Search NASA⌕ Search

SEARCH · Search NASA

Results for “intact samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Pods: a Powder Delivery System for Mars In-situ Organic, Mineralogic and Isotopic Analysis Instruments

Many Mars in situ instruments require fine-grained high-fidelity samples of rocks or soil. Included are instruments for the determination of mineralogy as well as organic and isotopic chemistry. Powder can be obtained as a primary objective of a sample collection system (e.g., by collecting powder as a surface is abraded by a rotary abrasion tool (RAT)), or as a secondary objective (e.g, by collecting drill powder as a core is drilled). In the latter case, a properly designed system could be used to monitor drilling in real time as well as to deliver powder to analytical instruments which would perform complementary analyses to those later performed on the intact core. In addition, once a core or other sample is collected, a system that could transfer intelligently collected subsamples of power from the intact core to a suite of analytical instruments would be highly desirable. We have conceptualized, developed and tested a breadboard Powder Delivery System (PoDS) intended to satisfy the collection, processing and distribution requirements of powder samples for Mars in-situ mineralogic, organic and isotopic measurement instruments.

Saha, C. P.↗

Mechanism of Enhanced Carbon Substitution in CNT-MgB{sub 2} Superconductor Composite Using Ball Milling in a Methanol Medium: Positive Role of Boron Oxide

In the present work, we report on the role of the methanol medium and ball-milling time in the substitution of carbon in carbon nanotube CNT-MgB{sub 2} superconductors. In our samples, we find that the CNTs are intact and well dispersed. However, the liquid medium (methanol) used for dispersion of the constituent materials is also acting as a source of C for substitution. However, the substitution of C from methanol is not direct; rather, B{sub 2}O{sub 3}, which had been considered as just an impurity, plays a positive role in binding the methanol molecules to the surface of B. The detailed mechanism of methanol absorption and the role of B{sub 2}O{sub 3} and ball-milling time are presented here. In addition, we present the J{sub C}(H, T) data, which show that approximately 3% of C substitution provides the best critical current density at 20 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NASA's Rodent Research Project: Validation of Capabilities for Conducting Long Duration Experiments in Space

Research using rodents is an essential tool for advancing biomedical research on Earth and in space. Prior rodent experiments on the Shuttle were limited by the short flight duration. The International Space Station (ISS) provides a new platform for conducting rodent experiments under long duration conditions. Rodent Research (RR)-1 was conducted to validate flight hardware, operations, and science capabilities that were developed at the NASA Ames Research Center. Twenty C57BL6J adult female mice were launched on Sept 21, 2014 in a Dragon Capsule (SpaceX-4), then transferred to the ISS for a total time of 21-22 days (10 commercial mice) or 37 days (10 validation mice). Tissues collected on-orbit were either rapidly frozen or preserved in RNAlater at -80C (n2group) until their return to Earth. Remaining carcasses on-orbit were rapidly frozen for dissection post-flight. The three controls groups at Kennedy Space Center consisted of: Basal mice euthanized at the time of launch, Vivarium controls housed in standard cages, and Ground Controls (GC) housed in flight hardware within an environmental chamber. Upon return to Earth, there were no differences in body weights between Flight (FLT) and GC at the end of the 37 days in space. Liver enzyme activity levels of FLT mice and all control mice were similar in magnitude to those of the samples that were processed under optimal conditions in the laboratory. Liver samples dissected on-orbit yielded high quality RNA (RIN8.99+-0.59, n7). Liver samples dissected post-flight from the intact, frozen FLT carcasses yielded RIN of 7.27 +- 0.52 (n6). Additionally, wet weights of various tissues were measured. Adrenal glands and spleen showed no significant differences in FLT compared to GC although thymus and livers weights were significantly greater in FLT compared to GC. Over 3,000 tissue aliquots collected post-flight from the four groups of mice were deposited into the Ames Life Science Data Archives for future Biospecimen Sharing Program. Together, the RR validation flight successfully demonstrates the capability to support long-duration experimentation on the ISS to achieve both basic science and biomedical objectives.

spaceflight↗

Coupling detergent lysis/clean-up methodology with intact protein fractionation for enhanced proteome characterization

