Using neutrons and x rays to measure plasma conditions in a solid sphere of deuterated polyethylene compressed to densities of 35 g/cc at temperatures of 2 keV and pressures of 40 Gbar

This paper describes an experiment that shock compresses the center of a solid deuterated polyethylene sphere, CD 2 , to densities of 35 g/cc and temperatures of 2 keV with corresponding pressure of 40 Gbar. The design employs a strong spherically converging shock launched through a solid ball of material using a Hohlraum radiation drive. As the shock coalesces at the center it produces a hot spot that we characterize by measuring the x-ray self-emission and 2.45 MeV neutrons emitted. Two-dimensional images and time-resolved measurements of the x rays emitted determine the size and time duration of the hot spot, leading to an estimated 2k eV electron temperature. The neutron time of flight spectrometer measures an average ion temperature of 1.06 ± 0.15 keV and neutron yield of 7.0 (±0.5) × 10 9 DD neutrons. Our new distribution function tool enables us to create a forward model of the experimental data based on 1D radiation-hydrodynamic simulations, leading to a better understanding of the plasma conditions that produce the measured neutrons and x rays. Furthermore, our simulations indicate that the x rays are produced in a short-lived hot-dense core over tens of picoseconds, whereas the neutron emission continues for about 200 ps, as the hot core starts to expand, thereby leading to a lower mean temperature of the plasma during neutron production. This finding is in agreement with the experimental data, and we therefore conclude that the forward-modeling is a useful tool for inferring the conditions of the hot spot in a laser-driven implosion during burn.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray phase-contrast imaging of strong shocks on OMEGA EP

The ongoing improvement in laser technology and target fabrication is opening new possibilities for diagnostic development. An example is x-ray phase-contrast imaging (XPCI), which serves as an advanced x-ray imaging diagnostic in laser-driven experiments. In this work, we present the results of the XPCI platform that was developed at the OMEGA EP Laser-Facility to study multi-Mbar single and double shocks produced using a kilojoule laser driver. Two-dimensional radiation-hydrodynamic simulations agree well with the shock progression and the spherical curvature of the shock fronts. It is demonstrated that XPCI is an excellent method to determine with high accuracy the front position of a trailing shock wave propagating through an expanding CH plasma that was heated by a precursor Mbar shock wave. Furthermore, the interaction between the rarefaction wave and the shock wave results in a clear signature in the radiograph that is well reproduced by radiation-hydrodynamic simulations.

47 OTHER INSTRUMENTATION↗

Source size of x rays from self-modulated laser wakefield accelerators

A comparative study of x-ray sources generated with different mechanisms from self-modulated laser wakefield acceleration (SM-LWFA) electrons was performed to compare the source size or spatial resolution for use in high energy density science applications. We examine the source size of betatron, inverse Compton scattering, and bremsstrahlung radiation with a Fresnel diffraction based formalism and a modified x-ray ray tracing model. We observe the dependence of source size on the radiation generation process, laser parameters, and compare to what is possible in other regimes of LWFA, as well as current methods. This information is significant as we begin to explore the use of light sources driven by SM-LWFA for use as a diagnostic at large-scale laser facilities where blowout regime LWFA is not possible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing turbulence with lasers and coherent light sources

Fluid and plasma turbulence consists of multi-scale interactions where the energy of the large scales is dissipated through a cascade to the smallest scales set by the microphysics. Turbulence and mixing can be detrimental to system performance, such as in inertial confinement fusion (ICF). Our current understanding of turbulence is mostly derived from studies of incompressible flows, where the intermediate-scaled eddies in the “inertial range” bridge the transfer of energy from the large eddies to the dissipative range, and that there is no communication between eddies of disparate scales. Whether a similar cascade process exists for compressible turbulence, however, remains to be seen; experiments have been limited by diagnostics and supersonic flow facilities. This project has focused on the development of techniques to measure the evolution of flows and microphysical transport properties using particle tracking velocimetry. This project has investigated three main areas: (1) particle-tracking experiments with x-ray radiography, (2) shock-particle interactions, (3) quantifying viscous effects on particles in shocked flows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of a mock up nuclear waste package using energy resolved MeV neutron analysis

