Flight loads measurements obtained from calibrated strain-gage bridges mounted externally on the skin of a low-aspect-ratio wing

Flight-test measurements of wingloads (shear, bending moment, and torque) were obtained by means of strain-gage bridges mounted on the exterior surface of a low-aspect-ratio, thin, swept wing which had a structural skin, full-depth honeycomb core, sandwich construction. Details concerning the strain-gage bridges, the calibration procedures used, and the flight-test results are presented along with some pressure measurements and theoretical calculations for comparison purposes.

Eckstrom, C. V.↗

An instrumented fastener for shear force measurements in joints

A preliminary investigation has been conducted on instrumented fasteners for use as sensors to measure the shear loads transmitted by individual fasteners installed in double-splice joints. Calibration and load verification tests were conducted for instrumented fasteners installed at three fastener torque levels. Results from calibration tests show that the shear strains obtained from the instrumented fasteners vary linearly with the applied load and that the instrumented fasteners can be effectively used to measure shear loads transmitted by individual fasteners installed in double-splice joints. Tests were also conducted with three instumented fasteners installed in a typical double-splice joint. The test results showed that the load distribution between individual fasteners is dependent on the location of the fastener in the joint and the fastener torque level.

Sawyer, J. W.↗

Evaluation of a load cell model for dynamic calibration of the rotor systems research aircraft

The Rotor Systems Research Aircraft uses load cells to isolate the rotor/transmission system from the fuselage. An analytical model of the relationship between applied rotor loads and the resulting load cell measurements is derived by applying a force-and-moment balance to the isolated rotor/transmission system. The model is then used to estimate the applied loads from measured load cell data, as obtained from a ground-based shake test. Using nominal design values for the parameters, the estimation errors, for the case of lateral forcing, were shown to be on the order of the sensor measurement noise in all but the roll axis. An unmodeled external load appears to be the source of the error in this axis.

Duval, R. W.↗

Load Schedule Design Improvements for the Calibration of NASA's Semi-span Balances

Improvements of the load schedule design for the calibration of NASA's semi-span balances are discussed. These improvements became possible after a minor hardware change was made to Calspan's Large Load Rig. This change moves normal and axial force load points 12 inches closer to the balance moment center. Resulting data quality improvements are significant because Calspan's Large Load Rig cannot currently apply forces at the balance moment center of a semi-span balance. Now, the supported set of rolling and yawing moment arms is 28 inches, 38 inches, and 48 inches. Consequently, the new load schedule design better supports expected normal and axial force locations on semi-span models that are tested in the NASA Ames 11-ft Transonic Wind Tunnel. In addition, estimates of the primary sensitivities of the normal force, axial force, rolling moment, and yawing moment have become more accurate as the applied normal and axial forces have moved closer to the balance moment center. Fundamental moment arm range requirements and Calspan's hardware updates are discussed in detail. In addition, calibration analysis results of NASA's ARC30K semi-span balance are presented to illustrate benefits of the hardware changes.

wind tunnel test↗

Comparison of two Calibrations of NASA's MC60 Five-component Semi-span Balance

Two separate manual calibrations of NASA’s MC60 five–component semi–span balance were compared. The calibrations were performed in 1999 and 2019using CALSPAN Force Measurement System’s Large Load Rig. The Iterative Method was chosen as the load prediction algorithm and data reduction matrices were generated from both calibration data sets. Then, the applied calibration load schedules, the standard deviations of the calibration load residuals, the prime sensitivities of the five gages, and the maximum outputs at capacity of the five gages were compared. In addition, the calibration data of 1999 was used as check load data for the data reduction matrix that was obtained from the 2019 data. Overall, the agreement between the data analysis results is very good considering the facts that two different load schedules were used for the calibrations, different people performed the calibrations, different instrumentation was used to measure the loads and the outputs, the Large Load Rig was moved to a different site in between the calibrations, and no tare load corrections could be applied to the 1999 data set. Nevertheless, the calibration data of 2019 is clearly the better data set. This observation is no surprise considering that CALSPAN Force Measurement Systems made significant investments in calibration hardware and process improvements during the last 20 years.

