Search NASA⌕ Search

SEARCH · Search NASA

Results for “lidar error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Advanced Water Vapor Lidar Detection System

In the present water vapor lidar system, the detected signal is sent over long cables to a waveform digitizer in a CAMAC crate. This has the disadvantage of transmitting analog signals for a relatively long distance, which is subjected to pickup noise, leading to a decrease in the signal to noise ratio. Generally, errors in the measurement of water vapor with the DIAL method arise from both random and systematic sources. Systematic errors in DIAL measurements are caused by both atmospheric and instrumentation effects. The selection of the on-line alexandrite laser with a narrow linewidth, suitable intensity and high spectral purity, and its operation at the center of the water vapor lines, ensures minimum influence in the DIAL measurement that are caused by the laser spectral distribution and avoid system overloads. Random errors are caused by noise in the detected signal. Variability of the photon statistics in the lidar return signal, noise resulting from detector dark current, and noise in the background signal are the main sources of random error. This type of error can be minimized by maximizing the signal to noise ratio. The increase in the signal to noise ratio can be achieved by several ways. One way is to increase the laser pulse energy, by increasing its amplitude or the pulse repetition rate. Another way, is to use a detector system with higher quantum efficiency and lower noise, on the other hand, the selection of a narrow band optical filter that rejects most of the day background light and retains high optical efficiency is an important issue. Following acquisition of the lidar data, we minimize random errors in the DIAL measurement by averaging the data, but this will result in the reduction of the vertical and horizontal resolutions. Thus, a trade off is necessary to achieve a balance between the spatial resolution and the measurement precision. Therefore, the main goal of this research effort is to increase the signal to noise ratio by a factor of 10 over the current system, using a newly evaluated, very low noise avalanche photo diode detector and constructing a 10 MHz waveform digitizer which will replace the current CAMAC system.

Elsayed-Ali, Hani↗

Airborne Lidar-Based Estimates of Tropical Forest Structure in Complex Terrain: Opportunities and Trade-Offs for REDD+

Background: Carbon stocks and fluxes in tropical forests remain large sources of uncertainty in the global carbon budget. Airborne lidar remote sensing is a powerful tool for estimating aboveground biomass, provided that lidar measurements penetrate dense forest vegetation to generate accurate estimates of surface topography and canopy heights. Tropical forest areas with complex topography present a challenge for lidar remote sensing. Results: We compared digital terrain models (DTM) derived from airborne lidar data from a mountainous region of the Atlantic Forest in Brazil to 35 ground control points measured with survey grade GNSS receivers. The terrain model generated from full-density (approx. 20 returns/sq m) data was highly accurate (mean signed error of 0.19 +/-0.97 m), while those derived from reduced-density datasets (8/sq m, 4/sq m, 2/sq m and 1/sq m) were increasingly less accurate. Canopy heights calculated from reduced-density lidar data declined as data density decreased due to the inability to accurately model the terrain surface. For lidar return densities below 4/sq m, the bias in height estimates translated into errors of 80-125 Mg/ha in predicted aboveground biomass. Conclusions: Given the growing emphasis on the use of airborne lidar for forest management, carbon monitoring, and conservation efforts, the results of this study highlight the importance of careful survey planning and consistent sampling for accurate quantification of aboveground biomass stocks and dynamics. Approaches that rely primarily on canopy height to estimate aboveground biomass are sensitive to DTM errors from variability in lidar sampling density.