Reliable radiographic methods for characterizing nuclear waste packages non-destructively (without the need to open containers) have the potential to significantly contribute to safe handling and future disposal options, particularly for legacy waste of unknown content. Due to required shielding of waste containers and the need to characterize materials consisting of light elements, X-ray methods are not suitable. Here, energy-resolved MeV neutron radiography is demonstrated as a first-of-its-kind application for non-destructive and remote examination of mock up nuclear waste packages from a safe position using time-of-flight techniques enabled by a novel event-mode imaging detector system. Energy-resolved neutron transmission spectra were measured spatially, permitting the detection of analogue materials to actual nuclear waste such as water, melamine, and ion exchange resin within a 2.54 cm wall thickness steel pipe. The results demonstrate the capability to locate the materials through this wall thickness by radiography and tomographic reconstruction, revealing detailed 3D distributions and structural anomalies. The method effectively detects residual water in ion exchange resin, highlighting its sensitivity to moisture content, a crucial parameter for nuclear waste characterization. Monte Carlo simulations are in agreement with the experimental findings, providing a pathway to simulate waste forms more difficult to tackle experimentally. This work paves the way to apply sub-nanosecond intense MeV neutron sources, such as laser-driven neutron sources under development, to nuclear waste characterization.

36 MATERIALS SCIENCE↗

Analytical model for balling defects in laser melting using rivulet theory and solidification

In laser welding and additive manufacturing communities, the balling (humping) defect is primarily attributed to the Plateau–Rayleigh fluid instability (PRI) with a few authors suggesting fluid jetting and volume conservation as alternative mechanisms. As analytical descriptions of these mechanisms are unavailable, combining them into a single formalism is unfeasible. We present a new model of PRI with higher accuracy, accounting for competition with solidification, to compare the expected behavior with known experimental trends when fluid jetting is neglected. We adapt a rivulet instability model from fluid physics to account for the stabilizing effects of the substrate, which the traditional cylindrical-jet geometry does not account for and estimate the instability growth rate. Our model yields a continuous transition from non-balling to balling hitherto lacking in current literature and predicts instability growth at higher wavelengths with strong sensitivity to the solidification front curvature. While the fluid surface is most unstable for shallow melt pools, the absolute magnitude of balling relevant to printing defects scales with melt pool depth and has a maximum for a given melt pool geometry. Synchrotron-based x-ray radiography of thin samples indicates that PRI growth rates and solidification can be comparable in magnitude and thus compete, as we find in this work. We predict that deviations between model predictions and our experimental results demonstrate the importance of fluid flows and heat transport in the balling process. Our experiments further demonstrate at least one mechanism by which the melt pool length and the balling wavelength are not equivalent, as commonly claimed.

Taylor, Z. [Stanford Univ., CA (United States); SL↗

The role of focusing geometry in MeV x-ray production from petawatt laser–solid interaction

Relativistic laser–plasma interactions provide a compact and flexible route to generating bright, ultrashort pulses of MeV x rays, with applications in high-energy density science, nuclear physics, and radiography. Despite extensive study of intensity scaling in laser-driven electron acceleration, the role of focusing geometry and focal-volume effects in MeV radiation production remains insufficiently understood. Here, we present experimental and kinetic simulation results from the Texas Petawatt Laser (120 J, 140 fs) in which the focusing geometry (f/3 or f/1.5) is varied, while the laser energy and pulse duration are fixed. Experimentally, the f/3 geometry produces approximately three times more MeV radiation than the f/1.5 geometry, despite its twofold lower nominal vacuum intensity. This result is based on the time-integrated radiation per unit solid angle, as measured along the diagnostic line of sight. Three-dimensional particle-in-cell simulations reproduce this trend when a modest (10s of μm) effective focal plane shift is introduced, demonstrating that relativistic laser–plasma coupling is highly sensitive to focal geometry in the presence of a preplasma. This behavior is consistent with differences in interaction length and effective intensity at the critical surface between the two configurations. The sensitivity of the tightly focused f/1.5 configuration ($z_R ≈$⁠ 5 μ m) reflects the combined influence of thermal lensing and an extended preplasma, while the f/3 geometry (⁠$z_R ≈$ 80 μ m) remains comparatively robust. These results demonstrate a breakdown of conventional intensity scaling and identify focusing geometry as a critical control parameter for MeV electron and x-ray generation at petawatt powers. Implications for laser–plasma-based radiographic facilities are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nondestructive Evaluation of Foam Insulation on the Space Shuttle External Tank

