Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Consolidated Laser-Induced Fluorescence Diagnostic Systems for the NASA Ames Arc Jet Facilities

The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (LIF) of atomic species for non-intrusive arc jet flow property measurement was first implemented at NASA Ames in the mid-1990s. In 2013-2014, NASA combined the agency's large-scale arc jet test capabilities at NASA Ames. Concurrent with that effort, the agency also sponsored a project to establish two comprehensive LIF diagnostic systems for the Aerodynamic Heating Facility (AHF) and Interaction Heating Facility (IHF) arc jets. The scope of the project enabled further engineering development of the existing IHF LIF system as well as the complete reconstruction of the AHF LIF system. The updated LIF systems are identical in design and capability. They represent the culmination of over 20 years of development experience in transitioning a specialized laboratory research tool into a measurement system for large-scale, high-demand test facilities. This paper will document the latest improvements of the LIF system design and demonstrations of the redeveloped AHF and IHF LIF systems.

wind tunnels↗

Consolidated Laser-Induced Fluorescence Diagnostic Systems for the NASA Ames Arc Jet Facilities

The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (TALIF) of atomic species for non-intrusive arc jet flow property measurement was first implemented at NASA Ames in the mid-1990s. Use of TALIF expanded at NASA Ames and to NASA Johnsons arc jet facility in the late 2000s. In 2013-2014, NASA combined the agency's large-scale arc jet test capabilities at NASA Ames. Concurrent with that effort, the agency also sponsored a project to establish two comprehensive LIF diagnostic systems for the Aerodynamic Heating Facility (AHF) and Interaction Heating Facility (IHF) arc jets. The scope of the project enabled further engineering development of the existing IHF LIF system as well as the complete reconstruction of the original AHF LIF system. The updated LIF systems are identical in design and capability. They represent the culmination of over 20 years of development experience in transitioning a specialized laboratory research tool into a measurement system for large-scale, high-demand test facilities. This paper documents the overall system design from measurement requirements to implementation. Representative data from the redeveloped AHF and IHF LIF systems are also presented.

thermal protection materials↗

Consolidated Laser-Induced Fluorescence Diagnostic Systems for the NASA Ames Arc Jet Facilities

The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (TALIF) of atomic species for non-intrusive arc jet flow property measurement was first implemented at NASA Ames in the mid-1990s. Use of TALIF expanded at NASA Ames and to NASA Johnson's arc jet facility in the late 2000s. In 2013-2014, NASA combined the agency's large-scale arc jet test capabilities at NASA Ames. Concurrent with that effort, the agency also sponsored a project to establish two comprehensive LIF diagnostic systems for the Aerodynamic Heating Facility (AHF) and Interaction Heating Facility (IHF) arc jets. The scope of the project enabled further engineering development of the existing IHF LIF system as well as the complete reconstruction of the original AHF LIF system. The updated LIF systems are identical in design and capability. They represent the culmination of over 20 years of development experience in transitioning a specialized laboratory research tool into a measurement system for large-scale, high-demand test facilities. This paper documents the overall system design from measurement requirements to implementation. Representative data from the redeveloped AHF and IHF LIF systems are also presented.

laser spectroscopy↗

Recommended Practices in Laser-Induced Fluorescence (LIF) Diagnostics for Electric Propulsion

Laser-induced fluorescence (LIF) spectroscopy uses Doppler-shifted laser photons to excite a bound electron transition in an atom or ion, with subsequent fluorescence emission detected in order to measure the local velocity distribution function (VDF) and/or particle density. Due to its non-invasive nature, high spatial resolution, and acceptable difficulty of implementation, LIF has become a favored diagnostic for electric propulsion (EP) plasmas, particularly in the study of Hall thrusters. This paper presents recommended best practices for LIF measurements in electric thrusters, drawn from over three decades of implementation heritage in the EP community. Focusing on both single-photon LIF (typically used to measure VDFs) and two-photon LIF (TALIF, typically used to determine densities), the paper covers selection of atomic transitions to target, experimental setups, and interpretation of data. A number of special topics and advanced applications are discussed, including uncertainty analysis, techniques for high-speed measurements, and applications to a variety of propellants.

plasma plume↗

Laser absorption flow diagnostics for use in hypersonic ground-based and flight experiments

Consideration is given to laboratory ground-based scale systems for measuring OH and NO and diode laser systems for measuring O2 and H2O. Several diagnostic instruments which are currently being used in a scramjet combustor test rig of the Ames 16-inch shock tunnel are described. Data on mole fraction, temperature, density, pressure, and velocity is obtained using specific data reduction techniques. These measurements provide critical data for evaluation of the propulsion system performance which include mass capture for quantification of fuel equivalence ratio (O2), flow contamination and emission levels (NO), combustion progress (OH), and injector mixing and combustion efficiency (H2O).

