Search NASA⌕ Search

SEARCH · Search NASA

Results for “interconnection engineers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Review of Dynamic Generator Reduction Methods For Transient Stability Studies

Due to the complex interconnected nature of power system, aggregate or reduced system is commonly used by operators and engineers for various power system studies. Transient stability studies need dynamically reduced models to include the dynamic effects of the generating units. Dynamic generator reduction is therefore an important component of power system dynamic reduction. The many different methods for generator reduction in power systems taken from the earliest available literature are discussed. This paper aims to provide an easy reference to researchers interested in exploring dynamic reduction of power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonlinear Optimization and the Modeling of Energy Systems [Slides]

Energy delivery systems are critical for the function of modern society. (Up to) continental-scale engineered systems move energy from source points to consumers. These systems are increasingly complex and interconnected.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Refrigerant charge management in a heat pump water heater

Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, methods of managing refrigerant charge, and methods for heating and cooling a space and heating water. Various embodiments deliver refrigerant gas to a heat exchanger that is not needed for transferring heat, drive liquid refrigerant out of that heat exchanger, isolate that heat exchanger against additional refrigerant flowing into it, and operate the heat pump while the heat exchanger is isolated. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled or adjusted by controlling how much liquid refrigerant is driven from the heat exchanger, by letting refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and segments of refrigerant conduit can be interconnected with various components.

42 ENGINEERING↗

Plug and Play PV Systems for American Homes

The core objectives of the Plug & Play PV Systems Project were to develop a PV system that can be installed on a residential rooftop for less than $1.50/W in 2020, and in less than 10 hours (from point of purchase to commissioning). The Fraunhofer CSE team’s approach to this challenge involved a holistic approach to system design – hardware and software – that make Plug & Play PV systems: • Quick, easy, and safe to install • Easy to demonstrate as code compliant • Permitted, inspected, and interconnected via an electronic process Throughout the three years of work during this Department of Energy SunShot funded project, the team engaged in a substantive way with inspectional services departments and utilities, manufacturers, installers, and distributors. We received iterative feedback on the system design and on ideas for how such systems can be commercialized. This ultimately led us to conceiving of Plug & Play PV Systems as a framework, with a variety of components compatible with the Plug & Play PV approach, including string or microinverters, conventional modules or emerging lightweight modules. The framework enables a broad group of manufacturers to participate in taking Plug & Play PV Systems to market, and increases the market size for such systems. Key aspects of the development effort centered on the system hardware and associated engineering work, the development of a Plug & Play PV Server to enable the electronic permitting, inspection and interconnection process, understanding the details of code compliance and, on occasion, supporting applications for modifications to the code to allow lightweight modules, for example. We have published a number of papers on our testing and assessment of novel technologies (e.g., adhered lightweight modules) and on the electronic architecture.

14 SOLAR ENERGY↗

Rates and Reversibilities in Interconnected Reaction Networks

Mathematical relations prescribing unidirectional forward and reverse rates originally derived based on single-path reaction sequences do not apply to interconnected reaction networks. The presence of branches in reaction networks, leading to alternative stable products, decreases unidirectional rates in reference to those calculated by single-path functional forms, as shown by simulated isotopic exchange rates, but impacts the unidirectional forward and reverse rates equally such that the functional form of effective reversibility remains unchanged. Regardless of stoichiometric numbers and network connectivity, the application of the pseudo-steady-state hypothesis on reactive intermediates in conjunction with consideration of unidirectional rates toward the product of interest and all alternative stable products results in mathematical expressions that accurately reflect simulated isotopic exchange rates. Further analyses based on kinetic resistance, a property akin to electrical resistance, illustrate the manifestation of nodal resistances in addition to the single-path kinetic resistance for interconnected reaction networks. The generalized formalism for assessing rates and reversibilities in interconnected networks derived herein enables us to demonstrate that unidirectional rates cannot be assessed solely from effective reversibilities and net rates of generation of stable species in such networks. Furthermore, isotopic exchange rates, under the condition that each elementary step in the overall reaction sequence forms a unique reactive intermediate that is consumed solely by the subsequent step, can be utilized to determine unidirectional rates and can serve to validate postulated reaction pathways in highly interconnected reaction networks (e.g., CO x hydrogenation).

