Search NASA⌕ Search

SEARCH · Search NASA

Results for “large optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Oriented Scintillation Spectrometer Experiment observations of Co-57 in SN 1987A

The Oriented Scintillation Spectrometer Experiment (OSSE) on the Compton Gamma Ray Observatory has observed SN 1987A for two 2 week periods during the first 9 months of the mission. Evidence for gamma-ray line and continuum emission from Co-57 is observed with an intensity of about 10 exp -4 gamma/sq cm/s. This photon flux between 50 and 136 keV is demonstrated by Monte Carlo calculations to be independent of the radial distribution of Co-57 for models of low optical depth, viz., models having photoelectric absorption losses of 122 keV photons no greater than several percent. For such models the observed Co-57 flux indicates that the ratio Ni-57/Ni-56 produced in the explosion was about 1.5 times the solar system ratio of Fe-57/Fe-56. When compared with nearly contemporaneous bolometric estimates of the luminosity for SN 1987A, our observations imply that Co-57 radioactivity does not account for most of the current luminosity of the supernova remnant in low optical depth models. We suggest alternatives, including a large optical depth model that is able to provide the SN 1987A luminosity and is consistent with the OSSE flux. It requires a 57/56 production ratio about twice solar.

Kurfess, J. D.↗

Optical Design and Status of the Large Ultra-Violet Optical Infrared Surveyor (LUVOIR)

"In preparation for the Astrophysics 2020 Decadal Survey NASA's Goddard Space Flight Center is studying a segmented aperture telescope with broad astrophysics, solar system, and exoplanet science capability called the Large Ultra-Violet Optical Infrared Surveyor (LUVOIR). This telescope design incorporates many heritage design concepts from the Hubble Space Telescope (HST), James Webb Space Telescope (JWST), and the Wide-field Infrared Survey Telescope (WFIRST). This includes similar ultraviolet instrumentation from HST, deployable segmented optics from JWST, and high-contrast coronagraph technology from WFIRST. Several optical design trades were completed to maximize the science product while maintaining reasonable packaging and fabrication constraints. Other technology developments such as freeform optics, UV enhanced coatings, coronagraph design, and ultra-stable mirrors are being studied to further improve the observatory performance.

Ultraviolet↗

Combined Retrievals of Boreal Forest Fire Aerosol Properties with a Polarimeter and Lidar

Absorbing aerosols play an important, but uncertain, role in the global climate. Much of this uncertainty is due to a lack of adequate aerosol measurements. While great strides have been made in observational capability in the previous years and decades, it has become increasingly apparent that this development must continue. Scanning polarimeters have been designed to help resolve this issue by making accurate, multi-spectral, multi-angle polarized observations. This work involves the use of the Research Scanning Polarimeter (RSP). The RSP was designed as the airborne prototype for the Aerosol Polarimetery Sensor (APS), which was due to be launched as part of the (ultimately failed) NASA Glory mission. Field observations with the RSP, however, have established that simultaneous retrievals of aerosol absorption and vertical distribution over bright land surfaces are quite uncertain. We test a merger of RSP and High Spectral Resolution Lidar (HSRL) data with observations of boreal forest fire smoke, collected during the Arctic Research of the Composition of the Troposphere from Aircraft and Satellites (ARCTAS). During ARCTAS, the RSP and HSRL instruments were mounted on the same aircraft, and validation data were provided by instruments on an aircraft flying a coordinated flight pattern. We found that the lidar data did indeed improve aerosol retrievals using an optimal estimation method, although not primarily because of the constraints imposed on the aerosol vertical distribution. The more useful piece of information from the HSRL was the total column aerosol optical depth, which was used to select the initial value (optimization starting point) of the aerosol number concentration. When ground based sun photometer network climatologies of number concentration were used as an initial value, we found that roughly half of the retrievals had unrealistic sizes and imaginary indices, even though the retrieved spectral optical depths agreed within uncertainties to independent observations. The convergence to an unrealistic local minimum by the optimal estimator is related to the relatively low sensitivity to particles smaller than 0.1 ( m) at large optical thicknesses. Thus, optimization algorithms used for operational aerosol retrievals of the fine mode size distribution, when the total optical depth is large, will require initial values generated from table look-ups that exclude unrealistic size/complex index mixtures. External constraints from lidar on initial values used in the optimal estimation methods will also be valuable in reducing the likelihood of obtaining spurious retrievals.

