Data-Driven Power Flow Estimation with Inverter Interfaced Energy Storage Using Dynamic Injection Shift Factor
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Time series data set containing labeled clipping periods.
As conventional direct connections of synchronous generators are being phased out, inverter-based resources (IBRs) with grid support functions are increasingly being integrated into power systems. This transition requires the development of accurate dynamic models for IBRs to predict how power systems will adapt to varying levels of IBRs penetration, establish grid code requirements, and ensure compliance. Here, this study introduces an active probing signal-based data-driven modeling technique to accurately derive the dynamics model of a smart photovoltaic inverter operating in Volt-Watt and Freq-Watt modes, in compliance with the IEEE 1547–2018 standard. The paper focuses on investigating how the dynamics of the PV inverter model respond to fluctuations in solar irradiance, utilizing real-time digital simulator experimentation. The experimental analysis demonstrates that the amplitude of dynamics fluctuates with changes in irradiance across both operational modes and confirms the active power’s dependence on irradiance levels. Furthermore, the nature of inverter dynamics varies distinctly between the different modes of activation. Critically, our findings indicate that dynamic models require DC-gain adjustments to accommodate contrasting irradiance levels, highlighting a negative gradient linear relationship between the DC-gain of each model and the irradiance.
Momentary cessation (MC) and response to rate-of-change-of-frequency (ROCOF) are inverter responses that can have serious impact on the stability of the grid during abnormal conditions. Though IEEE Std 1547-2018 provides fairly well defined expected responses from inverter-based DERs during abnormal grid conditions, a significant portion of currently installed DERs in the distribution network do not have a well defined response to abnormal grid conditions. Any analysis of the grid involving inverter MC and ROCOF response must consider the specific characteristics of these responses for the installed DERs to have better confidence in the analysis results, especially for grids with high levels of DERs. However, there is lack of information on MC and ROCOF response for the inverters already installed in the field. In this paper, we examine a large data set of installed inverters to map the dominant population of installed inverters. This information is then used to characterize the most dominant MC and ROCOF responses of installed inverters using experimental data.
Here, we present two methods to identify the admittance of a 2.3-MVA commercial grid-following inverter through frequency-domain data and time-domain data. In addition to the well-known harmonic injection method to obtain the admittance at frequency points followed by vector fitting, we adopt a step response-based method where the step response data of the converter are collected and their s-domain expressions are obtained. In turn, the s-domain admittance model of the converter is found. The two methods can be used for cross validation. Step responses and frequency-domain responses obtained from the two methods are compared. Results show that the time- domain data-based method leads to an admittance comparable with that from the frequency-domain measurement in the range less than 60 Hz. In addition, two insights are obtained from the frequency-domain admittance measurements. First, when the dq- frame is aligned to the point of common coupling (PCC) voltage, the per unit DQ-domain admittance directly reflects operating conditions. Second, existence of negative-sequence control can be detected via sequence-domain admittances.
Abstract The problem of phase retrieval underlies various imaging methods from astronomy to nanoscale imaging. Traditional phase retrieval methods are iterative and are therefore computationally expensive. Deep learning (DL) models have been developed to either provide learned priors or completely replace phase retrieval. However, such models require vast amounts of labeled data, which can only be obtained through simulation or performing computationally prohibitive phase retrieval on experimental datasets. Using 3D X-ray Bragg coherent diffraction imaging (BCDI) as a representative technique, we demonstrate AutoPhaseNN, a DL-based approach which learns to solve the phase problem without labeled data. By incorporating the imaging physics into the DL model during training, AutoPhaseNN learns to invert 3D BCDI data in a single shot without ever being shown real space images. Once trained, AutoPhaseNN can be effectively used in the 3D BCDI data inversion about 100× faster than iterative phase retrieval methods while providing comparable image quality.
Not Available
This study evaluates the chemo-mechanical influence of injected CO 2 on the Morrow B sandstone reservoir and the upper Morrow shale caprock utilizing data from the inverted 5-spot pattern centered on Well 13-10A within the Farnsworth unit (FWU). This study also seeks to evaluate the integrity of the caprock and the long-term CO 2 storage capability of the FWU. The inverted 5-spot pattern was extracted from the field-scale model and tuned with the available field observed data before the modeling work. Two coupled numerical simulation models were utilized to continue the study. First, a coupled hydro-geochemical model was constructed to simulate the dissolution and precipitation of formation minerals by modeling three intra-aqueous and six mineral reactions. In addition, a coupled hydro-geomechanical model was constructed and employed to study the effects of stress changes on the caprock’s porosity, permeability, and ground displacement. The Mohr–Coulomb circle and failure envelope were used to determine caprock failure. In this work, the CO 2 -WAG injection is followed by the historical field-observed strategy. During the forecasting period, a Water Alternating Gas (WAG) injection ratio of 1:3 was utilized with a baseline bottom-hole pressure constraint of 5500 psi for 20 years. A post-injection period of 1000 years was simulated to monitor the CO 2 plume and its effects on the CO 2 storage reservoir and caprock integrity. The simulation results indicated that the impacts of the geochemical reactions on the porosity of the caprock were insignificant as it experienced a decrease of about 0.0003% at the end of the 1000-year post-injection monitoring. On the other hand, the maximum stress-induced porosity change was about a 1.4% increase, resulting in about 4% in permeability change. It was estimated that about 3.3% of the sequestered CO 2 in the formation interacted with the caprock. Despite these petrophysical property alterations and CO 2 interactions in the caprock, the caprock still maintained its elastic properties and was determined to be far from its failure.
