Search NASA⌕ Search

SEARCH · Search NASA

Results for “local oscillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Source self-mixing in the detection of extended incoherent sources

We consider the self-beating of incoherent light from an extended source at a wideband photomixer. The intermediate frequency mean squared current is found to be proportional to the product of the direct detected source power and the power within the IF bandpass about the optical frequency and within the heterodyne field of view. Thus the ratio of the heterodyne signal to self-beating power is proportional to the ratio of local oscillator power to direct detected power. This ratio is usually large for systems employing efficient local oscillators that generate shot-noise-limited operation. In less efficient systems, such as those employing tunable diode lasers, the effects of self-mixing may be significant.

Cohen, S. C.↗

Radiation from a localized Langmuir oscillation in a uniformly magnetized plasma

The electromagnetic radiation at the first and second harmonics of the electron plasma frequency from a localized Langmuir perturbation is computed for the case of a uniformly magnetized plasma. It is assumed that the localized perturbations in both the electrostatic field and plasma density have cylindrical symmetry about the direction of the ambient magnetic field. The analysis is initially performed for such an arbitrary localized perturbation, and then applied to treat the case of a quasi-planar Langmuir soliton propagating in the direction of the magnetic field. An extensive numerical study of the angular dependence of the radiation spectrum as a function of the ratio of the electron plasma and cyclotron frequencies is described.

Freund, H. P.↗

Phase noise effects on turbulent weather radar spectrum parameter estimation

Accurate weather spectrum moment estimation is important in the use of weather radar for hazardous windshear detection. The effect of the stable local oscillator (STALO) instability (jitter) on the spectrum moment estimation algorithm is investigated. Uncertainty in the stable local oscillator will affect both the transmitted signal and the received signal since the STALO provides transmitted and reference carriers. The proposed approach models STALO phase jitter as it affects the complex autocorrelation of the radar return. The results can therefore by interpreted in terms of any source of system phase jitter for which the model is appropriate and, in particular, may be considered as a cumulative effect of all radar system sources.

Lee, Jonggil↗

The U.C. Berkeley Space Sciences Laboratory and Department of Physics Submillimeter Receiver

The UCB submm heterodyne receiver is a complete system for high-resolution astronomical spectroscopy in the 350-micron and 450-micron atmospheric windows. This compact system mounts directly at the Cassegrain focus of large optical and IR telescopes. It consists of a laser local oscillator, open structure mixer, quasi-optical coupling system, a broad-band IF system, and an acoustooptical spectrometer. The local oscillator is a 1-m-long submm laser optically pumped by a CO2 laser. The mixer is a quasi-optical corner-cube antenna structure and Schottky diode. The mixer is currently operated at room temperature, and its performance at 77 K is being evaluated. The system noise temperature is less than 7000 K SSB during observations.

Harris, A. I.↗

Optical antenna gain. II - Receiving antennas

Expressions are developed for the gain of a centrally obscured, circular optical antenna used as the collecting and focusing optics in a laser receiver, involving losses due to (1) incoming light blockage by central obscuration, (2) energy spillover at the detector, and (3) the effect of local oscillator distribution in the case of heterodyne or homodyne detection. Numerical results are presented for direct detection and for three types of local oscillator distribution (uniform, Gaussian, and matched).

Degnan, J. J.↗

A dual-frequency 183/380 GHz receiver for airborne applications

A complete dual-frequency cryogenic heterodyne receiver operating at 183 and 380 GHz is described. The cooled mixers are whisker-contacted GaAs Schottky diodes mounted in reduced-height fundamental-mode waveguide. The local oscillators are Gunn-oscillator-driven multipliers using GaAs varactor diodes as the harmonic generators. Quasi-optical techniques are used extensively for coupling the remote and local oscillator signals into the mixers. The overall system double side-band (DSB) noise temperature is 320 K for the 183-GHz receiver and 650 K for the 380 GHz receiver.

