Search NASASearch

SEARCH · Search NASA

Results for “interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Phase conjugate Twyman-Green interferometer for testing conicoidal surfaces

An application of a phase conjugate Twyman-Green interferometer for testing a parabolic mirror is demonstrated. The interferometer is free from aberrations due to the self-focusing property of the phase conjugate mirror in one arm of the interferometer. It does not require a precision spherical mirror in the reference arm.

Shukla, R. P.

Lunar optical interferometer

Various design configurations of a lunar optical interferometer are examined to determine the interaction of science objectives and the architecture of an instrument that will have 10 microarcsec imaging resolution and 0.1 microarcsec astrometric accuracy. The imaging of the central energy source of AGNs, the discovery of earth-like planets around nearby stars, and the measurement of the proper motion of extragalactic objects to determine the isotropy of the Hubble expansion are some of the observations possible with a lunar interferometer. This interferometer with kilometric baselines and large collecting area will be able to make astronomical observations with angular resolution and sensitivity many orders of magnitude beyond orbital based or earth based instruments.

Shao, M.

Sub-hertz relative frequency stabilization of two-diode laser-pumped Nd:YAG lasers locked to a Fabry-Perot interferometer

Two-diode laser-pumped Nd:YAG lasers have been frequency stabilized to a commercial 6.327-GHz free spectral range Fabry-Perot interferometer yielding a best-case beatnote linewidth of 330 mHz. In addition, a Fabry-Perot interferometer with a free spectral range of 680 MHz, a linewidth of 25 kHz, and a finesse of 27,500 has been built, and when substituted in place of the commercial interferometer produced a robust and easily repeatable beatnote linewidth of 700 MHz.

Day, Timothy

The Mount Wilson optical interferometer: The first automated instrument and the prospects for lunar interferometry

Before contemplating an optical interferometer on the Moon one must first review the accomplishments achieved by this technology in scientific applications for astronomy. This will be done by presenting the technical status of optical interferometry as achieved by the Mount Wilson Optical Interferometer. The further developments needed for a future lunar-based interferometer are discussed.

Johnston, Ken J.

Recent astronomical results from the infrared spatial interferometer and their implications for LOUISA

A new heterodyne interferometer for the atmospheric window from 9 to 12 microns was developed during the past five years. This instrument, called the Infrared Spatial Interferometer (ISI), was designed to use earth rotation aperture synthesis techniques developed in radio interferometry. It was moved to Mt. Wilson, California, in January 1988 and first fringes were obtained in June of that year. Systematic observations of some of the brighter late-type stars began shortly after the first fringes were obtained. We describe the basic principles and design of the ISI and give an overview of some of the initial results obtained from these observations. The implications of our work to the proposed Lunar Optical/UV/IR Synthesis Array (LOUISA) are discussed. We also analyze the conditions for the maximum signal-to-noise ratio of such an interferometer as a function of wavelength. The optimum wavelength is found to depend on the assumed scaling relation between telescope area and wavelength.

Danchi, William C.

Explosive component acceptance tester using laser interferometer technology

Acceptance testing of explosive components requires a reliable and simple to use testing method that can discern less than optimal performance. For hot-wire detonators, traditional techniques use dent blocks or photographic diagnostic methods. More complicated approaches are avoided because of their inherent problems with setup and maintenance. A recently developed tester is based on using a laser interferometer to measure the velocity of flying plates accelerated by explosively actuated detonators. Unlike ordinary interferometers that monitor displacement of the test article, this device measures velocity directly and is commonly used with non-spectral surfaces. Most often referred to as the VISAR technique (Velocity Interferometer System for Any Reflecting Surface), it has become the most widely-accepted choice for accurate measurement of velocity in the range greater than 1 mm/micro-s. Traditional VISAR devices require extensive setup and adjustment and therefore are unacceptable in a production-testing environment. This paper describes a new VISAR approach which requires virtually no adjustments, yet provides data with accuracy comparable to the more complicated systems. The device, termed the Fixed-Cavity VISAR, is currently being developed to serve as a product verification tool for hot-wire detonators and slappers. An extensive data acquisition and analysis computer code was also created to automate the manipulation of raw data into final results.

