Search NASA⌕ Search

SEARCH · Search NASA

Results for “ion channels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Ion Velocity in the Discharge Channel and Near-Field of the HERMeS Hall Thruster

NASA is continuing the development of a 12.5-kW Hall thruster system, which is baselined in a phased exploration concept to expand human presence to cis-lunar space and eventually to Mars. The development team is transitioning knowledge gained from the testing of the government-built Technology Development Unit (TDU) to the contractor-built Engineering Development Unit (EDU). A new laser-induced fluorescence diagnostic that is compatible with the testing of engineering hardware was developed to obtain data for thruster model validation in the lowest background pressure achievable. Prior to performing the test on the EDU, the team performed a functional checkout test of this new diagnostic using the TDU. In addition to providing a checkout of the diagnostic, this test provided data that can be correlated to electron mobility for comparison to the EDU at a later date. A number of technical challenges related to large test facilities and interfacing with engineering hardware were overcome while implementing the new laser diagnostic system. The initial data set was in good agreement with prior optical and non-optical diagnostics data collected on the TDU thrusters. This data set also revealed the spatial origin of high angle ions that have been of concern for spacecraft integration.

Huang, Wensheng↗

Ion Velocity in the Discharge Channel and Near-Field of the HERMeS Hall Thruster

NASA is continuing the development of a 12.5-kW Hall thruster system, which is baselined in a phased exploration concept to expand human presence to cis-lunar space and eventually to Mars. The development team is transitioning knowledge gained from the testing of the government-built Technology Development Unit (TDU) to the contractor-built Engineering Development Unit (EDU). A new laser-induced fluorescence diagnostic that is compatible with the testing of engineering hardware was developed to obtain data for thruster model validation in the lowest background pressure achievable. Prior to performing the test on the EDU, the team performed a functional checkout test of this new diagnostic using the TDU. In addition to providing a checkout of the diagnostic, this test provided data that can be correlated to electron mobility for comparison to the EDU at a later date. A number of technical challenges related to large test facilities and interfacing with engineering hardware were overcome while implementing the new laser diagnostic system. The initial data set was in good agreement with prior optical and non-optical diagnostics data collected on the TDU thrusters. This data set also revealed the spatial origin of high angle ions that have been of concern for spacecraft integration.

Huang, Wensheng↗

Parathyroid hormone enhances fluid shear-induced [Ca2+]i signaling in osteoblastic cells through activation of mechanosensitive and voltage-sensitive Ca2+ channels

Osteoblasts respond to both fluid shear and parathyroid hormone (PTH) with a rapid increase in intracellular calcium concentration ([Ca2+]i). Because both stimuli modulate the kinetics of the mechanosensitive cation channel (MSCC), we postulated PTH would enhance the [Ca2+]i response to fluid shear by increasing the sensitivity of MSCCs. After a 3-minute preflow at 1 dyne/cm2, MC3T3-E1 cells were subjected to various levels of shear and changes in [Ca2+]i were assessed using Fura-2. Pretreatment with 50 nM bovine PTH(1-34) [bPTH(1-34)] significantly enhanced the shear magnitude-dependent increase in [Ca2+]i. Gadolinium (Gd3+), an MSCC blocker, significantly inhibited the mean peak [Ca2+]i response to shear and shear + bPTH(1-34). Nifedipine (Nif), an L-type voltage-sensitive Ca2+ channel (VSCC) blocker, also significantly reduced the [Ca2+]i response to shear + bPTH(1-34), but not to shear alone, suggesting VSCC activation plays an interactive role in the action of these stimuli together. Activation of either the protein kinase C (PKC) or protein kinase A (PKA) pathways with specific agonists indicated that PKC activation did not alter the Ca2+ response to shear, whereas PKA activation significantly increased the [Ca2+]i response to lower magnitudes of shear. bPTH(1-34), which activates both pathways, induced the greatest [Ca2+]i response at each level of shear, suggesting an interaction of these pathways in this response. These data indicate that PTH significantly enhances the [Ca2+]i response to shear primarily via PKA modulation of the MSCC and VSCC.