Batelaan, Paul D.↗

Miniaturized Laser Heterodyne Radiometer (LHR) for Measurements of Greenhouse Gases in the Atmospheric Column

This passive laser heterodyne radiometer (LHR) instrument simultaneously measures multiple trace gases in the atmospheric column including carbon dioxide (CO2) and methane (CH4), and resolves their concentrations at different altitudes. This instrument has been designed to operate in tandem with the passive aerosol sensor currently used in AERONET (an established network of more than 450 ground aerosol monitoring instruments worldwide). Because aerosols induce a radiative effect that influences terrestrial carbon exchange, simultaneous detection of aerosols with these key carbon cycle gases offers a uniquely comprehensive measurement approach. Laser heterodyne radiometry is a technique for detecting weak signals that was adapted from radio receiver technology. In a radio receiver, a weak input signal from a radio antenna is mixed with a stronger local oscillator signal. The mixed signal (beat note, or intermediate frequency) has a frequency equal to the difference between the input signal and the local oscillator. The intermediate frequency is amplified and sent to a detector that extracts the audio from the signal. In the LHR instrument described here, sunlight that has undergone absorption by the trace gas is mixed with laser light at a frequency matched to a trace gas absorption feature in the infrared (IR). Mixing results in a beat signal in the RF (radio frequency) region that can be related to the atmospheric concentration. For a one-second integration, the estimated column sensitivities are 0.1 ppmv for CO2, and <1 ppbv for CH4. In addition to producing a standalone ground measurement product, this instrument could be used to calibrate/validate four Earth observing missions: ASCENDS (Active Sensing of CO2 Emissions over Nights, Days, and Seasons), OCO-2 (Orbiting Carbon Observatory), OCO-3, and GOSAT (Greenhouse gases Observational SATellite). The only network that currently measures CO2 and CH4 in the atmospheric column is TCCON (Total Carbon Column Observing Network), and only two of its 16 operational sites are in the United States. TCCON data is used for validation of GOSAT data, and will be used for OCO-2 validation. While these Fourier-transform spectrometers (FTS) can measure the largest range of trace gases, the network is severely limited due to the high cost and extreme size of these instruments (these occupy small buildings and require personnel for operation). The LHR/AERONET instrument offers a significantly smaller (carry-on luggage size) autonomous instrument that can be incorporated into AERONET s much larger (450 instruments) global network.

Steel, Emily↗

High resolution atmospheric spectroscopy using a diode laser heterodyne spectrometer

Ultrahigh resolution (0.007 per cm) atmospheric solar absorption spectra that have been obtained from a tunable infrared heterodyne radiometer are discussed. The radiometer was developed for ground based observations in the 8-12 micron region, and tunability is achieved through the use of Pb-salt semiconductor laser local oscillators. Spectra have been obtained in a piecewise fashion from 9.1 to 11.1 microns using laser emission modes that exhibit characteristics suitable for local-oscillator operation. Spectra showing absorption features of HNO3, O3, CO2, and H2O are presented along with comparisons of experimental and synthetic spectra calculated using a line-by-line atmospheric transmission model.

Hoell, J. M., Jr.↗

Recent progress in submillimeter heterodyne receiver development

The progress made in relation to the development of sensitive submillimeter heterodyne receiver systems is reviewed. Sensitive superconductor-insulator-superconductor (SIS) tunnel junction mixers were demonstrated at frequencies of greater than 1 THz, with noise temperatures of below 1000 K. An alternative mixer technology is that of the superconducting hot electron bolometer, for which sensitivities of 1.2 THz and 2.5 THz were demonstrated. Local oscillator technology is under development. Gunn oscillators followed by Schottky varactor frequency multipliers have sufficient output power to drive SIS mixers at 1 THz. It is considered that optical photomixer local oscillators have potential for driving hot electron bolometers above 1 THz.

Zmuidzinas, J.↗

A directional filter diplexer using optical techniques for millimeter to submillimeter wavelengths

An optical diplexer for injection of a local oscillator into a mixer, useful in the submillimeter and short millimeter range, is described. It has very low insertion loss for both the signal and local oscillator (LO) and high rejection of LO noise. The measured performance of a unit tested at 337 GHz indicates a loss of about 0.2 dB for both inputs and 20-dB noise rejection.

