Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser induced plasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

NO PLIF flow visualization and time-resolved temperature distributions in laser induced breakdown plumes

NO planar laser induced fluorescence (PLIF) is used to obtain images of laser-induced breakdown plasma plumes in NO-seeded nitrogen and dry air at near atmospheric pressure. Single-shot PLIF-images show that the plume development 5–50 μs after the breakdown pulse is fairly reproducible shot-to-shot, although the plume becomes increasingly stochastic on longer timescales, 100–500 μs. The stochastic behavior of the plume is quantified using probability distributions of the loci of the plume boundary. Analysis of the single-shot images indicates that the mixing of the plume with ambient gas on sub-ms time scale is insignificant. The induced flow velocity in the plume is fairly low, up to 30 m s –1 , suggesting that laser breakdowns are ineffective for mixing enhancement in high speed flows. The ensemble-averaged PLIF images indicate the evolution of the plume from an initially elongated shape to near-spherical to toroidal shape, with a subsequent radial expansion and formation of an axial jet in the center. Temperature distributions in the plume in air are obtained from the NO PLIF images, using two rotational transitions in the NO(X, v' = 0 → A, v'' = 0) band, J'' = 6.5 and 12.5 of the Q R 12 + Q 2 branch. The results indicate that the temperature in the plume remains high, above 1000 K, for approximately 100 μs, after which it decays gradually, to below 500 K at 500 μs. The residual NO fraction in the plume is ~0.1%, indicating that repetitive laser-assisted ignition may result in significant NO-generation. Furthermore, these measured temperature and velocity distributions can be used for detailed validation of kinetic models of laser-induced breakdown and assessment of their predictive capability.

42 ENGINEERING↗

Planar laser induced fluorescence mapping of a carbon laser produced plasma

We present measurements of ion velocity distribution profiles obtained by laser induced fluorescence (LIF) on an explosive laser produced plasma. The spatiotemporal evolution of the resulting carbon ion velocity distribution was mapped by scanning through the Doppler-shifted absorption wavelengths using a tunable, diode-pumped laser. The acquisition of these data was facilitated by the high repetition rate capability of the ablation laser (1 Hz), which allowed for the accumulation of thousands of laser shots in short experimental times. By varying the intensity of the LIF beam, we were able to explore the effects of fluorescence power against the laser irradiance in the context of evaluating the saturation vs the non-saturation regime. The small size of the LIF beam led to high spatial resolution of the measurement compared to other ion velocity distribution measurement techniques, while the fast-gate operation mode of the camera detector enabled the measurement of the relevant electron transitions.

Instruments & Instrumentation↗

Computer modeling of pulsed CO2 lasers for lidar applications

The experimental results will enable a comparison of the numerical code output with experimental data. This will ensure verification of the validity of the code. The measurements were made on a modified commercial CO2 laser. Results are listed as following. (1) The pulse shape and energy dependence on gas pressure were measured. (2) The intrapulse frequency chirp due to plasma and laser induced medium perturbation effects were determined. A simple numerical model showed quantitative agreement with these measurements. The pulse to pulse frequency stability was also determined. (3) The dependence was measured of the laser transverse mode stability on cavity length. A simple analysis of this dependence in terms of changes to the equivalent fresnel number and the cavity magnification was performed. (4) An analysis was made of the discharge pulse shape which enabled the low efficiency of the laser to be explained in terms of poor coupling of the electrical energy into the vibrational levels. And (5) the existing laser resonator code was changed to allow it to run on the Cray XMP under the new operating system.

Spiers, Gary D.↗

Spectro-temporal comparisons of optical emission, absorption, and laser-induced fluorescence for characterizing ns and fs laser-produced plasmas

We performed simultaneous measurement of absorption, emission, and laser-induced fluorescence spectroscopic signatures for determining nanosecond and femtosecond laser-produced plasma’s physical properties throughout its lifecycle. Plasmas are produced by focusing either ~6 ns, 1064 nm pulses from an Nd:YAG or ~35 fs, ~800 nm pulses from a Ti:Sapphire laser on an Inconel target that contains Al as a minor alloying addition. A continuous-wave narrowband tunable laser was used for performing absorption and fluorescence spectroscopy while a fast-gated detection system was used for emission spectroscopy. The temporal evolution of emission, fluorescence, and absorbance of Al transitions are compared for both ns and fs laser-produced plasms. Time-resolved absorbance was also used for evaluating linewidth, lineshape, temperature, and column-averaged atomic number density at late times of ns and fs plasma evolution. Our results demonstrate that lower and excited-state populations of fs laser produced plasmas are short-lived in comparison to those in ns plasmas. The lower state population is observed to reach a maximum value earlier in time for the fs plasma versus the ns plasma, while the kinetic temperature for the ns plasma was higher than for the fs plasma at most times of the plasma evolution.