Cavolowsky, John A.↗

Plasma erosion rate diagnostics using laser-induced fluorescence

An optical technique for measuring the sputtering rate of a molybdenum surface immersed in a xenon plasma has been developed and demonstrated. This approach, which may be useful in real-time wear diagnostics for ion thrusters, relies on laser-induced fluorescence to determine the density of sputtered molybdenum atoms.

Gaeta, C. J.↗

Status of Real-Time Laser Based Ion Engine Diagnostics at NASA Glenn Research Center

The development status of laser based erosion diagnostics for ion engines at the NASA Glenn Research Center is discussed. The diagnostics are being developed to enhance component life-prediction capabilities. A direct measurement of the erosion product density using laser induced fluorescence (LIF) is described. Erosion diagnostics based upon evaluation of the ion dynamics are also under development, and the basic approach is presented. The planned implementation of the diagnostics is discussed.

Domonkos, Matthew T.↗

Application of Laser Induced Fluorescence for flow diagnostics in arc jets

Laser Induced Fluorescence (LIF) studies are carried out on copper atoms, nitric oxide and oxygen molecules in the arc jet flows at the NASA Johnson Space Center Reentry Simulation Testing Facility. Measurements are taken in the free stream and from a blunt body shock layer. Tests are performed under different flow conditions to determine the feasibility and sensitivity of the LIF technique for various species. The LIF technique is developed as a part of high enthalpy flow diagnostics and will be useful to elucidate the rotational and vibrational temperatures. Adequate sensitivity for the detection of O2 and NO is demonstrated. Preliminary experiments for temperature and velocity measurements using copper as a tracer material are shown to be a useful new application of the laser resonant Doppler scattering technique.

Arepalli, Sivaram↗

Development of UV Optical Measurements of Nitric Oxide and Hydroxyl Radical at the Exit of High Pressure Gas Turbine Combustors

Measurements of nitric oxide (NO) and hydroxyl radical (OR) have been made in a laboratory flat flame at pressures up to 30 atm using line-of-sight resonant absorption. Data are reported at equivalence ratios of 0.98 and 1.3 and pressures of 1, 5, 10, 20 and 30 atm. The performance of the in-situ LTV absorption technique with assessed at these elevated pressures by comparing the measured absorption with those predicted by detailed theoretical spectroscopic models for NO and OH. Previous to this experiment the resonant models had not been verified at pressures greater than two atmospheres. Agreement within 25% was found between the measurements and predictions with only slight modification of the existing models for both NO and OH to account for line center shifting and pressure broadening. Continuum interference of hot oxygen (O2) on the NO absorption spectra was not significant in the interpretation of the data. The optical methods used in this study are distinct from laser-based diagnostics such as laser induced fluorescence and, hence, have the potential to provide independent verification of the laser-based measurements. The methodology is also of sufficient simplicity to be hardened into a portable optical measurement system that can be deployed in gas turbine engine test cells. A miniature fiber optic couple portable instrument is described.

Liscinsky, D. S.↗

Flow diagnostics of an arcjet using laser-induced fluorescence

A diagnostic has been developed to measure velocity and translational temperature in the plume of an arcjet thruster. Laser induced fluorescence with a narrowband CW laser is used to probe the Balmer alpha transition of excited atomic hydrogen. The velocity is determined from the Doppler shift of the fluorescence excitation spectrum while temperature is inferred from its shape. Analysis shows that while Doppler broadening is the only significant broadening mechanism, the fine structure of the transition must be accounted for. Near the exit plane, axial velocities vary from 4 to 14 km/s; radial velocities vary from 0 to 4 km/s; and swirl velocities are shown to be relatively small. Temperatures from 1000 to 5000 K indicate high dissociation fractions.

