Search NASA⌕ Search

SEARCH · Search NASA

Results for “integrated loads analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Dataset of mechanically induced thermal runaway measurement and severity level on Li-ion batteries

The deployment of Li-ion batteries covers a wide range of energy storage applications, from mobile phones, e-bikes, electric vehicles (EV) and stationary energy storage systems. However, safety issue such as thermal runaway is always one of the most important concerns to prevent Li-ion batteries from further market penetration. A standardized single-side indentation test protocol was developed to mechanically induce an internal short-circuit. The cell voltage, compressive load, indenter stroke, and temperature at the indentation point are measured in time series. The test data of each cell, along with cell parameters such as dimensions, mass, chemistry, state of charge (SOC), capacity, are integrated together to calculate a thermal runaway severity score from 0 to100. Complete data collection process including the original measured record, test method, severity score calculation scheme is presented in this article. The thermal runaway severity analysis and the more than 100 tested Li-ion battery records provide a good data source for further comparison and ranking of thermal runaway risks.

25 ENERGY STORAGE↗

Spatial Impacts of Electric Vehicle Charging on Power Grid Stability: A Downtown Atlanta Case Study

The rapid increase in electric vehicle (EV) charging demand poses a potential risk to power grid stability, particularly as the spatial distribution of this demand remains underexplored. Existing research often focuses on technical optimization models while overlooking the geographic and human dynamics that affect energy consumption. This study addresses this gap by incorporating mobility data to estimate both building energy use and EV charging demand while also considering geographic factors for a better understanding of grid load. Using agent-based simulations and the Open-Source Distribution System Simulator, the study evaluates the effect of various EV penetration scenarios on grid voltage and unbalance. The results show that, although voltage remains within acceptable limits at lower EV penetration rates, significant voltage drop and unbalance occur as EV penetration exceeds 40%, particularly in residential areas with high charging demand. This study offers a framework for integrating spatial analysis and mobility data in power network simulations, providing insights for future EV infrastructure planning.

Pan, Melrose [ORNL] (ORCID:000000031627448X)↗

DASSH-F: Subchannel Based Thermal Analysis

The DASSH thermal analysis code is designed to rapidly allow a reactor design engineer to obtain flow rates requirements that satisfy peak temperature constraints in the domain. The advantage of using DASSH over a hand calculation is that it has a more rigorous treatment of the pin power distribution and coolant heat transfer within an assembly and between assemblies. The advantage of using DASSH over a conventional 3D subchannel code or a computational fluid dynamics code (CFD) is that it can obtain the desired solution in a matter of minutes in serial with minor computer memory needs. The DASSH methodology is virtually identical to SUPERENERGY-2 with additional functionalities taken from follow on work to SUPERENERGY-2 done at ANL in the 1980s. DASSH today is an integral component of the Argonne Fast Reactor analysis suite for reactor design work. DASSH obtains the power distribution from a coupled neutron-gamma heating calculation in GAMSOR (including DIF3D) at each time point of a companion fuel cycle analysis calculation with REBUS. The domain in DASSH assumes a hexagonal grid typical for fast reactors with much of the geometry information taken from the DIF3D model. DASSH assumes the assemblies that are loaded into each grid position are ducted to control the coolant flow. Considerable detail is given on the subchannel formulation of DASSH in this document. Much of the formulation and design of the code builds upon research done by previous authors with little new investigation. Thus the decisions made in developing the subchannel model used in DASSH have their origins over 50 years ago. Much of the heat transfer methodology in DASSH is built upon correlations for both the coolant mixing and heat transfer coefficients for pins and ducts. DASSH is thus not a rigorous treatment of a given problem, but a rapid assessment of the temperature field that has known limitations with respect to an experimental measurement or CFD calculation. The DASSH input and output are detailed along with usage of the software. The DASSH output provides tables of evaluated material properties and key coolant and pin temperature results. DASSH can create Python scripts that generate domain summary pictures. DASSH can also generate assembly temperature maps and VTK output files which allow the DASSH solution to be visualized. As the primary purpose of the DASSH software is to compute the coolant and fuel pin temperature distribution for a given model of a reactor, much of the output focus is giving the user quick summary tables needed to assess the performance of a given orifice flow specification. The present version of DASSH has a crude orifice search capability and an efficient orifice flow search capability. The flow search tries to meet user specified constraints for 1) peak 2-sigma clad midwall temperature, 2) peak coolant temperature, and 3) desired bulk outlet temperature. There are many development shortcomings in DASSH detailed in this document, but this version is functional for modern analysis needs. This document serves as the manual for the Fortran based DASSH software that was developed to replace the Python version of DASSH developed as part of the VTR program.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