wind tunnel balance↗

Absolute flux density calibrations: Receiver saturation effects

The effect of receiver saturation was examined for a total power radiometer which uses an ambient load for calibration. Extension to other calibration schemes is indicated. The analysis shows that a monotonic receiver saturation characteristic could cause either positive or negative measurement errors, with polarity depending upon operating conditions. A realistic model of the receiver was made by using a linear-cubic voltage transfer characteristic. The evaluation of measurement error for this model provided a means for correcting radio source measurements.

Freiley, A. J.↗

Open-Source High-Fidelity Aggregate Composite Load Models of Emerging Load Behaviors for Large-Sale Analysis

The goal of this project is to accurately model the dynamic loads for power system planning and operation and to address the challenges inherent in such modeling. Existing load models are inadequate to handle the increasing proliferation of residential air conditioner loads and distributed energy resources, the emerging trends of price-responsive demand, and the growing importance of protective devices in equipment and buildings. A need has emerged to develop a fundamentally new class of load models and next-generation data tools. This work proposes to develop a set of regional–level, scalable open source load models and tools, including large-scale aggregate load protection, concept of price responsive demand, advanced load composition data, next-generation load model data tools, and advanced composite load model calibration and validation frameworks to address new challenges in the representation of next-generation load models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Calibration for Thrust and Airflow Measurements in the CE-22 Advanced Nozzle Test Facility

CE-22 facility procedures and measurements for thrust and airflow calibration obtained with choked-flow ASME nozzles are presented. Six calibration nozzles are used at an inlet total pressure from 20 to 48 psia. Throat areas are from 9.9986 to 39.986 sq. in.. Throat Reynolds number varies from 1.8 to 7.9 million. Nozzle gross thrust coefficient (CFG) uncertainty is 0.25 to 0.75 percent, with smaller uncertainly generally for larger nozzles and higher inlet total pressure. Nozzle discharge coefficient (CDN) uncertainty is 0.15 percent or less for all the data. ASME nozzle calibrations need to be done before and after research model testing to achieve these uncertainties. In addition, facility capability in terms of nozzle pressure ratio (NPR) and nozzle airflow are determined. Nozzle pressure ratio of 50 or more is obtainable at 40 psia for throat areas between 20 and 30 sq. in.. Also presented are results for two of the ASME nozzles vectored at 10deg, a dead-weight check of the vertical (perpendicular to the jet axis) force measurement, a calibration of load cell forces for the effects of facility tank deflection with tank pressure, and the calibration of the metric-break labyrinth seal.

Werner, Roger A.↗

Analytical stress intensity solution for the Stable Poisson Loaded specimen

An analytical calibration of the Stable Poisson Loaded (SPL) specimen is presented. The specimen configuration is similar to the ASTM E-561 compact-tension specimen with displacement controlled wedge loading used for R-curve determination. The crack mouth opening displacements (CMODs) are produced by the diametral expansion of an axially compressed cylindrical pin located in the wake of a machined notch. Due to the unusual loading configuration, a three-dimensional finite element analysis was performed with gap elements simulating the contact between the pin and specimen. In this report, stress intensity factors, CMODs, and crack displacement profiles, are reported for different crack lengths and different contacting conditions. It was concluded that the computed stress intensity factor decreases sharply with increasing crack length thus making the SPL specimen configuration attractive for fracture testing of brittle, high modulus materials.

Ghosn, Louis J.↗

A liquid-helium-cooled absolute reference cold load for long-wavelength radiometric calibration

Design, radiometric and thermal performance, and operation of a large diameter (78 cm) liquid-helium-cooled blackbody absolute reference cold load (CL) for the calibration of microwave radiometers is described. CL provides an absolute calibration near the liquid-helium (LHe) boiling point, with total uncertainty in the radiometric temperature of less than 30 mK over the 2.5-23 cm wavelength operating range. CL was used at several wavelengths at the South Pole, Antarctica and the White Mountain Research Center, California. Results show that, for the instruments operated at 20-, 12-, 7.9-, and 4.0 cm wavelength at the South Pole, the total corrections to the LHe boiling-point temperature (about 3.8 K) were 48 +/-23, 18 +/-10, 10 +/-18, and 15 +/-mK.

