Search NASA⌕ Search

SEARCH · Search NASA

Results for “leakage detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

ISS External Microorganisms: Collecting Planetary Protection Samples During Extravehicular Activity

Introduction: We have designed1, built, and tested a sampling kit (Fig. 1) to aseptically collect microbiological samples from exterior surfaces on the ISS (International Space Station). The kit was flown to ISS as part of the NG-19 commercial cargo mission in August of 2023. Astronauts will use the kit to collect samples from six exterior surfaces on ISS. These samples will be frozen at -80°C after collection and returned to the ground for next generation DNA sequencing. The results of this experiment will help inform planetary protection requirements for crewed missions. We hypothesize that there are detectable microbial communities outside ISS and that these communities originate from inside ISS. Current life support systems do not include any components for reducing microbial leakage. Gases are vented from inside ISS without filtration and there are currently no protocols in place to minimize bioburden on space suit exteriors prior to use. It is important to quantify the bioburden on current vehicles so that achievable limits can be set for crewed missions to astrobiologically relevant locations like Mars. Figure 1: The sampling kit contains eight swab canisters in total (six on the top and two on the bottom). A resuable end effector (1) is used to remove and reinstall the swabs. The kit also contains a handrail (2), tether loop (3), and, bayonet probes(4) to allow easy manipulation during EVA. Methods: We have designed a kit to carry 8 commercially available foam swabs into and out of vacuum without compromising the swabs’ sterility. The specially designed swab canisters contain a 0.2 µm Teflon filter that allows the canister to accommodate pressure changes without introducing unwanted contaminants. The kit meets existing EVA (Extravehicular Activity) safety requirements and has been used by human test subjects in the neutral buoyance lab and at vacuum in test chambers at the Johnson Space Center. In the early part of 2024, astronauts will use this sampling kit to swab six surfaces on the exterior of ISS. We will collect samples from: the airlock vestibule, the interior surface of the airlock thermal cover, an exterior handrail, a vent connected to the CO2 removal system, and a vent connected to the payload vacuum system inside ISS. Approximately 300 cm2 will be swabbed at each location. A seventh swab will be exposed to the vacuum of space without touching any surfaces as a blank. The eighth swab will remain sealed as a process control. After the EVA the swab kit will be frozen at -80°C and returned to earth at the earliest possible opportunity. The samples will remain frozen until they are thawed for next generation DNA sequencing on earth. We will use amplicon sequencing to identify any bacteria, archaea or fungi present in the samples. If there is enough DNA present, we will use shotgun metagenomic sequencing to further characterize the microbial ecology outside ISS. Preliminary Results: Results from ground-based testing demonstrate that the swab kit is capable of cycling in and out of vacuum without contaminating the swabs. Test subjects, wearing flight-like EVA gloves could remove swabs from the canister and sample discrete locations without inadvertently touching any other surfaces. Several types of bacteria and fungi were collected during these ground tests and survived up to 6 hours at vacuum. This includes non-spore forming bacterial like Staphyloccus capitis that are not traditionally considered extremophiles. Shotgun metagenomic sequencing of the ground-test samples revealed bacteria associated with human skin and airways on the exterior of space suits used during these tests 2 In addition to these results we will present preliminary results from our space-flight samples. We will also present lessons learned from attempting to collect microbiological samples during an EVA and describe how our results will affect planetary protection requirements for future crewed missions.

Aaron B. Regberg↗

Recent progress in photoelectron image detection with CCDs

Intensified CCDs (ICCDs) were built and operated. These ICCDs were electrostatically and magnetically-focussed image tubes which use CCDs as anodes. The ICCDs detected single photoelectrons, and have electron gain very near that which was predicted. The first single-pixel pulse-height distributions were presented, and the leakage current was shown to increase as a function of photoelectron irradiation. The advantages and disadvantages of front- and rear-illuminated designs were discussed in light of differing applications requirements.