The analysis of scientific simulations is highly data-intensive and is becoming an increasingly important challenge. Peta-scale data sets require the use of light-weight query-driven analysis methods, as opposed to heavy-weight schemes that optimize for speed at the expense of size. This paper is an attempt in the direction of query processing over losslessly compressed scientific data. We propose a co-designed double-precision compression and indexing methodology for range queries by performing unique-value-based binning on the most significant bytes of double precision data (sign, exponent, and most significant mantissa bits), and inverting the resulting metadata to produce an inverted index over a reduced data representation. Without the inverted index, our method matches or improves compression ratios over both general-purpose and floating-point compression utilities. The inverted index is light-weight, and the overall storage requirement for both reduced column and index is less than 135%, whereas existing DBMS technologies can require 200-400%. As a proof-of-concept, we evaluate univariate range queries that additionally return column values, a critical component of data analytics, against state-of-the-art bitmap indexing technology, showing multi-fold query performance improvements.
Not Available
The reliability of photovoltaic (PV) inverters is critical for long-term solar system performance, with cooling fan failures frequently leading to costly downtime. While much research exists on general cooling fan reliability, little attention has been given to fans operating within PV inverters and their unique environmental challenges. Here, this article proposes a comprehensive methodology to address this gap. First, a failure mode and effects analysis is performed on fans to identify the key failure mechanisms in PV applications, their corresponding stressors, and the models necessary for lifetime prediction. Second, an accelerated life test is designed and conducted to collect valuable experimental data for PV inverter fans in a reasonable amount of time. Third, a mathematical conversion of dynamic mission profiles into effective constant stress levels is derived. Fourth, case studies are given, showcasing lifetime estimates that account for geographic variations in mission profile data. The results demonstrate that this integrated approach leads to an accurate reliability assessment for PV inverter cooling fans.
Here, in this paper, we develop a novel gray-box modeling approach for distribution systems with inverter-based resources (IBRs). The proposed gray-box modeling method aims to improve estimation accuracy by taking advantages of both physics-based (white-box) and data-driven (black-box) modeling approaches. To this end, we utilize partial physical knowledge of the system, including the inverters’ structures and control diagrams, as well as the equivalent network model simplified through Kron reduction. The white-box model containing unknown parameters is then constructed with mathematical equations and an optimization-based method is subsequently employed to identify these unknown parameters within the white-box model. Next, the graybox modeling framework is then constructed by embedding the output variables of the white-box model into the input vector of a black-box model (represented using a neural network). Finally, the black-box section is trained using the collected input-output datasets and the gray-box model is then obtained. Furthermore, case studies demonstrate that our gray-box modeling approach effectively improves estimation accuracy compared to purely physics-based or data-driven methods.
This project is to develop a data management and analytics platform called Grid Data Crossing (GriD-Xing) that integrates data processing, storage, analysis, and visualization functionalities for users at industry (e.g., EMS and DMS) and universities. It intends to increase the applicability of large set of multi-source data (e.g., SCADA, PMU, μPMU, AMI, inverter, load/DER forecasting, and cyber data) and eventually improve the resilience, reliability, and security of critical energy infrastructure. GriD-Xing also intends to be a research platform to identify the usefulness of large multi-source data via case studies of interest to industry (e.g., 2011 southwest cold weather and 2016 Blue Cut fire events). In the first year, the team focused on the development and demonstration of large multi-source data (e.g., PMU, μPMU, SCADA, AMI, and cyber data) processing, storage, and analysis. Specifically, the team designed GriD-Xing framework in functional and structural aspects, developed GriD-Xing algorithms for large multi-source grid data processing, storage, and analysis, and finally demonstrated GriD-Xing prototype algorithms performance through a series of tests and case studies using real-world and simulation data.
Double-difference waveform inversion is a promising tool for quantitative monitoring for enhanced geothermal systems (EGS). The method uses time-lapse seismic data to jointly inverts for reservoir changes. Due to the ill-posedness of waveform inversion, it is a great challenge to obtain reservoir changes accurately and efficiently, particularly when using timelapse seismic reflection data. To improve reconstruction, we develop a spatially-variant total-variation regularization scheme into double-difference waveform inversion to improve the inversion accuracy and robustness. The new regularization scheme employs different regularization parameters in different regions of the model to obtain an optimal regularization in each area. We compare the results obtained using a spatially-variant parameter with those obtained using a constant regularization parameter. Utilizing a spatially-variant regularization scheme, the target monitoring regions are well reconstructed and the image noise is significantly reduced outside the monitoring regions. Our numerical examples demonstrate that the spatially-variant total-variation regularization scheme provides the flexibility to regularize local regions based on the a priori spatial information without increasing computational costs and the computer memory requirement.
Pressure data measured in monitoring wells during well tests are typically used to estimate subsurface boundaries, but the resolution of this technique is often limited. We have shown that the strain tensor at shallow depth can be measured with optical strainmeters, and this signal responds to pressure changes in an underlying aquifer or reservoir. Moreover, these data can be inverted to estimate reservoir properties using analyses similar to classical type-curve analyses. The objective of this investigation is to evaluate the feasibility of extending the type-curve analysis of strain tensor data to include the characterization of aquifer boundaries.
In this report the experimental determination of neutral densities in tokamak plasmas from line radiation is only accurate in the narrow region in which both the excitation rate and neutral density are significant. We describe an alternative procedure using the DEGAS 2 Monte Carlo neutral transport code to invert light emission data obtained from a tangentially viewing camera, yielding absolute radial profiles of deuterium atoms and molecules at midplane. That the neutral source in these simulations can be adequately characterized as a uniform flux at the vacuum vessel wall is demonstrated by the similarity of the shapes of the simulated and observed brightness profiles. A second test is obtained by comparing the resulting neutral pressures at the vessel walls with data from midplane micro-ion gauges. We also show that the simulated camera image is insensitive to variations in the spatial distribution of the neutral source.