Search NASA⌕ Search

SEARCH · Search NASA

Results for “local control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Structural “ δ Doping” to Control Local Magnetization in Isovalent Oxide Heterostructures

Modulation and δ-doping strategies, in which atomically thin layers of charged dopants are precisely deposited within a heterostructure, have played enabling roles in the discovery of new physical behavior in electronic materials. Here in this paper, we demonstrate a purely structural “δ-doping” strategy in complex oxide heterostructures, in which atomically thin manganite layers are inserted into an isovalent manganite host, thereby modifying the local rotations of corner-connected MnO 6 octahedra. Combining scanning transmission electron microscopy, polarized neutron reflectometry, and density functional theory, we reveal how local magnetic exchange interactions are enhanced within the spatially confined regions of suppressed octahedral rotations. Finally, the combined experimental and theoretical results illustrate the potential to utilize noncharge-based approaches to “doping” in order to enhance or suppress functional properties within spatially confined regions of oxide heterostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Traffic Smoothing Using Explicit Local Controllers: Experimental Evidence for Dissipating Stop-and-go Waves with a Single Automated Vehicle in Dense Traffic

This article presents experimental evidence of the ability of a single automated vehicle acting as a controller to effectively dissipate stop-and-go waves in real traffic. The automated vehicle succeeded in stabilizing the speed profile by reducing oscillations in time and speed variations between vehicles during rush hour on I-24 in the Nashville area. Here, we detail the control design, deployment and results obtained in this experiment, conducted as part of the CIRCLES consortium’s “MegaVanderTest” 2022, which involved a total of 100 automated vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-F-T-221: An Assessment of the Potential for Improved Local Control of Skull- Base Chordomas Via Reduction of the Proton Beam Range Uncertainty

Purpose: The beam range uncertainty presents a special challenge for proton therapy. Novel technologies currently under development offer strategies to reduce the range uncertainty [1,2]. This work quantifies the potential advantages that could be realized by such a reduction for dosimetrically challenging chordomas at the base of skull. Therapeutic improvement was assessed by evaluating tumor control probabilities (TCP) and normal tissue complication probabilities (NTCP). Methods: Treatment plans were made for a modulated-scanned proton delivery technique using the Eclipse treatment planning system. The prescription dose was 7920 cGy to the CTV. Three different range uncertainty scenarios were considered: 5 mm (3.5% of the beam range + 1 mm, representing current clinical practice, “Curr”), 2 mm (1.3%), and 1 mm (0.7%). For each of 4 patients, 3 different PTVs were defined via uniform expansion of the CTV by the value of the range uncertainty. Tumor control probability (TCP) and normal tissue complication probabilities (NTCPs) for organs-at-risk (OARs) were calculated using the Lyman-Kutcher-Burman[3] formalism and published model parameters [ref Terahara[4], quantec S10, Burman Red Journal v21 pp 123]. Our plan optimization strategy was to achieve PTV close to prescription while maintaining OAR NTCP values at or better than the Curr plan. Results: The average TCP values for the 5, 2, and 1 mm range uncertainty scenarios are 51%, 55% and 65%. The improvement in TCP for patients was between 4 and 30%, depending primarily on the proximity of the GTV to OAR. The average NTCPs for the brainstem and cord were about 4% and 1%, respectively, for all target margins. Conclusion: For base of skull chordomas, reduced target margins can substantially increase the TCP without increasing the NTCP. This work demonstrates the potential significance of a reduction in the range uncertainty for proton beams.

60 APPLIED LIFE SCIENCES↗

Data for: Subsurface Interface Structure Controlling Local Electronic Properties of Epitaxial Graphene on SiC(0001)

Recently realized high-mobility semiconducting epitaxial graphene on silicon carbide, provided an important step towards integration of the graphene-based system into active components in post-silicon micro- and nano-electronics. However, the exact atomic-scale structure and the complex bonding configurations of the first epitaxial graphene carbon layer remain an open problem. Our recent report has shed new light on understanding this interface, where the external transverse electric field-dependent dynamic switching behavior of the Cbuffer-SiC bonds was observed. Here, using scanning tunneling microscopy and spectroscopy (STM and STS), we present the direct evidence of silicon (Si) vacancies at the interface and provide their distribution at the topmost reconstructed SiC(0001) layer. Experimental STM and density functional theory modeling data were used in the preparation of figures in a published article in the Journal of Physical Chemistry Letters. Files related to the figures and supplementary materials in the article are present in this dataset in .txt format.