Foam loss on the External Tank (ET) during launch can be caused by a number of factors. Voids are the best understood mechanism of foam loss, although it is known that delaminations, cracks and crushed foam can also lead to liberation of foam. Shortly after the Columbia accident, work began on non-destructive evaluation of foam targeted at finding voids and delaminations. After several months of searching for candidate methods capable of inspecting ET foam, the five most promising techniques were taken through a blind test and narrowed down to two methods to develop and use for inspection of the ET. These methods were backscatter radiography and terahertz imaging. The backscatter radiography system measures a test part by detecting Compton backscattered x-ray energy generated by a collimated beam of x-rays directed at the test subject. This collimated beam is scanned across the subject, recording scatter intensity data one pixel at a time until the area of interest is covered. The resulting data can be used to generate an image similar to a radiograph. Some depth information can be gathered utilizing apertures or collimation on the detectors. The detectors are located around the collimated source, making this a single sided inspection. The void detection limit with the currently utilized system is around 0.5 inches in diameter by 0.2 inches high. The terahertz imaging system inspects a test part by utilizing a transceiver to emit a pulse focused at the aluminum skin of the ET, which reflects it back to the transceiver where it is analyzed. The transceiver is scanned across the area of interest until a measurement has been taken at every location. Amplitude, time delay and frequency content are examined to note any discontinuities which may be the result of a void or other type of defect. The pulse currently utilized is in the millimeter wave regime. The void detection limit with this system is around 0.5 inches in diameter by 0.2 inches high. With increased interest in other causes of foam loss following the flight of Discovery in July 2005, laser shearography was added to the techniques used for inspecting ET foam. The shearography method records a sheared image of a laser speckle pattern projected on a test part before And after some sort of excitation. The resultant fringe pattern allows the slope of the out of plane displacement to be measured. For crushed and delaminated foam applications, a non-contact air coupled acoustic force is used to excite the surface of the foam. Regions without defects tend to respond differently to the sound energy than do regions with defects, generating a map of the foam integrity. Foam crushed to a depth of about 0.1 inches is detectable with shearography even after it has relaxed to its original shape.

Richter, Joel↗

Advances in laser-based bremsstrahlung x-ray sources. I. Optimizing laser-accelerated electrons

In this work, we have performed a suite of kinetic simulations of relativistic laser–plasma interaction under settings relevant to recent and planned experiments on a variety of laser systems. The goal of the study is to illuminate the physics of laser–target coupling and to provide guidance for how to optimize these sources for applications. It is shown that the production of relativistic electrons is maximized when conditions of relativistic induced transparency (RIT) in dense plasmas can be achieved over a large interaction volume at the time of arrival of most intense part of the laser pulse. RIT is shown to enhance both the numbers of relativistic electrons and the energies of the electrons, leading to an increased x-ray dose. A variety of approaches to enhancing laser–target coupling are considered. These include optimizing the effects of low-density pre-plasma (arising either from finite laser pedestal or from the use of foam coatings) and of modifying the laser focusing geometry to reduce effects of filamentation and self-focusing. Evidence of a novel approach to achieving stable laser propagation over distances of tens of micrometers in a plasma gradient is also presented. These conditions coincide with plasma and laser conditions explored in recent experiments on the Omega EP laser system and compare favorably with an analytic criterion for stable laser propagation in relativistically underdense plasma obtained from a nonlinear Wentzel–Kramers–Brillouin analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

Platform for probing radiation transport properties of hydrogen at conditions found in the deep interiors of red dwarfs

We describe an experimental concept at the National Ignition Facility for specifically tailored spherical implosions to compress hydrogen to extreme densities (up to ∼800× solid density, electron number density ne∼4×1025 cm−3) at moderate temperatures (T∼200 eV), i.e., to conditions, which are relevant to the interiors of red dwarf stars. The dense plasma will be probed by laser-generated x-ray radiation of different photon energy to determine the plasma opacity due to collisional (free–free) absorption and Thomson scattering. The obtained results will benchmark radiation transport models, which in the case for free–free absorption show strong deviations at conditions relevant to red dwarfs. This very first experimental test of free–free opacity models at these extreme states will help to constrain where inside those celestial objects energy transport is dominated by radiation or convection. Moreover, our study will inform models for other important processes in dense plasmas, which are based on electron–ion collisions, e.g., stopping of swift ions or electron–ion temperature relaxation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A study of space charge induced non-linearity in the Single Line Of Sight camera