Airborne lidar↗

Improved simulation of aerosol, cloud, and density measurements by shuttle lidar

Data retrievals are simulated for a Nd:YAG lidar suitable for early flight on the space shuttle. Maximum assumed vertical and horizontal resolutions are 0.1 and 100 km, respectively, in the boundary layer, increasing to 2 and 2000 km in the mesosphere. Aerosol and cloud retrievals are simulated using 1.06 and 0.53 microns wavelengths independently. Error sources include signal measurement, conventional density information, atmospheric transmission, and lidar calibration. By day, tenuous clouds and Saharan and boundary layer aerosols are retrieved at both wavelengths. By night, these constituents are retrieved, plus upper tropospheric, stratospheric, and mesospheric aerosols and noctilucent clouds. Density, temperature, and improved aerosol and cloud retrievals are simulated by combining signals at 0.35, 1.06, and 0.53 microns. Particlate contamination limits the technique to the cloud free upper troposphere and above. Error bars automatically show effect of this contamination, as well as errors in absolute density nonmalization, reference temperature or pressure, and the sources listed above. For nonvolcanic conditions, relative density profiles have rms errors of 0.54 to 2% in the upper troposphere and stratosphere. Temperature profiles have rms errors of 1.2 to 2.5 K and can define the tropopause to 0.5 km and higher wave structures to 1 or 2 km.

Russell, P. B.↗

Evaluation of airborne lidar wind measurements

The verification of the Doppler lidar wind measurement is continued. The in situ measurements on a 500 meter tall tower are used to check the lidar determined winds (flight 4), followed by other tests applied to the extensive data sets of flights 19 and 21. After checking for possible software errors in the processing programs, the inconsistency was not solved. The source of the errors appears to be the uncertainty in the calculation of the contribution of the aircraft motion to the lidar measured line of sight speed. Possible techniques for estimating the aircraft motion errors from the aircraft data are investigated.

Carroll, J. J.↗

A comparison of dustsonde and LIDAR measurements of stratospheric aerosols

This paper describes the results and analysis of an experiment to compare the stratospheric aerosol profiles as measured by a balloon-borne in situ particle counter and by the backscattered light from a ground-based laser radar (LIDAR) operating at a wavelength of 6943 A. The profile comparison agrees within the experimental errors for particles with radii greater than 0.25 micrometer and for altitudes between 15 and 28 kilometers. Following the calibration tests, the LIDAR was used to monitor the stratospheric aerosols at Hampton, Virginia. Enhanced backscatter appeared sporadically in November and December of 1974 over Hampton; scattering ratios averaged over altitude increments of 450 meters range from 1.10 at 20 kilometers in early November to 3.3 at 17 kilometers on December 18. The source of this enhanced backscattering is attributed to the aerosols associated with the eruption of the Fuego volcano in Guatemala in mid-October.

Remsberg, E. E.↗

Performance of Doppler Lidar Velocity and Range Sensor Operating in Highly Dynamic Environments

The operation of a coherent Doppler lidar, developed by NASA for missions to planetary bodies, is analyzed and its projected performance is described. The lidar transmits three laser beams at different but fixed directions and measures line-of-sight range and velocity along each beam. The three line-of-sight measurements are then combined in order to determine the three components of the vehicle velocity vector and its altitude relative to the ground. Operating from over five kilometers altitude, the NDL provides velocity and range data with a few cm/sec and a few meters precision, respectively, depending on the vehicle dynamics. This paper explains the sources of measurements error and analyzes the impacts of vehicle dynamics on the lidar performance.

Doppler Lidar↗

Analysis of Navigation Doppler Lidar performance for Moon and Mars Landing

The operation of a coherent Doppler lidar, developed by NASA for missions to planetary bodies, is analyzed and its projected performance is described. The lidar transmits three laser beams at different but fixed directions and measures line-of-sight range and velocity along each beam. The three line-of-sight measurements are then combined in order to determine the three components of the vehicle velocity vector and its altitude relative to the ground. Operating from over five kilometers altitude, the NDL provides velocity and range data with a few cm/sec and a few meters precision, respectively, depending on the vehicle dynamics. This paper explains the sources of measurement error and analyzes the impact of vehicle dynamics on the lidar performance.

Farzin Amzajerdian↗

Cumulus convection as observed from an airborne infrared radiometer

The implementation of high resolution passive radiative remote sensing of the cloudiness volume in the atmospheric window between 10.5-12.5 microns is described. Airborne radiometers, the NASA/Cloud Top Scanner, were used to obtain radiances during several passages over two merging cumulus clouds, with the data being converted into equivalent blackbody temperatures. Data were also gathered in the 0.55-0.70 micron visible bands as part of the SESAME-79 experiment. The number of points observed in the IR channel were adjusted to account for the viewing angle and areal extents were calculated. A relationship was assumed to exist between the brightness temperatures of the cloud surface and the level of cloudiness at a given atmospheric altitude. Further measurements with lidar scans are indicated in order to reduce the error levels associated with the method.