Knobelspiesse, K.↗

Evidence for X-ray emission from flare stars observed by ANS

Observations that detected the first X-ray emission from flare stars are described. An X-ray flare was detected from YZ CMi at 0.28 keV and approximately 1-7 keV, although no optical or radio coverage was available. During a very large optical flare from UV Ceti, X-ray emission at (only) 0.28 keV was detected. Upper limits for X-ray emission from several small optical flares of UV Ceti are presented. Implications for X-ray flare models, the diffuse X-ray background, and low-energy cosmic-ray flux are mentioned.

Heise, J.↗

Observations of X-rays from flare stars with ANS

Observations during which X-ray emission from flare stars was detected for the first time, are described. An X-ray flare was detected from YZ CMi at 0.28 keV and 1-7 keV, although no optical or radio coverage was available. During a very large optical flare from UV Ceti, X-ray emission at 0.28 keV only was detected. Upper limits for X-ray emission from several small optical flares of UV Ceti are obtained. Implications for X-ray flare models, the diffuse X-ray background, and low-energy cosmic-ray flux are examined.

Grindlay, J.↗

Radiative transfer in spherical dust shells using a generalized two-stream Eddington approximation

Application of a generalized two-stream Eddington approximation to the problem of radiative transfer in extended, spherically symmetric dust shells is presented. It is assumed that the radiation field can be characterized by the mean intensity, the flux, and a positionally dependent direction cosine specifying the division into two solid-angle ranges. The direction cosine is not specified a priori and is a function of the geometry, opacity, and emissivity in the dust shell. A multiple-grain-size multiple-temperature-distribution dust shell is postulated in which isotropic and anisotropic scattering as well as absorption and thermal reemission are allowed. A program has been developed that solves for the multiple temperature distributions by applying the constraint of radiative equilibrium to each grain size, and then calculates emergent fluxes. Results of one such calculation are presented for a model dust shell having a maximum optical depth (approximately 41) in the visible, clearly showing large optical extinction and a moderate infrared excess.

Haisch, B. M.↗

An Array of Optical Receivers for Deep-Space Communications

An array of small optical receivers is proposed as an alternative to a single large optical receiver for high-data-rate communications in NASA s Deep Space Network (DSN). Because the telescope for a single receiver capable of satisfying DSN requirements must be greater than 10 m in diameter, the design, building, and testing of the telescope would be very difficult and expensive. The proposed array would utilize commercially available telescopes of 1-m or smaller diameter and, therefore, could be developed and verified with considerably less difficulty and expense. The essential difference between a single-aperture optical-communications receiver and an optical-array receiver is that a single-aperture receiver focuses all of the light energy it collects onto the surface of an optical detector, whereas an array receiver focuses portions of the total collected energy onto separate detectors, optically detects each fractional energy component, then combines the electrical signal from the array of detector outputs to form the observable, or "decision statistic," used to decode the transmitted data. A conceptual block diagram identifying the key components of the optical-array receiver suitable for deep-space telemetry reception is shown in the figure. The most conspicuous feature of the receiver is the large number of small- to medium-size telescopes, with individual apertures and number of telescopes selected to make up the desired total collecting area. This array of telescopes is envisioned to be fully computer- controlled via the user interface and prediction-driven to achieve rough pointing and tracking of the desired spacecraft. Fine-pointing and tracking functions then take over to keep each telescope pointed toward the source, despite imperfect pointing predictions, telescope-drive errors, and vibration caused by wind.

Vilnrotter, Chi-Wung↗

Improvements in Mirror Surface Measurement with Reflected Computer Vision Targets

Over the last several years, NREL has been developing a system to measure large optical surfaces of heliostat mirrors by reflecting computer vision targets. An advantage of this system, called Reflected Target Nonintrusive Assessment (ReTNA), is that it lends itself well to stitching together many images, each reflecting only part of a larger heliostat. In the last few months, this was taken to a new extreme, with a small target (<5m2) being used to measure a >25m2 long focal length heliostat. These measurements were compared with traditional fringe deflectometry methods, which require a >50m2 target, and photogrammetry. The strengths, weaknesses and limitations of ReTNA are discussed. An estimated uncertainty in this new measurement is presented, along with software improvements and a new wireless data collection system. A bill of materials for this measurement system is presented, which has been designed to use all low-cost, off-the-shelf components. Finally, the next steps for future ReTNA development are presented. Overall, ReTNA can be a valuable optics measurement system, complimentary to existing measurement techniques available for large reflective surfaces.