Wickstrom, Richard D.

Fourier Transform Fabry-Perot Interferometer

We are developing a compact, rugged, high-resolution remote sensing instrument with wide spectral scanning capabilities. This relatively new type of instrument, which we have chosen to call the Fourier-Transform Fabry-Perot Interferometer (FT-FPI), is accomplished by mechanically scanning the etalon plates of a Fabry-Perot interferometer (FPI) through a large optical distance while examining the concomitant signal with a Fourier-transform analysis technique similar to that employed by the Michelson interferometer. The FT-FPI will be used initially as a ground-based instrument to study near-infrared atmospheric absorption lines of trace gases using the techniques of solar absorption spectroscopy. Future plans include modifications to allow for measurements of trace gases in the stratosphere using spectral lines at terahertz frequencies.

Snell, Hilary E.

System identification of the JPL micro-precision interferometer truss - Test-analysis reconciliation

The JPL Micro-Precision Interferometer (MPI) is a testbed for studying the use of control-structure interaction technology in the design of space-based interferometers. A layered control architecture will be employed to regulate the interferometer optical system to tolerances in the nanometer range. An important aspect of designing and implementing the control schemes for such a system is the need for high fidelity, test-verified analytical structural models. This paper focuses on one aspect of the effort to produce such a model for the MPI structure, test-analysis model reconciliation. Pretest analysis, modal testing, and model refinement results are summarized for a series of tests at both the component and full system levels.

Red-Horse, J. R.

V-groove diffraction grating for use in an FUV spatial heterodyne interferometer

A need has arisen for efficient, blazed, symmetric gratings for use as beam splitters in far and extreme ultraviolet interferometers. In particular, the development of an all-reflection, far ultraviolet spatial heterodyne interferometer can benefit tremendously from such a grating. To fulfill this need, we have manufactured a mechanically ruled grating with a V-groove profile blazed for H Lyman-alpha at 1216 A. We present the grating performance at Lyman-alpha in the context of its application to the spatial heterodyne interferometer.

Cotton, Daniel M.

Orbiting stellar interferometer for astrometry and imaging

The orbiting stellar interferometer (OSI) is a concept for a first-generation space interferometer with astrometric and imaging goals. The OSI is a triple Michelson interferometer with articulating siderostats and optical delay lines. Two point designs for the instrument are described. The 18-m design uses an 18-m maximum baseline and aperture diameters of 40 cm; the targeted astrometric performance is a wide-field accuracy of 10 microarsec for 16-mag objects in 100 s of integration time and for 20-mag objects in 1 h. The instrument would also be capable of synthesis imaging with a resolution of 5 marcsec, which corresponds to the diffraction limit of the 18-m base line. The design uses a deployed structure, which would fold to fit into an Atlas IIAS shroud, for insertion into a 900-km sun-synchronous orbit. In addition to the 18-m point design, a 7-m point design that uses a shorter base line in order to simplify deployment is also discussed. OSI's high performance is made possible by utilizing laser metrology and controlled-optics technology.

Colavita, M. M.

WINDII, the wind imaging interferometer on the Upper Atmosphere Research Satellite

The WIND imaging interferometer (WINDII) was launched on the Upper Atmosphere Research Satellite (UARS) on September 12, 1991. This joint project, sponsored by the Canadian Space Agency and the French Centre National d'Etudes Spatiales, in collaboration with NASA, has the responsibility of measuring the global wind pattern at the top of the altitude range covered by UARS. WINDII measures wind, temperature, and emission rate over the altitude range 80 to 300 km by using the visible region airglow emission from these altitudes as a target and employing optical Doppler interferometry to measure the small wavelength shifts of the narrow atomic and molecular airglow emission lines induced by the bulk velocity of the atmosphere carrying the emitting species. The instrument used is an all-glass field-widened achromatically and thermally compensated phase-stepping Michelson interferometer, along with a bare CCD detector that images the airglow limb through the interferometer. A sequence of phase-stepped images is processed to derive the wind velocity for two orthogonal view directions, yielding the vector horizontal wind. The process of data analysis, including the inversion of apparent quantities to vertical profiles, is described.