(280.4788) Optical Sensing, (300.2140) Emission Sp↗

Radiative transition probabilities of neutral and singly ionized Europium estimated by laser-induced breakdown spectroscopy (LIBS)

Laser-induced breakdown spectroscopy (LIBS) is a versatile technique for compositional analysis for solids, liquids, or gasses. LIBS is an asset for the quantitative or qualitative analysis of resource limited materials like actinides and rare earths because it is quasi-nondestructive. Two Eu 2 O 3 pellets were synthesized to be a test and validation set, respectively. Spectral lines identified from the National Institute of Standards and Technology database with fundamental data reported were used to form Saha-Boltzmann plots. The Saha-Boltzmann plots were used to determine the plasma temperatures and electron densities of the laser-induced plasmas for both samples. These Saha-Boltzmann plots were then used to calculate previously unreported transition probabilities associated with identified peaks. Additionally, the transition probabilities presented in this paper provide the capability for calibration free LIBS to be performed more readily on europium samples and the spectroscopic analysis of stellar bodies. Eight previously unreported transition probabilities are presented in this paper; five for Eu I and three for Eu II. The transition probabilities for Eu I ranged from 0.172 to 7.38 × 10 7 s -1 and those for Eu II ranged from 1.56 to 6.75 × 10 7 s -1 .

47 OTHER INSTRUMENTATION↗

Laser-induced-fluorescence imaging of a spin-polarized ultracold neutral plasma in a magnetic field

In this work, we report Doppler-sensitive laser-induced-fluorescence (LIF) imaging of an ultracold neutral plasma in a magnetic field. Local values of ion density, hydrodynamic fluid velocity, temperature, and spin polarization are obtained using a fluorescence model based on velocity-resolved rate equations (REs) including the transfer of ions between states due to laser coupling and spontaneous emission. The RE approach captures optical pumping of ions into states that are not driven by the LIF excitation laser, and this is validated with experimental data. Combined molecular-dynamics and quantum-trajectories simulations verify that velocity-changing collisions have a negligible impact on the state population evolution for typical experimental conditions. Relative intensities of Zeeman components of the LIF spectra provide clear evidence that the ions are electron-spin-polarized when created by photoionization of magnetically trapped 88 Sr atoms. This probe opens many possibilities for studying thermal transport and the equilibration of neutral plasmas in overlapping regimes of strong coupling and magnetization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical Evidence of Compositional Fractioning between Plasma‐Condensed and Melt Pool Matter

Control of multicomponent alloys during welding is challenging because it lacks a real‐time understanding of composition. The optical emissions of plasma formed during laser‐induced metal welding correlate with the composition of particles ejected from the melt pool. Plasma emissions observed in this study contain large iron, manganese, chrome, and copper signatures, which match the composition of emitted particles. Particles recovered closest to the melt pool exhibit a core–shell morphology that is composed of iron‐manganese‐chrome intermetallic cores within copper shells. Particles collected farther from the melt pool, do not share this core–shell morphology, though similar elemental compositions are observed. The correlation between plasma optical emissions and particle composition can be used to predict the composition of the melt pool, allowing for real‐time welding and sintering control.

36 MATERIALS SCIENCE↗

Solid-to-plasma transition of polystyrene induced by a nanosecond laser pulse within the context of inertial confinement fusion

Laser Direct Drive (LDD) Inertial Confinement Fusion (ICF) involves irradiating a spherical target of thermonuclear fuel coated with an ablator, usually made of polystyrene. Laser energy absorption near the target surface leads to matter ablation, hydrodynamic shocks, and ultimately capsule implosion. The conservation of spherical symmetry is crucial for implosion efficiency, yet spatial modulations in laser intensity can induce nonuniformities, causing the laser imprint phenomenon. Understanding laser imprint, especially considering the initial solid state, is essential for advancing LDD ICF. A first microscopic model of solid-to-plasma transition was built in 2019, accounting for laser absorption in the solid state with a band structure based ionization model. This model has been improved to include chemical fragmentation and a more accurate description of electron collision frequency in various matter states. The latest development involves assessing the model reliability by comparing theoretical predictions with experimental observations. Despite the success of this approach, questions remain, leading to further investigations and observations under different irradiation conditions. This work presents an experiment with a nanosecond pulse, taking into account hydrodynamic effects, and measures transmission dynamics over the entire laser beam area to observe two-dimensional effects. As a result, the objective is to adapt the theoretical model, couple it with a hydrodynamic code, and observe additional effects related to the initial solid state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic deuterium retention properties of tungsten measured using laser-induced breakdown spectroscopy

