Search NASA⌕ Search

SEARCH · Search NASA

Results for “loading simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Computing virtual dark-field X-ray microscopy images of complex discrete dislocation structures from large-scale molecular dynamics simulations

Dark-field X-ray microscopy (DFXM) is a novel diffraction-based imaging technique that non-destructively maps the local deformation from crystalline defects in bulk materials. While studies have demonstrated that DFXM can spatially map 3D defect geometries, it is still challenging to interpret DFXM images of the high-dislocation-density systems relevant to macroscopic crystal plasticity. This work develops a scalable forward model to calculate virtual DFXM images for complex discrete dislocation structure(s) (DDS) obtained from atomistic simulations. Our new DDS-DFXM model integrates a non-singular formulation for calculating the local strain from the DDS and an efficient geometrical optics algorithm for computing the DFXM image from the strain field. We apply the model to complex DDS obtained from a large-scale mol­ecular dynamics simulation of compressive loading on single-crystal silicon. Simulated DFXM images exhibit prominent contrast for dislocation features between the multiple slip systems, demonstrating the potential of DFXM to resolve features from dislocation multiplication. In conclusion, the integrated DDS-DFXM model provides a toolbox for DFXM experimental design and image interpretation in the context of bulk crystal plasticity for a range of measurements across shock plasticity and the broader materials science community.

X-ray imaging↗

Analytical Voltage Sensitivity Analysis for Unbalanced Power Distribution System

Large scale integration of distributed energy resources and electric vehicles in a transactive energy environment present new challenges in terms of voltage stability and fluctuations in a power distribution system. The impact of different level of DER/EV penetration on the voltages across the network is typically quantified through voltage sensitivity analyses. Existing methods of voltage sensitivity analysis are computationally expensive and prior efforts to develop analytical approximation lacks generality and have not been effectively validated. The objective of this work is to provide a new analytical method of voltage sensitivity analysis that has low computational cost and also allows for stochastic analysis of voltage change. This paper first derives an analytical approximation of change in voltage at a particular bus due to change in power consumption at other bus in a radial three phase unbalanced power distribution system. Then, the proposed method is shown to be valid for different load configurations, which demonstrates its generality. The results from our analytical approach is validated via classical load flow simulation of the test system based on IEEE 37 bus network. The proposed method is shown to have good accuracy, and computation complexity is of order O(1), compared to O(n3) in classical sensitivity analysis approaches.

Munikoti, Sai↗

Reinforcement Learning for Volt- Var Control: A Novel Two-stage Progressive Training Strategy

This paper develops a reinforcement learning (RL) approach to solve a cooperative, multi-agent Volt-Var Control (VVC) problem for high solar penetration distribution systems. The ingenuity of our RL method lies in a novel two-stage progressive training strategy that can effectively improve training speed and convergence of the machine learning algorithm. In Stage 1 (individual training), while holding all the other agents inactive, we separately train each agent to obtain its own optimal VVC actions in the action space: fconsume, generate, do-nothingg. In Stage 2 (cooperative training), all agents are trained again coordinatively to share VVC responsibility. Rewards and costs in our RL scheme include (i) a system-level reward (for taking an action), (ii) an agent-level reward (for doing-nothing), and (iii) an agent-level action cost function. This new framework allows rewards to be dynamically allocated to each agent based on their contribution while accounting for the trade-off between control effectiveness and action cost. The proposed methodology is tested and validated in a modified IEEE 123-bus system using realistic PV and load profiles. Simulation results confirm that the proposed approach is robust and computationally efficient; and it achieves desirable volt-var control performance under a wide range of operation conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Efficient and Robust Dynamic Simulation of Power Systems With Holomorphic Embedding

Dynamic simulation is vitally important in power system analysis, but traditional approaches based on numerical integration over small time steps are time-consuming. Also, the Newton-Raphson method suffers from difficulty in convergence when solving nonlinear algebraic equations. In this paper, we propose a novel dynamic simulation approach based on holomorphic embedding. By obtaining a high-order approximation of system dynamics, it achieves a much larger time step and thus enhances the computational efficiency significantly. In addition, the new approach avoids non-convergence issues in solving algebraic equations, which improves robustness. The approach includes flexible modeling of synchronous generators and controllers, and we propose a method for modeling generator coordinate transformations. The approach is tested on the IEEE 39-bus, 10-generator system and a Polish 2383-bus, 327-generator system. The results demonstrate promising computational efficiency and satisfactory numerical robustness for the analysis of large-scale power systems.