The expanding use of surfactants for proteome sample preparations has prompted the need to systematically optimize the application and removal of these MS-deleterious agents prior to proteome measurements. Here we compare four different detergent clean-up methods (Trichloroacetic acid (TCA) precipitation, Chloroform/Methanol/Water (CMW) extraction, commercial detergent removal spin column method (DRS) and filter-aided sample preparation(FASP)) with respect to varying amounts of protein biomass in the samples, and provide efficiency benchmarks with respect to protein, peptide, and spectral identifications for each method. Our results show that for protein limited samples, FASP outperforms the other three clean-up methods, while at high protein amount all the methods are comparable. This information was used in a dual strategy of comparing molecular weight based fractionated and unfractionated lysates from three increasingly complex samples (Escherichia coli, a five microbial isolate mixture, and a natural microbial community groundwater sample), which were all lysed with SDS and cleaned up using FASP. The two approaches complemented each other by enhancing the number of protein identifications by 8%-25% across the three samples and provided broad pathway coverage.

FASP↗

ON THE INFLUENCE OF COLD WORK ON RESISTIVITY VARIATIONS WITH THERMAL EXPOSURE IN IN-718 NICKEL-BASE SUPERALLOY

In nickel-base superalloys, irreversible electrical conductivity changes occur above a transition temperature where thermally-activated microstructural evolution initiates. The electrical conductivity first decreases above about 450 deg. C then increases above 600 deg. C. However, the presence of plastic deformation results in accelerated microstructure evolution at an earlier transition temperature. It was recently suggested that this well-known phenomenon might explain the notable conductivity difference between the peened near-surface part and the intact part at sufficiently large depth in surface-treated specimens. The influence of cold work on the electrical conductivity change with thermal exposure offers a probable answer to one of the main remaining questions in eddy current residual stress assessment, namely unusually fast and occasionally even non-monotonic decay of the apparent eddy current conductivity (AECC) change that was observed at temperatures as low as 400 deg. C. To validate this explanation, the present study investigates the influence of cold work on low-frequency Alternating Current Potential Drop (ACPD) resistivity variations with thermal exposure. In-situ resistivity monitoring was conducted throughout various heating cycles using the ACPD technique. IN-718 nickel-base superalloy specimens with different levels of cold work were exposed to gradually increasing peak temperatures from 400 deg. C to 800 deg. C. The results indicate that the initial irreversible rise in resistivity is approximately one order of magnitude higher and occurs at about 50 deg. C lower temperature in cold-worked samples of 30% plastic strain than in the intact material.

36 MATERIALS SCIENCE↗

Atomic Force Microscopy Thermally-Assisted Microsampling with Atmospheric Pressure Temperature Ramped Thermal Desorption/Ionization-Mass Spectrometry Analysis

The use of atomic force microscopy controlled nano-thermal analysis probes for reproducible spatially resolved thermally-assisted sampling of micrometer-sized areas (ca. 11 m 17 m wide 2.4 m deep) from relatively low number average molecular weight (M n < 3000) polydisperse thin films of poly(2-vinylpyridine) (P2VP) is presented. Following sampling, the nano-thermal analysis probes were moved up from the surface and the probe temperature ramped to liberate the sampled materials into the gas phase for atmospheric pressure chemical ionization and mass spectrometric analysis. Furthermore, the procedure and mechanism for material pickup, the sampling reproducibility and sampling size are discussed and the oligomer distribution information available from slow temperature ramps versus ballistic temperature jumps is presented. For the M n = 970 P2VP, the Mn and polydispersity index determined from the mass spectrometric data were in line with both the label values from the sample supplier and the value calculated from the simple infusion of a solution of polymer into the commercial atmospheric pressure chemical ionization source on this mass spectrometer. With a P2VP sample of higher Mn (M n = 2070 and 2970), intact oligomers were still observed (as high as m/z 2793 corresponding to the 26-mer), but a significant abundance of thermolysis products were also observed. In addition, the capability for confident identification of the individual oligomers by slowly ramping the probe temperature and collecting data dependent tandem mass spectra was also demonstrated. We also discuss the material type limits to the current sampling and analysis approach as well as possible improvements in nano-thermal analysis probe design to enable smaller area sampling and to enable controlled temperature ramps beyond the present upper limit of about 415°C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Brazing Alloys Indicate Turbomachinery Temperatures

Foils serve as consumable thermometers. Stainless-steel tab with circular window holds brazing-foil sample in place. Tab tacked to object to be tested with capacitive-discharge spot welder operating in range 10 + 1 joules. After measurements, tabs and samples chiseled off, leaving tested object fairly well intact. Technique used on objects made of alloys with iron, nickel, or cobalt as principal ingredients.