Dynamic deuterium (D) retention properties of tungsten (W) are investigated under steady-state D plasma exposure in the PISCES-A linear plasma device. In contrast to static retention, dynamic retention is quickly released from the material at the termination of the incident plasma flux, and thus in-operando laser-induced breakdown spectroscopy (LIBS) measurements have been conducted during steady-state D plasma exposure. A procedure is, first, established to extract the dynamic retention component from the in-operando LIBS D I 656.1 nm line intensity, which can contain contributions from dynamic and static retention as well as background D/D 2 gas, excited by both steady-state and laser-induced plasmas. Using the developed procedure, the dynamic D retention in W is systematically examined while scanning the following plasma exposure parameters: incident ion energy, E i , sample temperature, T s , incident ion flux, Γ i . No clear E i dependence is seen in the range of E i ~ 45–175 eV, as expected from a small variation in the average implantation depth (~3-6 nm) of D in W. The dynamic retention is found to monotonously decrease with increasing T s from 348 to 573 K, while the total static retention is reported to peak at T s ~ 500–600 K. It is revealed that the dynamic retention linearly increases with increasing Γ i , and then saturates at Γ i ≥ 0.75 × 10 21 m –2 s –1 . Possible physical mechanisms for the observed dependence of the dynamic retention on T s and Γ i are discussed. Furthermore, sequential pure He, followed by pure D, plasma exposures show that the dynamic D retention is not strongly affected by He bubbles in the near-surface region.

super-saturated surface layer↗

Real-time monitoring of trace noble gases using laser-induced breakdown spectroscopy—An investigation of the impact of bulk gas on plasma properties and sensitivity

The impact of Ar and He bulk gases on laser-induced breakdown spectroscopy (LIBS) real-time monitoring of trace Xe and Kr was assessed. LIBS is being developed as a monitoring tool for measuring noble gas transport in molten salt systems, in which traditional sensors may face challenges associated with radiation, corrosive materials, and/or mixed phases. The plasma temperature and electron densities of LIBS plasmas were measured in both static and various flowing Ar and He streams (0–5 L min −1 ). The use of an Ar bulk gas resulted in higher plasma temperature, greater electron densities by an order of magnitude, and extended plasma lifetime compared with when He bulk gas was used. Gas flow rate was found to have little impact on plasma temperature; however, its effect on electron density was significant, indicating the need to consider flow rate–specific models. Matrix effects on emission peaks were reported for both bulk gases. Due to these matrix effects, multivariate models were developed for Xe and Kr ranging from 0 to 700 ppm in both bulk gases. Although the predictive behavior was similar (root mean square error of prediction ranging from 11.1 to 20.6 ppm), the limits of detection were superior in He (Xe: 22.9 ppm, Kr: 30.4 ppm). Furthermore, these models were employed in demonstrative real-time tests (>1 h), which showed strong predictive precision (relative standard deviation <5 %) regardless of the bulk gas. Ultimately, this study provides a guide for the considerations required when developing gaseous LIBS models for real-time monitoring.

Gas flow effects↗

Creation of large temperature anisotropies in a laboratory plasma

Ion temperature anisotropy in an expanding magnetized plasma is investigated using laser induced fluorescence. Parallel and perpendicular ion velocity distribution functions (IVDFs) were measured simultaneously with high spatial resolution in the expanding plasma. Large ion temperature anisotropies (T ⊥i /T ∥i ~ 10) are observed in a conical region at the periphery of the expanding plasma plume. A simple 2D Boris stepper model that incorporates the measured electric field structure is able to reproduce the gross features of the measured perpendicular IVDFs. Here, a Nyquist stability analysis of the measured IVDFs suggests that multiple instabilities with k ⊥ρi ~ 1 and k ||ρi ~ 0.2 are likely to be excited in these plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proton radiography inversions with source extraction and comparison to mesh methods

In this article, proton radiography is a central diagnostic technique for measuring electromagnetic (EM) fields in high-energy-density, laser-produced plasmas. In this technique, protons traverse the plasma where they accumulate small EM deflections which lead to variations in the proton fluence pattern on a detector. Path-integrated EM fields can then be extracted from the fluence image through an inversion process. In this work, experiments of laser-driven foils were conducted on the OMEGA laser and magnetic field reconstructions were performed using both “fluence-based” techniques and high-fidelity “mesh-based” methods. We implement nonzero boundary conditions into the inversion and show their importance by comparing against mesh measurements. Good agreement between the methods is found only when nonzero boundary conditions are used. We also introduce an approach to determine the unperturbed proton source profile, which is a required input in fluence reconstruction algorithms. In this approach, a fluence inversion is embedded inside of a mesh region, which provides overconstrained magnetic boundary conditions. A source profile is then iteratively optimized to satisfy the boundary information. This method substantially enhances the accuracy in recovering EM fields. Lastly, we propose a scheme to quantify uncertainty in the final inversion that is introduced through errors in the source retrieval.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