Bensadoun, Marc↗

Wind Tunnel Balance Calibration: Are 1,000,000 Data Points Enough?

Measurement systems are typically calibrated based on standard practices established by a metrology standards laboratory, for example the National Institute for Standards and Technology (NIST), or dictated by an organization's metrology manual. Therefore, the calibration is designed and executed according to an established procedure. However, for many aerodynamic research measurement systems a universally accepted standard, traceable approach does not exist. Therefore, a strategy for how to develop a calibration protocol is left to the developer or user to define based on experience and recommended practice in their respective industry. Wind tunnel balances are one such measurement system. Many different calibration systems, load schedules and procedures have been developed for balances with little consensus on a recommended approach. Especially lacking is guidance the number of calibration data points needed. Regrettably, the number of data points tends to be correlated with the perceived quality of the calibration. Often, the number of data points is associated with ones ability to generate the data rather than by a defined need in support of measurement objectives. Hence the title of the paper was conceived to challenge recent observations in the wind tunnel balance community that shows an ever increasing desire for more data points per calibration absent of guidance to determine when there are enough. This paper presents fundamental concepts and theory to aid in the development of calibration procedures for wind tunnel balances and provides a framework that is generally applicable to the characterization and calibration of other measurement systems. Questions that need to be answered are for example: What constitutes an adequate calibration? How much data are needed in the calibration? How good is the calibration? This paper will assist a practitioner in answering these questions by presenting an underlying theory on how to evaluate a calibration based on objective measures. This will enable the developer and user to design calibrations with quantified performance in terms of their capability to meet the user's objectives and a basis for comparing existing calibrations that may have been developed in an ad-hoc manner.

Rhew, Ray D.↗

Results of the first complete static calibration of the RSRA rotor-load-measurement system

The compound Rotor System Research Aircraft (RSRA) is designed to make high-accuracy, simultaneous measurements of all rotor forces and moments in flight. Physical calibration of the rotor force- and moment-measurement system when installed in the aircraft is required to account for known errors and to ensure that measurement-system accuracy is traceable to the National Bureau of Standards. The first static calibration and associated analysis have been completed with good results. Hysteresis was a potential cause of static calibration errors, but was found to be negligible in flight compared to full-scale loads, and analytical methods have been devised to eliminate hysteresis effects on calibration data. Flight tests confirmed that the calibrated rotor-load-measurement system performs as expected in flight and that it can dependably make direct measurements of fuselage vertical drag in hover.

Acree, C. W., Jr.↗

New Approach for the Assessment of Interactions of a Strain-Gage Balance

A new approach was developed to assess interactions of a strain-gage balance. The approach compares interactions observed during a calibration of the balance with interactions observed during the application of check loads. The approach assumes that alignment errors of the calibration loads are negligible. In that case, interactions observed during the calibration can be used as a reference for the assessment of interactions of check loads. The new approach first fits interactions of a single-component load of the calibration data using simple regression models. Then, interactions of the check loads are predicted by using the check load values as inputs for the regression models of the interactions. In the next step, absolute values of differences between predicted and observed interactions of the check loads are computed. Afterwards, the largest differences are compared with empirical thresholds to assess how well the interactions of the check load data agree with the interactions of the calibration data. Recently obtained data sets of a six-component force balance are used to illustrate the application of the new approach. It is also demonstrated how knowledge of balance design characteristics can benefit the assessment of interactions.