Choisser, J. P.↗

Chemical Mapping of Vesta and Ceres

Following successful science operations at Vesta, the Dawn spacecraft is headed for an encounter with Ceres in 2015. What have we learned at Vesta? And, what do we expect to learn by comparing Vesta and Ceres? We will address these questions from the standpoint of geochemistry. Dawn's Gamma Ray and Neutron Detector (GRaND) is sensitive to the elemental composition of surface materials to depths of a few decimeters [1]. Gamma rays and neutrons, produced by the steady bombardment of galactic cosmic rays and by the decay of naturally ]occurring radioisotopes (K, Th, U), provide a chemical fingerprint of the regolith. Analysis of planetary radiation emissions enables mapping of specific elements (such as Fe, Mg, Si, Cl, and H) and compositional parameters (such as average atomic mass), which provide information about processes that shaped the planet1s surface and interior. Dawn has exceeded operational goals for GRaND at Vesta, accumulating an abundance of nadir-pointed data during five months in a 210 km, low altitude mapping orbit around Vesta (265-km mean radius). Chemical information from gamma ray and neutron measurements was used to test the connection between Vesta and the howardite, eucrite, and diogenite (HED) meteorites [2]. Additionally, GRaND searched for evolved, igneous lithologies [3], mantle and upper crustal materials exposed in large impact basins, mesosiderite compositions, and hydrogen in Vesta1s bulk regolith. Results of our analyses and their implications for thermal evolution and regolith-processes will be presented. The possibility of a subcrustal ocean [4, 5] and lack of cerean meteorites makes water-rich Ceres a compelling target of exploration [6]. If Ceres underwent aqueous differentiation, then crustal overturn or gas driven volcanism may have significantly modified its primitive surface; and products of aqueous alteration (e.g. [7]) would detectable by GRaND [1]. For example, the presence of Cl in salts, associated with liquid-water-processes, would have a profound effect on the thermal neutron leakage flux. GRaND is sensitive to H and H-layering, which may be in the form of endogenic water ice or hydrous minerals on Ceres. Ammonia ice (e.g., from recent cryovolcanism) would produce a distinctly different neutron signature than water ice [1]. Prospective results for GRaND at Ceres will be presented in the context of what we have learned about Vesta.

Prettyman, Thomas H.↗

Magnetoresistive Flux Focusing Eddy Current Flaw Detection

A giant magnetoresistive flux focusing eddy current device effectively detects deep flaws in thick multilayer conductive materials. The probe uses an excitation coil to induce eddy currents in conducting material perpendicularly oriented to the coil s longitudinal axis. A giant magnetoresistive (GMR) sensor, surrounded by the excitation coil, is used to detect generated fields. Between the excitation coil and GMR sensor is a highly permeable flux focusing lens which magnetically separates the GMR sensor and excitation coil and produces high flux density at the outer edge of the GMR sensor. The use of feedback inside the flux focusing lens enables complete cancellation of the leakage fields at the GMR sensor location and biasing of the GMR sensor to a location of high magnetic field sensitivity. In an alternate embodiment, a permanent magnet is positioned adjacent to the GMR sensor to accomplish the biasing. Experimental results have demonstrated identification of flaws up to 1 cm deep in aluminum alloy structures. To detect deep flaws about circular fasteners or inhomogeneities in thick multi-layer conductive materials, the device is mounted in a hand-held rotating probe assembly that is connected to a computer for system control, data acquisition, processing and storage.

Russell A Wincheski↗

Magnetoresistive flux focusing eddy current flaw detection

A giant magnetoresistive flux focusing eddy current device effectively detects deep flaws in thick multilayer conductive materials. The probe uses an excitation coil to induce eddy currents in conducting material perpendicularly oriented to the coil's longitudinal axis. A giant magnetoresistive (GMR) sensor, surrounded by the excitation coil, is used to detect generated fields. Between the excitation coil and GMR sensor is a highly permeable flux focusing lens which magnetically separates the GMR sensor and excitation coil and produces high flux density at the outer edge of the GMR sensor. The use of feedback inside the flux focusing lens enables complete cancellation of the leakage fields at the GMR sensor location and biasing of the GMR sensor to a location of high magnetic field sensitivity. In an alternate embodiment, a permanent magnet is positioned adjacent to the GMR sensor to accomplish the biasing. Experimental results have demonstrated identification of flaws up to 1 cm deep in aluminum alloy structures. To detect deep flaws about circular fasteners or inhomogeneities in thick multilayer conductive materials, the device is mounted in a hand-held rotating probe assembly that is connected to a computer for system control, data acquisition, processing and storage.