Szejwach, G.↗

The 27-28 October 1986 FIRE IFO Cirrus Case Study: Cloud Optical Properties Determined by High Spectral Resolution Lidar

During the First ISCCP Region Experiment (FIRE) cirrus intensive field observation (IFO) the High Spectral Resolution Lidar was operated from a roof top site on the University of Wisconsin-Madison campus. Because the HSRL technique separately measures the molecular and cloud particle backscatter components of the lidar return, the optical thickness is determined independent of particle backscatter. This is accomplished by comparing the known molecular density distribution to the observed decrease in molecular backscatter signal with altitude. The particle to molecular backscatter ratio yields calibrated measurements of backscatter cross sections that can be plotted ro reveal cloud morphology without distortion due to attenuation. Changes in cloud particle size, shape, and phase affect the backscatter to extinction ratio (backscatter-phase function). The HSRL independently measures cloud particle backscatter phase function. This paper presents a quantitative analysis of the HSRL cirrus cloud data acquired over an approximate 33 hour period of continuous near zenith observations. Correlations between small scale wind structure and cirrus cloud morphology have been observed. These correlations can bias the range averaging inherent in wind profiling lidars of modest vertical resolution, leading to increased measurement errors at cirrus altitudes. Extended periods of low intensity backscatter were noted between more strongly organized cirrus cloud activity. Optical thicknesses ranging from 0.01-1.4, backscatter phase functions between 0.02-0.065 sr (exp -1) and backscatter cross sections spanning 4 orders of magnitude were observed. the altitude relationship between cloud top and bottom boundaries and the cloud optical center altitude was dependent on the type of formation observed Cirrus features were observed with characteristic wind drift estimated horizontal sizes of 5-400 km. The clouds frequently exhibited cellular structure with vertical to horizontal dimension ratios of 1:5-1:1.

Grund, C. J.↗

A Deployable Primary Mirror for Space Telescopes

NASA Langley Research Center, Composite Optics, Inc., and Nyma/ADF have developed jointly a deployable primary mirror for space telescopes that combines over five years of research on deployment of optical-precision structures and over ten years of development of fabrication techniques for optical-precision composite mirror panels and structures. The deployable mirror is directly applicable to a broad class of non-imaging "lidar" (Light direction and ranging) telescopes whose figure-error requirements are in the range of one to ten microns RMS. Furthermore, the mirror design can be readily modified to accommodate imaging-quality reflector panels and active panel-alignment control mechanisms for application to imaging telescopes. The present paper: 1) describes the deployable mirror concept; 2) explains the status of the mirror development; and 3) provides some technical specifications for a 2.55- m-diameter, proof-of-concept mirror.

Lake, Mark S.↗

A Deployable Primary Mirror for Space Telescopes

NASA Langley Research Center, Composite Optics, Inc., and Nyma/ADF have developed jointly a deployable primary mirror for space telescopes that combines over five years of research on deployment of optical-precision structures and over ten years of development of fabrication techniques for optical-precision composite mirror panels and structures. The deployable mirror is directly applicable to a broad class of non-imaging "lidar" (light direction and ranging) telescopes whose figure-error requirements are in the range of one to ten microns RMS. Furthermore, the mirror design can be readily modified to accommodate imaging-quality reflector panels and active panel-alignment control mechanisms for application to imaging telescopes. The present paper: 1) describes the deployable mirror concept; 2) explains the status of the mirror development; and 3) provides some technical specifications for a 2.55-m-diameter, proof-of-concept mirror.