DASSH-F: Subchannel Based Thermal Analysis

The DASSH thermal analysis code is designed to rapidly allow a reactor design engineer to obtain flow rates requirements that satisfy peak temperature constraints in the domain. The advantage of using DASSH over a hand calculation is that it has a more rigorous treatment of the pin power distribution and coolant heat transfer within an assembly and between assemblies. The advantage of using DASSH over a conventional 3D subchannel code or a computational fluid dynamics code (CFD) is that it can obtain the desired solution in a matter of minutes in serial with minor computer memory needs. The DASSH methodology for pin lattice models is virtually identical to SUPERENERGY-2 with additional functionalities taken from follow on work to SUPERENERGY-2 done at ANL in the 1980s. DASSH today is an integral component of the Argonne Fast Reactor analysis suite for reactor design work. DASSH obtains the power distribution from a coupled neutron-gamma heating calculation in GAMSOR (including DIF3D) at each time point of a companion fuel cycle analysis calculation with REBUS. The domain in DASSH assumes a hexagonal grid typical for fast reactors with much of the geometry information taken from the DIF3D model. DASSH assumes the assemblies that are loaded into each grid position are ducted to control the coolant flow. The user can alternatively provide their own geometry and power profile instead of inheriting it from DIF3D. Considerable detail is given on the subchannel formulation of DASSH in this document. Much of the formulation and design of the code builds upon research done by previous authors with little new investigation. Thus the decisions made in developing the subchannel model used in DASSH have their origins over 50 years ago. Much of the heat transfer methodology in DASSH is built upon correlations for both the coolant mixing and heat transfer coefficients for pins and ducts. DASSH is thus not a rigorous treatment of a given problem, but a rapid assessment of the temperature field that has known limitations with respect to an experimental measurement or CFD calculation. The DASSH input and output are detailed along with usage of the software. The DASSH output provides tables of evaluated material properties and key coolant and pin temperature results. DASSH can create Python scripts that generate domain summary pictures. DASSH can also generate assembly temperature maps and VTK output files which allow the DASSH solution to be visualized. As the primary purpose of the DASSH software is to compute the coolant and fuel pin temperature distribution for a given model of a reactor, much of the output focus is giving the user quick summary tables needed to assess the performance of a given orifice flow specification. The present version of DASSH has a crude orifice search capability and a sufficient orifice flow search capability. The flow search tries to meet user specified constraints for 1) peak 2-sigma clad temperature, 2) peak coolant temperature, and 3) desired bulk outlet temperature. This document serves as the manual for the Fortran based DASSH software that was developed to replace the Python version of DASSH developed as part of the VTR program.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Artificial Intelligence and Machine Learning Applications in Modern Power Systems

Machine learning (ML) and artificial intelligence (AI) algorithms offer valuable tools for the analysis and interpretation of large datasets. These tools have the capability to uncover insights that may not be readily apparent within these datasets. In recent years, the integration of ML and AI has become increasingly prevalent in various applications within the power system domain. One of the earliest instances of machine learning in power systems can be traced back to demand forecasting, where artificial neural networks were employed for short-term load forecasting. In contemporary power systems, an abundance of high-resolution geospatial and temporal data is generated at various time intervals, ranging from sub-seconds (Phasor Measurement Units or PMUs) to seconds (Supervisory Control and Data Acquisition or SCADA), minutes (Process Information or PI), and extending to days, months, and years. These datasets contain valuable information concerning system reliability and performance. This information holds the potential to offer critical insights into system operations, as well as solutions for predicting and mitigating contingencies to prevent cascading outages. Despite the immense power of machine learning tools, system operators, planners, and utilities often exhibit hesitancy in fully embracing AI-enabled system operations and planning. This cautious approach persists, even as numerous diverse applications of machine learning continue to emerge in the realm of power systems. In this chapter, our focus will delve deep into ML and AI applications tailored for power systems. These applications aim to furnish system operators with enhanced situational awareness and augment their decision-making capabilities, especially during challenging operating conditions. Specific areas of interest encompass root cause analyses of electricity market datasets and the strategic selection of representative samples from vast power system databases for training ML/AI models. Finally, the chapter will conclude with a short discussion on the future of ML/AI in power systems and possible directions that the industry is moving towards.

