitivity down to 3×10 -10 fs 2 /Hz at 500 MHz has been demonstrated with a pulse-to-pulse noise floor of 1.6 fs. Furthermore, as a proof of principle, the digital correction of the output of a high-frequency photonic analog-to-digital converter (PADC) is demonstrated with an emulated jitter signal. Up to 23 dB of jitter correction, down to the noise floor of the PADC, is accomplished with radio-frequency modulation up to 40 GHz.

47 OTHER INSTRUMENTATION↗

The Fermilab Holometer: A program to measure Planck scale indeterminacy

We propose an experiment at Fermilab to study a conjectured effect called "holographic noise" that may arise from new Planck scale physics: the measured positions of bodies may wander randomly from ideal geodesics of classical relativity, in measurement-dependent directions, by about a Planck length per Planck time. The experiment will search for this holographic jitter in the relation of mass-energy and space-time by looking for correlated phase noise between two neighboring 40 meter interferometers. The goal of the experiment is to provide convincing evidence for or against the hypothesis that relative transverse positions of bodies display this particular new kind of quantum noise, whose power spectrum is independent of frequency and has a spectral density determined only by the Planck time. A positive result of the experiment would be a major step forward in understanding the emergence of space time and mass-energy from a unified theory of spacetime and quantum mechanics. A negative result will impact the macroscopic interpretation of unified theories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Impact of Nonzenith Elevation Angles on Ground-Based Infrared Thermodynamic Retrievals

Observing thermodynamic profiles within the planetary boundary layer is essential to understanding and predicting atmospheric phenomena because of the significant exchange of sensible and latent heat between the land and atmosphere within that layer. The Atmospheric Emitted Radiance Interferometer (AERI) is a ground-based infrared spectrometer used to obtain the vertical profiles of temperature and water vapor mixing ratio. Most AERIs are only capable of zenith views, although the Marine AERI (M-AERI) has a design that allows it to view various elevation angles. In this study, we quantify the improvement in the information content and accuracy of the retrieved profiles when nonzenith angles are included, as is common with microwave radiometer profilers. The impacts of the additional scan angles are quantified through both a synthetic study and with M-AERI observations from the ARM Cloud Aerosol Precipitation Experiment (ACAPEX) campaign. Furthermore, the simulation study shows that low elevation angles contain more information content for temperature whereas high elevation angles have more information content for water vapor. Outside of very humid environments, the addition of low elevation angles also results in lower root-mean-square errors when compared with high angles for both temperature and water vapor mixing ratio, although this is primarily a result of averaging multiple observations together to reduce instrument noise. Real-world results from the ACAPEX dataset indicate similar results as were found for the simulation study, although not all predicted benefits are realized because of the small sample size and observational uncertainties.

54 ENVIRONMENTAL SCIENCES↗

Astrometric gravitational-wave detection via stellar interferometry

Here, we evaluate the potential for gravitational-wave (GW) detection in the frequency band from 10 nHz to 1 μ Hz using extremely high-precision astrometry of a small number of stars. In particular, we argue that nonmagnetic, photometrically stable, hot white dwarfs (WD) located at ~kpc distances may be optimal targets for this approach. Previous studies of astrometric GW detection have focused on the potential for less precise surveys of large numbers of stars; our work provides an alternative optimization approach to this problem. Interesting GW sources in this band are expected at characteristic strains around h c ~10 -17 × (μHz/ $f$ GW ). The astrometric angular precision required to see these sources is Δθ~h c after integrating for a time T~1/$f$GW. We show that jitter in the photometric center of WD of this type due to starspots is bounded to be small enough to permit this high-precision, small-N approach. We discuss possible noise arising from stellar reflex motion induced by orbiting objects and show how it can be mitigated. The only plausible technology able to achieve the requisite astrometric precision is a space-based stellar interferometer. Such a future mission with few-meter-scale collecting dishes and baselines of $\mathscr{O}$(100 km ) is sufficient to achieve the target precision. This collector size is broadly in line with the collectors proposed for some formation-flown, space-based astrometer or optical synthetic-aperture imaging-array concepts proposed for other science reasons. The proposed baseline is however somewhat larger than the km-scale baselines discussed for those concepts, but we see no fundamental technical obstacle to utilizing such baselines. A mission of this type thus also holds the promise of being one of the few ways to access interesting GW sources in this band.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monolithic Spatial Heterodyne Raman Spectrometers (mSHRS): Toward highly miniature chemical sensors for deployment on moving platforms (Final Report, Phase I)

This report covers phase 1 (year 1) of the mSHRS project. Our ultimate long-term goal is to develop highly miniature Raman analyzers, known as spatial heterodyne Raman spectrometers (SHRS), that are deployable as in-situ chemical sensors on moving platforms. During Phase I (FY19/20) funding, our team focused our efforts solely on the key innovation needed toward realizing that goal: the development of the monolithic interferometer comprising the beam splitter and gratings with the appropriate design parameters and tolerances to enable Raman interferometry. We successfully developed and characterized the performance of the first monolithic SHRS devices including a monolithic version that incorporates field-widened optics. Our solid-state design approach integrated all optical components as a single monolithic unit for maintaining precise optical alignment during sensor operation, a requirement for operating in a vibration prone environment. This project has two principle activities: (1) Design and fabricate monolithic SHRS devices (i.e. monolithic device task) and (2) characterize the mSHRS devices in terms of performance (i.e. the Monolithic SHRS characterization task).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MAGIS-100 environmental characterization and noise analysis

