Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser-induced fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Spectral Data Fusion From Handheld Laser-Induced Breakdown Spectroscopy (LIBS) and X-ray Fluorescence (XRF) Analyzers for Improved Detection of Cerium in a Simulated Dispersal Accident

Here, this work implements a mid-level data fusion methodology on spectral data from handheld X-ray fluorescence and laser-induced breakdown spectroscopy analyzers to quantify plutonium surrogate (CeO 2 ) contamination in soil samples for the first time. Spectral data from each analyzer were used independently to train supervised machine learning regressions to predict Ce concentration. Fused features from both data sets were then used to train the same models, comparing prediction performance by evaluating model precision and sensitivity. Fusing principal component scores from the two sensors yielded an order of magnitude improvement in precision and sensitivity of predictions made with an artificial neural network, compared to predictions made by models trained on independent sensor data. As a result, a boosted ensemble trained on the fused spectral features yielded an ideal predictor with root-mean-squared error on the order of 10 –6 and calculated limit of detection order 10 –5 wt %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Waveform-dependent air fluorescence from neutral and ionic nitrogen molecules

Laser-induced air fluorescence in the ultraviolet regime is primarily attributed to transitions between the C and B states in excited neutral N 2 molecules and between the B and X states in N$^+_2$ ions. However, the mechanism underlying the former remains contentious, as direct population to the C state by light fields is forbidden by electron spin constraints. In this work, we investigate the mechanism of air fluorescence from excited neutral N 2 molecules by carrier-envelope phase–stabilized sub–4 femtosecond pulses. Our results show that fluorescence from N$^+_2$ ions reaches a maximum with cosine-like pulses, while fluorescence from excited neutral N 2 molecules peaks with sine-like pulses. In addition, by scanning the chirp of the driving pulse, we find that ionic fluorescence is maximized with chirp-free pulses, whereas neutral fluorescence favors negatively chirped pulses. These observations, supported by classical trajectory Monte Carlo simulations, support the mechanism of intersystem crossing from excited spin-singlet states, which are populated via recollision-induced strong-field excitation.

Science & Technology - Other Topics↗

Visualization of post-detonation fireball flowfields and comparison to CFD modeling

Visualization of flow structures within post-detonation fireballs has been performed for benchmark validation of numerical simulations. Custom pressed PETN explosives with a 12-mm diameter hemispherical form factor were used to produce a spherically symmetric post-detonation flow with low soot yield. Hydroxyl-radical planar laser induce fluorescence (OH-PLIF) was employed to visualize the structure ranging from approximately 10 μs to 35 μs after shock breakout from the explosive pellet. Fireball simulations were performed using the HyBurn Computational Fluid Dynamics (CFD) package. Experimental OH-PLIF results were compared to synthetic OH-PLIF from post-processing of CFD simulations. From the comparison of experimental and synthetic OH-PLIF images, CFD is shown to replicate much of the flow structure observed in the experiments, revealing potential differences in turbulent length scales and OH kinetics. Furthermore, results provide significant advancement in experimental resolution of these harsh turbulent combustion environments and validate physical models thereof.

Detonator↗

High-fidelity Experiments of Turbulent Buoyant Jets from Simultaneous Particle Image Velocimetry and Laser Induced Fluorescence

Accurate models of turbulent buoyant flows are essential for the design of nuclear reactors thermal hydraulics and passive safety systems. However, available models fail to fully capture the physics of turbulent mixing when buoyancy becomes predominant with respect to momentum. Therefore, high-fidelity experiments of well-controlled fundamental flows are needed to develop and validate more accurate models. We performed experiments of positive and negative turbulent buoyant jets, both in uniform and stratified environments, with the aim of understanding the thermal hydraulics of turbulent mixing with variable density and providing high-fidelity data for the development and validation of turbulence models. Non-intrusive, simultaneous Particle Image Velocimetry and Laser Induced Fluorescence measurements were carried out to acquire instantaneous velocity and concentration fields on a vertical section parallel to the axis of a jet in the self-similar region. The Refractive Index Matching method was applied to measure high-resolution buoyant jets with up to 8.6% density difference. These data are free of the typical errors that characterize optical measurements of buoyancy driven flows (e.g., natural and mixed convection) where the refractive index of the fluid is inhomogeneous throughout the measurement domain. Turbulent statistics and entrainment of buoyant jets in uniform and stratified environments are presented. These data are compared with non-buoyant jets in uniform environment, as a reference to investigate the effects of buoyancy and stratification on turbulent mixing. The results will be used for the assessment of current turbulence models and as basis for the development of a new one that captures turbulent mixing.