Condensed matter imaging↗

Data for: Subsurface Interface Structure Controlling Local Electronic Properties of Epitaxial Graphene on SiC(0001)

Recently realized high-mobility semiconducting epitaxial graphene on silicon carbide, provided an important step towards integration of the graphene-based system into active components in post-silicon micro- and nano-electronics. However, the exact atomic-scale structure and the complex bonding configurations of the first epitaxial graphene carbon layer remain an open problem. Our recent report has shed new light on understanding this interface, where the external transverse electric field-dependent dynamic switching behavior of the Cbuffer-SiC bonds was observed. Here, using scanning tunneling microscopy and spectroscopy (STM and STS), we present the direct evidence of silicon (Si) vacancies at the interface and provide their distribution at the topmost reconstructed SiC(0001) layer. Experimental STM and density functional theory modeling data were used in the preparation of figures in a published article in the Journal of Physical Chemistry Letters. Files related to the figures and supplementary materials in the article are present in this dataset in .txt format.

Condensed matter imaging↗

Optimal local control of flexible structures

The steady state solution of the linear quadratic optimal control problem with the constraint that only partial state information is available for feedback is derived. This development results in a systematic and computationally efficient approach for reducing the complexity of the control law for high order systems. Numerical examples and performance evaluation of (1) a simple fourth order system, and (2) a free-free flexible beam, are included.

Schaechter, D. B.↗

Io meteorology - How atmospheric pressure is controlled locally by volcanos and surface frosts

The present modification of the Ingersoll et al. (1985) hydrodynamic model of the SO2 gas sublimation-driven flow from the day to the night side of Io includes the effects of nonuniform surface properties noted in observational studies. Calculations are conducted for atmospheric pressures, horizontal winds, sublimation rates, and condensation rates for such surface conditions as patchy and continuous frost cover, volcanic venting, surface temperature discontinuities, subsurface cold trapping, and the propagation of insolation into the frost. While pressure is found to follow local vapor pressure away from the plumes, it becomes higher inside them.

Ingersoll, Andrew P.↗

Local control robotic surgical devices and related methods

The various robotic medical devices include robotic devices that are disposed within a body cavity and positioned using a support component disposed through an orifice or opening in the body cavity. Additional embodiments relate to devices having arms coupled to a device body wherein the device has a minimal profile such that the device can be easily inserted through smaller incisions in comparison to other devices without such a small profile. Further embodiments relate to methods of operating the above devices.

Markvicka, Eric↗

"Traffic smoothing using explicit local controllers"

The dissipation of stop-and-go waves attracted recent attention as a traffic management problem, which can be efficiently addressed by automated driving. As part of the 100 automated vehicles experiment named MegaVanderTest, feedback controls were used to induce strong dissipation via velocity smoothing. More precisely, a single vehicle driving differently in one of the four lanes of I-24 in the Nashville area was able to regularize the velocity profile by reducing oscillations in time and velocity differences among vehicles. Quantitative measures of this effect were possible due to the innovative I-24 MOTION system capable of monitoring the traffic conditions for all vehicles on the roadway. This paper presents the control design, the technological aspects involved in its deployment, and, finally, the results achieved by the experiment.

Hayat, Amaury↗

Fiber-optic crossbar switch

Switch automatically crosspatches optical signals with little loss. Device is furnished with local control and remote control. Local control can be manual from control panel or by computer data bus. In remote control, switch is slaved to remote manual panel computer data bus.

Bell, C. H.↗

A centralized-based method to determine the local voltage control strategies of distributed generator operation in active distribution networks

The increasing penetration of distributed generators (DGs) exacerbates the risk of voltage violations in active distribution networks (ADNs). The var capacity provided by DG inverters is a potential solution for voltage regulation. The conventional centralized control strategies limited by computation and communication burdens are difficult to meet the requirement of rapid voltage control. However, the local control strategies based on real-time measurements have a fast response to the frequent fluctuations of DG outputs. The performance of these local controllers depends on the tuning of the control parameters. This paper proposes a centralized-based method to determine the local voltage control strategies for DGs. A centralized parameter tuning model of control curves is built, in which and curves of DG inverters are mathematically formulated based on piecewise linearization. The original mixed-integer nonlinear programming (MINLP) model is converted into an effectively solved mixed-integer second-order cone programming (MISOCP) model using convex relaxation. The potential benefits of DG inverters are explored to regulate both reactive and curtailed active power, based on local voltage measurements. Case studies on a modified PG&E 69-node distribution system are carried out to verify the effectiveness of the proposed method. Results show that power losses of ADNs are significantly reduced and voltage profiles are also improved.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensor impacts on building and HVAC controls: A critical review for building energy performance