Wincheski, Russell A.↗

Nulling interferometers: the importance of systematic errors and the X-Array configuration

The nulling interferometers proposed for planet detection are arrays of collector telescopes whose amplitudes and phases are carefully controlled to generate a null response at the star. Perturbations in the amplitude and phase response of the instrument lead to time-dependent fluctuations in the stellar leakage that can mimic a planet signal. Understanding these non-linear systematic errors is important, since they drive most of the instrument requirements for missions such as the Terrestrial Planet Finder and Darwin. We show that 'amplitude-phase' errors are the dominant source of instrument noise. They are unaffected by the technique of phase chopping, increase rapidly at short wavelengths, are largely independent of the size and transmission efficiency of the collector optics, and depend only weakly on the nulling configuration and distance to the target system. Detection of an Earth around a G-type star like the sun requires -1.5 nm of path control and -0.1% control of the amplitude, integrated over all frequencies, including DC. This paper also introduces the X-Array - a new nulling configuration with 4 collectors and a central combiner arranged in an X pattern. This has a number of advantages over the standard dual Bracewell layout, and over other configurations that have been proposed

Dubovitsky, Serge↗

Leak detection with expandable coatings

Developed and evaluated is a system for leak detection that can be easily applied over separable connectors and that expands into a bubble or balloon if a leak is present. This objective is accomplished by using thin films of Parafilm tape wrapped over connectors, which are then overcoated with a special formulation. The low yield strength and the high elongation of the envelope permit bubble formation if leakage occurs. This system is appropriate for welds and other hardware besides separable connectors. The practical limit of this system appears to be for leaks exceeding 0.000001 cc/sec. If this envelope is used to trap gases for mass spectrometer inspection, leaks in the range of ten to the minus 8th power cc/sec. may be detectable.

Source record↗

Visible nulling interferometer

The direct detection of Earthlike planets in the visible is a very challenging goal. This paper describes a new concept for visible direct detection of Earths using a nulling interferometer instrument behind a 4m telescope in space. The basic concept is described along with the key advantages of the nulling interferometer over more traditional approaches, an apodized aperture telescope or coronagraph. In the baseline design, a 4 beam nuller produces a very deep theta^4 null. With perfect optics, the stellar leakage is less than le-11 of the starlight at the location of the planet. With diffraction limited (lambda/20) telescope optics suppression of the starlight to -1e-10 would be possible.

Direct planet detection nulling coronagraph↗

The Ly(alpha) Line Profiles of Ultraluminous Infrared Galaxies: Fast Winds and Lyman Continuum Leakage

We present new Hubble Space Telescope Cosmic Origins Spectrograph far-ultraviolet (far-UV) spectroscopy and Keck Echellete optical spectroscopy of 11 ultraluminous infrared galaxies (ULIRGs), a rare population of local galaxies experiencing massive gas inflows, extreme starbursts, and prominent outflows. We detect Ly(alpha) emission from eight ULIRGs and the companion to IRAS09583+4714. In contrast to the P Cygni profiles often seen in galaxy spectra, the Ly(alpha) profiles exhibit prominent, blueshifted emission out to Doppler shifts exceeding −1000 km/s in three H II-dominated and two AGN-dominated ULIRGs. To better understand the role of resonance scattering in shaping the Ly(alpha) line profiles, we directly compare them to non-resonant emission lines in optical spectra. We find that the line wings are already present in the intrinsic nebular spectra, and scattering merely enhances the wings relative to the line core. The Ly(alpha) attenuation (as measured in the COS aperture) ranges from that of the far-UV continuum to over 100 times more. A simple radiative transfer model suggests the Ly(alpha) photons escape through cavities which have low column densities of neutral hydrogen and become optically thin to the Lyman continuum in the most advanced mergers. We show that the properties of the highly blueshifted line wings on the Ly(alpha) and optical emission-line profiles are consistent with emission from clumps of gas condensing out of a fast, hot wind. The luminosity of the Ly(alpha) emission increases nonlinearly with the ULIRG bolometric luminosity and represents about 0.1-1% of the radiative cooling from the hot winds in the H II-dominated ULIRGs.

