Search NASA⌕ Search

SEARCH · Search NASA

Results for “light shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Evaluation of light collection from highly scattering media using wavelength-shifting fibers

Opaque scintillators are designed to have a short scattering length such that scintillation photons are probabilistically confined to a small region of space about their origin. The benefit of this feature is that information on the interaction event topology can be recorded with greater fidelity than in traditional highly transparent media with sensors at large distances from the light production region. Opaque scintillator detectors rely on wavelength-shifting fibers to extract the scintillation light; however, the efficiency of light collection has not yet been directly measured in experiment. We measured the efficiency of light collection as a function of the optical parameters of an opaque liquid and the distance from the origin of the light to the fiber. We use the experimental data to validate a Monte Carlo model of light transport and collection and discuss a simple diffusion model that reproduces the results of Monte Carlo simulation with high fidelity. Furthermore, this combination of validated models has the potential for use in predictions of performance in various designs of future opaque scintillator detectors such as LiquidO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon phase-space dynamics in a plasma wakefield accelerator

Frequency up-shifting of laser light in a beam-driven plasma wakefield has the potential to provide high-intensity sources of short wavelength radiation. Simulations have demonstrated that a laser pulse can undergo large frequency shifts, limited only by the drive beam energy, when the plasma density is tailored to match the accelerating phase of the wake to the group velocity of the pulse. Here, we study the dynamical evolution of photons in the 1D1P phase-space vicinity of the plasma wake-phase matching condition. Numerical calculations using a photon kinetic model are validated by direct comparison with 1D and quasi-3D particle-in-cell simulations. These calculations form the basis of a linear theory of the photon dynamics which reveals several important results, including scalings for the properties of the witness pulse and a self-similar solution for the photon phase-space dynamics. One prediction of the analytic theory is that the pulse can be compressed indefinitely, though the amount of compression would ultimately be limited by practical constraints. These results suggest that photon acceleration can provide a novel source of sub-femtosecond, short wavelength radiation.

XUV generation↗

SO2 Spectroscopy with A Tunable UV Laser

A portion of the fluorescence spectrum of SO2 has been studied using a narrow wavelength doubled dye laser as the exciting source. One purpose of this study is to evaluate the use of SO2 resonance re-emission as a probe of SO2 in the atmosphere. When the SO2 is excited by light at 300.2 nm, for example, a strong reemission peak is observed which is Stokes-shifted from the incident light wavelength by the usual Raman shift (the VI symmetric vibration frequency 1150.5/cm ). The intensity of this peak is sensitive to small changes (.01 nm) in the incident wavelength. Measurements of the N2 quenching and self quenching of this re-emission have been obtained. Preliminary analysis of this data indicates that the quenching is weak but not negligible. The dye laser in our system is pumped by a pulsed N2 laser. Tuning 'and spectral narrowing are accomplished using a telescope-echelle grating combination. In a high power configuration the resulting pulses have a spectral width of about 5 x 10(exp -3) nm and a time duration of about 6 nsec. The echelle grating is rotated by a digital stepping motor, such that each step shifts the wavelength by 6 x 10(exp -4) nm. In addition to the tunable, narrow wavelength uv source and spectral analysis of the consequent re-emission, the system also provides time resolution of the re-emitted light to 6 nsec resolution. This capability is being used to study the lifetime of low pressure S02 fluorescence at different wavelengths and pressures.

Morey, W. W.↗

Optical gyroscope system

Light beams pass in opposite directions through a single mode fiber optic wave guide that extends in a circle or coil in an optical gyroscope system which measures the rotation rate of the coil by measuring the relative phase shifts of the beams by interferometric techniques. Beam splitting and phase shifting of the light are facilitated by utilizing brief pulses of light and by using light-controlling devices which are operated for a brief time only when the light pulse passes in one direction through the device but not at a different time when the pulse is passing in the opposite direction through the device. High accuracy in rotation measurement is achieved at both very slow and very fast rotation rates, by alternately operating the system so that at zero rotation the interfering waves are alternately 90 out of phase and in phase. Linear polarization of the light beams is maintained by coiling the full length of the optic fiber in a single plane.