42 ENGINEERING↗

Data Center Cybersecurity, Supply Chain Risk Management, and Emerging Regulation Cohort Summary: Takeaways and Action Plans

This report summarizes the outcomes of the Data Center Cohort under the Department of Energy’s Technical Assistance for Digital Assurance (TADA) initiative, aimed at enhancing grid resilience through cybersecurity, supply chain risk management (SCRM), and Cyber-Informed Engineering (CIE). The cohort engaged 17 organizations across utilities, data center operators, vendors, and technology providers in three sessions combining presentations, discussions, and exercises. Key topics included AI-driven load behavior, cybersecurity vulnerabilities in UPS/BESS and cooling systems, governance gaps at utility–data center boundaries, and supply chain integrity. Five cross-cutting themes emerged: interconnection architecture vulnerabilities, fragmented governance, AI-driven stability risks, lack of regulatory frameworks, and long-term supply chain concerns. Actionable recommendations were developed, including implementing DMZ segmentation, formalizing vendor access agreements, designing AI workload limits, and advancing standards through NERC and state-level programs. These strategies aim to strengthen resilience, clarify responsibilities, and ensure secure integration of data centers into the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

High Throughput In-Line Coating Metrology Development for Solid Oxide Fuel Cell Manufacturing

Coatings play key roles in solid oxide fuel cell (SOFC) stack durability. For example, diffusion barrier coatings on Cr-containing interconnect and balance of plant (BOP) components protect electrodes from Cr poisoning over the long operational lifetimes (>10,000 hours) of the fuel cell stack. Common defects in coatings, such as cracks, pinholes, and porosity, result in a failure to protect the electrodes, resulting in shorter operational lifetime and thus higher cost. It is very unlikely, even in the best coating process, that all these defects can be mitigated, hence identifying critical defects in parts, and removing defective parts from production before they can damage the stack, becomes paramount. Furthermore, these quality control techniques must be operational in the production/assembly line (in-line), i.e., high throughput and non-destructive, and cost effective. Redox Power Systems, LLC (Redox) together with the National Renewable Energy Laboratory (NREL) developed much needed high throughput, in-line metrology techniques for protective coatings. The overall goal of the project is to lower cost while increasing robustness, reliability, and endurance of SOFC stacks. To accomplish this, we had several objectives, including: to identify key coating and substrate defects that lead to coating failure through the use of detailed characterization methods (e.g., microscopy, XRD, EDS, electrochemistry); to assess capabilities of in-line metrology techniques, e.g., optical profilometry (Redox) and thermography (NREL), to probe these defects, or evidence thereof; demonstrate long-term performance of “defect-free” protective coatings, as identified by in-line metrology, in solid oxide fuel cell (SOFC) stack operation. In the first part of this project, the ability to identify key defects expected to lead to coating and SOFC degradation using in-line metrology tools were evaluated. Coated interconnect samples with controlled defect types and populations were tested under conditions similar to SOFC operation, followed by detailed post-test analysis to reveal the defects responsible for observed degradation. In the second part of the project, the optimal in-line metrology techniques and methodologies were used to map the defect distribution in full-size interconnects with critical defects intentionally allowed to exist in some cases. These interconnects underwent SOFC testing for extended periods (up to ~3,000 hours) followed by post-test analysis to evaluate the effectiveness of in-line metrology techniques in mitigating MCO coating related degradation. Key accomplishments in this project included the following: Demonstrated ASR of < 0.05 ohm-cm 2 at 650 °C for 1,000 hours with low defect (determined by in-line metrology) interconnect samples (average ASR=37 milliohms-cm 2 after over 1,000 hours). Demonstrated that low defect coatings on interconnects (as screened using in-line metrology) have low volatilization of chromium at ~650 °C for 1,000 hours as detected using Cr-getter material (< 5 at% increase above baseline); 1022 hour duration tests under humidified, elevated temperature (750 °C rather than 650 °C) compared a base case against different coating thicknesses. Demonstrated capability to identify initial key defects of interest with in-line metrology techniques using up to 8 cm by 10 cm having coatings with and without intentional defects of interest using thermal imaging and optical profilometry. Correlated key defects identified using metrology techniques with observed coating performance (e.g., ASR and Cr volatility). Conducted several 4 cm by 4 cm cell tests using MCO-interconnects that were pre-screened using some of the metrology techniques developed in the project (e.g., optical profilometry). An analysis of ASR measurements were able to show that defect-free coatings resulted in the anticipated performance in the cell tests.