We report a new generation of gated x-ray detectors at the National Ignition Facility has brought faster, enhanced imaging capabilities. Their performance is currently limited by the amount of signal they can be operated with before space charge effects in their electron tube start to compromise their temporal and spatial response. We present a technique to characterize this phenomenon and apply it to a prototype of such systems, the Single Line Of Sight camera. Results of this characterization are used to benchmark Particle In Cell simulations of the electrons drifting inside the detector, which are found to well reproduce experimental data. These simulations are then employed to predict the optimum photon flux to the camera, with the goal to increase the quality of the images obtained on an experimental campaign while preventing the appearance of deleterious effects. They also offer some insight into some of the improvements that can be brought to the new pulse-dilation systems being built at Lawrence Livermore National Laboratory

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sinter formation during directed energy deposition of titanium alloy powders

During directed energy deposition (DED) additive manufacturing, powder agglomeration and sintering can occur outside of the melt pool when using titanium alloy powders. Using in situ synchrotron radiography we investigate the mechanisms by which sintering of Ti6242 powder occurs around the pool, performing a parametric study to determine the influence of laser power and stage traverse speed on sinter build-up. The results reveal that detrimental sinter can be reduced using a high laser power or increased stage traverse speed, although the latter also reduces deposition layer thickness. The mechanism of sinter formation during DED was determined to be in-flight heating of the powder particles in the laser beam. Calculations of particle heating under the processing conditions explored in this study confirm that powder particles can reasonably exceed 700 °C, the threshold for Ti surface oxide dissolution, and thus the powder is prone to sintering if not incorporated into the melt pool. The build-up of sinter powder layer on deposit surfaces led to lack of fusion pores. To mitigate sinter formation and its detrimental effects on DED component quality, it is essential that the powder delivery spot area is smaller than the melt pool, ensuring most powder lands in the melt pool.

36 MATERIALS SCIENCE↗

Assessing the performance of MagLIF with 3D MHD simulations

The Magnetized Liner Inertial Fusion (MagLIF) experimental platform at Sandia National Laboratories has realized a number of recent improvements in electrical current and laser preheat coupling but fusion yields are below expectations, based on modeling with clean (that is, simulations with no interfacial instabilities and no mix) two-dimensional (2D) magneto-hydrodynamics (MHD) simulations, by a factor of 5 or more. However, magnetized liner implosions are known to produce helical magneto-Rayleigh–Taylor (MRT) modes and complex stagnation structures that cannot be directly modeled in 2D. This paper presents the results of 3D HYDRA MHD simulations, including helical MRT, showing that degradation from these instabilities can readily reproduce experimental yields, but it is difficult to simultaneously match the yield along with inferred fuel temperature, pressure, and burn history (assessed with x-rays), which are larger in the experiments considered here. Additional analysis methods and future experiments are proposed to help address the discrepancies. The 3D simulations also show, without substantive improvements to stability, changing the applied Bz or preheat is unlikely to increase performance of MagLIF to the same degree as clean 2D simulations. Finally, the first 3D HYDRA simulations with the Hall term show the ab initio production of helical MRT and produce a clear change in stagnation morphology compared to pre-seeded simulations without Hall. In spite of the differences, the simulations still produce comparable fusion performance but with longer, lower power, neutron yield history.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Limitations and Feasibility of Mini X-Ray Devices in Space Environments

