Search NASA⌕ Search

SEARCH · Search NASA

Results for “interface vibrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Electrical Transport Interplay with Charge Density Waves, Magnetization, and Disorder Tuned by 2D van der Waals Interface Modification via Elemental Intercalation and Substitution in ZrTe 3 , 2H-TaS 2 , and Cr 2 Si 2 Te 6 Crystals

Electrical transport in 2D materials exhibits unique behaviors due to reduced dimensionality, broken symmetries, and quantum confinement. It serves as both a sensitive probe for the emergence of coherent electronic phases and a tool to actively manipulate many-body correlated states. Exploring their interplay and interdependence is crucial but remains underexplored. This review integratively cross-examines the atomic and electronic structures and transport properties of van der Waals-layered crystals ZrTe 3 , 2H-TaS 2 , and Cr 2 Si 2 Te 6 , providing a comprehensive understanding and uncovering new discoveries and insights. A common observation from these crystals is that modifying the atomic and electronic interface structures of 2D van der Waals interfaces using heteroatoms significantly influences the emergence and stability of coherent phases, as well as phase-sensitive transport responses. In ZrTe 3 , substitution and intercalation with Se, Hf, Cu, or Ni at the 2D vdW interface alter phonon–electron coupling, valence states, and the quasi-1D interface Fermi band, affecting the onset of CDW and SC, manifested as resistance upturns and zero-resistance states. We conclude here that these phenomena originate from dopant-induced variations in the lattice spacing of the quasi-1D Te chains of the 2D vdW interface, and propose an unconventional superconducting mechanism driven by valence fluctuations at the van Hove singularity, arising from quasi-1D lattice vibrations. Short-range in-plane electronic heterostructures at the vdW interface of Cr 2 Si 2 Te 6 result in a narrowed band gap. The sharp increase in in-plane resistance is found to be linked to the emergence and development of out-of-plane ferromagnetism. The insertion of 2D magnetic layers such as Mn, Fe, and Co into the vdW gap of 2H-TaS 2 induces anisotropic magnetism and associated transport responses to magnetic transitions. Overall, 2D vdW interface modification offers control over collective electronic behavior, transport properties, and their interplays, advancing fundamental science and nanoelectronic devices.

2D van der Waals interfaces↗

Seminar on Understanding Digital Control and Analysis in Vibration Test Systems, part 2

A number of techniques for dealing with important technical aspects of the random vibration control problem are described. These include the generation of pseudo-random and true random noise, the control spectrum estimation problem, the accuracy/speed tradeoff, and control correction strategies. System hardware, the operator-system interface, safety features, and operational capabilities of sophisticated digital random vibration control systems are also discussed.

Source record↗

Hydroelastic vibration analysis of partially liquid-filled shells using a series representation of the liquid

A series representation of the oscillatory behavior of incompressible nonviscous liquids contained in partially filled elastic tanks is presented. Each term is selected on the basis of hydroelastic vibrations in circular cylindrical tanks. Using a complementary energy principle, the superposition of terms is made to approximately satisfy the liquid-tank interface compatibility. This analysis is applied to the gravity sloshing and hydroelastic vibrations of liquids in hemispherical tanks and in a typical elastic aerospace propellant tank. With only a few series terms retained, the results correlate very well with existing analytical results, NASTRAN-generated analytical results, and experimental test results. Hence, although each term is based on a cylindrical tank geometry, the superposition can be successfully applied to noncylindrical tanks.

Housner, J. M.↗

Test of the Hipparcos payload in the Liege vacuum facility focal

The Liege thermal vacuum optical bench (FOCAL) was used to control the mechanical stability of the structure of the European Space Agency's HIPPARCOS astrometry payload. The payload is designed to measure angles of .001 arcsec between stars during 2.5 years and this accuracy can only be reached with the extreme stability of the device. The structure of the payload is made of carbon fiber; it is thermally stabilized with an accuracy of .01 degrees C. During the test, the payload is enclosed in a shell made of shrouds having a geometry close to the shading structure of the spacecraft. The shroud temperatures are defined by the conditions in orbit, e.g., the spacecraft is spinning in front of the Sun with a period of two hours and the temperature of the shrouds is cycled around the payload with a 2 hour period. In order to avoid disturbances by vibrations, the payload is put on an adapter interfaced with the optical bench and the seismic block; the shrouds are supported by a carrier with no direct interface with the table. This method avoids perturbances brought about by the cooling fluid of the shrouds.