Building operations rely heavily on control systems and sensors. This paper provides a sophisticated literature review on sensor systems in building/HVAC systems, particularly in the context of controls, and their impacts on energy efficiency and thermal comfort. This study aims to understand the previous and current research and identify future research opportunities on this subject. The reviewed sensor systems were used for heuristic rule-based controls, local controls, and advanced optimal controls for existing and emerging technologies. Five major aspects of sensors are reviewed here: control loops for sensors, sensor types, sensor locations, sensor data, and a sensor impact evaluation framework. To augment the literature review, comprehensive standardized interviews were also conducted with relevant industry experts and practitioners. These interviews were designed and performed to (1) identify significant factors for selecting sensor sets and current undergoing issues, (2) identify potential improvements in sensor configuration/deployment, and (3) integrate expert (e.g., researcher, building operation practitioner) knowledge and experiences to develop structured use-case scenarios. Researchers collected and analyzed 31 interview responses for this paper.

Building control↗

SU-F-T-203: High Dose Definitive Proton Therapy with Integrated Boost to Hypoxic Subvolumes Determined by [18F]-Fluoromisonidazole (FMISO) PET/CT for Patients with Recurrent Chordomas Using Intensity Modulated Proton Therapy (IMPT)

Purpose: Recurrent chordomas are difficult to control locally. This dosimetric study investigates the feasibility of dose escalation to hypoxic regions, visualized on FMISO-PET, while respecting the dose constraints to the neighboring normal tissues/organs. We propose to deliver a higher dose to the areas of hypoxia (84.5Gy) using IMPT with the goal of improving local control. Methods: We currently have four patients with hypoxic subvolumes (HSV) greater than 10cc from the FMISO-PET image. The HSV was delineated based on the standardized uptake values of greater than 1.4 times of the muscle mean. Gross tumor volume (GTV) was delineated using planning CT with the assistance of MRI fusion. The dose scheme is 50.4Gy RBE to CTV in 1.8Gy fractions, followed by an integrated boost of 27.0Gy RBE to GTV in 1.8Gy fractions and 34.5Gy RBE to HSV in 2.3Gy fractions. IMPT integrated boost plans were optimized with multi-criteria optimization (MCO). Posterior-anterior beam angles were used for these plans. We also propose using two posterior oblique fields to boost HSV to spare the skin folding. A medium spot size with 8mm to 15 mm (σ) in air at isocenter with energies from 220 MeV down to 90 MeV was used. Aperture was used for the medium spot size. A small spot size of 2.5 mm to 4.5 mm (σ) in air at isocenter with energies from 240 MeV down to 70 MeV was also proposed. Target coverage and dose to OARs were evaluated. Results: For the sacral chordoma patient that has been planned, the target homogeneity index is 3.2% for HSV, 55.9% for CTV and 11.9% for GTV. The max dose is 77GyRBE to rectum, 86.2GyRBE to sacral nerves and 73.9GyRBE to cauda equina. Conclusion: IMPT with integrated high dose boost to HSV determined from FMISO PET image is feasible. OAR dose constraints were met.

60 APPLIED LIFE SCIENCES↗

A generalized method for optimization of active noise controllers in three-dimensional spaces

In this investigation, the formulation of an optimal active noise controller for harmonic, enclosed sound fields is derived using an indirect boundary element method. The optimal active noise controller is defined as the volume velocity secondary source strengths which minimize the sound pressure level at a number of discrete interior locations. In addition, the formulation of an optimal active noise controller which minimizes the free field power radiated from a generalized, distributed noise source is presented. Representative results are provided for each formulation. For the enclosure problem, results are given for global control, local control, and passive wall treatments using a rectangular cavity. For the free field radiation problem, the effects of secondary source location and quantity on active noise controller performance are investigated. The relative merits of each formulation are discussed.

Mollo, C. G.↗

Local Voltage Control in Distribution Networks: A Game-Theoretic Perspective

Inverter-based voltage regulation is gaining importance to alleviate emerging reliability and power-quality concerns related to distribution systems with high penetration of photovoltaic (PV) systems. This paper seeks contribution in the domain of reactive power compensation by establishing stability of local Volt/VAr controllers. In lieu of the approximate linear surrogate used in the existing work, the paper establishes existence and uniqueness of an equilibrium point using nonlinear AC power flow model. Key to this end is to consider a nonlinear dynamical system with non-incremental local Volt/VAr control, cast the Volt/VAr dynamics as a game, and leverage the fixed-point theorem as well as pertinent contraction mapping argument. Numerical examples are provided to complement the analytical results.

14 SOLAR ENERGY↗