Shepherd, G. G.

A phase-stepped point diffraction interferometer using liquid crystals

A new instrument, the liquid crystal point diffraction interferometer (LCPDI), has been developed for the measurement of phase objects. This instrument maintains the compact, robust design of Linnik's point diffraction interferometer (PDI) and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wavefronts with high data density and with automated data reduction. The design of the LCPDI is briefly discussed. An algorithm is presented for eliminating phase measurement error caused by object beam intensity variation from frame-to-frame. The LCPDI is demonstrated by measuring the temperature distribution across a heated chamber filled with silicone oil. The measured results are compared to independently measured results and show excellent agreement with them. It is expected that this instrument will have application in the fluid sciences as a diagnostic tool, particularly in space based applications where autonomy, robustness, and compactness are desirable qualities. It should also be useful for the testing of optical elements, provided a master is available for comparison.

Mercer, Carolyn R.

The Michelson Stellar Interferometer Error Budget for Triple Triple-Satellite Configuration

This report presents the results of a study of the instrumentation tolerances for a conventional style Michelson stellar interferometer (MSI). The method used to determine the tolerances was to determine the change, due to the instrument errors, in the measured fringe visibility and phase relative to the ideal values. The ideal values are those values of fringe visibility and phase that would be measured by a perfect MSI and are attributable solely to the object being detected. Once the functional relationship for changes in visibility and phase as a function of various instrument errors is understood it is then possible to set limits on the instrument errors in order to ensure that the measured visibility and phase are different from the ideal values by no more than some specified amount. This was done as part of this study. The limits we obtained are based on a visibility error of no more than 1% and a phase error of no more than 0.063 radians (this comes from 1% of 2(pi) radians). The choice of these 1% limits is supported in the literture. The approach employed in the study involved the use of ASAP (Advanced System Analysis Program) software provided by Breault Research Organization, Inc., in conjunction with parallel analytical calculations. The interferometer accepts object radiation into two separate arms each consisting of an outer mirror, an inner mirror, a delay line (made up of two moveable mirrors and two static mirrors), and a 10:1 afocal reduction telescope. The radiation coming out of both arms is incident on a slit plane which is opaque with two openings (slits). One of the two slits is centered directly under one of the two arms of the interferometer and the other slit is centered directly under the other arm. The slit plane is followed immediately by an ideal combining lens which images the radiation in the fringe plane (also referred to subsequently as the detector plane).

Marathay, Arvind S.

Global tropospheric and total ozone monitoring with a Double-Etalon Fabry-Perot interferometer

Knowledge of the global scale distribution of atmospheric ozone and its temporal variability can be achieved using a satellite-based nadir-viewing device making high spectral resolution measurements with high signal-to-noise ratios. This would enable observation in the pressure-broadened wings of strong O3 lines while minimizing the impact of undesirable signal contributions associated with, for example, the terrestrial surface and interfering species. The Fabry-Perot interferometer (FPI) provides high spectral resolution and high throughput capabilities that are essential for this measurement task. The periodic nature of the Fabry-Perot instrument function can be advantageous when observation of periodic spectra is desired. However, for most applications, additional optical elements are necessary to reduce the effect of unwanted passbands. This is frequently accomplished using additional Fabry-Perot etalons in a series configuration in conjunction with a bandpass filter. This paper discusses a Fabry-Perot interferometer conceptual instrument design to achieve tropospheric and total ozone monitoring capability from a satellite-based nadir-viewing geometry. The design involves a double-etalon fixed-gap series configuration FPI along with an ultra-narrow bandpass filter to achieve single-order operation with an overall spectral resolution of approximately .068 cm(exp -1). The impact of inter-etalon reflections has been reduced to acceptable levels by placement of a slightly attenuating medium in between the etalons. A passive device is selected for low power consumption, and continuous day/night coverage, independent of solar zenith angle, is enabled by observing within the strong 9.6 micron ozone infrared band. The IR-FPI detection will be performed through implementation of the new Circle to Line Interferometer Optical (CLIO) system, developed by researchers at the Space Physics Research Laboratory (SPRL) of the University of Michigan, to accomplish focal plane fringe detection; the CLIO system converts the circular interferometric fringes into a linear pattern which then can be detected by conventional linear array detectors. A multiplex signal advantage is achievable as all necessary frequencies can be measured simultaneously using a multichannel configuration. Through proper selection of channel spectral regions, the FPI optimized for tropospheric O3 measurements can simultaneously observe a stratospheric component and thus the total O3 column abundance.