Non-NASA Center↗

Development of a fast ion mass spectrometer for space research

An ion mass spectrometer having a cylindrical E bar x B bar analyzer and either a cylindrical or spherical electrostatic analyzer is described. The instrument has two nested channels and a postacceleration between the electrostatic and E bar x B bar analyzers for wide ranges of energy and mass responses. It is noted that the dual-channel construction not only doubles the data acquisition rate but also permits a reversal of the electrostatic field orientation in the inner channel for lighter ions. The outer channel is then optimized for ions of medium to high mass numbers, resulting in increased mass resolution for such heavy ions. When combined with a cylindrical E bar x B bar analyzer, a 90-deg-deflection angle spherical electrostatic analyzer provides an extremely wide viewing angle. The angular distribution of ions can be derived from such geometry if a position-sensitive resistive anode or a detector array is used at the exit aperture. Details on the principles of operation, the instrument design, and calibration are presented.

Hahn, S. F.↗

Structural models of the MscL gating mechanism

Three-dimensional structural models of the mechanosensitive channel of large conductance, MscL, from the bacteria Mycobacterium tuberculosis and Escherichia coli were developed for closed, intermediate, and open conformations. The modeling began with the crystal structure of M. tuberculosis MscL, a homopentamer with two transmembrane alpha-helices, M1 and M2, per subunit. The first 12 N-terminal residues, not resolved in the crystal structure, were modeled as an amphipathic alpha-helix, called S1. A bundle of five parallel S1 helices are postulated to form a cytoplasmic gate. As membrane tension induces expansion, the tilts of M1 and M2 are postulated to increase as they move away from the axis of the pore. Substantial expansion is postulated to occur before the increased stress in the S1 to M1 linkers pulls the S1 bundle apart. During the opening transition, the S1 helices and C-terminus amphipathic alpha-helices, S3, are postulated to dock parallel to the membrane surface on the perimeter of the complex. The proposed gating mechanism reveals critical spatial relationships between the expandable transmembrane barrel formed by M1 and M2, the gate formed by S1 helices, and "strings" that link S1s to M1s. These models are consistent with numerous experimental results and modeling criteria.

NASA Discipline Cell Biology↗

Effects of ionizing radiation on CCD's

The effects of 1.2 MeV gamma radiation and 20 MeV electrons on the operational characteristics of CCDs are studied. The effects of ionizing radiation on the charge transfer efficiency, dark current, and input/output circuitry are described. The improved radiation hardness of buried channel CCDs is compared to surface channel results. Both ion implanted and epitaxial layer buried channel device results are included. The advantages of using a single thickness SiO2 gate dielectric are described. The threshold voltage shifts and surface state density changes of dry, steam, and HCl doped oxides are discussed. Recent results on the recovery times and total dose effects of high dose rate pulses of 20 MeV electrons are reported.

Hartsell, G. A.↗

Epitaxial yttria-stabilized zirconia on (1 -1 0 2) sapphire for YBa2Cu3O(7-delta) thin films

Epitaxial yttria-stabilized zirconia (YSZ) films were deposited on (1 -1 0 2) sapphire by pulsed laser deposition. The films are formed in a cubic phase with the a axis normal to the substrate surface. Ion beam channeling measurements show that the YSZ films are highly crystalline with a channeling minimum yield of 8 percent. The epitaxial relationship between the film and substrate is further confirmed by a cross-section TEM study. Epitaxial YBa2Cu3O(7-delta) thin films deposited on YSZ/sapphire have Tc and Jc of up to 89 K and 10 to the 6th A/sq cm at 77 K, respectively.