Erickson, N. R.↗

A Miniaturized Laser Heterodyne Radiometer for a Global Ground-Based Column Carbon Monitoring Network

We present progress in the development of a passive, miniaturized Laser Heterodyne Radiometer (mini-LHR) that will measure key greenhouse gases (C02, CH4, CO) in the atmospheric column as well as their respective altitude profiles, and O2 for a measure of atmospheric pressure. Laser heterodyne radiometry is a spectroscopic method that borrows from radio receiver technology. In this technique, a weak incoming signal containing information of interest is mixed with a stronger signal (local oscillator) at a nearby frequency. In this case, the weak signal is sunlight that has undergone absorption by a trace gas of interest and the local oscillator is a distributive feedback (DFB) laser that is tuned to a wavelength near the absorption feature of the trace gas. Mixing the sunlight with the laser light, in a fast photoreceiver, results in a beat signal in the RF. The amplitude of the beat signal tracks the concentration of the trace gas in the atmospheric column. The mini-LHR operates in tandem with AERONET, a global network of more than 450 aerosol sensing instruments. This partnership simplifies the instrument design and provides an established global network into which the mini-LHR can rapidly expand. This network offers coverage in key arctic regions (not covered by OCO-2) where accelerated warming due to the release of CO2 and CH4 from thawing tundra and permafrost is a concern as well as an uninterrupted data record that will both bridge gaps in data sets and offer validation for key flight missions such as OCO-2, OCO-3, and ASCENDS. Currently, the only ground global network that routinely measures multiple greenhouse gases in the atmospheric column is TCCON (Total Column Carbon Observing Network) with 18 operational sites worldwide and two in the US. Cost and size of TCCON installations will limit the potential for expansion, We offer a low-cost $30Klunit) solution to supplement these measurements with the added benefit of an established aerosol optical depth measurement. Aerosols induce a radiative effect that is an important modulator of regional carbon cycles. Changes in the diffuse radiative flux fraction (DRF) due to aerosol loading have the potential to alter the terrestrial carbon exchange.

Wilson, Emily L.↗

Phase coherent VLBI using a satellite link

The results from experiments using the Hermes (formerly CTS) communications satellite to provide a local oscillator and data link between two antennas are presented. The techniques used to compensate for the satellite motion and translation oscillator are described. Plans for a series of three station experiments to measure UT and polar motion using the ANIK-B satellite to synchronize the local oscillators are discussed.

Waltman, W. B.↗

Submillimeter-wave receivers - A status report

A development status assessment is presented for the work of U.S. and Western European research groups on heterodyne sub-mm receivers in the 300-1000 GHz frequency range. The applications driving sub-mm receiver and local oscillator source technologies are radio astronomy, atmospheric measurements, plasma diagnostics, and laboratory spectroscopy. Progress is concentrated in two areas, cooled Schottky diode mixers and solid state local oscillators employing frequency multipliers.

Wilson, W. J.↗

Mode Transitions in Hall Effect Thrusters

Mode transitions have been commonly observed in Hall Effect Thruster (HET) operation where a small change in a thruster operating parameter such as discharge voltage, magnetic field or mass flow rate causes the thruster discharge current mean value and oscillation amplitude to increase significantly. Mode transitions in a 6-kW-class HET called the H6 are induced by varying the magnetic field intensity while holding all other operating parameters constant and measurements are acquired with ion saturation probes and ultra-fast imaging. Global and local oscillation modes are identified. In the global mode, the entire discharge channel oscillates in unison and azimuthal perturbations (spokes) are either absent or negligible. Downstream azimuthally spaced probes show no signal delay between each other and are very well correlated to the discharge current signal. In the local mode, signals from the azimuthally spaced probes exhibit a clear delay indicating the passage of "spokes" and are not well correlated to the discharge current. These spokes are localized oscillations propagating in the ExB direction that are typically 10-20% of the mean value. In contrast, the oscillations in the global mode can be 100% of the mean value. The transition between global and local modes occurs at higher relative magnetic field strengths for higher mass flow rates or higher discharge voltages. The thrust is constant through mode transition but the thrust-to-power decreased by 25% due to increasing discharge current. The plume shows significant differences between modes with the global mode significantly brighter in the channel and the near-field plasma plume as well as exhibiting a luminous spike on thruster centerline. Mode transitions provide valuable insight to thruster operation and suggest improved methods for thruster performance characterization.