Liebeskind, John G.↗

Application of Raman diagnostics to combustion

The use of laser Raman diagnostic techniques to measure the specie concentrations and their temperatures in combustion flow fields is discussed. The system designed to measure the specie concentrations, which included a ruby laser and a photodiode to trip the laser at the maximum light and heat output of the combustion process, is described and problems encountered in developing the system are reported. Photographs of the combustion process are presented and analyzed detailing the evolution of the combustion in terms of the photodiode and the lack of a noticeable Raman-Stokes signal. The absence of the Raman-Stokes signal is discussed.

Lederman, S.↗

Fuel spray diagnostics

Several laser measurement methods are being studied to provide the capability to make droplet size and velocity measurements under a variety of spray conditions. The droplet sizing interferometer (DSI) promises to be a successful technique because of its capability for rapid data acquisition, compilation and analysis. Its main advantage is the ability to obtain size and velocity measurements in air-fuel mixing studies and hot flows. The existing DSI at NASA Lewis is a two-color, two-component system. Two independent orthogonal measurements of size and velocity components can be made simultaneously. It also uses an off-axis large-angle light scatter detection. The fundamental features of the system are optics, signal processing and data management system. The major component includes a transmitter unit, two receiver units, two signal processors, two data management systems, two Bragg cell systems, two printer/plotters, a laser, power supply and color monitor.

Bosque, M. A.↗

Virtual Diagnostics Interface (ViDI) for Planning Laser-Based Wind Tunnel Experiments

Virtual Diagnostics Interface (ViDI), originally introduced by Richard Schwartz in 2004 and described again by Alderfer, et. al., in 2007, is an interactive 3D software tool developed at NASA Langley Research Center to serve three main purposes: assist in pre-test planning, enhance post-test image analysis and visualization, and serve as a central location for data storage and distribution.1,2 ViDI is composed of custom-developed software and Autodesk® 3ds Max® as it incorporates Computer Aided Design (CAD) models with the results obtained from optical diagnostics.3 This software tool has proven useful in the field of optical diagnostics where pre-test planning of beam paths, optical elements, and test articles must be carried out to avoid interference, ensure spatial resolution is sufficient, and the camera Field of View (FoV) is adequate for the field of interest. Typically, practical considerations such as the distance a camera is from the region of interest, the angles at which the camera is oriented and issues such as the size of the camera and its sensor and size and focal length lens as well as the path of the laser need to be taken into account to predict a successful measurement. An example application of ViDI is shown in Fig.1 where an experiment to investigate flow separation over the wing of the High Lift Common Research Model (HL-CRM) is currently being planned in the National Transonic Facility (NTF) at NASA Langley Research Center.

virtual diagnostics interface↗

Laser Rayleigh and Raman Diagnostics for Small Hydrogen/oxygen Rockets

Localized velocity, temperature, and species concentration measurements in rocket flow fields are needed to evaluate predictive computational fluid dynamics (CFD) codes and identify causes of poor rocket performance. Velocity, temperature, and total number density information have been successfully extracted from spectrally resolved Rayleigh scattering in the plume of small hydrogen/oxygen rockets. Light from a narrow band laser is scattered from the moving molecules with a Doppler shifted frequency. Two components of the velocity can be extracted by observing the scattered light from two directions. Thermal broadening of the scattered light provides a measure of the temperature, while the integrated scattering intensity is proportional to the number density. Spontaneous Raman scattering has been used to measure temperature and species concentration in similar plumes. Light from a dye laser is scattered by molecules in the rocket plume. Raman spectra scattered from major species are resolved by observing the inelastically scattered light with linear array mounted to a spectrometer. Temperature and oxygen concentrations have been extracted by fitting a model function to the measured Raman spectrum. Results of measurements on small rockets mounted inside a high altitude chamber using both diagnostic techniques are reported.

Degroot, Wilhelmus A.↗

The Effects of Rapid Heating of Soot: Implications When Using Laser-Induced Incandescence for Soot Diagnostics

Recent experimental efforts have exploited the high temporal and spatial resolution of laser-induced incandescence (LII) as both a qualitative and quantitative measure of soot volume fraction. As a relatively new diagnostic technique, issues remain as to appropriate excitation laser intensities and the poential intrusive characteristics of LII. The high temperatures to which the soot is heated may accelerate heterogeneous reactions between the soot and flame gases. Vaporization of soot by high energy pulsed laser light has been theoretically modelled and experimentally observed. Potential physical and/or chemical changes in the laser-heated soot raises the question of how the LII signal depends upon these changes as well as the inferred soot volume fraction. Thus we investigated the effects of high energy pulsed laser light on the soot particles.

Vanderwal, Randy L.↗