We investigate and analyze site specific systematics for the MAGIS-100 atomic interferometry experiment at Fermi National Accelerator Laboratory. As atom interferometers move out of the laboratory environment passive and active mitigation for noise sources must be implemented. To inform the research and development of the experiment design, we measure ambient temperature, humidity, and vibrations of the installation site. We find that temperature fluctuations will necessitate enclosures for critical subsystems and a temperature controlled laser room for the laser system. We also measure and analyze the vibration spectrum above and below ground for the installation site. The seismic vibration effect of gravity gradient noise is also modeled using input from a low-noise seismometer at multiple locations and a mitigation scheme is studied using a stochastic simulation and characterized by a suppression factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Source-agnostic gravitational-wave detection with recurrent autoencoders

Abstract We present an application of anomaly detection techniques based on deep recurrent autoencoders (AEs) to the problem of detecting gravitational wave (GW) signals in laser interferometers. Trained on noise data, this class of algorithms could detect signals using an unsupervised strategy, i.e. without targeting a specific kind of source. We develop a custom architecture to analyze the data from two interferometers. We compare the obtained performance to that obtained with other AE architectures and with a convolutional classifier. The unsupervised nature of the proposed strategy comes with a cost in terms of accuracy, when compared to more traditional supervised techniques. On the other hand, there is a qualitative gain in generalizing the experimental sensitivity beyond the ensemble of pre-computed signal templates. The recurrent AE outperforms other AEs based on different architectures. The class of recurrent AEs presented in this paper could complement the search strategy employed for GW detection and extend the discovery reach of the ongoing detection campaigns.

47 OTHER INSTRUMENTATION↗

Imaging velocity interferometer system for any reflector (VISAR) diagnostics for high energy density sciences

Two variants of optical imaging velocimetry, specifically the one-dimensional streaked line-imaging and the two-dimensional time-resolved area-imaging versions of the Velocity Interferometer System for Any Reflector (VISAR), have become important diagnostics in high energy density sciences, including inertial confinement fusion and dynamic compression of condensed matter. Here, we give a brief review of the historical development of these techniques, then describe the current implementations at major high energy density (HED) facilities worldwide, including the OMEGA Laser Facility and the National Ignition Facility. We illustrate the versatility and power of these techniques by reviewing diverse applications of imaging VISARs for gas-gun and laser-driven dynamic compression experiments for materials science, shock physics, condensed matter physics, chemical physics, plasma physics, planetary science and astronomy, as well as a broad range of HED experiments and laser-driven inertial confinement fusion research.

47 OTHER INSTRUMENTATION↗

Horn Location Sensors for LBNF

The Horn Location Sensor (HLS) system—named for the magnetic focusing horns it monitors, along with other critical beamline elements – is a high-precision alignment system developed for the Long-Baseline Neutrino Facility (LBNF) to support the Deep Underground Neutrino Experiment (DUNE). With minimal maintenance, the HLS can operate reliably in environments with high radiation, and it ensures that key components such as the protective baffle, focusing horns, and beam position monitors are aligned correctly – each essential for maintaining one of the world’s most intense muon-neutrino beams. A high-precision hydrostatic level sensor, a linear variable differential transformer, and INVAR rods are all used in the system to monitor vertical motion and tilt with sub-millimeter accuracy. A novel Sweep Tracker interferometer enhances calibration fidelity by correcting for non-linearities in laser wavelength and scan rate in real time. A critical part of DUNE’s precision alignment and flux prediction requirements, the HLS system initially supports beam power of up to 1.2 MW and can be upgraded to 2.4 MW.

Frequency scanning interferometry↗

Gain balanced nonlinear optical interferometer

A nonlinear fiber interferometer is disclosed suitable for fiber sensor and other applications. A first nonlinear fiber section amplifies probe and conjugate sidebands of a pump through four-wave mixing. A second section introduces a phase shift to be measured, for example from a sensor. A third nonlinear fiber section amplifies with phase-sensitive gain to increase signal-to-noise ratio. Based on phase-sensitive output power of probe and/or conjugate components, the phase shift can be measured. Superior performance can be obtained by balancing gain between the (first and third) nonlinear sections. Non-fiber, for example photonic integrated circuit, embodiments are disclosed. Differential sensing, alternative detection schemes, sensing applications, associated methods, and other variations are disclosed.

42 ENGINEERING↗

Fast wave interferometer for ion density measurement on DIII-D

=A fast wave interferometer (FWI), which can measure ion mass density, has been developed on DIII-D for its use on future fusion reactors, as well as for the study of ion behavior in current plasma devices. The frequency of the fast waves used for the FWI is around 60 MHz, and require antennas and coaxial cables or waveguides, which, unlike traditional mirror-based optical interferometers, are less susceptible to neutron/gamma-ray radiation and are relatively immune to impurity deposition and erosion as well as alignment issues. The bulk ion density evaluated using FWI show good agreement with that derived from CO 2 interferometry within about 15%. When the ion mass density measurement by FWI is combined with an electron density measurement from CO 2 interferometry, Z eff measurements are also enabled and are in agreement with those from visible Bremsstrahlung measurements. Additionally, large-bandwidth FWI measurements clearly resolve 10–100 kHz coherent modes and demonstrate its potential as a core fluctuation diagnostic, sensitive to both magnetic and ion density perturbations.

Instruments & Instrumentation↗