interplanetary exploration↗

Heterodyne detection of the 752.033-GHz H2O rotational absorption line

A tunable high resolution two stage heterodyne radiometer was developed for the purpose of investigating the intensity and lineshape of the 752.033 GHz rotational transition of water vapor. Single-sideband system noise temperatures of approximately 45,000 K were obtained using a sensitive GaAs Schottky diode as the first stage mixer. First local oscillator power was supplied by a CO2 laser pumped formic acid laser (761.61 GHz), generating an X-band IF signal with theoretical line center at 9.5744 GHz. Second local oscillator power was provided by means of a 3 GHz waveguide cavity filter with only 9 dB insertion loss. In absorption measurements of the H2O taken from a laboratory simulation of a high altitude rocket plume, the center frequency of the 752 GHz line was determined to within 1 MHz of the reported value. A rotational temperature 75 K, a linewidth 5 MHz and a Doppler shift 3 MHz were measured with the line-of-sight intersecting the simulated-plume axis at a distance downstream of 30 nozzle diameters. These absorption data were obtained against continuum background radiation sources at temperatures of 1175 and 300 K.

Dionne, G. F.↗

Mach-Zehnder optical configuration with Brewster window and two quarter-wave plates

Configuration is improvement because of the following: It provides higher efficiency. It reduces or eliminates feedthrough of untranslated local oscillator, which would produce a beat signal at shifted frequency of translator. When used without translator and with low-power detector, telescope secondary mirror reflects portion of output to local oscillator.

Lawrence, T. R.↗

A 492 GHz cooled Schottky receiver for radio-astronomy

We developed a 492 GHz cooled GaAs Schottky receiver driven by a solid state local oscillator with a DSB noise temperature of 550 K measured at the telescope. The receiver-bandwidth is approx. equal to 1.0 GHz. Quasi-optical mirrors focus the sky and local oscillator radiation into the mixer. Stability analysis via the Allan variance method shows that the total system including a 1 GHz bandwidth acousto-optical spectrometer built in Cologne allows integration times up to 100 sec per half switching cycle. We successfully used the receiver at the KOSMA 3 m telescope on Gornergrat (3150m) located in the central Swiss Alps near Zermatt during January-February 1992 for observations of the 492 GHz, (CI) (3)P1 to (3)P0 fine structure line in several galactic sources. These observations confirm that Gornergrat is an excellent winter submillimeter site in accordance with previous predictions based on the atmospheric opacity from KOSMA 345 GHz measurements.

Hernichel, J.↗

RF spectrometers for heterodyne receivers

Several types of spectrometers developed for radio astronomy receivers which utilize RF filters, multiple oscillators and mixers, digital autocorrelators and acoustic/optic devices are considered. The RF spectrometer developed at GSFC to provide wide bandwidths (greater than 1 GHz) as well as high resolution (5MHz) is described. The 128 channel filter bank is divided into high and low resolution sections. The high resolution section is tunable by providing a second mixer ahead of the filter bank. This is necessary because infrared receivers which use gas lasers as local oscillators are only tunable to specific laser frequencies. To compensate for astronomical Doppler shifts and molecule frequency differences a second local oscillator and mixer is needed. A diagram of the RF section of the filter bank is shown. The RF spectrometer is shown to be the best means of achieving ultra-wide bandwidths for infrared heterodyne receivers. For high resolution with a large number of channels, the acousto/optical spectrometer is the principle instrument, particularly for balloon or space flight applications.

Buhl, D.↗