Wu, X. D.↗

Buffer layers for high-Tc thin films on sapphire

Buffer layers of various oxides including CeO2 and yttrium-stabilized zirconia (YSZ) have been deposited on R-plane sapphire. The orientation and crystallinity of the layers were optimized to promote epitaxial growth of YBa2Cu3O(7-delta) (YBCO) thin films. An ion beam channeling minimum yield of about 3 percent was obtained in the CeO2 layer on sapphire, indicating excellent crystallinity of the buffer layer. Among the buffer materials used, CeO2 was found to be the best one for YBCO thin films on R-plane sapphire. High Tc and Jc were obtained in YBCO thin films on sapphire with buffer layers. Surface resistances of the YBCO films were about 4 mOmega at 77 K and 25 GHz.

Wu, X. D.↗

Ammonia in comet P/Halley

In comet P/Halley the abundances of ammonia relative to water reported in the literature differ by about one order of magnitude from roughly 0.1% up to 2%. Different observational techniques seem to have inherent systematic errors. Using the ion mass channels m/q = 19 amu/e, 18 amu/e and 17 amu/e of the Neutral Mass Spectrometer experiment aboard the spacecraft Giotto, we derive a production rate of ammonia of (1.5(sub -0.7)(sup +0.5))% relative to water. Inside the contact surface we can explain our data by a nuclear source only. The uncertainty in our abundance of ammonia is primarily a result of uncertainties in some key reaction coefficients. We discuss in detail these reactions and the range of error indicated results from extreme assumptions in the rate coefficients. From our data, even in the worst case, we can exclude the ammonia abundance to be only of the order of a few per mill.

Meier, R.↗

Measurement of OH, H2SO4, MSA, DMSO, DMSO2 on the NASA P-3B Aircraft

This project involves the deployment of a variety of unique aircraft measurements for the PEM-Tropics program. These measurements were all to be accomplished on a near simultaneous basis using a two channel selected ion chemical ionization mass spectrometer instrument. The first year of this project consisted of four components; improve and perform additional testing of the OH, H2SO4, and MSA instrument which had only flown on one previous mission (ACE-I); develop and test the vacuum and electronic hardware and software which would allow two independent mass spectrometer systems to be operated from a single instrument (one vacuum/pumping system); construct an aircraft compatible DMSO/DMS02 ion source and calibration system; and operate the above system on the NASA P-3B during PEM-Tropics. The first two of the components were to be accomplished at NCAR. The third component was to be completed at Georgia Tech and the fourth was to be conducted by researchers from both institutions on the NASA P-3B.

Eisele, F. L.↗

Transduction of mechanical strain in bone

One physiologic consequence of extended periods of weightlessness is the rapid loss of bone mass associated with skeletal unloading. Conversely, mechanical loading has been shown to increase bone formation and stimulate osteoblastic function. The mechanisms underlying mechanotransduction, or how the osteoblast senses and converts biophysical stimuli into cellular responses has yet to be determined. For non-innervated mechanosensitive cells like the osteoblast, mechanotransduction can be divided into four distinct phases: 1) mechanocoupling, or the characteristics of the mechanical force applied to the osteoblast, 2) biochemical coupling, or the mechanism through which mechanical strain is transduced into a cellular biochemical signal, 3) transmission of signal from sensor to effector cell and 4) the effector cell response. This review examines the characteristics of the mechanical strain encountered by osteoblasts, possible biochemical coupling mechanisms, and how the osteoblast responds to mechanical strain. Differences in osteoblastic responses to mechanical strain are discussed in relation to the types of strain encountered and the possible transduction pathways involved.