Lake, Mark S.↗

Airborne Measurements of Atmospheric Pressure made Using an IPDA Lidar Operating in the Oxygen A-Band

We report airborne measurements of atmospheric pressure made using an integrated path differential absorption (IPDA) lidar that operates in the oxygen A-band near 765 nm. Remote measurements of atmospheric temperature and pressure are needed for NASA s Active Sensing of CO2 Emissions Over Nights, Days, and Seasons (ASCENDS) mission to measure atmospheric CO2. Accurate measurements of tropospheric CO2 on a global scale are very important in order to better understand its sources and sinks and to improve our predictions of climate change. The goal of ASCENDS is to determine the CO2 dry mixing ratio with lidar measurements from space at a level of ~1 ppm. Analysis to date shows that with current weather models, measurements of both the CO2 column density and the column density of dry air are needed. Since O2 is a stable molecule that uniformly mixed in the atmosphere, measuring O2 absorption in the atmosphere can be used to infer the dry air density. We have developed an airborne (IPDA) lidar for Oxygen, with support from the NASA ESTO IIP program. Our lidar uses DFB-based seed laser diodes, a pulsed modulator, a fiber laser amplifier, and a non-linear crystal to generate wavelength tunable 765 nm laser pulses with a few uJ/pulse energy. The laser pulse rate is 10 KHz, and average transmitted laser power is ~20 mW. Our lidar steps laser pulses across a selected line O2 doublet near 764.7 nm in the Oxygen A-band. The direct detection lidar receiver uses a 20 cm diameter telescope, a Si APD detector in Geiger mode, and a multi-channel scalar to detect and record the time resolved laser backscatter in 40 separate wavelength channels. Subsequent analysis is used to estimate the transmission line shape of the doublet for the laser pulses reflected from the ground. Ground based data analysis allows averaging from 1 to 60 seconds to increase SNR in the transmission line shape of the doublet. Our retrieval algorithm fits the expected O2 lineshapes against the measurements and determines the atmospheric pressure by minimizing the error between the observations and model. We first demonstrated our airborne lidar during flights during summer 2010. We made several improvements and made measurements during the Ascends flights during July 2011. More information about the technique, lidar instrument, airborne measurements, and pressure estimates will be described in the presentation.

Riris, Haris↗

A Deployable Primary Mirror for Space Telescopes

NASA Langley Research Center, Composite Optics, Inc., and Nyma/ADF have developed jointly a deployable primary mirror for space telescopes that combines over five years of research on deployment of optical-precision structures and over ten years of development of fabrication techniques for optical-precision composite mirror panels and structures. The deployable mirror is directly applicable to a broad class of non-imaging "lidar" (light direction a nd ranging) telescopes whose figure-error requirements are in the range of one to ten microns RMS. Furthermore, the mirror design can be readily modified to accommodate imaging-quality reflector panels and active panel-alignment control mechanisms for application to imaging telescopes. The present paper: 1) describes the deployable mirror concept; 2) explains the status of the mirror development; and 3) provides some technical specifications for a 2.55- m-diameter, proof-of-concept mirror. Keywords: precision deployment, hinge joint, latch joint, deployable structures, fabrication, space telescopes, optical instruments, microdynamics.

Lake, Mark S.↗

Surface Irradiances of Edition 4.0 Clouds and the Earth's Radiant Energy System (CERES) Energy Balanced and Filled (EBAF) Data Product

