Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

An overview of DREV's activities on pulsed CO2 laser transmitters: Frequency stability and lifetime aspects

After introducing the desired features in a transmitter for laser radar applications, the output characteristics of several configurations of frequency-stable TEA-CO2 lasers are reviewed. Based on work carried out at the Defence Research Establishment Valcartier (DREV), output pulses are examined from short cavity lasers, CW-TEA hybrid lasers, and amplifiers for low power pulses. It is concluded that the technique of injecting a low-power laser beam into a TEA laser resonator with Gaussian reflectivity mirrors should be investigated because it appears well adapted to producing high energy, single mode, low chirp pulses. Finally, a brief report on tests carried out on catalysts composed of stannic oxide and noble metals demonstrates the potential of these catalysts, operating at close to room temperature, to provide complete closed-cycle laser operation.

Cruickshank, James↗

Generating Submillimeter-Wave Frequencies From Laser Pulses

Semiconductor photoconductive switches generate electrical pulses containing submillimeter-wavelength carrier signals (frequency between 300 and 3,000 GHz) and harmonics thereof when illuminated with short-rise-time pulses from lasers. Device of this type used as local oscilator in heterodyne submillimeter-wave receiver. Electrical output of device coupled via transmission line, waveguide, or antenna to mixer circuitry of receiver. Phase delays between optically activated semiconductor switches determine output carrier frequencies. N electrical pulses generated by each laser pulse. Thus, fundamental output frequency is N times laser-pulse-repetition rate.

Spencer, Michael G.↗

Collisionless dissociation of SF6 using two resonant frequency CO2 laser fields

The collisionless dissociation of SF6 has been studied using simultaneous irradiation by two frequencies from a CO2 laser which are both nearly resonant with the SF6nu3 absorption band. It was found that the dissociation was enhanced, and occurred over a wider frequency range, than for single frequency dissociation. No threshold effect was observed for a weak resonant and a much higher energy field pumping slightly off-resonance. For such two frequency irradiation, the peak in the dissociation curve was found to be shifted to lower frequencies with respect to that for single frequency dissociation.

Gower, M. C.↗

Single Frequency, Pulsed Laser Diode Transmitter for Dial Water Vapor Measurements at 935nm

We report a tunable, single frequency, narrow linewidth, pulsed laser diode transmitter at 935.68nm for remote sensing of atmospheric water vapor. The transmitter consists of a CW, tunable, external cavity diode laser whose output is amplified 2OdB using a tapered diode amplifier. The output is pulsed for range resolved DIAL lidar by pulsing the drive current to the diode amplifier at 4kHz with a .5% duty cycle. The output from the transmitter is 36OnJ/pulse and is single spatial mode. It maintains a linewidth of less than 25MHz as its wavelength is tuned across the water vapor absorption line at 935.68nm. The transmitter design and its use in a water vapor measurement will be discussed.

Switzer, Gregg W.↗

Absolute frequency stabilization of laser oscillator against laser amplifier

Long-term absolute frequency stabilization of a laser oscillator is obtained when the lasers oscillation frequency is referenced to the exact center of an atomic transition. A laser amplifier acts as a discriminant to indicate when the laser frequency deviates from the center of its atomic transistion.

Siegman, A. E.↗

Semiconductor Laser Tracking Frequency Distance Gauge

Advanced astronomical missions with greatly enhanced resolution and physics missions of unprecedented accuracy will require a spaceworthy laser distance gauge of substantially improved performance. The Tracking Frequency Gauge (TFG) uses a single beam, locking a laser to the measurement interferometer. We have demonstrated this technique with pm (10(exp -12) m) performance. We report on the version we are now developing based on space-qualifiable, fiber-coupled distributed-feedback semiconductor lasers.

Phillips, James D.↗

Frequency domain laser velocimeter signal processor

A laser velocimeter signal processor for measuring the signal frequency within a signal burst. The input signal is converted to digital by an ADC 16 and then shifted into shift registers 30 and 31. An automatic gain circuit 15 controls the gain of the input signal. A signal integration circuit 32 determines when a signal burst has been captured by the shift registers and then transfers the contents of the registers to data latches 33 and 34. The data in data latches 33 and 34 is processed by digital bandpass filters 57-63, square law detectors 64-70, burst counters 71-77 and signal processor 78 to determine the frequency of the signal within the captured signal burst.

James F Meyers↗

Optimization of microscopic and macroscopic second order optical nonlinearities

Nonlinear optical materials (NLO) can be used to extend the useful frequency range of lasers. Frequency generation is important for laser-based remote sensing and optical data storage. Another NLO effect, the electro-optic effect, can be used to modulate the amplitude, phase, or polarization state of an optical beam. Applications of this effect in telecommunications and in integrated optics include the impression of information on an optical carrier signal or routing of optical signals between fiber optic channels. In order to utilize these effects most effectively, it is necessary to synthesize materials which respond to applied fields very efficiently. In this talk, it will be shown how the development of a fundamental understanding of the science of nonlinear optics can lead to a rational approach to organic molecules and materials with optimized properties. In some cases, figures of merit for newly developed materials are more than an order of magnitude higher than those of currently employed materials. Some of these materials are being examined for phased-array radar and other electro-optic switching applications.

Marder, Seth R.↗

The role of laser coherence in long-range vibration measurements

In this paper, the temporal coherence effect of a laser oscillator will be critically examined using existing laser frequency stability data in the time domain by first converting them to the frequency domain. We limit our discussion to CO2 lasers. To be more specific, our presentation will include the following items: (1) a review of the definitions and representations of laser oscillator frequency stability; (2) a methodology will be developed for determining the dynamic range of vibration measurements; (3) the methodology will show that the conversion of the laser frequency stability from the time domain to the frequency domain can be performed effectively in the optical region; and (4) because of a finite time delay, the phase noise is reduced for offset frequencies close to the carrier frequency.