Schlaff, J. W.↗

Sensitive Top-Down Proteomics Analysis of a Low Number of Mammalian Cells Using a Nanodroplet Sample Processing Platform

Top-down proteomics is a powerful tool for characterizing genetic variations and post-translational modifications at intact protein level. That being said, one significant technical gap of top-down proteomics is the inability to analyze low amount of biological samples, which limits its access to isolated rare cells, fine-needle aspiration biopsies, and tissue substructures. Herein, we developed an ultrasensitive top-down platform by incorporating a microfluidic sample preparation system, termed nanoPOTS (Nanodroplet Processing in One pot for Trace Samples), into a top-down proteomics workflow. A unique combination of a nonionic detergent dodecyl-ß-D-maltopyranoside (DDM) with urea as protein extraction buffer significantly improved both protein extraction efficiency and sample recovery. We hypothesize that the DDM detergent improves protein recovery by efficiently reducing non-specific adsorption of intact proteins on container surfaces, while urea serves as a strong denaturant to disrupt noncovalent complexes and release intact proteins for downstream analysis. The nanoPOTS-based top-down platform reproducibly and quantitatively identified ~170 to ~620 proteoforms from ~70 to ~770 HeLa cells containing ~10 to ~115 ng of total protein. A variety of post-translational modifications including acetylation, myristoylation, and iron binding were identified using only less than 800 cells. We anticipate the nanoPOTS top-down proteomics platform will be broadly applicable in biomedical researches, particularly where clinical specimens are not available in amounts amenable to standard workflows.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Linear Ion Trap Mass Spectrometer (LITMS) Investigation for Future Planetary Surface Missions

Future surface missions to Mars and other planetary bodies will benefit from continued advances in miniature sensor and sample handling technologies that enable high-performance chemical analyses of natural samples. Fine-scale (approx.1 mm and below) analyses of rock surfaces and interiors, such as exposed on a drill core, will permit (1) the detection of habitability markers including complex organics in association with their original depositional environment, and (2) the characterization of successive layers and gradients that can reveal the time-evolution of those environments. In particular, if broad-based and highly-sensitive mass spectrometry techniques could be brought to such scales, the resulting planetary science capability would be truly powerful. The Linear Ion Trap Mass Spectrometer (LITMS) investigation is designed to conduct fine-scale organic and inorganic analyses of short (approx.5-10 cm) rock cores such as could be acquired by a planetary lander or rover arm-based drill. LITMS combines both pyrolysis/gas chromatograph mass spectrometry (GCMS) of sub-sampled core fines, and laser desorption mass spectrometry (LDMS) of the intact core surface, using a common mass analyzer, enhanced from the design used in the Mars Organic Molecule Analyzer (MOMA) instrument on the 2018 ExoMars rover. LITMS additionally features developments based on the Sample Analysis at Mars (SAM) investigation on MSL and recent NASA-funded prototype efforts in laser mass spectrometry, pyrolysis, and precision subsampling. LITMS brings these combined capabilities to achieve its four measurement objectives: (1) Organics: Broad Survey Detect organic molecules over a wide range of molecular weight, volatility, electronegativity, concentration, and host mineralogy. (2) Organic: Molecular Structure Characterize internal molecular structure to identify individual compounds, and reveal functionalization and processing. (3) Inorganic Host Environment Assess the local chemical/mineralogical makeup of organic host phases to help determine deposition and preservation factors. (4) Chemical Stratigraphy Analyze the fine spatial distribution and variation of key species with depth.