Goss, W. C.↗

Human circadian pacemaker is sensitive to light throughout subjective day without evidence of transients

Fifty-six resetting trials were conducted across the subjective day in 43 young men using a three-cycle bright-light (approximately 10,000 lx). The phase-response curve (PRC) to these trials was assessed for the presence of a "dead zone" of photic insensitivity and was compared with another three-cycle PRC that had used a background of approximately 150 lx. To assess possible transients after the light stimulus, the trials were divided into 43 steady-state trials, which occurred after several baseline days, and 13 consecutive trials, which occurred immediately after a previous resetting trial. We found that 1) bright light induces phase shifts throughout subjective day with no apparent dead zone; 2) there is no evidence of transients in constant routine assessments of the fitted temperature minimum 1-2 days after completion of the resetting stimulus; and 3) the timing of background room light modulates the resetting response to bright light. These data indicate that the human circadian pacemaker is sensitive to light at virtually all circadian phases, implying that the entire 24-h pattern of light exposure contributes to entrainment.

NASA Discipline Regulatory Physiology↗

Constraining the particle-scale diversity of black carbon light absorption using a unified framework

Abstract. Atmospheric black carbon (BC), the strongest absorber of visible solar radiation in the atmosphere, manifests across a wide spectrum of morphologies and compositional heterogeneity. Phenomenologically, the distribution of BC among diverse particles of varied composition gives rise to enhancement of its light absorption capabilities by over twofold in comparison to that of nascent or unmixed homogeneous BC. This situation has challenged the modeling community to consider the full complexity and diversity of BC on a per-particle basis for accurate estimation of its light absorption. The conventionally adopted core–shell approximation, although computationally inexpensive, is inadequate not only in estimating but also capturing absorption trends for ambient BC. Here we develop a unified framework that encompasses the complex diversity in BC morphology and composition using a single metric, the phase shift parameter (ρBC), which quantifies how much phase shift the incoming light waves encounter across a particle compared to that in its absence. We systematically investigate variations in ρBC across the multi-space distribution of BC morphology, mixing state, mass, and composition as reported by field and laboratory observations. We find that ρBC>1 leads to decreased absorption by BC, which explains the weaker absorption enhancements observed in certain regional BC compared to laboratory results of similar mixing state. We formulate universal scaling laws centered on ρBC and provide physics-based insights regarding core–shell approximation overestimating BC light absorption. We conclude by packaging our framework in an open-source Python application to facilitate community-level use in future BC-related research. The package has two main functionalities. The first functionality is for forward problems, wherein experimentally measured BC mixing state and assumed BC morphology are input, and the aerosol absorption properties are output. The second functionality is for inverse problems, wherein experimentally measured BC mixing state and absorption are input, and the morphology of BC is returned. Further, if absorption is measured at multiple wavelengths, the package facilitates the estimation of the imaginary refractive index of coating materials by combining the forward and inverse procedures. Our framework thus provides a computationally inexpensive source for calculation of absorption by BC and can be used to constrain light absorption throughout the atmospheric lifetime of BC.

54 ENVIRONMENTAL SCIENCES↗

Pioneer 10 observations of the Beta Cephei stars Gamma Pegasi and Delta Ceti

The results of analyzing broad-band Pioneer 10 photometric observations of the low-amplitude pulsating Beta Cephei stars Gamma Pegasi and Delta Ceti are reported. Periods and light curve amplitudes of 3.649 + or - 0.020 hr, 0.05 + or - 0.02 mag for Gamma Peg and 3.869 + or - 0.020 hr, 0.13 + or - 0.02 mag for Delta Ceti are obtained; a power spectrum analysis of the data reveals no other periods. No evidence is found for a phase shift between the light curve maxima in the UV and visible regions. The observed amplitudes combined with published visual and near-UV data suggest a flux and temperature variability of about 200 solar luminosities and 250 K for Gamma Peg and about 600 solar luminosities and 450 K for Delta Cet. These results are compared with others obtained with satellite and ground-based instrumentation.