Eng, R. S.↗

Arm Locking for the Laser Interferometer Space Antenna

The Laser Interferometer Space Antenna (LISA) mission is a planned gravitational wave detector consisting of three spacecraft in heliocentric orbit. Laser interferometry is used to measure distance fluctuations between test masses aboard each spacecraft to the picometer level over a 5 million kilometer separation. Laser frequency fluctuations must be suppressed in order to meet the measurement requirements. Arm-locking, a technique that uses the constellation of spacecraft as a frequency reference, is a proposed method for stabilizing the laser frequency. We consider the problem of arm-locking using classical optimal control theory and find that our designs satisfy the LISA requirements.

Maghami, P. G.↗

Two-frequency laser-induced fluorescence technique for rapid velocity-field measurements in gas flows

A technique is presented for measurements of two-dimensional velocity fields in gas flows. The single-mode frequency of an argon-ion laser is fixed in the wing of an absorption line of iodine molecules that are seeded at low level in the flow of interest. The emitted fluorescence is detected with an image-intensified 100 x 100 photodiode-array camera. two pairs of counterpropagating laser sheets sequentially probe the flow to determine two velocity components. The frequency in one pair is shifted with respect to the other by an acousto-optic modulator. This two-frequency scheme eliminates the need to determine the slope of the line externally and offers the potential for combined pressure and velocity-field measurements.

Hiller, B.↗

Frequency Analyzed Laser Light Scattering (Falls)

A simple and robust light scattering technique for spray diagnostics was developed. The technique provides a spray's intact length and breakup frequency. Scattered light is collected from a laser sheet that illuminates a portion of the spray. The scattered light is imaged on a fast photodiode whose output is sampled at 20 kHz. Fast Fourier transform (FFT) analysis is performed on the sampled signal. The shape of the FFT produced can be correlated to one of three distinct spray regimes: intact sheet, ligaments, or droplets. Strobe and laser illuminated photographs are also shown for reference.

Rhys, Noah O.↗

The development of a tunable, single-frequency ultraviolet laser source for UV filtered Rayleigh scattering

We present the development of a flexible, high power, narrow line width, tunable ultraviolet source for diagnostic application. By frequency tripling the output of a pulsed titanium-sapphire laser, we achieve broadly tunable (227-360 nm) ultraviolet light with high quality spatial and spectral resolution. We also present the characterization of a mercury vapor cell which provides a narrow band, sharp edge absorption filter at 253.7 nm. These two components form the basis for the extension of the Filtered Rayleigh Scattering technique into the ultraviolet. The UV-FRS system is comprised of four pieces: a single frequency, cw tunable Ti:Sapphire seeding source; a high-powered pulsed Ti:Sapphire oscillator; a third harmonic generator system; and an atomic mercury vapor filter. In this paper we discuss the development and characterization of each of these elements.

Finkelstein, N.↗

Semiconductor Laser Low Frequency Noise Characterization

This work summarizes the efforts in identifying the fundamental noise limit in semiconductor optical sources (lasers) to determine the source of 1/F noise and it's associated behavior. In addition, the study also addresses the effects of this 1/F noise on RF phased arrays. The study showed that the 1/F noise in semiconductor lasers has an ultimate physical limit based upon similar factors to fundamental noise generated in other semiconductor and solid state devices. The study also showed that both additive and multiplicative noise can be a significant detriment to the performance of RF phased arrays especially in regard to very low sidelobe performance and ultimate beam steering accuracy. The final result is that a noise power related term must be included in a complete analysis of the noise spectrum of any semiconductor device including semiconductor lasers.

SEMICONDUCTOR LASERS↗

Time Shifted PN Codes for CW Lidar, Radar, and Sonar

A continuous wave Light Detection and Ranging (CW LiDAR) system utilizes two or more laser frequencies and time or range shifted pseudorandom noise (PN) codes to discriminate between the laser frequencies. The performance of these codes can be improved by subtracting out the bias before processing. The CW LiDAR system may be mounted to an artificial satellite orbiting the earth, and the relative strength of the return signal for each frequency can be utilized to determine the concentration of selected gases or other substances in the atmosphere.

Campbell, Joel F.↗

Modulated Sine Waves for Differential Absorption Measurements Using a CW Laser System

A continuous wave Light Detection and Ranging (CW LiDAR) system utilizes two or more laser frequencies and time or range shifted pseudorandom noise (PN) codes to discriminate between the laser frequencies. The performance of these codes can be improved by subtracting out the bias before processing. The CW LiDAR system may be mounted to an artificial satellite orbiting the earth, and the relative strength of the return signal for each frequency can be utilized to determine the concentration of selected gases or other substances in the atmosphere.

Campbell, Joel F.↗

System and Method for Generating a Frequency Modulated Linear Laser Waveform

A system for generating a frequency modulated linear laser waveform includes a single frequency laser generator to produce a laser output signal. An electro-optical modulator modulates the frequency of the laser output signal to define a linear triangular waveform. An optical circulator passes the linear triangular waveform to a band-pass optical filter to filter out harmonic frequencies created in the waveform during modulation of the laser output signal, to define a pure filtered modulated waveform having a very narrow bandwidth. The optical circulator receives the pure filtered modulated laser waveform and transmits the modulated laser waveform to a target.

Pierrottet, Diego F.↗