42 ENGINEERING↗

EXPERIMENTAL AND MODELLING ANALYSIS OF A LARGE-SCALE TWO-PHASE LOOP THERMOSYPHON

Liquid pumping requires large quantities of electrical energy, including about 7% of the energy of building heating, ventilation, and air conditioning (HVAC) systems. To replace pumped condenser-cooling tower water loops with a passive alternative system, we implemented a commercial-scale two-phase loop thermosyphon (TPLT). The unit consists of a 13 m riser integrated with a commercially available cooling tower and circulation water heater that simulates heat loads up to 25 kW. In addition to providing passive cooling capabilities, the cooling tower unit is also maintenance free, reliable, and can operate in both dry and wet modes. This study characterizes the performance (temperature difference between the evaporator and condenser) and the two-phase flow behavior of the loop under various refrigerant charges. Sight glasses installed throughout the loop are used to identify the operating flow regimes in the riser and downcomer. Over the range of operating conditions, we identified that there is an optimal refrigerant charge range for a specific heat load at which near-isothermal operation can be achieved. We further developed a model to predict the operating flow rate and gravitational height in the downcomer and compared it with the experimental data. The results show that the model agrees with the experimental data, in particular the threshold gravitational head height at which there will be subcooled liquid at the condenser exit, indicating that it can be used as a predictive tool for identifying the optimal loop charge for a given heat load.

Loop thermosyphon, passive two phase↗

Investigating the Particle Growth in Bimodal Pt/C Catalysts by In-Situ Small-Angle X-ray Scattering: Challenges in the Evaluation of Stress Test Protocol-Dependent Degradation Mechanisms

The influence of different combinations of accelerated stress test (AST) protocols simulating load-cycle and start/stop conditions of a proton exchange membrane fuel cell (PEMFC) vehicle is investigated on a bimodal Pt/C catalyst. The bimodal Pt/C catalyst, prepared by mixing two commercial catalysts, serves as a model system and consists of two distinguishable size populations. The change in mean particle size was investigated by in situ small-angle X-ray scattering (SAXS). The comparison to the reference catalysts, i.e., the two single-size population catalysts, uncovers the presence of electrochemical Ostwald ripening as a degradation mechanism in the bimodal catalyst. Increasing the harshness of the applied AST protocol combinations by faster changing between load-cycle or start/stop conditions, the particle size of the larger population of the bimodal catalyst increases faster than expected. Surprisingly, the change in mean particle size of the smaller size population indicates a smaller increase for harsher AST protocols, which might be explained by a substantial electrochemical Ostwald ripening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PVade (PV Aerodynamic Design Engineering) [SWR-23-49]

PV Aerodynamic Design Engineering (PVade) is an open-source fluid-structure interaction (FSI) solver which can accurately simulate wind loads and aerodynamic stability in solar-tracking PV arrays. PVade’s pressure profiles and inertial load time series can be used as inputs into mechanical module models to study degradation mechanisms including cracking of cells, weathering of cracked cells, and glass breakage. This software enables PV plant owners to predict optimal high-wind stow strategies under a variety of weather and site conditions.

Young, Ethan↗

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resilient El Rito, Microgrif System Laboratory (Village of El Rito) (Final CTAP Report)

Sandia provided technical assistance to Kit Carson Electric Cooperative (KCEC) to assess the technical merits of a proposed community resilience microgrid project in the Village of El Rito, New Mexico (NM). The project includes a proposed community resilience microgrid in the Village of El Rito, NM, around the campus of Northern New Mexico College (NNMC). A conceptual microgrid analysis plan was performed, considering a campus and community-wide approach. The analysis results provided conceptual microgrid configurations, optimized according to the performance metrics defined. The campus microgrid was studied independently and many conceptual microgrid solutions were provided that met the performance requirements. Considering the existing 1.5 MW PV system on campus far exceeds the simulated campus load peak and energy demand, a small battery installation was deemed sufficient to support the campus microgrid goals. Following the analysis and consultation, it was determined that the core Resilient El Rito team will need to further investigate the results for additional economic and environmental considerations to continue toward the best approach for their goals and needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Test Report Neutron Scintillator Array Dry Storage Cask Scanner FY2024