wind tunnel test↗

Force-Measuring Clamps

Force-measuring clamps have been invented to facilitate and simplify the task of measuring the forces or pressures applied to clamped parts. There is a critical need to measure clamping forces or pressures in some applications for example, while bonding sensors to substrates or while clamping any sensitive or delicate parts. Many manufacturers of adhesives and sensors recommend clamping at specific pressures while bonding sensors or during adhesive bonding between parts in general. In the absence of a force-measuring clamp, measurement of clamping force can be cumbersome at best because of the need for additional load sensors and load-indicating equipment. One prior method of measuring clamping force involved the use of load washers or miniature load cells in combination with external power sources and load-indicating equipment. Calibrated spring clamps have also been used. Load washers and miniature load cells constitute additional clamped parts in load paths and can add to the destabilizing effects of loading mechanisms. Spring clamps can lose calibration quickly through weakening of the springs and are limited to the maximum forces that the springs can apply. The basic principle of a force-measuring clamp can be implemented on a clamp of almost any size and can enable measurement of a force of almost any magnitude. No external equipment is needed because the component(s) for transducing the clamping force and the circuitry for supplying power, conditioning the output of the transducers, and displaying the measurement value are all housed on the clamp. In other words, a force-measuring clamp is a complete force-application and force-measurement system all in one package. The advantage of unitary packaging of such a system is that it becomes possible to apply the desired clamping force or pressure with precision and ease.

Nunnelee, Mark↗

Room Temperature Quasi-static Characterization and Constitutive Model Parametrization of Flexible Polyurethane Foams of Different Densities Loaded in Different Orientations

This report describes the efforts to characterize and model General Plastics TF6070 and EF4000 flexible polyurethane foams under room temperature, large deformation quasi-static cyclic mechanical loading conditions. Densities from three to fifteen pound per cubic foot (PCF) are examined, which correspond to relative densities of approximately 4 to 20%. These foams are open cell structured and flexible at room temperature with a glass transition transition less than -30°C, and they fully recover their original shape when unloaded (at room temperature). Uniaxial compression tests were conducted with accompanying lateral image series for Digital Image Correlation (DIC) analysis with the goal of extracting transverse strain responses. Due to difficulties with DIC analysis at large strains, lateral strains were instead extracted for each test via edge tracking. The experimental results exhibit a nonlinear elastic response and anisotropic material behavior (particularly for the lower densities). Some hysteresis is observed that is different between the first and subsequent cycles of deformation indicating both a small degree of permanent damage (reduced stiffness during reloading) and viscoelasticity. These inelastic mechanisms are not considered in the modeling and calibration in this report. This work considers only the rate independent, room temperature foam behavior. Individual foam densities were calibrated for loading in two directions, parallel and perpendicular to the foam bubble rise direction, since the mechanical behavior is different in these two directions. The Flex Foam constitutive model was used for all parameterizations despite the fact that the model is isotropic. A review of the constitutive model is given as well as necessary data reduction procedures to parameterize it for each foam density and orientation are discussed. Finally, two different parameterizations are developed that take the undeformed foam density as an input that span all densities considered. These two parameterized models represent foams loaded in the rise and transverse directions respectively. We summarize the assumptions and limitations of the parameterizations provided in this report to guide analysis choices with them. All parameterizations presented herein have the following traits, room temperature, rate independent, damage-free, and non-dissipative . Isotropy (even if they are representing anisotropic data). Supplied Sierra Solid Mechanics Flex Foam Model Inputs are in units: pounds, inches, Celsius, and seconds

36 MATERIALS SCIENCE↗

Strain gaged struts and data reduction techniques to maximize quality data from spacecraft flight measurements

The flight instrumentation for the Viking project was established to obtain environmental data, and maximize the data obtainable from the limited number of telemetry channels. To achieve these objectives, a set of six struts were strain gaged and calibrated as load cells to obtain a complete force-time history across an interface. The force-time history can be used with an analytical model to calculate the response of any part of the structure above the instrumented interface. Special matched filters were required to reduce the flight data and derive the phase correlated loads. Flight data results from the Viking Dynamic Simulator flown in February 1974 are described in addition to ground test results used to verify the data reduction process.

Day, F. D., III↗