14 SOLAR ENERGY↗

Giant Modulation of Refractive Index from Picoscale Atomic Displacements

Abstract It is shown that structural disorder—in the form of anisotropic, picoscale atomic displacements—modulates the refractive index tensor and results in the giant optical anisotropy observed in BaTiS 3 , a quasi‐1D hexagonal chalcogenide. Single‐crystal X‐ray diffraction studies reveal the presence of antipolar displacements of Ti atoms within adjacent TiS 6 chains along the c ‐axis, and threefold degenerate Ti displacements in the a – b plane. 47/49 Ti solid‐state NMR provides additional evidence for those Ti displacements in the form of a three‐horned NMR lineshape resulting from a low symmetry local environment around Ti atoms. Scanning transmission electron microscopy is used to directly observe the globally disordered Ti a–b plane displacements and find them to be ordered locally over a few unit cells. First‐principles calculations show that the Ti a – b plane displacements selectively reduce the refractive index along the ab ‐plane, while having minimal impact on the refractive index along the chain direction, thus resulting in a giant enhancement in the optical anisotropy. By showing a strong connection between structural disorder with picoscale displacements and the optical response in BaTiS 3 , this study opens a pathway for designing optical materials with high refractive index and functionalities such as large optical anisotropy and nonlinearity.

36 MATERIALS SCIENCE↗

Optically induced excitonic electroabsorption in a periodically delta-doped InGaAs/GaAs multiple quantum well structure

Large optically induced Stark shifts have been observed in a periodically delta-doped InGaAs/GaAs multiple quantum well structure. With an excitation intensity of 10 mW/sq cm, an absolute quantum well absorption change of 7000/cm was measured with a corresponding differential absorption change as high as 80 percent. The associated maximum change in the quantum well refractive index is 0.04. This material is promising for device development for all-optical computing and signal processing.

Larsson, A.↗

The New LOTIS Test Facility

The Large Optical Test and Integration Site (LOTIS) at the Lockheed Martin Space Systems Company in Sunnyvale, CA is designed for the verification and testing of optical systems. The facility consists of an 88 foot temperature stabilized vacuum chamber that also functions as a class 10k vertical flow cleanroom. Many problems were encountered in the design and construction phases. The industry capability to build large chambers is very weak. Through many delays and extra engineering efforts, the final product is very good. With 11 Thermal Conditioning Units and precision RTD s, temperature is uniform and stable within 1oF, providing an ideal environment for precision optical testing. Within this chamber and atop an advanced micro-g vibration-isolation bench is the 6.5 meter diameter LOTIS Collimator and Scene Generator, LOTIS alignment and support equipment. The optical payloads are also placed on the vibration bench in the chamber for testing. This optical system is designed to operate in both air and vacuum, providing test imagery in an adaptable suite of visible/near infrared (VNIR) and midwave infrared (MWIR) point sources, and combined bandwidth visible-through-MWIR point sources, for testing of large aperture optical payloads. The heart of the system is the LOTIS Collimator, a 6.5m f/15 telescope, which projects scenes with wavefront errors <85 nm rms out to a 0.75 mrad field of view (FOV). Using field lenses, performance can be extended to a maximum field of view of 3.2 mrad. The LOTIS Collimator incorporates an extensive integrated wavefront sensing and control system to verify the performance of the system.

Bell, R. M.↗

Comprehensive anisotropic linear optical properties of the Weyl semimetals TaAs and NbAs

We report that TaAs and NbAs are two of the earliest identified Weyl semimetals that possess many intriguing optical properties, such as chirality-dependent optical excitations and giant second harmonic generation (SHG). Linear and nonlinear optics have been employed as tools to probe the Weyl physics in these crystals. Here, we extend these studies to address two important aspects: determining the complete anisotropic dielectric response and exploring if and how they can reveal essential Weyl physics. We determine the complete anisotropic dielectric functions of TaAs and NbAs by combining spectroscopic ellipsometry and density functional theory (DFT). Parameterized Lorentz oscillators are reported from 1.2 - 6 eV (experiment) and 0 - 6 eV (DFT), and good agreement is shown between them. Both linear and nonlinear optical properties have been previously reported to reveal Weyl physics. We suggest that strong optical resonances from trivial bands are the likely origin of the large optical SHG previously reported at these energies. Furthermore, by comparing the contribution of a small k -space centered around the Weyl cones with the total linear dielectric function, we find that these contributions are highly anisotropic and are < 25% of the total dielectric function below 0.5 eV; abov1 eV, these contributions are negligible. Thus, the study of Weyl physics using optical techniques requires very low energies, and even there, a careful assessment is required in distinguishing the much smaller contributions of the Weyl bands from the dominant contributions of the trivial bands and Drude response to the total dielectric function.