Infrared↗

Systematics of heavy ion enhancements in solar flares

Using Lexan and glass detectors, the composition of solar particles with atomic number 2 or greater was determined as a function of energy from approximately 0.2 to 50 MeV/nucleon in four flares of quite different intensity and during a time when the sun was nearly quiet. Fe is nearly completely stripped. The enhancement factor increases with atomic number at a given energy but decreases with energy. Heavy element enhancements are detectable at higher energies in stronger flares. They occurred in ancient as well as in present-day flares. We have observed Li and Be in one flare. Incomplete ionization, preferential leakage of heavy ions, energy loss by ionization, and nuclear reactions appear to be involved in solar particle production.

Price, P. B.↗

Mass-Flow-Meter Leak-Testing System

Improved leak-testing system incorporates mass-flow meter as primary sensor for measurement of leakage rate. System easier to use and more reliable and enables leak tests to be completed in less time. Produces test data more plentiful, more accurate, and better suited to leak detection and diagnosis. Operates over range of test conditions, including pressures from atmospheric to 1,000 psi, temperatures from 50 to 120 degrees F and volumes from less than 1 in.(sup3) to 22 in.(sup3). Sensitive enough to measure absorbed gas seeping from O-ring seals after test pressure released.

Sorensen, Eric B.↗

Lightning Pin Injection Testing on MOSFETS

Lightning transients were pin-injected into metal-oxide-semiconductor field-effect transistors (MOSFETs) to induce fault modes. This report documents the test process and results, and provides a basis for subsequent lightning tests. MOSFETs may be present in DC-DC power supplies and electromechanical actuator circuits that may be used on board aircraft. Results show that unprotected MOSFET Gates are susceptible to failure, even when installed in systems in well-shielded and partial-shielded locations. MOSFET Drains and Sources are significantly less susceptible. Device impedance decreased (current increased) after every failure. Such a failure mode may lead to cascading failures, as the damaged MOSFET may allow excessive current to flow through other circuitry. Preliminary assessments on a MOSFET subjected to 20-stroke pin-injection testing demonstrate that Breakdown Voltage, Leakage Current and Threshold Voltage characteristics show damage, while the device continues to meet manufacturer performance specifications. The purpose of this research is to develop validated tools, technologies, and techniques for automated detection, diagnosis and prognosis that enable mitigation of adverse events during flight, such as from lightning transients; and to understand the interplay between lightning-induced surges and aging (i.e. humidity, vibration thermal stress, etc.) on component degradation.

Ely, Jay J.↗

Photonic Source for Binary Source Simulations

More than half of the sun-like stars are in binary systems or have companions that hinder the search for planets around them using traditional technologies. There are only 69 FGK dwarfs within ten pc that can harbor true earth analogs. Direct imaging can detect and study the habitability of those targets measuring the chemical composition of the atmosphere, and astrometry can measure the planet's mass. We use Multi-Star Wavefront Control (MSWC), a technique that removes stellar leakage from both stellar components to enable direct imaging of binary systems. Currently, there is a technology demonstration experiment of MSWC for the Roman coronagraph instrument at the High Contrast Imaging Testbeds operated at JPL. One of the challenges for this experiment is to produce a binary source where both stars are incoherent with each other at close physical separation. On the other hand, to measure masses, it is possible to obtain relative astrometry measurements between the binary. The TOLIMAN concept proposes to use a diffractive pupil to calibrate the distortion and detector effects to reach 1uas astrometric accuracy. JPL currently has a laboratory to demonstrate this technology, which faces the same challenge as the MSWC project of producing two incoherent nearby sources. We developed Photonic Chips with multiple waveguides in Silicon Nitride for both projects to create incoherent single sources as close as 15um. In this paper, we present the concept application, the chips design, and the first results.