Jamar, C.↗

Healthwatch-2 System Overview

Healthwatch-2 (HW-2) is a research tool designed to facilitate the development and testing of in-flight health monitoring algorithms. HW-2 software is written in C/C++ and executes on an x86-based computer running the Linux operating system. The executive module has interfaces for collecting various signal data, such as vibration, torque, tachometer, and GPS. It is designed to perform in-flight time or frequency averaging based on specifications defined in a user-supplied configuration file. Averaged data are then passed to a user-supplied algorithm written as a Matlab function. This allows researchers a convenient method for testing in-flight algorithms. In addition to its in-flight capabilities, HW-2 software is also capable of reading archived flight data and processing it as if collected in-flight. This allows algorithms to be developed and tested in the laboratory before being flown. Currently HW-2 has passed its checkout phase and is collecting data on a Bell OH-58C helicopter operated by the U.S. Army at NASA Ames Research Center.

Barszcz, Eric↗

MEMS Device Being Developed for Active Cooling and Temperature Control

High-capacity cooling options remain limited for many small-scale applications such as microelectronic components, miniature sensors, and microsystems. A microelectromechanical system (MEMS) is currently under development at the NASA Glenn Research Center to meet this need. It uses a thermodynamic cycle to provide cooling or heating directly to a thermally loaded surface. The device can be used strictly in the cooling mode, or it can be switched between cooling and heating modes in milliseconds for precise temperature control. Fabrication and assembly are accomplished by wet etching and wafer bonding techniques routinely used in the semiconductor processing industry. Benefits of the MEMS cooler include scalability to fractions of a millimeter, modularity for increased capacity and staging to low temperatures, simple interfaces and limited failure modes, and minimal induced vibration.

Moran, Matthew E.↗

Defects vibrations engineering for enhancing interfacial thermal transport in polymer composites

To push upper boundaries of thermal conductivity in polymer composites, understanding of thermal transport mechanisms is crucial. Despite extensive simulations, systematic experimental investigation on thermal transport in polymer composites is limited. To better understand thermal transport processes, we design polymer composites with perfect fillers (graphite) and defective fillers (graphite oxide), using polyvinyl alcohol (PVA) as a matrix model. Measured thermal conductivities of ~1.38 ± 0.22 W m -1 K -1 in PVA/defective filler composites is higher than those of ~0.86 ± 0.21 W m -1 K -1 in PVA/perfect filler composites, while measured thermal conductivities in defective fillers are lower than those of perfect fillers. We identify how thermal transport occurs across heterogeneous interfaces. Thermal transport measurements, neutron scattering, quantum mechanical modeling, and molecular dynamics simulations reveal that vibrational coupling between PVA and defective fillers at PVA/filler interfaces enhances thermal conductivity, suggesting that defects in polymer composites improve thermal transport by promoting this vibrational coupling.

42 ENGINEERING↗

Development of a new method in force limited vibration testing

The force limited vibration test approaches discussed in NASA-HDBK-7004C were developed to reduce overtesting associated with base shake vibration tests of aerospace hardware. This handbook outlines several different methods of specifying force limiting specifications. The basis for deriving force limiting specifications is related to the differences between mechanical impedances of typical aerospace hardware interfacing the mounting structures in flight configurations and the large impedances inherent in shaker vibration testing. Among these approaches, the semi-empirical method is presently the most widely used method to derive the force limiting specifications. This method is developed based on the assumption that the hardware interface responses are coherently excited. The inclusion of the incoherent excitation of the aerospace structures at mounting interfaces provides the basis for developing a more realistic force limiting specification that may be used to qualify flight hardware for launch environments using shaker testing. In this paper the semi-empirical method for defining force limiting specifications discussed in NASA handbook are reviewed using data recently obtained from a series of acoustic and vibration tests. A mathematical formation of a new force limiting approach based on considering the incoherent excitation of the hardware at their mounting interfaces is developed. Results from the analysis, which are correlated to the data obtained from a series of well instrumented acoustic and vibration tests, are discussed. The new approach provides much more realistic force limits that may further remove conservatism inherent in shaker vibration testing not accounted for by methods discussed in the NASA handbook.

Kolaini, Ali R.↗

Evaluation of a pulse control law for flexible spacecraft

The following analytical and experimental studies were conducted: (1) A simple algorithm was developed to suppress the structural vibrations of 3-dimensional distributed parameter systems, subjected to interface motion and/or directly applied forces. The algorithm is designed to cope with structural oscillations superposed on top of rigid-body motion: a situation identical to that encountered by the SCOLE components. A significant feature of the method is that only local measurements of the structural displacements and velocities relative to the moving frame of reference are needed. (2) A numerical simulation study was conducted on a simple linear finite element model of a cantilevered plate which was subjected to test excitations consisting of impulsive base motion and of nonstationary wide-band random excitation applied at its root. In each situation, the aim was to suppress the vibrations of the plate relative to the moving base. (3) A small mechanical model resembling an aircraft wing was designed and fabricated to investigate the control algorithm under realistic laboratory conditions.