36 MATERIALS SCIENCE↗

Generalized Comptonization models and application to the recent high-energy observations

The theory of spectral formation in thermal X-ray sources, where the effects of Comptonization and Klein-Nishina corrections are important, is presented. Analytical expressions are obtained for the produced spectrum as a function of such input parameters as the plasma temperature, the optical depth of the plasma cloud and the injected soft photon spectrum. The analytical theory developed here takes into account the dependence of the scattering opacity on the photon energy. It is shown that the plasma temperature as well as the asymptotic rate of photon escape from the plasma cloud determine the shape of the upscattered hard tail in the emergent spectra, even in the case of very small optical depths. The escape distributions of photons are given for any optical depth of the plasma cloud and their asymptotic dependence for very small and large optical depths are examined. It is shown that this new generalized approach can fit spectra for a large variety of hard X-ray sources and determine the plasma temperature in the region of main energy release in Cyg X-1 and the Seyfert galaxy NGC 4151.

Titarchuk, Lev↗

Optical interferometers for tests of relativistic gravity in space

A space-based astrometric interferometer with a large optical bandwidth is considered. POINTS (Precision Optical INTerferometry in Space) would measure the angular separation of two stars separated by about 90 deg on the sky with a nominal measurement error of 5 microarcseconds (mas). For a pair of mag 10 stars, the observation would require about 10 minutes. It is estimated that the instrument would measure daily the separation of two stars for each of about 60 pairs of stars; a random sequence of such measurements, if suitably redundant, contains the closure information necessary to detect and correct time dependent measurement biases to well below the nominal measurement accuracy. The 90 deg target separation permits absolute parallax measurements in all directions. A redundant observing schedule for 300 stars and 5 quasars would provide extra redundancy to compensate for the quasars' higher magnitude. If a nominal 30-day observation sequence were repeated 4 times per year for 10 years, stellar parameter uncertainties would be obtained of: 0.6 mas, position; 0.4 mas/y, proper motion; and 0.4 mas, parallax. This set of well-observed stars and quasars would form a rigid frame and the stars would serve as reference objects for measurements of all additional targets, as well as being targets of direct scientific interest. The instrument global data analysis since objectives are considered including a relativity test and technology.

Reasenberg, R. D.↗

Visibility of Halley's nucleus from the Giotto spacecraft

An effort is made to estimate the visibility of the patterns on the nucleus of Comet Halley from the Giotto spacecraft through the comet's dusty coma. The visibility computation is based on the theory of contrast reduction by a scattering and absorbing medium (a planetary atmosphere). It is shown that some details may be seen on the surface of the cometary nucleus even for an optical thickness as high as 2. It is noted that the surprisingly large apparent contrast for such large optical thicknesses can be explained by the strong forward scattering by the dust.

Mekler, Y.↗

Changes to the Appearance of Optical Lightning Flashes Observed From Space According to Thunderstorm Organization and Structure

Optical lightning observations from space reveal a wide range of flash structure. Lightning imagers such as the Geostationary Lightning Mapper and Lightning Imaging Sensor measure flash appearance by recording transient changes in cloud top illumination. The spatial and temporal optical energy distributions reported by these instruments depend on the physical structure of the flash and the distribution of hydrometeors within the thundercloud that scatter and absorb the optical emissions. This study reported herein explores how flash appearance changes according to the scale and organization of the parent thunderstorms with a focus on mesoscale convective systems. Clouds near the storm edge are frequently illuminated by large optical flashes that remain stationary between groups. These flashes appear large because their emissions can reflect off the exposed surfaces of nearby clouds to reach the satellite. Large stationary flashes also occur in small isolated thunderstorms. Optical flashes that propagate horizontally, meanwhile, are most frequently observed in electrified stratiform regions where extensive layered charge structures promote lateral development. Highly radiant “superbolts” occur in two scenarios: embedded within raining stratiform regions or in nonraining boundary/anvil clouds where optical emissions can take a relatively clear path to the satellite.

54 ENVIRONMENTAL SCIENCES↗