Peters, Geraldine J.↗

Fast Light-Sheet Scanner

Optomechanical apparatus maintains sheet of pulsed laser light perpendicular to reference axis while causing sheet of light to translate in oscillatory fashion along reference axis. Produces illumination for laser velocimeter in which submicrometer particles entrained in flow illuminated and imaged in parallel planes displaced from each other in rapid succession. Selected frequency of oscillation range upward from tens of hertz. Rotating window continuously shifts sheet of light laterally while maintaining sheet parallel to same plane.

Hunter, William W., Jr.↗

Planar Particle Imaging and Doppler Velocimetry System and Method

A planar velocity measurement system (100) is operative to measure all three velocity components of a flowing fluid (106) across an illuminated plane (108) using only a single line of sight. The fluid flow is seeded with small particles which accurately follow the flow field fluctuations. The seeded flow field is illuminated with pulsed laser light source (102) and the positions of the particles in the flow are recorded on CCD cameras (122,124). The in-plane velocities are measured by determining the in-plane particle displacements. The out-of-plane velocity component is determined by measuring the Doppler shift of the light scattered by the particles. Both gas and liquid velocities can be measured, as well as two-phase flows.

Wernet, Mark P.↗

Laser Light Scattering Diagnostic for Measurement of Flow Velocity in Vicinity of Propagating Shock Waves

A laser light scattering diagnostic for measurement of dynamic flow velocity at a point is described. The instrument is being developed for use in the study of propagating shock waves and detonation waves in pulse detonation engines under development at the NASA Glenn Research Center (GRC). The approach uses a Fabry-Perot interferometer to measure the Doppler shift of laser light scattered from small (submicron) particles in the flow. The high-speed detection system required to resolve the transient response as a shock wave crosses the probe volume uses fast response photodetectors, and a PC based data acquisition system. Preliminary results of measurements made in the GRC Mach 4, 10 by 25 cm supersonic wind tunnel are presented. Spontaneous condensation of water vapor in the flow is used as seed. The tunnel is supplied with continuous air flow at up to 45 psia and the flow is exhausted into the GRC laboratory-wide altitude exhaust system at pressures down to 0.3 psia.

Seasholtz, Richard G.↗

Quantum enhanced magneto-optical microscopy and spectroscopy

A system comprising a nonlinear medium (NLM), an optical transduction module, a dual homodyne detector and a processor is provided. The NLM receives at least a pump beam and issues the pump, probe and conjugate beams, where the beams are linearly polarized. Optics route the probe, the conjugate or both beams to the sample. The sample imparts polarization rotation to light that interacts therewith. The optical transduction module imparts to the interacted light an optical phase shift that is a 1:1 transduction of the polarization rotation, where at least one of the probe light or the conjugate light carries the imparted optical phase shift. The processor obtains the optical-phase shift based on respective detection signals from the dual homodyne detector and determines, based on the obtained optical-phase shift, at least one of a Faraday polarization rotation, a Kerr polarization rotation or a spin noise spectrum.

Lawrie, Benjamin J.↗

Performance of Hamamatsu VUV4 SiPMs for detecting liquid argon scintillation

Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is technically challenging. In this paper, we characterized the performance of Hamamatsu VUV4 silicon photomultipliers (SiPMs) for detecting VUV argon scintillation light without wavelength shifting. Using a customized cryogenic amplifier design, we operated two models of VUV4 SiPMs inside liquid argon and thoroughly examined their direct sensitivities to liquid argon scintillation. In addition to describing their cryogenic performance, we measured a photon detection efficiency of 14.7 +1.1 -2.4 % and 17.2 +1.6 -3.0 % at 128 nm for these two VUV4 models for operation at 4 V of overvoltage, with the main uncertainty arising from the SiPM reflectivity for VUV light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Hamamatsu VUV4 SiPM Performance for Liquid Argon Scintillation

Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is technically challenging. In this article, we characterized the performance of Hamamatsu VUV4 silicon photomultipliers (SiPMs) for detecting VUV argon scintillation light without wavelength shifting. Here, using a customized cryogenic amplifier design, we operated two models of VUV4 SiPMs inside liquid argon and thoroughly examined their direct sensitivities to liquid argon scintillation. In addition to describing their cryogenic performance, we measured a photon detection efficiency of 14.7+1.1–2.4% and 17.2+1.6–3.0% at 128 nm for these two VUV4 models for operation at 4 V of overvoltage, with the main uncertainty arising from the SiPM reflectivity for VUV light.