power system applications, machine learning (ML), ↗

Modeling Distributed Generation in California

In support of analysis for the biennial Integrated Energy Policy Report, the California Energy Commission and the National Renewable Energy Laboratory have partnered to study the growth of distributed energy resources in California. This study involves the use of National Renewable Energy Laboratory's Distributed Generation Market Demand model, available at https://www.nrel.gov/analysis/dgen/, to project statewide adoption of distributed photovoltaics and paired storage. Key outcomes of the collaboration include: • Improved representation of California building stock, load profiles, historical adoption, and tariffs, including the net billing tariff, in the dGen model; • Trained CEC staff members to use and adapt the dGen model for their specific needs; • Developed a methodology for representing emerging consumer segments to potentially adopt distributed energy resources, including low-income, multifamily, and renter-occupied buildings; • Forecasted solar photovoltaic and paired storage growth in California using a common set of modeling parameters. This report describes the multiyear effort, which includes a discussion of: • Methodology and data employed in adapting the Distributed Generation Market Demand model for California to forecast solar photovoltaic and storage statewide through 2040; • Steps taken to modify the base model to forecast solar photovoltaic adoption in emerging market segments such as multifamily or renter-occupied homes or both; • Future enhancements of the model.

14 SOLAR ENERGY↗

Analyzing the Impact of Future Weather Data on Energy Consumption in Weatherization Assistant

This study supports the mission of the U.S. Department of Energy’s Weatherization Assistance Program (WAP), which aims to increase the energy efficiency of dwellings and reduce their total residential expenditures. Specifically, we examine how projected future climate conditions may affect residential building energy performance by integrating future weather data into the National Energy Audit Tool (NEAT). Since WAP evaluates the cost-effectiveness of retrofit measures over lifespans of up to 30 years, accounting for evolving climate conditions is increasingly important. To reflect future household energy demands, this study replaces historically based Typical Meteorological Year (TMY3) weather inputs with Future Typical Meteorological Year (fTMY) datasets derived from global climate model (GCM) projections. A simulation-based framework was established to enable NEAT analysis under future weather conditions. This workflow involves converting EPW-format weather files into JSON inputs compatible with NEAT and generating degree-hour metrics needed for load calculations. The fTMY dataset used in this study was developed by Oak Ridge National Laboratory through downscaling of six GCMs under different emission scenarios and covers the period from 2020 to 2100. In contrast, the TMY3 dataset is based on historical weather data from 1961 to 1990. Simulations were conducted for benchmark single-family prototype buildings across ASHRAE climate zones 1–7, which cover all regions of the U.S. except the subarctic Zone 8 in northern Alaska, evaluating both heating and cooling loads under TMY3 and fTMY conditions. Four foundation types were tested, while heating systems were standardized, as NEAT does not differentiate thermal energy load by HVAC system type in its load calculations. Results show that fTMY weather input consistently yield lower heating loads and higher cooling loads across most locations, aligning with expected climate warming trends. Notably, colder regions such as zones 6A, 6B, and 7 experience marked reductions in heating load, while warmer and transitional zones, such as 2A (Lufkin, TX) and 3C (San Francisco, CA), have substantial increases in cooling loads. Although this study does not directly assess the performance of retrofit measures under future climate conditions, it provides a critical foundation for doing so. By quantifying shifts in baseline (i.e., pre-retrofit case) energy loads between historical and future weather files, the study highlights the importance of integrating climate-responsive data into audit tools. These findings will inform future efforts to evaluate the long-term effectiveness and cost-effectiveness of weatherization measures under changing climate conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of irradiation embrittlement effect on fatigue life of a pressurized-water reactor pressure vessel using the fracture toughness master curve approach