01 COAL, LIGNITE, AND PEAT↗

An Integrated Hydroclimatic Assessment of Future Reservoir and Hydropower Operations in the U.S.

The engineering of rivers by dams is a formative feature of human-nature systems and the interconnectivity of water, energy, and the climate. Sufficient and broad-based representations of dams in large-scale hydrological models prove essential to mapping their extensive regulation of river flow and biogeochemistry and gauging climate-linked provisions, including freshwater supply and hydropower. We present an integrated modeling framework to investigate future streamflow and hydropower generation in the Contiguous U.S. (1990–2075), leveraging an ensemble of six downscaled and bias-corrected General Circulation Models (GCMs) from the high-end SSP585 scenario of the CMIP6. To achieve this, we develop a reservoir operations and parameterization scheme for 1,384 dams in a high-resolution river network, including simulated hydropower generation for 326 dams. For the GCM ensemble mean, we simulate a widespread increase in regulated streamflow into the late-century (11% annual and 17% in winter for the dam median) with region-specific changes in summer streamflow that feature prominent declines in the Northwest (−7%). Mediation by reservoirs is shown to dampen intra-annual streamflow changes, delivering additional summer releases that partially mitigate declining flows. Total hydropower generation is projected to increase modestly (+3%), with boosted generation in the winter (+9%) and spring (+5%) offsetting declined summer generation (−3.4%), suggesting strong adaptation potential for hydropower in the future energy portfolio. Further analysis reveals that the choice of GCM, particularly in western regions, has significant bearing on projected streamflow and hydropower changes.

13 HYDRO ENERGY↗

Implementing Online Oscillation Monitoring and Forced Oscillation Source Locating at Peak Reliability

This paper introduces a framework of online oscillation monitoring systems and forced oscillation detection & source location tools that Peak Reliability ('PEAK') has implemented for the Reliability Coordinator (RC) function of the Western Interconnection. The framework consists of four main components: (1) Montana Tech's Modal Analysis Software (MAS) engine; (2) Washington State University's Oscillation Monitor System (OMS) software; (3) Forced Oscillation Detection and Source Location Algorithms (FODSL); and (4) PEAK in-house visualization tool and alarming logic built in PI Processbook. The framework has been validated and applied for real system oscillation studies successfully. Implementation experience and lessons learned will be discussed in the paper.

14 SOLAR ENERGY↗

Bottom-Up Copper Filling of Large Scale Through Silicon Vias for MEMS Technology

An electrodeposition process for void-free bottom-up filling of sub-millimeter scale through silicon vias (TSVs) with Cu is detailed. The 600 μm deep and nominally 125 μm diameter metallized vias were filled with Cu in less than 7 hours under potentiostatic control. The electrolyte is made up of 1.25 mol/L CuSO 4 – 0.25 mol/L CH 3 SO 3 H with polyether and halide additions that selectively suppress metal deposition on the free surface and side walls. A brief qualitative discussion of the procedures used to identify and optimize the bottom-up void-free feature filling is presented.

42 ENGINEERING↗

Dynamic Contingency Analysis Tool 2.0 User Manual with Test System Examples

This document introduces Version 2 of the Dynamic Contingency Analysis Tool (DCAT) software package developed by Pacific Northwest National Laboratory and serves as a guide for using this package to conduct cascading failure simulations for the electric power system. The DCAT is an open-platform and publicly available software; it is intended to help develop applications that aim to improve the capabilities of power system planning engineers to assess the impact and likelihood of extreme contingencies and potential cascading events across their systems and interconnections. Outputs from the DCAT will support finding mitigating actions to reduce the risk of cascading outages in technically sound and effective ways. This manual provides detailed instructions on how to use this tool on multicore Windows workstations or servers. In the public version of DCAT, several improvements have been made over the previous version: (1) it was modularized; (2) a graphical user interface (GUI) was developed; (3) a new version of the MPjobs parallel processing module was incorporated; and (4) a batch-processing function was added. The features of the DCAT GUI are described, including some examples of how to use the GUI to perform simulations. A full explanation of the DCAT methodology is available in the Phase 1 report.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Risk-Based Comparison of Carbon Capture Technologies