Pershing, Teal↗

Ultraviolet spectroscopy of R Coronae Borealis

Observations of the hydrogen-deficient supergiant R CrB were obtained with the IUE over an interval of 54 days in order to study the nature of this star's irregular, small-amplitude variations in light. By chance, the series of observations coincided with a dip in the light intermediate between the normal fluctuations and the deep declines associated with the formation of an obscuring dust cloud. High-resolution spectra have been used to search for radial velocity variations, while low-resolution spectra yield ultraviolet light curves down to 1810 A. Both types of spectra have been analyzed for indications of temperature changes. It is found that a combination of photospheric temperature variation and variable extinction is necessary to account for the details of the observations. A simple, ad hoc, periodic model is presented in which the amount of obscuring dust varies in proportion to the drop in temperature, but at a later time, reproduces the wavelength dependence of both the amplitudes and phase shifts of the light curves. The radial velocities are consistent with pulsation being responsible for the temperature variation.

Holm, A. V.↗

Suppressing Polaronic Defect–Photocarrier Interaction in Halide Perovskites by Pre-distorting Its Lattice

In halide perovskites, photocarriers can have strong polaronic interactions with point defects. For iodide-deficient MAPbI 3 , we found that the Fermi level can shift significantly by 0.6–0.7 eV upon light illumination. This energy level shift is accompanied by the formation of deep electron traps. These experimental observations are consistent with the formation of a Pb–Pb dimer when photoexcited electrons are trapped at an iodide vacancy. Interestingly, we found that this polaronic interaction is suppressed when a portion of MA + cations is replaced by smaller Cs + ions. Density functional theory calculations reveal that Cs-doping can reduce the distance between two Pb atoms across an iodide vacancy, even without electron trapping. The predistortion of the lattice induced by cation replacement resembles the Pb–Pb dimer formed by electron trapping at the defect site, which explains the suppression of light-induced effects observed in the experiment. Furthermore, our finding unveils a counterintuitive strategy to enhance the photostability of halide perovskites by preintroducing distortions into its lattice.

14 SOLAR ENERGY↗

Precision gyroscope from the helicity of light

We describe a gyroscope that measures rotation based on the effects of the rotation on the polarization of light. Rotation induces a differential phase shift in the propagation of left- and right-circularly polarized light and this phase shift can be measured in suitably designed interferometric setups. The signal in this setup is independent of the frequency of light, unlike various sources of noise such as vibrations, which cause phase shifts that depend on the frequency. Such vibrations are the practical limit on the sensitivity of conventional Sagnac-style optical interferometers that are typically used as gyroscopes. In the proposed setup, one can potentially mitigate this source of noise by simultaneously using two (or more) sources of light that have different frequencies. The signal in this setup scales with the total storage time of the light. Due to its frequency independence, it is thus most optimal to measure the signal using superconducting radio-frequency systems where the high finesse of the available cavities enables considerably longer storage times than is possible in an optical setup.

47 OTHER INSTRUMENTATION↗

Surface Effects on Anisotropic Photoluminescence in One‐Dimensional Organic Metal Halide Hybrids

1D organic metal halide hybrids (OMHHs) exhibit strongly anisotropic optical properties, highly efficient light emission, and large Stokes shift, holding promise for novel photodetection and lighting applications. However, the fundamental mechanisms governing their unique optical properties and in particular the impacts of surface effects are not understood. Herein, 1D C 4 N 2 H 14 PbBr 4 by polarization‐dependent time‐averaged and time‐resolved photoluminescence (TRPL) spectroscopy, as a function of photoexcitation energy, is investigated. Surprisingly, it is found that the emission under photoexcitation polarized parallel to the 1D metal halide chains can be either stronger or weaker than that under perpendicular polarization, depending on the excitation energy. The excitation‐energy‐dependent anisotropic emission is attributed to fast surface recombination, supported by first‐principles calculations of optical absorption in this material. The fast surface recombination is directly confirmed by TRPL measurements, when the excitation is polarized parallel to the chains. The comprehensive studies provide a more complete picture for a deeper understanding of the optical anisotropy in 1D OMHHs.

36 MATERIALS SCIENCE↗