Review, Tutorial↗

Rod-Coil Block Polyimide Copolymers

This invention is a series of rod-coil block polyimide copolymers that are easy to fabricate into mechanically resilient films with acceptable ionic or protonic conductivity at a variety of temperatures. The copolymers consist of short-rigid polyimide rod segments alternating with polyether coil segments. The rods and coil segments can be linear, branched or mixtures of linear and branched segments. The highly incompatible rods and coil segments phase separate, providing nanoscale channels for ion conduction. The polyimide segments provide dimensional and mechanical stability and can be functionalized in a number of ways to provide specialized functions for a given application. These rod-coil black polyimide copolymers are particularly useful in the preparation of ion conductive membranes for use in the manufacture of fuel cells and lithium based polymer batteries.

Mary Ann B Meador↗

Polymer Energy Rechargeable System Battery Being Developed

Long description. Illustrations of discotic liquid crystals, rod-coil polymers, lithium-ion conducting channel dilithium phthalocyanine (Li2Pc) from top and side, novel star polyethylene oxide structures, composite polyethylene oxide materials (showing polyethylene oxide + lithium salt, carbon atoms and oxygen atoms), homopolyrotaxanes, and diblock copolymers In fiscal year 2000, NASA established a program to develop the next generation, lithium-based, polymer electrolyte batteries for aerospace applications. The goal of this program, known as Polymer Energy Rechargeable Systems (PERS), is to develop a space-qualified, advanced battery system embodying polymer electrolyte and lithium-based electrode technologies and to establish world-class domestic manufacturing capabilities for advanced batteries with improved performance characteristics that address NASA s future aerospace battery requirements.

Manzo, Michelle A.↗

Miniaturized ultrafine particle sizer and monitor

An apparatus for measuring particle size distribution includes a charging device and a precipitator. The charging device includes a corona that generates charged ions in response to a first applied voltage, and a charger body that generates a low energy electrical field in response to a second applied voltage in order to channel the charged ions out of the charging device. The corona tip and the charger body are arranged relative to each other to direct a flow of particles through the low energy electrical field in a direction parallel to a direction in which the charged ions are channeled out of the charging device. The precipitator receives the plurality of particles from the charging device, and includes a disk having a top surface and an opposite bottom surface, wherein a predetermined voltage is applied to the top surface and the bottom surface to precipitate the plurality of particles.

Chen, Da-Ren↗

Hydrocarbon Ions in the Ionospheres of Titan and Jupiter

Two examples are given of models of ion chemistry in reducing atmospheres: Titan, which is a satellite of Saturn, and Jupiter, the largest of the gas giants. In both ionospheres, layers of hydrocarbon and/or C, H, and N-containing ions have been predicted to appear, with larger ions dominating at lower altitudes. Altitude profiles are presented for individual C1- and C2-hydrocarbon ions and larger ions that are represented for example, as C(x)H(y)(+) and C(x)H(y)N(x)(+). The accuracy of the predictions is, however, limited by the availability of information about the chemistry of these ions. In addition to rate coefficients and product channels for ion-molecule reactions, dissociative recombination coefficients and branching ratios are needed for many hydrocarbon and and related ions.

Fox, J. L.↗

Etching of diamond with argon and oxygen ion beams

The angular dependences of the sputter yield of (100) single crystal diamond under argon and oxygen ion beams were investigated. For argon ion beams a large increase in the sputter yield was observed as the angle of incidence was increased from the normal, with a maximum occurring at approximately 60 deg from the normal. The magnitude of the increase and the angle at which the maximum was observed were dependent on the ion energy and species. The shape of the yield versus angle of incidence curve indicated the presence of a highly damaged surface layer. Large deviations from this curve were observed where ion incidence was along channeling directions. Studies with oxygen ion beams showed almost no angular dependence for 500 eV ions while at an energy of 1000 eV the angular dependence was similar to that for argon ions. At normal incidence the yield for 500 eV oxygen ions was seven times larger than that for 500 eV argon ions. For 1000 eV oxygen and argon ions the corresponding ratio is only 2.5. Implications for mechanisms of inert and reactive ion etching are discussed. Application of the data to ion beam shaping of diamond tips for ultrahigh pressure research is discussed.

Whetten, T. J.↗