Mars↗

Cryogenic specimens for nanoscale characterization of solid–liquid interfaces

We report new cryogenic characterization techniques for exploring the nanoscale structure and chemistry of intact solid–liquid interfaces have recently been developed. These techniques provide high-resolution information about buried interfaces from large samples or devices that cannot be obtained by other means. These advancements were enabled by the development of instrumentation for cryogenic focused ion beam liftout, which allows intact solid–liquid interfaces to be extracted from large samples and thinned to electron-transparent thicknesses for characterization by cryogenic scanning transmission electron microscopy or atom probe tomography. Future implementation of these techniques will complement current strides in imaging of materials in fluid environments by in situ liquid-phase electron microscopy, providing a more complete understanding of the morphology, surface chemistry, and dynamic processes that occur at solid–liquid interfaces.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Progression of soot cake layer properties during the systematic regeneration of diesel particulate filters measured with neutron tomography

Although particulate filters (PFs) have been a key component of the emission control system for modern diesel engines, there remain significant questions about the basic regeneration behavior of the filters and how it changes with accumulation of increasing soot layers. This effort describes a systematic deposition and regeneration of particulate matter in 25-mm diameter × 76-mm long wall-flow PFs composed of silicon carbide (SiC) material. The initial soot distributions were analyzed for soot cake thickness using a nondestructive neutron imaging technique. With the PFs intact, it was then possible to sequentially regenerate the samples and reanalyze them, which was performed after nominal 20, 50, and 70 % regenerations. The loaded samples show a relatively uniform distribution of particulate with an increasing soot cake thickness and nearly identical initial density of 70 mg/cm 3 . Throughout regeneration, the soot cake thickness initially decreases significantly while the density increases to 80–90 mg/cm 3 . After ~50 % regeneration, the soot cake thickness stays relatively constant, but instead, the density decreases as pores open up in the layer (~35 mg/cm 3 at 70 % regeneration). Here, complete regeneration initially occurs at the rear of the PF channels. With this information, a conceptual model of the regeneration is proposed.

54 ENVIRONMENTAL SCIENCES↗

Hybridized polymer matrix composites

Design approaches and materials are described from which are fabricated pyrostatic graphite/epoxy (Gr/Ep) laminates that show improved retention of graphite particulates when subjected to burning. Sixteen hybridized plus two standard Gr/Ep laminates were designed, fabricated, and tested in an effort to eliminate the release of carbon (graphite) fiber particles from burned/burning, mechanically disturbed samples. The term pyrostatic is defined as meaning mechanically intact in the presence of fire. Graphite particulate retentive laminates were constructed whose constituent materials, cost of fabrication, and physical and mechanical properties were not significantly different from existing Gr/Ep composites. All but one laminate (a Celion graphite/bis-maleimide polyimide) were based on an off-the-shelf Gr/Ep, the AS-1/3501-5A system. Of the 16 candidates studied, four thin (10-ply) and four thick (50-ply) hybridized composites are recommended.

London, A.↗

Voltage-Current Behavior of a Superconducting STAR ® Wire in a 6-Around-1 Cable Configuration

A 6-around-1 transposed cable using superconducting STAR® wires can be useful for future circular collider applications. We made three cable samples using single STAR® wires with a diameter of 1.3 mm. The first two samples, made with a cabling machine, used STAR® wires consisting of a 0.7 mm diameter Nb-Ti core. The third cable sample was manually wound and used a STAR® wire made with a 0.81 mm diameter Cu core. The first sample showed severe degradation after the cable was bent to a 75 mm radius. The current-carrying capability of the innermost and outermost REBCO tapes in the STAR® wire degraded by 42% to 98% and the middle REBCO tapes remained intact. This was also the case for the second and straight cable sample. After fabrication of the third cable sample, we observed only about 5% reduction in the current along the wire, measured at different locations inside the terminations. Finally, the results indicate that the differences in architecture or fabrication of the STAR® wires could have caused differences in critical current retention after cabling.