Larar, Allen M.

Portable, solid state, fiber optic coupled Doppler interferometer system for detonation and shock diagnostics

VISAR (Velocity Interferometer System for Any Reflector) is a specialized Doppler interferometer system that is gaining world-wide acceptance as the standard for shock phenomena analysis. The VISAR's large power and cooling requirements, and the sensitive and complex nature of the interferometer cavity have restricted the traditional system to the laboratory. This paper describes the new portable VISAR, its peripheral sensors, and the role it played in optically measuring ground shock of and underground nuclear detonation. The Solid State VISAR uses a prototype diode pumped Nd:YAG laser and solid state detectors that provide a suitcase-size system with low power requirements. A special window and sensors were developed for fiber optic coupling (1 kilometer long) to the VISAR. The system has proven itself as a reliable, easy to use instrument that is capable of field test use and rapid data reduction using only a notebook personal computer (PC).

Fleming, K. J.

Performance Assessment of the Digital Array Scanned Interferometer (DASI) Concept

Interferometers are known to have higher throughput than grating spectrometers for the same resolvance. The digital array scanned interferometer (DASI) has been proposed as an instrument that can capitalize on the superior throughput of the interferometer and, simultaneously, be adapted to imaging. The DASI is not the first implementation of the dual purpose concept, but it is one that has made several claims of major performance superiority, and it has been developed into a complete instrument. This paper reviews the DASI concept, summarizes its claims, and gives an assessment of how well the claims are justified. It is shown that the claims of signal-to-noise ratio superiority and operational simplicity are realized only modestly, if at all.

Katzberg, Stephen J.

Integrated Optical Interferometers with Micromachined Diaphragms for Pressure Sensing

Optical pressure sensors have been fabricated which use an integrated optical channel waveguide that is part of an interferometer to measure the pressure-induced strain in a micromachined silicon diaphragm. A silicon substrate is etched from the back of the wafer leaving a rectangular diaphragm. On the opposite side of the wafer, ring resonator and Mach-Zehnder interferometers are formed with optical channel waveguides made from a low pressure chemical vapor deposited film of silicon oxynitride. The interferometer's phase is altered by pressure-induced stress in a channel segment positioned over the long edge of the diaphragm. The phase change in the ring resonator is monitored using a link-insensitive swept frequency laser diode, while in the Mach-Zehnder it is determined using a broad band super luminescent diode with subsequent wavelength separation. The ring resonator was found to be highly temperature sensitive, while the Mach-Zehnder, which had a smaller optical path length difference, was proportionally less so. The quasi-TM mode was more sensitive to pressure, in accord with calculations. Waveguide and sensor theory, sensitivity calculations, a fabrication sequence, and experimental results are presented.

DeBrabander, Gregory N.

Fabrication of Fabry-Perot Interferometer Sensors and Characterization of their Performances for Aircraft Inspection

This work provides the information for fabricating Fabry-Perot Interferometer sensors and their performances. The Fabry-Perot Interferometer sensors developed here will be used for the detection of flaws in aircraft structures. The sequel also contains discussion of the experimental setups for the Ultrasonic technique and the Fabry-Perot Interferometer.

Pendergrass, LeRuth Q.