Source record↗

Vibration Fixture Design and Testing for Rigid - Y Cable Mount on MMRTG F4

INL is responsible for the fueling and testing of Radioisotope Thermoelectric Generators for NASA space missions. For the upcoming NASA mission "DRAGONFLY," INL is tasked with fueling and testing the Multi-Mission Radioisotope Thermoelectric Generator F4 (MMRTG F4). This involves conducting various tests, such as vibration testing and mass properties testing. For these tests, an interface is required between the MMRTG and the testing equipment, provided by cables mounted on a legacy bracket. Due to design changes in the cooling lines, a new cable – the Rigid Y cable – is to be used. The test described in this poster was to verify if the Rigid Y cable would survive the vibration tests. The results will determine the procedure for conducting the vibration tests on the MMRTG F4.

42 - ENGINEERING↗

Stabilization of Hydroxide Ions at the Interface of a Hydrophobic Monolayer on Water via Reduced Proton Transfer

We report a joint study using surface-specific sum-frequency vibrational spectroscopy and ab initio molecular dynamics simulations, respectively, on a pristine hydrophobic (sub)monolayer hexane-water interface, namely, the hexane/water interface with varied vapor pressures of hexane and different pHs in water. We show clear evidence that hexane on water revises the interfacial water structure in a way that stabilizes the hypercoordinated solvation structure and slows down the migration of hydroxide ion (OH – ) relative to that in bulk water. Furthermore, this mechanism effectively attracts the OH – to the water-hydrophobic interface with respect to its counterion. The result illustrates the striking difference of proton transfer of hydrated OH – at the interface and in the bulk, which is responsible for the intrinsic charging effect at the hydrophobic interface.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dynamic substructuring by the boundary flexibility vector method of component mode synthesis

Component mode synthesis (CMS) is a method of dynamic analysis, for structures having a large number of degrees of freedom (DOF). These structures often required lengthy computer CPU time and large computer memory resources, if solved directly by the finite-element method (FEM). In CMS, the structure is divided into independent components in which the DOF are defined by a set of generalized coordinates defined by displacement shapes. The number of the generalized coordinates are much less than the original number of physical DOF, in the component. The displacement shapes are used to transform the component property matrices and any applied external loads, to a reduced system of coordinates. Reduced system property matrices are assembled, and any type of dynamic analysis is carried out in the reduced coordinate system. Any obtained results are back transformed to the original component coordinate systems. In all conventional methods of CMS, the mode shapes used for components are dynamic mode shapes, supplemented by static deflected shapes. Historically, all the dynamic mode shapes used in conventional CMS are the natural modes (eigenvectors) of components. A new method of CMS, namely the boundary flexibility vector method of CMS, is presented. The method provides for the incorporation of a set of static Ritz vectors, referred to as boundary flexibility vectors, as a replacement and/or supplement to conventional eigenvectors, as displacement shapes for components. The generation of these vectors does not require the solution of a costly eigenvalue problem, as in the case of natural modes in conventional CMS, and hence a substantial saving in CPU time can be achieved. The boundary flexibility vectors are generated from flexibility (or stiffness) properties of components. The formulation presented is for both free and fixed-interface components, and for both the free and forced vibration problems. Free and forced vibration numerical examples are presented to verify the accuracy of the method and the saving in CPU time. Compared to conventional methods of CMS, the results indicate that by using the new method, more accurate results can be obtained with a substantial saving in CPU time.

Abdallah, Ayman Ahmed↗

Apparatus and amendment of wind turbine blade impact detection and analysis

A multisensory system provides both temporal and spatial coverage capacities for auto-detection of bird collision events. The system includes an apparatus having a first circuitry to capture and store a series of images or video of a blade of a wind turbine; and a memory to store the images from the first circuitry. The apparatus also has one or more sensors to continuously sense vibration of the blade or for acoustic recordings; and a second circuitry to analyze the sensor data stream and/or the series of images or video to identify a cause of the vibration and to trigger the camera(s). A communication interface transmits data from the second circuitry to another device, wherein the second circuitry applies artificial intelligence or machine learning to control sensitivity of the one or more sensors.