The reactor pressure vessel (RPV) is a critical structural component in pressurized-water reactors, and it is designed to withstand extreme conditions, such as high pressures, elevated temperatures, and prolonged radiation exposure. Ensuring RPV integrity is essential for the safe and reliable long-term operation of nuclear power plants, especially as aging mechanisms such as fatigue and irradiation embrittlement pose increased risks. Fatigue, caused by cyclic thermal and mechanical loading, can lead to crack initiation in localized high-stress regions. Simultaneously, neutron irradiation, particularly in the beltline region, progressively reduces fracture toughness, increasing susceptibility to brittle fracture. These combined effects of fatigue and irradiation embrittlement potentially impact the RPV structural integrity, necessitating fitness-for-service assessments. This study applies the fracture toughness master curve approach to evaluate the impact of irradiation embrittlement on RPV fatigue life. A coupled thermo-mechanical stress analysis identifies critical stress locations under normal service transients, pinpointing regions most vulnerable to fatigue crack initiation and growth. Stress intensity factors for postulated flaws at these locations are calculated, enabling an assessment of fatigue life under irradiated and unirradiated conditions. The results indicate that neutron irradiation embrittlement accelerates the conditions in which a critical crack can form and lead to failure, particularly at lower temperatures. The failure occurs where reduced fracture toughness limits the material’s resistance to crack growth. Axial cracks at nozzle corners are the most life limiting without irradiation, while circumferential cracks demonstrate longer fatigue lives. The findings highlight the importance of incorporating irradiation effects into fatigue life predictions to ensure the long-term structural integrity of RPVs.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamic modelling and control strategy of a temperature-driven metal hydride cooling system for buildings

A temperature-driven coupled metal hydride (MH) based thermal energy storage (TES) system can allow to shave and shift the peak energy demand in buildings. The high energy density and long-term (seasonal) energy storage capability are its major advantages over other energy storage methods. The dynamic nature of the MH operation, however, requires controlled hydrogen transfer between the coupled MHs at a rate needed to meet the building's transient load. While temperature-driven MH systems are studied in the literature, their application in buildings and control are scarcely reported. Here, this paper presents a control-based dynamic modeling of the temperature-driven coupled MH-TES system for building cooling applications. The dynamic model is developed in MATLAB(R) Simulink environment, considering the thermodynamic and kinetic behaviors of the MH systems. Based on a preliminary analysis of a property database of over 337 hydrides, we select around 1600 MH pairs suitable for building cooling applications. Each of these MH pairs is studied for their performance using the dynamic model, and among all, Zr 0.76 Ti 0.24 Ni 1.16 Mn 0.63 V 0.14 Fe 0.18 -Ti 0.85 Zr 0.15 Cr 1.2 Mn 0.8 MH pair showed fast dynamics along with high coefficient of performance (COP) of 0.71. A parametric investigation is performed on this MH pair to understand the effect of operating temperatures. Finally, three proportional-integral (PI) feedback controllers are investigated to regulate the temperature, pressure and mass exchange between the coupled MH pairs. The developed PI controller is sufficiently capable of rejecting the signal noise from the hydrogen flow and internal heat exchange processes with root mean square error of 5.78 W between reference and actual cooling load.

08 HYDROGEN↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Modeling the PV System Level Economic Impact of PV Connector Failure Modes

Photovoltaic (PV) connectors must maintain mechanical integrity for over 25 years while operating under UV exposure, elevated temperature, and mechanical loading. Connector degradation increases with electrical resistance, leading to energy losses, unplanned downtime, and higher operation and maintenance (O&M) costs and in severe cases, safety risks from overhearing or arcing. Connector related failures remain among the most frequent causes of disruption in utility-scale PV (UPV) systems, yet their lifetime economic impacts are poorly quantified. This work presents a techno-economic analysis (TEA) framework that links identified connector failure modes to system level energy losses and lifetime cost impacts using identified resistance measurements and failure rates from 6,2761 PV connectors inspected. Connector failures increase system level O&M costs, raising LCOE by roughly 5%. Downtime driven availability losses dominate economic impact. Resistance-driven I2R and IV-curve losses are secondary, but remain non-negligible. Thermal damage, bend-radius violations, and loose connections drive the majority of LCOE uplift Improving connector reliability through better installation quality, inspection, and design can meaningfully reduce lost energy, O&M costs, and LCOE.