42 ENGINEERING↗

Insights into Sustainable Nitrogen Fixation by Gas-phase Spectroscopic Measurements and Global Modeling of Reaction Intermediates in Humid Nitrogen Plasma

In this article, there is growing interest in reacting molecular nitrogen and water to sustainably synthesize fixed forms of nitrogen such as ammonia. In particular, low-temperature plasmas can activate these relatively inert feedstocks at or near room temperature without a catalyst. However, because of the enhanced reactivity and nonequilibrium chemistry, a diverse range of products is formed, and the underlying reaction mechanisms are exceedingly complex. In this work, we studied a simplified reactor consisting of a gaseous plasma containing controlled mixtures of nitrogen gas and water vapor. Densities of key chemical species such as N, H, OH, NH, and NO were measured by emission and laser-based spectroscopy as a function of the relative humidity. A global model was constructed and the reaction network was validated by comparing calculated species densities with experiments. We discover that N, a key initial intermediate for ammonia, strongly decreases in the presence of water vapor, and as a result, ammonia formation becomes limited at high relative humidity. This decrease is surprisingly not because N itself reacts, but because one of its main sources, an excited molecular nitrogen state, is reacted away. In addition, oxidation pathways for nitrogen, which lead to NO and related products, are found to be favored over reduction pathways because the corresponding reverse reactions are less significant. Together, this understanding helps explain previously reported observations of selectivity toward nitrogen oxides over ammonia, particularly at higher relative humidities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid-to-gas transfer of sodium in a liquid anode glow discharge

Solute transfer from the liquid to the gas phase in plasmas has been widely used in analytical chemistry often focused on liquid cathode discharges. In this study, we report on time-resolved absolute density measurements of sodium in a glow discharge plasma with a NaCl solution anode using two-photon absorption laser induced fluorescence. The averaged maximum sodium density is found to be similar to the electron density in the discharge consistent with plasma-induced vapor generation. Random sodium flashes were also observed extending into the plasma afterglow and are attributed to sodium particles falling back on the liquid surface. Cataphoresis can explain the location of the maximum sodium density near the cathode side of the electrode gap rather than near the liquid anode region.

chemical vapor generation↗

RF antenna helicity dependent particle heating in a helicon source

Experiments have demonstrated that ion phenomena, such as the lower hybrid resonance, play an important role in helicon source operation. Damping of the slow branch of the bounded whistler wave at the edge of a helicon source (i.e. the Trivelpiece-Gould mode) has been correlated with the creation of energetic electrons, heating of ions at the plasma edge, and anisotropic ion heating. Here we present ion velocity distribution function measurements, electron density and temperature measurements, and magnetic fluctuation measurements on both sides of an m = |1| helical antenna in a helicon source as a function of the driving frequency, magnetic field strength, and magnetic field orientation relative to the antenna helicity. Significant electron and ion heating (up to two times larger) occurs on the side of the antenna consistent with the launch of the m = +1 mode. The electron and ion heating occurs within one electron skin depth of the plasma edge, where slow wave damping is expected. The source parameters for enhanced particle heating are also consistent with lower hybrid resonance effects, which can only occur for Trivelpiece-Gould wave excitation.

wave modes↗

Femtosecond two-photon-resonant parametric four-wave mixing detection of atomic hydrogen

Here, we demonstrate an ultrafast parametric four-wave mixing method for the collisional-quenching-free detection of atomic hydrogen. Two photons of 243 nm light resonantly excite the n = 1 to n = 2 transition of atomic hydrogen, and a third probe photon scatters from the electronic coherence to generate the parametric emission of a degenerate signal photon. Laser-induced photofragmentation fluorescence from water, also excited with the same 243 nm pulses, is used as a convenient method to visualize beam overlap in space and time. The femtosecond time resolution enables the suppression of unwanted nonresonant contributions to the signal and separation from resonant mixing in water molecules because of the significantly different coherence lifetimes. A folded BOXCARS phase-matching configuration yields a spatially isolated, laser-like, signal beam, amenable to measurements in highly luminous backgrounds. Measurements in an H 2 /CH 4 /air flame demonstrate quantitative agreement with simulated H-atom concentration profiles. A coherence decay time constant of 42 ps is recorded in the atmospheric pressure flame.