Johnston, Matthew↗

Squeezing Out Interfacial Solvation: The Role of Hydrogen-Bonding in the Structural and Orientational Freedom of Molecular Self-Assembly

We report bioinspired membrane molecules with improved physical properties and enhanced stability can serve as functional models for conventional lipid or amphiphilic species. Importantly, these molecules can also provide new insights into emergent phenomena that manifest during self-assembly at interfaces. Here, we elucidate the structural response and mechanistic steps underlying the self-assembly of the amphiphilic, charged oligodimethylsiloxane imidazolium cation (ODMS-MIM+) at the air–aqueous interface using Langmuir trough methods with coincident surface-specific vibrational sum-frequency generation (SFG) spectroscopy. We find evidence for a new compression-induced desolvation step that precedes commonly known disordered-to-ordered phase transitions to form nanoscopic assemblies. The experimental data was supported by atomistic molecular dynamics (MD) simulations to provide a detailed mechanistic picture underlying the assembly and the role of water in these phase transitions. The sensitivity of the hydrophobic ODMS tail conformations to compression-owing to distinct water–ODMS interactions and tail–tail solvation properties-offers new strategies for the design of interfaces that can be further used to develop soft-matter electronics and low-dimensional materials using physical and chemical controls.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-Dimensional Vibration Isolator for Suppressing High-Frequency Responses for Sage III Contamination Monitoring Package (CMP)

The Stratospheric Aerosol and Gas Experiment (SAGE) III - International Space Station (ISS) instrument will be used to study ozone, providing global, long-term measurements of key components of the Earth's atmosphere for the continued health of Earth and its inhabitants. SAGE III is launched into orbit in an inverted configuration on SpaceX;s Falcon 9 launch vehicle. As one of its four supporting elements, a Contamination Monitoring Package (CMP) mounted to the top panel of the Interface Adapter Module (IAM) box experiences high-frequency response due to structural coupling between the two structures during the SpaceX launch. These vibrations, which were initially observed in the IAM Engineering Development Unit (EDU) test and later verified through finite element analysis (FEA) for the SpaceX launch loads, may damage the internal electronic cards and the Thermoelectric Quartz Crystal Microbalance (TQCM) sensors mounted on the CMP. Three-dimensional (3D) vibration isolators were required to be inserted between the CMP and IAM interface in order to attenuate the high frequency vibrations without resulting in any major changes to the existing system. Wire rope isolators were proposed as the isolation system between the CMP and IAM due to the low impact to design. Most 3D isolation systems are designed for compression and roll, therefore little dynamic data was available for using wire rope isolators in an inverted or tension configuration. From the isolator FEA and test results, it is shown that by using the 3D wire rope isolators, the CMP high-frequency responses have been suppressed by several orders of magnitude over a wide excitation frequency range. Consequently, the TQCM sensor responses are well below their qualification environments. It is indicated that these high-frequency responses due to the typical instrument structural coupling can be significantly suppressed by a vibration passive control using the 3D vibration isolator. Thermal and contamination issues were also examined during the isolator selection period for meeting the SAGE III-ISS instrument requirements.

Li, Y.↗

Nanoparticle-Induced Disorder at Complex Liquid–Liquid Interfaces: Effects of Curvature and Compositional Synergy on Functional Surfaces

The self-assembly of surfactant monolayers at interfaces plays a sweeping role in tasks ranging from household cleaning to the regulation of the respiratory system. The synergy between different nanoscale species at an interface can yield assemblies with exceptional properties, which enhance or modulate their function. However, understanding the mechanisms underlying coassembly, as well as the effects of intermolecular interactions at an interface, remains an emerging and challenging field of study. Herein, we study the interactions of gold nanoparticles striped with hydrophobic and hydrophilic ligands with phospholipids at a liquid–liquid interface and the resulting surface-bound complexes. We show that these nanoparticles, which are themselves minimally surface active, have a direct concentration-dependent effect on the rapid reduction of tension for assembling phospholipids at the interface, implying molecular coassembly. Through the use of sum frequency generation vibrational spectroscopy, we reveal that nanoparticles impart structural disorder to the lipid molecular layers, which is related to the increased volumes that amphiphiles can sample at the curved surface of a particle. The results strongly suggest that hydrophobic and electrostatic attractions imparted by nanoparticle functionalization drive lipid–nanoparticle complex assembly at the interface, which synergistically aids lipid adsorption even when lipids and nanoparticles approach the interface from opposite phases. The use of tensiometric and spectroscopic analyses reveals a physical picture of the system at the nanoscale, allowing for a quantitative analysis of the intermolecular behavior that can be extended to other systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Studies Of Residual Flexibility And Vibration Testing

Collection of reports presents theoretical and experimental studies in which concept of residual flexibility applied to modal vibration testing and verification of mathematical models of vibrations of flexible structure constrained by another structure. "Residual flexibility" denotes that part of interface flexibility due to mode shapes out of frequency range of test. Studies directed toward assessing residual-flexibility approach as substitute for fixed-base vibrational testing of payloads installed in spacecraft.

Admire, John R.↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

Kenneth J Pederson↗