During two weeks of Field Testing at the Idaho National Laboratory INTEC Cask Farm in July and August 2024, the LLNL Dry Storage Cask Scanner Array was lifted on top of an MC-10 dry storage fuel cask and operated to acquire neutron and gamma-ray data from the 24 fuel bundle positions. Neutron and gamma-ray data acquisition scans across the top of the cask of varying dwell times were performed July 15-18, 2024 and August 19-22, 2024 to evaluate the ability of the scanner data to reveal asymmetries in the fuel positions that reflect asymmetries in the MC-10 cask fuel bundle loading. The MC-10 cask 24 position fuel bundle loading at the INTEC Cask Farm is well documented, including the locations of six empty fuel bundle positions. This loading presents an opportunity to test the ability of the scanner system to detect diversion of spent fuel bundles as well as to validate the MC-10 cask MCNP modeling. The cask scanner array consists of six Stilbene crystal scintillator detectors and a linear actuator frame that moves the six detectors across the MC-10 dry storage cask to obtain data above each of the 24 fuel bundle positions. The detectors are connected to a pulse-shape discrimination data acquisition system capable of generating separate neutron and gamma-ray spectra for each detector and for each scan position. From the prior single detector Field Test in 2021 and iteration with MCNP modeling, the neutron and gamma-ray data were analyzed in multiple energy regions to identify an analysis method that would provide the strongest and most consistent signature of the asymmetric MC-10 cask fuel loading1 . From both the 2021 Field Test and the current Field Test results, the neutron capture gamma-ray count rate around 2.2 MeV provides the strongest signature of the asymmetric MC-10 cask fuel loading and has qualitative agreement with MCNP calculations. Counting all gamma-rays produces a similar signature. Neutrons emerging from the cask top are moderated and captured by the hydrogen in the polyethylene moderator and scintillator detector, producing a 2.2 MeV gamma ray which is seen in the scintillator gamma-ray spectrum. The count rate in the 2.2 MeV gamma-ray region is ~50 c/s, which is ~1000x higher than the ~0.05 n/s rate in the > 4MeV neutron region, and ~50x greater than the ~1 n/s rate in the neutrons > 500 keV region. Analysis of the 2.2 MeV neutron-capture Compton-scattered gamma-rays produces a statistically significant signature of the INTEC Cask Farm MC-10 asymmetric fuel loading. MCNP simulations indicate that the average neutron energy spectrum offers the potential to detect a large asymmetry from several missing bundles as well as individual missing fuel bundles. Testing this feature will require measurements on a cask with single missing elements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Hydropower Game: An Interactive Learning Tool for the Future Hydropower Workforce

This report documents a Seedling project supported by the U.S. Department of Energy (DOE) Water Power Technologies Office (WPTO), conducted by Argonne National Laboratory (ANL) and the National Laboratory of the Rockies (NLR). The Seedling and Sapling Program provides small grants over short duration to enable early-stage research at national laboratories. This funding mechanism is intended to cultivate innovative ideas and expand research road maps in hydropower and marine energy technologies. Under this Seedling award, the project team developed an educational outreach tool, or “serious game”, built in Python and powered by the Pygame library, aimed at teaching fundamental hydropower concepts through an engaging, interactive learning experience. The game features multiple lessons covering several hydropower topics while allowing for expansion and customization in the instance of future funding availability: • Hydropower Plant Types: Players explore and compare the mechanics and applications of run-of-river, dam hydropower, and pumped-storage hydropower. • Flow Dynamics and Power Generation: Interactive tasks demonstrate how release rate and hydraulic head combine to determine power output. • Grid Operations and Load Following: Simulations illustrate how hydropower facilities respond to fluctuating electricity demand to balance the grid. • Market Integration: Levels scaffold understanding of how hydropower interfaces with the broader energy market, including operational and economic considerations. The tool was showcased at several science, technology, engineering, and mathematics (STEM) outreach events, where it was demoed to students, educators, and the general public. These events provided valuable opportunities to collect feedback on the gameplay, storyline, and educational objectives from a wide audience. The game was presented at STEMapalooza, Introduce a Girl to Engineering Day, STEMCON, and Clean Currents 2025. Insights gathered during these demonstrations informed refinements to the game’s user experience and strengthened its effectiveness as an educational tool for teaching hydropower concepts. This report outlines the game’s design philosophy, educational objectives, technical implementation, user experience insights, and potential for broader deployment within educational and workforce development contexts. It emphasizes how gamified learning can demystify complex hydropower science and inspire interest in water-power technologies. The project’s success demonstrates the value of Seedling funding in fostering creative, lowcost educational tools that support DOE’s mission to advance energy literacy and innovation. The report concludes with recommendations for expanding the tool by adding new levels, integrating assessment metrics, and exploring commercialization or deployment pathways through future Sapling funding. The official webpage of the Hydropower Game, which includes a link to the educational tool, can be accessed at www.anl.gov/hydropower/hydropower-game.