In this paper, we describe an integrated probabilistic risk assessment methodological framework and a decision-support tool suite for implementing systematic comparisons of competing carbon capture technologies. Culminating from a collaborative effort among national laboratories under the Carbon Capture Simulation Initiative (CCSI), the risk assessment framework and the decision-support tool suite encapsulate three interconnected probabilistic modeling and simulation components. The technology readiness level (TRL) assessment component identifies specific scientific and engineering targets required by each readiness level and applies probabilistic estimation techniques to calculate the likelihood of graded as well as nonlinear advancement in technology maturity. The technical risk assessment component focuses on identifying and quantifying risk contributors, especially stochastic distributions for significant risk contributors, performing scenario-based risk analysis, and integrating with carbon capture process model simulations and optimization. The financial risk component estimates the long-term return on investment based on energy retail pricing, production cost, operating and power replacement cost, plan construction and retrofit expenses, and potential tax relief, expressed probabilistically as the net present value distributions over various forecast horizons.

Engel, David W.↗

Fuel cell system with interconnect

The present invention includes an integrated planar, series connected fuel cell system having electrochemical cells electrically connected via interconnects, wherein the anodes of the electrochemical cells are protected against Ni loss and migration via an engineered porous anode barrier layer.

30 DIRECT ENERGY CONVERSION↗

Fuel cell system with interconnect

The present invention includes an integrated planar, series connected fuel cell system having electrochemical cells electrically connected via interconnects, wherein the anodes of the electrochemical cells are protected against Ni loss and migration via an engineered porous anode barrier layer.

Liu, Zhien↗

On the operational characteristics and economic value of pumped thermal energy storage

Pumped thermal energy storage (PTES) systems use an electrically-driven heat pump to store electricity in the form of thermal energy, and subsequently dispatch the stored thermal energy to generate electricity using a thermodynamic heat engine. Optimal day-ahead operational scheduling and annual value of a PTES system based on Joule-Brayton thermodynamic cycles and two-tank molten salt hot thermal storage is evaluated in this work. Production cost models, which simultaneously optimize commitment and dispatch schedules for an entire set of generators to minimize the cost of satisfying electricity demand, are employed to determine system-optimal operation and day-ahead energy value of the PTES system within each of six hypothetical near-future grid scenarios intended to approximately represent the U.S. Western Interconnection or the Texas Interconnection. Sensitivity to grid scenario (including the contribution of variable renewable energy sources), thermal storage capacity, relative heat pump and heat engine capacities, and startup/shutdown cycling costs are evaluated. PTES energy value and heat engine annual capacity factor increase strongly as the contribution of variable renewable resources increases, heat pump capacity increases relative to heat engine capacity, or PTES cycling costs decrease. Grid scenarios in which the contribution of variable renewable energy is dominated by solar photovoltaics (PV) vs. wind produce inherently different PTES operational patterns. Annual PTES energy value within PV-dominated scenarios increased with storage capacity only up to approximately seven hours of full-load discharge capacity, whereas that within wind-dominated scenarios exhibited a continual increase with storage duration up to at least 16 hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geothermal Power and Interconnection: The Economics of Getting to Market

This report provides a baseline description of the transmission issues affecting geothermal technologies. The report begins with a comprehensive overview of the grid, how it is planned, how it is used, and how it is paid for. The report then overlays onto this 'big picture' three types of geothermal technologies: conventional hydrothermal systems; emerging technologies such as enhanced engineered geothermal systems (EGS) and geopressured geothermal; and geothermal co-production with existing oil and gas wells. Each category of geothermal technology has its own set of interconnection issues, and these are examined separately for each. The report draws conclusions about each technology's market affinities as defined by factors related to transmission and distribution infrastructure. It finishes with an assessment of selected markets with known geothermal potential, identifying those that offer the best prospects for near-term commercial development and for demonstration projects.

03 NATURAL GAS↗