6-around-1 cable↗

Development of self-healing films to improve durability of VIPs by in-situ remediation of film defects

The integrity of the VIP barrier film or envelope is a critical for maintaining the ultra-low thermal conductivity of VIPs. Here, the concept of a self-healing barrier film is described and demonstrated. The self-healing concept is based on an addition reaction between two chemicals, without the need for any external stimuli. The chemicals are incorporated as coatings in a multi-layered film and are initially kept separate with a partition layer. In case of damage, the chemicals would mix, react and heal the damage. Tests of small-scale film samples in a custom vacuum pump apparatus by puncturing the samples demonstrated the proof-of-concept. The tests indicated that the chemicals reacted and healed the puncture immediately to maintain the system vacuum. The intact and punctured self-healing films showed near-identical behaviour, while a control sample allowed the pressure to rise to atmospheric levels on puncturing. Development of films with coated chemicals using tape casting and slot die coating methods is also described. These are low-cost and mature technologies, which are commonly used by various industries. The proposed chemicals are low-cost, commercially available materials. Thus, the self-healing technology is expected to be inexpensive and scalable.

Biswas, Kaushik↗

Contaminant Leaching From Intact Saltstone Monoliths - 17517

At the Department of Energy's (DOE's) Savannah River Site (SRS) chemically reducing materials, such as blast furnace slag (BFS), are added to grout formulations mixed with low-level radioactive salt solution in order to enhance the attenuation of redox sensitive contaminants (e.g., technetium-99 (Tc-99)). The resulting cementitious material, known as saltstone, is deposited in a series of concrete vaults for permanent disposal at the Saltstone Disposal Facility (SDF). Under oxidizing conditions, Tc persists as an anion in the +7 oxidation state, i.e., pertechnetate (TcO{sub 4}{sup -}), with very limited retention generally associated with amphoteric soil oxides. However, Tc(VII) is subject to chemical reduction to the +4 oxidation state, which is less soluble and mobile in the environment. Thus, chemically reducing grouts provide both a physical (i.e., low saturated hydraulic conductivities (K{sub sat}) that limit H{sub 2}O turnover and O{sub 2} exposure) and chemical barrier (i.e., residual reductive capacity) to contaminant release. However, many of the previous experiments evaluating the ability of saltstone to chemically reduce and immobilize Tc have been conducted using ground saltstone materials as sorbents, a practice that is likely to reduce the moisture level in the material, enhance exposure to O{sub 2} and alter sorbent properties in an unpredictable manner. Therefore, the objective of the current study was to evaluate contaminant leaching from intact monoliths that better represent the initial physical and chemical state of saltstone within the SDF disposal units. For the current study, saltstone simulants were produced utilizing SRR prescribed formulations: initial batches were spiked with rhenium (Re) to serve as nonradioactive analog for Tc-99, and subsequent batches were spiked with Tc-99 for comparison. The relative concentrations of I, Re and Tc-99 in the salt-waste simulants were consistent with the average concentrations of I-129 and Tc-99 in the low-level feed waste. In addition, SRR retrieved intact monoliths from Saltstone Disposal Unit (SDU) Cell 2A in 2015 for testing. Contaminant mass transfer rates for Tc-99 and other contaminants from spiked saltstone simulants and actual SDF saltstone samples were assessed using EPA Method 1315, Mass Transfer Rates of Constituents in Monolithic or Compacted Granular Materials Using a Semi-Dynamic Tank Leaching Procedure. This method was recently adopted for evaluating contaminant leaching from intact monolithic materials. Given the importance of redox speciation in controlling the mobility of Tc-99, the EPA mass transfer tests for the spiked simulants were initially conducted using leachates in equilibrium with three different test atmospheres: (1) oxic, (2) anoxic, and (3) anoxic reducing. Nitrate (NO{sub 3}{sup -}) leaching was evaluated as a poorly retained waste constituent. The leaching behavior of cesium-137 (Cs-137), representing about 98% of the initial radioactivity of the saltstone, was also evaluated for the SDU-extracted samples. Results from Method 1315 were also compared to a novel Dynamic Leaching Method (DLM) in which a flexible-wall permeameter was used to achieve saturated leaching under an elevated hydraulic gradient in an effort to evaluate the persistence of reductive capacity and subsequent changes in contaminant partitioning within intact saltstone monoliths. The composition of the chemical leachates from both tests was thoroughly analyzed in an effort to identify potential solid phases controlling contaminant partitioning through geochemical modeling. For the EPA 1315 tests using spiked simulants, Re leaching rates (and other poorly sorbing contaminants like NO{sub 3}{sup -} and iodine), as indicated by high effective diffusivities (D{sub e}) and low leachability indices (i.e. LI = - log[D{sub e}]), were much higher than Tc-99, which was attributed to poor initial reduction and/or rapid oxidation of Re, indicating that Re is a poor chemical analog for evaluating Tc partitioning under reducing conditions. Technetium-99 leaching rates for the spiked saltstone samples also appeared to be sensitive to the estimated reduction capacity of the dry feed materials used in making grout, a characteristic that can vary between different BFS sources. Technetium-99 leaching rates for the intact saltstone samples in the EPA 1315 test were quite similar, with less variability between the three test samples. This may be indicative of the longer curing time before the SDF samples were tested (∼3 years). Somewhat surprisingly, the leaching rates for Cs-137 from the SDF samples were generally lower than the poorly sorbing contaminants, NO{sub 3}{sup -} and iodine. For the DLM tests, Re leaching from spiked saltstone was much higher than observed for Tc-99, with rates similar to that of non-reactive grout constituents, consistent with EPA 1315 leaching rates. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Genesis Solar Wind Collector Cleaning Assessment: Update on 60336 Sample Case Study