The algorithm to produce the Clouds and the Earth’s Radiant Energy System (CERES) Edition 4.0 (Ed4) Energy Balanced and Filled (EBAF)-surface data product is explained. The algorithm forces computed topof- atmosphere (TOA) irradiances to match with Ed4 EBAF-TOA irradiances by adjusting surface, cloud, and atmospheric properties. Surface irradiances are subsequently adjusted using radiative kernels. The adjustment process is composed of two parts: bias correction and Lagrange multiplier. The bias in temperature and specific humidity between 200 and 500 hPa used for the irradiance computation is corrected based on observations by Atmospheric Infrared Sounder (AIRS). Similarly, the bias in the cloud fraction is corrected based on observations by Cloud–Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) and CloudSat. Remaining errors in surface, cloud, and atmospheric properties are corrected in the Lagrange multiplier process. Ed4 global annual mean (January 2005 through December 2014) surface net shortwave (SW) and longwave (LW) irradiances increase by 1.3Wm22 and decrease by 0.2Wm22, respectively, compared to EBAF Edition 2.8 (Ed2.8) counterparts (the previous version), resulting in an increase in net SW 1LWsurface irradiance of 1.1Wm22. The uncertainty in surface irradiances over ocean, land, and polar regions at various spatial scales are estimated. The uncertainties in all-sky global annual mean upward and downward shortwave irradiance are 3 and 4Wm22, respectively, and the uncertainties in upward and downward longwave irradiance are 3 and 6Wm22, respectively. With an assumption of all errors being independent, the uncertainty in the global annual mean surface LW 1 SW net irradiance is 8Wm22.

Kato, Seiji↗

Analysis of differential absorption lidar from the Space Shuttle

A parametric analysis of the Shuttle-borne differential absorption lidar concept for the measurement of atmospheric trace constituent profiles in the nadir viewing mode is presented. The criterion of an optimum constituent optical depth is developed and applied to generate estimates of range resolved measurement errors. These errors emphasize the fundamental limitations for establishing the feasibility of range-resolved differential absorption lidar measurements from Shuttle. With current lidar system technology, atmospheric backscatter density profiles may be adequately determined up to about 60-km altitude at the doubled-ruby wavelength, 3472 A, for a 1-J/pulse laser and a 1-sq m receiver. Potential range-resolved measurements of stratospheric and mesospheric trace constituents by differential absorption from Shuttle altitudes are limited to H2O, CH4, N2O, O3, and CO, species which can be more easily measured by passive limb viewing techniques. Range-resolved water vapor data for the lower troposphere may be obtained with accuracies which would be competitive with those from passive sensors.

Remsberg, E. E.↗

High-resolution processing of long-pulse-lidar data

The purpose of this work is to demonstrate the performance of the Fourier-deconvolution technique developed to improve the resolution of the long-pulse coherent lidar power profile, and to take into account the multiplicative fluctuations. The behavior of the error due to the power fluctuations and a method to reduce it are analyzed theoretically and simulated numerically. A processing of real data obtained from the National Oceanic and Atmospheric Administration (NOAA) ground-based Doppler lidar is also presented. Similar problems were investigated using a different approach based on introducing a correction function to the lidar equation.

Gurdev, L. L.↗

Test Bed Doppler Wind Lidar and Intercomparison Facility At NASA Langley Research Center

State of the art 2-micron lasers and other lidar components under development by NASA are being demonstrated and validated in a mobile test bed Doppler wind lidar. A lidar intercomparison facility has been developed to ensure parallel alignment of up to 4 Doppler lidar systems while measuring wind. Investigations of the new components; their operation in a complete system; systematic and random errors; the hybrid (joint coherent and direct detection) approach to global wind measurement; and atmospheric wind behavior are planned. Future uses of the VALIDAR (VALIDation LIDAR) mobile lidar may include comparison with the data from an airborne Doppler wind lidar in preparation for validation by the airborne system of an earth orbiting Doppler wind lidar sensor.

Kavaya, Michael J.↗

Test Bed Doppler Wind Lidar and Intercomparison Facility At NASA Langley Research Center

State of the art 2-micron lasers and other lidar components under development by NASA are being demonstrated and validated in a mobile test bed Doppler wind lidar. A lidar intercomparison facility has been developed to ensure parallel alignment of up to 4 Doppler lidar systems while measuring wind. Investigations of the new components; their operation in a complete system; systematic and random errors; the hybrid (joint coherent and direct detection) approach to global wind measurement; and atmospheric wind behavior are planned. Future uses of the VALIDAR (VALIDation LIDAR) mobile lidar may include comparison with the data from an airborne Doppler wind lidar in preparation for validation by the airborne system of an earth orbiting Doppler wind lidar sensor.

Kavaya, Michael J.↗