LIMITATIONS AND FEASIBILITY OF MINI X-RAY DEVICES IN SPACE ENVIRONMENTS As space exploration advances toward long-duration missions, reliable medical diagnostic tools become increasingly critical. The miniature x-ray (XR) technology demonstrations by the Exploration Medical Capability (ExMC) and the Exploration Medical Integrated Product Team (XMIPT) aim to assess the feasibility and utility of miniature XR devices in spaceflight. This abstract explores the limitations of current miniature XR systems, the challenges of training crew members, the potential role of clinical decision support systems (CDSS), and the feasibility of ground-based image interpretation. We also propose the integration of miniature XR into other ExMC efforts aimed at identifying the capabilities and resources needed for future exploration class missions. One of the primary challenges with miniature XR devices is the ability to achieve specific anatomical views, particularly in the confined and weightless conditions of a spacecraft. Operators may struggle to acquire diagnostic-quality images when space is limited for proper patient positioning and the volume of the imaging device. Since space radiation and detector limitations may further impact image quality, the flexibility of the operating procedures of these devices will be critical for their success in space applications. CHALLENGES IN TRAINING CREW TO OPERATE IMAGING DEVICES Training in the skills necessary to acquire diagnostic-quality scans may be a barrier for non-clinician crewmembers. The curriculum developed for crew medical officers (CMOs) will require simplification and adaptation to fit into the highly truncated pre-flight training period. Therefore, hands-on familiarization and simulation, both pre-flight and just-in-time training during missions, will be crucial to ensuring the crew can operate the devices in real-life situations. The ability to adjust acquisition parameters must be simplified or made automatic through exam selections on equipment user interfaces, and subject and operator positioning should be assisted with laser guidance and pictorial guides. POTENTIAL FOR CDSS OR ARTIFICIAL INTELLIGENCE (AI)-ASSISTED CDSS CDSS and AI-assisted CDSS offer significant promise in assisting crew members with limited medical training. These systems could provide real-time feedback on image quality and interpretation, helping to mitigate the risks of human error during space missions. Integrating procedural guidance tools, such as virtual and augmented reality, will support crewmembers in accurately positioning patients and obtaining high-quality images. However, the success of such systems will depend on the development of robust training datasets, integration with spaceflight-rated hardware, and the medical decision-making capabilities of operators. FEASIBILITY OF GROUND INTERPRETATION AND DATA TRANSMISSION Reliance on ground-based interpretation may prove difficult for acute care during exploration class-missions due to delays in transmission with increasing distance from Earth or complete communication blackout periods. In such instances where immediate interpretation for clinical intervention is required, crew must be able to interpret the images independently or utilize AI-based assistance to do so. File sizes for XR exams can also be large if numerous images are acquired and bandwidth constraints may limit data transmissions for both radiography and ultrasound exams. FUTURE WORK AND INTEGRATION INTO THE EVIDENCE LIBRARY Future work proposes integrating miniature XR devices into NASA’s Evidence Library to address medical conditions identified as significant contributors to crew morbidity and mortality. The possibility of combining miniature XR with other imaging modalities, such as ultrasound devices, is also under investigation. In conclusion, while miniature XR technology holds potential for extraterrestrial medical systems, there are significant challenges to overcome. Training, integration of AI tools, dedicated exam protocols for microgravity, and improved data transmission systems will be key to realizing the full benefits of miniature XR technology in space.

A M Nelson↗

Optical versus radiographic imaging and tomography: introduction to the ROADS feature issue

Optical imaging is an ancient branch of imaging dating back to thousands of years. Radiographic imaging and tomography (RadIT), including the first use of X-rays by Wilhelm Röntgen, and then, $γ$ -rays, energetic charged particles, neutrons, etc. are about 130 years young. The synergies between optical and radiographic imaging can be cast in the framework of these building blocks: Physics, Sources, Detectors, Methods, and Data Science, as described in Appl. Opt. 61, RDS1 (2022). Optical imaging has expanded to include three-dimensional (3D) tomography (including holography), due in to part the invention of optical (including infrared) lasers. RadIT are intrinsically 3D because of the penetrating power of ionizing radiation. Both optical imaging and tomography (OIT) and RadIT are evolving into even higher dimensional regimes, such as time-resolved tomography (4D) and temporarily and spectroscopically resolved tomography (4D + ). Further advances in OIT and RadIT will continue to be driven by desires for higher information yield, higher resolutions, and higher probability models with reduced uncertainties. Synergies in quantum physics, laser-driven sources, low-cost detectors, data-driven methods, automated processing of data, and artificially intelligent data acquisition protocols will be beneficial to both branches of imaging in many applications. These topics, along with an overview of the Radiography, Applied Optics, and Data Science virtual feature issue, are discussed here.

47 OTHER INSTRUMENTATION↗