13 HYDRO ENERGY↗

A Finite Element Study of Stress Reduction Techniques in REBCO HTS Conductor on a Round Cable (CORC) Cable

ReBCO high-temperature superconducting (HTS) tape is critical for achieving the high magnetic fields needed in next-generation particle accelerators. Enhancing the mechanical performance of ReBCO tape increases its critical current by reducing internal stress, especially in the superconducting layer. A finite element study examined how copper layer properties affect stress in ReBCO conductor on a round core (CORC) cables. The cable was modeled as a doubly supported beam under uniform compressive stresses."cable was modeled as a doubly supported beam under uniform load to simulate bending. A staged modeling approach from a single tape to a six-layer stack enabled validation and efficient parameter studies. Increasing the yield strength and Young s modulus of the copper layers reduced peak stress in the ReBCO layer. These results support development of improved tape stacks for high-field accelerator magnets

Mueller, Scott [Northern Illinois U.]↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sealability Qualification of Material Extruded Zytel Gaskets at Extreme Temperatures

In this work, an in-depth qualification of additively manufactured Zytel for gasketing proton exchange membrane fuel cells (PEMFC’s) subject to extreme temperature conditions. The temperature cycling of the PEMFC from 55°C to 100°C accelerates the deterioration of these gaskets compared to that of conventional operation. The additive manufacturing process employed to print these gaskets is material extrusion using Zytel filament. In order to see the effects of the temperature of interest on the printed specimen, each specimen was thermally soaked and then charactered and tested according to ASTM standard F37B. ASTM F37B tests a materials ability to seal and maintain it while bearing both a compressive load and internal pressure load to simulate being in static operation. This process of thermally soaking and sealability testing is shown to show the validity of both this material and additive manufactured components for other applications as well. It is observed that soaking the gaskets at 100°C corrects some of the defects that are present after printing such as missing layers and small voids on the surface of the samples. This allowed for the hot soaked materials to perform better than the samples at room temperature and cold soaked.

Sealability↗

Exploring the Potential of ASHRAE Guideline 36 in District Cooling Systems: Preprint

ASHRAE Guideline 36-2021 (G36) provides high-performance control sequences for all-air and hydronic HVAC systems, and it has proven effective at reducing energy use for single building all-air equipment. The most recent version of G36 included control sequences for water-cooled chiller plants, which can be used in district cooling systems (DCSs). Despite not being a traditional application of G36 controls, DCSs could benefit from energy savings that G36 control sequences have demonstrated in single building systems. We therefore investigate the possibility to extend G36 chiller plant control from a single building to district cooling using a real-world district cooling system in Boulder, Colorado as a case study. Four timeframes representing low to peak loads are simulated and analyzed to compare energy use of the district cooling system for three control sequences. Results show that although G36 chiller plant sequences can be applied to DCSs, further analysis and potentially control optimization is needed to ensure energy savings compared to default controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling of Microgrid for Critical Data Center Applications

As part of continuing efforts to develop support, understanding, and infrastructure of data center integration onto the electric grid, our work aims to model and analyze the behavior of data center loads in a microgrid power system. Our model consists of renewable energy sources, batteries, and a nuclear reactor-steam Rankine cycle to power data center loads. The simulation studies investigate the electrical behavior of the microgrid system to assess its ability in supporting large data center electrical demands.

14 - SOLAR ENERGY↗

Evaluation of enzymatic depolymerization of PET, PTT, and PBT polyesters

Millions of tons of waste polyester plastics, including polyethylene terephthalate (PET), polytrimethylene terephthalate (PTT), and polybutylene terephthalate (PBT), end up in the environment as soil and water contaminants. Recent advances in enzymatic polyester degradation have motivated researchers toward biorecycling of plastic wastes. Leaf-branch compost cutinase (LCC) enzymes have been proven to be effective in the biodegradation of PET. This study focuses on enzymatic depolymerization of waste PET, PTT, and PBT materials by using an ICCG variant of LCC (LCC ICCG ) produced from Escherichia coli BL21(DE3). The degradation efficiency of the polyesters was determined by the monomer terephthalic acid (TPA) released from the depolymerization reaction. It was found that the most efficient depolymerization was achieved for PET, followed by PTT and PBT. A kinetic model based on Langmuir adsorption and the Michaelis-Menten equation was developed to describe the enzymatic depolymerization of PET, PTT, and PBT with various enzyme and substrate loadings. The model simulation results revealed that the LCCICCG enzyme loading should be linearly increased as the work capacity of the polyester substrate increases. A specific enzyme loading of 0.91 mg/g PET is suggested to achieve 90% depolymerization of PET within three days. Furthermore, the experimental data and model simulation results can be used to help further engineer the enzyme and process to achieve a complete biodegradation of polyester wastes at large scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