Kliewer, Christopher Jesse [Sandia National Labora↗

Flame Characterization of a Hydrogen Micromix Burner using Experimental and Numerical Methods - Extended Abstract

Micromix combustion presents a promising solution for integrating hydrogen into gas turbine combustors, offering rapid and compact air-fuel mixing that effectively shortens the combustion zone and significantly reduces nitrogen oxides (NOX) emissions. A major challenge in hydrogen combustion systems is flashback, which is mitigated through short mixing lengths and high flow velocities. This study investigates three fuel injector designs – zero swirl, low swirl, and high swirl – for a 6-mm inner diameter nozzle, where hydrogen is injected through six 0.3 mm diameter holes in a jet-in-crossflow configuration relative to the airstream. Numerical simulations indicate stable flame formation, moderate peak flame temperatures, and subsequent low NOx potential for all designs. These injectors have been fabricated using additive manufacturing, and upcoming experiments will explore flame structure and NOx behavior across varying fuel injection angles, equivalence ratios and pre-mixer velocities. These efforts aim to advance the development of low-emission hydrogen micromix combustion.

hydrogen↗

Structure Matters: Asymmetric CO Oxidation at Rh Steps with Different Atomic Packing

Curved crystals are a simple but powerful approach to bridge the gap between single crystal surfaces and nanoparticle catalysts, by allowing a rational assessment of the role of active step sites in gas-surface reactions. Using a curved Rh(111) crystal, here, we investigate the effect of A-type (square geometry) and B-type (triangular geometry) atomic packing of steps on the catalytic CO oxidation on Rh at millibar pressures. Imaging the crystal during reaction ignition with laser-induced CO 2 fluorescence demonstrates a two-step process, where B-steps ignite at lower temperature than A-steps. Such fundamental dissimilarity is explained in ambient pressure X-ray photoemission (AP-XPS) experiments, which reveal partial CO desorption and oxygen buildup only at B-steps. AP-XPS also proves that A-B step asymmetries extend to the active stage: at A-steps, low-active O–Rh–O trilayers buildup immediately after ignition, while highly active chemisorbed O is the dominant species on B-type steps. We conclude that B-steps are more efficient than A-steps for the CO oxidation.

36 MATERIALS SCIENCE↗

Photoionization of seeded combustion products as a method of enhancing the efficiency of magnetohydrodynamic power generators

Here, in this study, we performed an experimental and computational investigation into the feasibility of utilizing photoionization to enhance the electrical conductivity of seeded oxy-fuel combustion products and improve the performance of magnetohydrodynamic (MHD) power generators. We applied a variety of optical and microwave diagnostics to study the ionization and recombination processes of potassium excited by an excimer laser in a high-velocity oxy-fuel free jet. Computational fluid dynamic (CFD) simulations were performed to model the thermophysical properties and species densities of the free jet. The CFD results were validated with position-dependent potassium concentration measurements. Electron recombination exponential lifetimes were measured through time-resolved microwave transmission. The experimental electron lifetimes were compared with lifetimes calculated from CFD-predicted species densities and literature recombination rates. It was determined that K + or O 2 are the most likely recombination partners for photoionized electrons. Time-resolved fluorescence measurements provided evidence of an ionization pathway involving a two-photon ionization of KOH . Finally, a zero-dimensional chemical kinetic model was developed to assess the fundamental viability of inducing a non-equilibrium electron population to provide a net energy return in combustion-driven MHD power generators. We determined that a high energy return is feasible for targeting electrode boundary layers with ultraviolet photoionization. We also found that photoionization could potentially lower the required temperature of the bulk gas flow.

20 FOSSIL-FUELED POWER PLANTS↗

Machine learning in analytical spectroscopy for nuclear diagnostics [Invited]

Analytical spectroscopy methods have shown many possible uses for nuclear material diagnostics and measurements in recent studies. In particular, the application potential for various atomic spectroscopy techniques is uniquely diverse and generates interest across a wide range of nuclear science areas. Over the last decade, techniques such as laser-induced breakdown spectroscopy, Raman spectroscopy, and x-ray fluorescence spectroscopy have yielded considerable improvements in the diagnostic analysis of nuclear materials, especially with machine learning implementations. These techniques have been applied for analytical solutions to problems concerning nuclear forensics, nuclear fuel manufacturing, nuclear fuel quality control, and general diagnostic analysis of nuclear materials. The data yielded from atomic spectroscopy methods provide innovative solutions to problems surrounding the characterization of nuclear materials, particularly for compounds with complex chemistry. Implementing these optical spectroscopy techniques can provide comprehensive new insights into the chemical analysis of nuclear materials. In particular, recent advances coupling machine learning methods to the processing of atomic emission spectra have yielded novel, robust solutions for nuclear material characterization. This review paper will provide a summation of several of these recent advances and will discuss key experimental studies that have advanced the use of analytical atomic spectroscopy techniques as active tools for nuclear diagnostic measurements.