To maximize the scientific return of Genesis Solar Wind return mission it is necessary to characterize and remove a crash-derived particle and thin film surface contamination. A small subset of Genesis mission collector fragments are being subjected to extensive study via various techniques. Here we present an update on the sample 60336, a Czochralski silicon (Si-CZ) based wafer from the bulk array (B/C). This sample has undergone multiple cleaning steps (see the table below): UPW spin wash, aggressive chemical cleanings (including aqua regia, hot xylene and RCA1), as well as optical and chemical (EDS, ToF-SIMS) imaging. Contamination appeared on the surface of 60336 after the initial 2007 UPW cleaning. Aqua regia and hot xylene treatment (8/13/2013) did little to remove contaminants. The sample was UPW cleaned for the third time and imaged (9/16/13). The UPW removed the dark stains that were visible on the sample. However, some features, like "the Flounder" (a large, 100 micron feature in Fig. 1b) appeared largely intact, resisting all previous cleaning efforts. These features were likely from mobilized adhesive, derived from the Post-It notes used to stabilize samples for transport from Utah after the hard landing. To remove this contamination, an RCA step 1 organic cleaning (RCA1) was employed. Although we are still uncertain on the nature of the Flounder and why it is resistant to UPW and aqua regia/hot xylene treatment, we have found RCA1 to be suitable for its removal. It is likely that the glue from sticky pads used during collector recovery may have been a source for resistant organic contamination [9]; however [8] shows that UPW reaction with crash-derived organic contamination does not make particle removal more difficult.

Goreva, Y. S.↗

Nanoscale patterning of graphene through femtosecond laser ablation

We report on nanometer-scale patterning of single layer graphene on SiO{sub 2}/Si substrate through femtosecond laser ablation. The pulse fluence is adjusted around the single-pulse ablation threshold of graphene. It is shown that, even though both SiO{sub 2} and Si have more absorption in the linear regime compared to graphene, the substrate can be kept intact during the process. This is achieved by scanning the sample under laser illumination at speeds yielding a few numbers of overlapping pulses at a certain point, thereby effectively shielding the substrate. By adjusting laser fluence and translation speed, 400 nm wide ablation channels could be achieved over 100 μm length. Raster scanning of the sample yields well-ordered periodic structures, provided that sufficient gap is left between channels. Nanoscale patterning of graphene without substrate damage is verified with Scanning Electron Microscope and Raman studies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comet coma sample return via Giotto II

A comet coma sample return is possible with a low-cost flyby mission. Collecting coma materials and returning them to earth can be accomplished in a free-return trajectory. Intact capture of coma dust, preserving the cometary dust mineralogy, is possible at low encounter speeds. Samples from a known cometary source can then be compared with the wealth of information on meteorites and interplanetary dust. Sample return via Giotto II is a unique, low-cost NASA/ESA cooperative opportunity. With ESA providing the Giotto spacecraft and payload and NASA the sample return capability, first-class science can be accomplished at a very low cost for both NASA and ESA. This paper focuses on the sample return aspects, including sample return objectives, sample collection techniques, experimental work to verify collection concepts, and some of the characteristics of the cometary targets for sample return.

Tsou, P.↗