14 SOLAR ENERGY↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY↗

A practical control strategy for demand flexibility with ensured occupant comfort in grid-interactive efficient buildings

This study proposes a practical and simplified demand response (DR) control strategy from the perspective of grid-interactive efficient buildings (GEBs), aiming to secure demand flexibility while ensuring occupant thermal comfort. Focusing on summer on-peak periods, a linear demand response (LDR) strategy that integrates cooling setpoint adjustment and lighting dimming was designed, and its performance was quantitatively evaluated. A case study was conducted using EnergyPlus-based simulations for a U.S. DOE small office prototype building under summer on-peak weather conditions. Compared with a conventional rapid demand response (RDR) strategy, the proposed LDR approach gradually reduced electrical loads while maintaining occupant thermal comfort indices, including predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), within acceptable comfort ranges. Quantitative analysis of demand flexibility using the grid-interactive impact index (GII) and the flexibility strength index (FSI) showed that the LDR strategy provided approximately 12.5% demand flexibility during DR periods and achieved an electricity cost reduction of about 8.8%. In addition, the results of the part-load ratio (PLR)-based cooling system performance analysis showed that, in the on-peak period, the LDR strategy exhibited improved cooling performance compared with the baseline. Overall, this study shows the potential of a practical DR control strategy that can simultaneously achieve occupant comfort and demand flexibility without relying on complex advanced control technologies.

Jung, Dong Eun↗

Optimizing district energy systems by integrating Borehole Thermal Energy Storage Using a Mixed-Integer Linear Programming g-function framework with a Multi-Timescale Rolling Horizon method

Shallow geothermal has gained increasing attention in recent years; however, a reliable framework for its accurate incorporation into large-scale energy system optimization remains lacking. This study proposes a Mixed-Integer Linear Programming (MILP) framework combined with the g-function approach to integrate Borehole Thermal Energy Storage (BTES) technology into energy system optimization. Validation against a Modelica-based reservoir network simulation demonstrates that the proposed framework effectively captures the ground thermal response under varying energy loads and accurately estimates the borefield energy supply. To enhance scalability, a Rolling Horizon with Multi-Timescale (RH-MTS) method is further introduced, reducing computational time by 73 % for the 1-year optimization model with only minor loss of optimality. The framework is demonstrated through the case study of the UC Berkeley campus. Results indicate that BTES is a cost-effective and low-carbon solution: two borefields comprising 382 boreholes can meet 8.0 % and 6.6 % of the total campus heating and cooling demand, respectively, at an average energy rate of 0.70–0.77 USD/kWh and carbon intensity of 0.54 kg-CO2/kWh. Short-term analysis reveals a 35%–65% decline in BTES energy flow after 3–6 months of continuous heating/cooling operation, while long-term simulation shows that annual energy production of BTES can vary by up to 12.0 % after four years before stabilizing. Overall, this study develops a novel optimization framework that couples physics-based g-function method with MILP optimization framework, thereby advancing methodological development for shallow-geothermal integration and providing actionable guidance for BTES deployment in district-energy systems.