Rao, Ashwin P. (ORCID:0000000319312568)↗

Analytical comparisons of handheld LIBS and XRF devices for rapid quantification of gallium in a plutonium surrogate matrix

This work compares a portable laser-induced breakdown spectroscopy (LIBS) analyzer to a portable X-ray fluorescence (XRF) device for quantification of gallium (Ga) in a plutonium surrogate matrix of cerium (Ce) for the first time. Calibration methods are developed with spectra of Ce–Ga samples from both devices. Here, metrics such as limit of detection (LoD) and mean average percent error (MAPE) are examined to evaluate calibration performance. While the portable LIBS device can yield a nearly instantaneous analytical measurement, its accuracy is hampered by self-absorption. By employing a self-absorption correction and increasing gating delay, LIBS calibrations with errors in the low single percents and LoDs of 0.1% Ga were constructed. The XRF device produces calibrations with superlative sensitivity, yielding LoDs for gallium in the low tens of parts-per-million (ppm), two orders of magnitude lower than the corrected LIBS models. However, a clear trade-off of measurement fidelity is established between the instantaneous analysis of the LIBS device and the minutes-long XRF measurement yielding superior detection limits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser-based conversion electron Mössbauer spectroscopy of 229 ThO 2

The exceptionally low-energy 229 Th nuclear isomeric state is expected to provide several new and powerful applications, including the construction of a robust and portable solid-state nuclear clock, perhaps contributing to a redefinition of the second, exploration of nuclear superradiance and tests of fundamental physics. Further, analogous to the capabilities of traditional Mössbauer spectroscopy, the sensitivity of the nucleus to its environment can be used to realize laser Mössbauer spectroscopy and, with it, new types of strain and temperature sensors and a new probe of the solid-state environment, all with excellent sensitivity. However, current models for examining the nuclear transition in a solid require the use of a high-bandgap, vacuum ultraviolet (VUV) transmissive host, severely limiting the applicability of these techniques. Here we report the first, to the authors’ knowledge, demonstration of laser-induced conversion electron Mössbauer spectroscopy (CEMS) of the 229 Th isomer in a thin ThO 2 sample whose bandgap (approximately 6 eV) is considerably smaller than the nuclear isomeric state energy (8.4 eV). Unlike fluorescence spectroscopy of the 229 Th isomeric transition, this technique is compatible with materials whose bandgap is less than the nuclear transition energy, opening a wider class of systems to study and the potential of a conversion-electron-based nuclear clock.

36 MATERIALS SCIENCE↗

Thermal-Strain-Enabled Enhanced Emission from UV Laser-Induced Defect Levels near the Surface of Multilayer MoS 2

Monolayer two-dimensional (2D) materials have been intensively studied while research on multilayers is still in its infancy. Here, we induce defects inside bulk MoS 2 through thermal annealing and near the surface of multilayer MoS 2 using 375 nm laser irradiation, and investigate their photoluminescence (PL) and fluorescence lifetime imaging (FLIM). Enhanced emission is limited within a certain MoS 2 thickness. The observed enhanced emission is evidenced by a threshold behavior in super-linear PL intensity increase, strong polarization effects, and increased lifetime of defect peak. The laser power threshold for enhanced emission is much smaller in defects near the surface than that inside the bulk of multilayer MoS 2 . The mechanical strain from a wrinkle of the sample further lowers the laser power threshold for enhanced emission. By exciting with a 639 nm laser that is close to the fundamental gap between the conduction band minimum and the valence band maximum, the lifetime of defect enhanced emission increased by 5 times. Furthermore, one of the competing indirect bandgap emissions disappears, and the defect emission peak dominates the PL spectrum in the wrinkle area with a strain. Furthermore, the discovered principle can be applied to future studies on the integration of enhanced emission and single photon emission involving selectively depopulating the conduction band of the host crystal to defect levels for quantum emitters.

2D materials↗

Three-dimensional characterization of modifications in sapphire exposed to laser-induced damage using multimodal spectral microimaging

Sapphire (Al 2 O 3 ) is a commonly used dielectric material with many applications in lasers and optical systems. Owing to its high resistivity to laser induced damage, it is particularly suitable for use in high power laser systems. This work focuses on developing techniques to characterize material modifications in sapphire. These techniques were applied following localized laser induced ablation, commonly referred to as laser-damage, resulting from exposure to single 100-ps and 6-ns pulses. Measurements of fluorescence-based piezospectroscopy and confocal Raman microscopy were performed with spatial resolution on the order of 1 μ m. Raman microscopy reveals that the relaxation of material exposed to the rapid laser heating, elastic and viscoplastic deformation, melting, and solidification leads to the formation of a polycrystalline material phase. In addition, narrowband fluorescence lines, referred to as R 1 and R 2 , exhibit pressure-sensitive changes to their spectral profiles, allowing 3D internal stresses to be recorded with spatial resolution of the order of a few micrometers.

Laser-damage↗