photonic chips↗

Does the International Space Station Leak DNA? Preliminary Results from the ISS External Microorganisms Payload

Existing crewed spacecraft like the ISS (International Space Station) leak by design. The ISS routinely releases gas to maintain life support systems and when astronauts exit the station to perform space walks. The chemical component of this leakage is well characterized, but the biological components are not. The ISS is not subject to planetary protection requirements, but planned missions to Mars will use similar systems and will be subject to planetary protection requirements. If detectable microorganisms are escaping through vents and or airlocks we may need to redesign our crewed habitats to minimize this type of contamination. To test the hypothesis that microorganisms from inside ISS are detectable on exterior surfaces an astronaut used the ISS External Microorganisms sampling kit (Rucker et al. 2018) to sample exterior surfaces of the ISS during an EVA (Extra Vehicular Activity) in January of 2025. These samples were returned to Earth for DNA extraction and sequencing. We successfully, extracted and sequenced bacterial, fungal and viral DNA from these samples that was not present in the negative controls. These results should help NASA refine the planetary protection requirements for crewed missions. Methods: The samples were collected using sterile, DNA free, buccal swabs (23 mm. diameter) housed in custom canisters. Each canister uses a 0.2 μm Teflon filter to maintain sterility as the caddy, holding 8 swabs moves in and out of vacuum. The astronaut sampled the: 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the Carbon Dioxide Removal Assembly vent, and 6) the Vacuum Exhaust System vent. The seventh swab was exposed to vacuum during the EVA without touching it to a surface. The eighth swab, a negative control, was not opened until the caddy returned to Earth. DNA was extracted from the swabs using a QIamp UCP Pathogen kit and prepared for sequencing on an Aviti (Element Biosciences) sequencer (Arslan et al. 2024). The resulting sequences were analyzed using the EDGE Bioinformatics platform (Li et al. 2017). The sequences were analyzed individually using tools like BLAST, GOTTCHA2, Kraken2, and PanGIA. The data were also assembled into metagenome assembled genomes) using tools like CONCOCT, MaxBin2 and MetaBAT2. Results: We successfully extracted and sequenced bacterial, archaeal, fungal and viral DNA from all seven samples. The handrail swab had the lowest number of reads (768,651) and the airlock thermal cover had the highest number of reads (8,819,230). These samples contain DNA from human associated bacteria (e.g. Crynebacterium riegelii ), fungi (.e.g. Penicillium rubens ), and viruses (e.g Alphapapillomavirus ). Conclusion: Preliminary interpretation suggest that the airlock and the space suits themselves are the largest sources of contaminant DNA. Most if not all of the DNA is from organisms known to be present inside the ISS. Vents attached to life support systems may be a lesser source of biological contamination. Further analysis should help NASA address planetary protection knowledge gaps for crewed missions.

Aaron B Regberg↗

Water-absorbing capacitor system for measuring relative humidity

A method and apparatus using a known water-absorbent polymer as a capacitor which is operated at a dc voltage for measuring relative humidity is presented. When formed as a layer between porous electrically-conductive electrodes and operated in an RC oscillator circuit, the oscillator frequency varies inversely with the partial pressure of the moisture to be measured. In a preferred embodiment, the capacitor is formed from Nafion and is operated at a low dc voltage with a resistor as an RC circuit in an RC oscillator. At the low voltage, the leakage current is proper for oscillation over a satisfactory range. The frequency of oscillation varies in an essentially linear fashion with relative humidity which is represented by the moisture being absorbed into the Nafion. The oscillation frequency is detected by a frequency detector.

Laue, Eric G.↗