Yang, Jiahui↗

Three-Dimensional Grid Visualization for Planning Activities: A Dubai Case Study

National Laboratory of the Rockies (NLR), in collaboration with the Dubai Electricity and Water Authority (DEWA) and Infra-X, has undertaken the Energy Visualization Analysis Project. The aim of this project is to enhance analytical and 3D visualization capabilities for distribution network planning and renewable energy integration. As modern grid continues to evolve with large-scale solar PV deployment and emerging distributed energy resources (DERs), the ability to effectively analyze, visualize, and communicate complex grid behaviors has become increasingly critical. The project focuses on developing empirical use cases based on real distribution feeder data and engineering workflows, ensuring the outcomes are directly aligned with operational environment. Through time-series power flow simulations and nodal hosting capacity analysis, the study quantifies the impacts of high PV penetration on voltage and thermal limits within representative 11 kV feeders. These analyses identify specific nodes and conditions where DER integration challenges arise. Furthermore, a Battery Energy Storage System (BESS) optimization algorithm was applied to determine the optimal size and placement of storage systems that can mitigate network constraints and enhance hosting capacity. The comparative results between base-case and BESS-augmented scenarios clearly demonstrate improvements in network stability and load management efficiency. In parallel, the NLR team developed an immersive 3D visualization framework, enabling interactive exploration of grid simulations using commodity head-mounted display (HMD) systems. This framework transforms conventional 2D simulation data into spatially intuitive visual environments - allowing engineers to analyze feeder conditions, PV hosting potential, and BESS effects in real time. This report represents the first foundational phase in establishing a visualization-driven analytical ecosystem. It provides a methodological foundation for data integration, visualization architecture, and simulation-based decision support, paving the way for large-scale adoption of immersive visualization across DEWA's Smart Grid Initiative, R&D activities, and future network resilience studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital Real-Time Simulation and Power Quality Analysis of a Hydrogen-Generating Nuclear-Renewable Integrated Energy System

This paper investigates the challenges and solutions associated with integrating a hydrogen-generating nuclear-renewable integrated energy system (NR-IES) under a transactive energy framework. The proposed system directs excess nuclear power to hydrogen production during periods of low grid demand while utilizing renewables to maintain grid stability. Using digital real-time simulation (DRTS) in the Typhoon HIL 404 model, the dynamic interactions between nuclear power plants, electrolyzers, and power grids are analyzed to mitigate issues such as harmonic distortion, power quality degradation, and low power factor caused by large non-linear loads. A three-phase power conversion system is modeled using the Typhoon HIL 404 model and includes a generator, a variable load, an electrolyzer, and power filters. Active harmonic filters (AHFs) and hybrid active power filters (HAPFs) are implemented to address harmonic mitigation and reactive power compensation. The results reveal that the HAPF topology effectively balances cost efficiency and performance and significantly reduces active filter current requirements compared to AHF-only systems. During maximum electrolyzer operation at 4 MW, the grid frequency dropped below 59.3 Hz without filtering; however, the implementation of power filters successfully restored the frequency to 59.9 Hz, demonstrating its effectiveness in maintaining grid stability. Future work will focus on integrating a deep reinforcement learning (DRL) framework with real-time simulation and optimizing real-time power dispatch, thus enabling a scalable, efficient NR-IES for sustainable energy markets.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of a Co-Optimized, Smart Hybrid Heat Pump Control

This study examines a residential dual fuel (DF) heating system that integrates heat pump and gas furnace technology with a home’s forced-air distribution ducts. Specifically, it explores a retrofit where an “add-on” heat pump replaces the air conditioning (A/C) system and is combined with the home’s existing furnace and air handler. The research team developed and validated an innovative control scheme for this integrated DF system that selected the more economical heating source (furnace or heat pump) while maintaining comfort in the home. The project’s field study and subsequent modeling analysis show that this control scheme can decrease energy use, cost, and emissions compared to a furnace-only system. As homes in mixed and cold climates transition to more electric space heating, furnace-to-dual fuel system retrofits offer a solution that can alleviate the retrofit costs, energy cost concerns, and peak load impacts of full electrification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Managing Increased Electric Vehicle Shares on Decarbonized Bulk Power Systems

Transportation electrification and power sector decarbonization - the convergence of these two trends present a complex planning problem requiring realistic, region-specific modeling and analysis to ensure that both can happen rapidly and cost effectively. This project, funded through the U.S. Department of Energy's Vehicle Technologies Office, models the evolution of the U.S. bulk power system (through 2050) in response to large-scale EV charging across all on-road vehicle segments. We will assess the opportunity and value of demand-side flexibility (i.e., "smart" charging) for reducing energy costs, increasing renewable generation shares, and managing future EV loads on the bulk power system. Overall, this study aims to provide an improved understanding of least-cost solutions for managing EV load growth on the grid and will make high-resolution EV load data sets publicly available for further analysis.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