Search NASA⌕ Search

SEARCH · Search NASA

Results for “logging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

SECARB Cranfield Well Logs

Borehole logs from the SECARB project at the Cranfield oil site in Franklin, Mississippi . Well logs are a part of the geologic characterization phase of SECARB; CFU 31F-1, CFU 31F-2, CFU 31F-3 well logs from Detailed Area of Study (DAS) and other well logs. Associated Publications: Butsch, R., Brown, A. L., Bryans, B., Kolb, C., Hovorka, S. D., 2013, Integration of well-based subsurface monitoring technologies: lessons learned at SECARB study, Cranfield, MS: International Journal of Greenhouse Gas Control https://doi.org/10.1016/j.ijggc.2013.06.010.

Borehole log↗

Utah FORGE: Well 14-2 Logs and Data from Roosevelt Hot Spring Area

This is a compilation of logs and data from Well 14-2 in the Roosevelt Hot Springs area in Utah. This well is also in the Utah FORGE study area. Data includes: flowmeter survey (1989), geochemistry (1977-1978, 1977-1983), injection test data (1979, 1982), and spinner surveys (1989, 1985-1986). Logs include: borehole compensated sonic and gamma ray (600'-6112'), borehole geometry and gamma ray (50'-4829'), caliper (0'-1720'), compensated neutron formation density (600'-6121'), induction electric (650'-6118'), mud log (79'-6100'), steam injection survey (50'-1175'), subsurface pressure surveys (0'-6087'), and subsurface temperature surveys (0'-6106'). The file is in a compressed .zip format and there is a data inventory table (Excel spreadsheet) in the root folder that is a guide to the data that is accessible in subfolders.

14-2↗

Flowing fluid electrical conductivity logging of a deep borehole during and following drilling: estimation of transmissivity, water salinity and hydraulic head of conductive zones

Flowing fluid electrical conductivity (FFEC) logging is a hydrogeologic testing method that is usually conducted in an existing borehole. However, for the 2,500-m deep COSC-1 borehole, drilled at Åre, central Sweden, it was done within the drilling period during a scheduled 1-day break, thus having a negligible impact on the drilling schedule, yet providing important information on depths of hydraulically conductive zones and their transmissivities and salinities. In this paper, we present a reanalysis of this set of data together with a new FFEC logging data set obtained soon after drilling was completed, also over a period of 1 day, but with a different pumping rate and water-level drawdown. Their joint analysis not only results in better estimates of transmissivity and salinity in the conducting fractures intercepted by the borehole, but also yields the hydraulic head values of these fractures, an important piece of information for the understanding of hydraulic structure of the subsurface. Two additional FFEC logging tests were done about 1 year later, and are used to confirm and refine this analysis. Results show that from 250 to 2,000 m depths, there are seven distinct hydraulically conductive zones with different hydraulic heads and low transmissivity values. For the final test, conducted with a much smaller water-level drawdown, inflow ceased from some of the conductive zones, confirming that their hydraulic heads are below the hydraulic head measured in the wellbore under non-pumped conditions. Lastly, the challenges accompanying 1-day FFEC logging are summarized, along with lessons learned in addressing them.

58 GEOSCIENCES↗

Boron-coated straw neutron detector for well-logging-Final Technical Report

The Oil & Gas exploration industry makes extensive use of radiation detectors for well logging – a geologic formation map that reveals crucial information for the viability of oil/gas extraction in surveyed wells. Helium-3 gas filled neutron detectors have been the gold standard for neutron porosity logs, one of two components in nuclear logging (gamma ray logs being the other component). The finite supply of 3He gas has dwindled in recent years due to an increased use in Homeland Security applications; therefore the need for alternative technologies that would ensure oil & gas exploration for coming years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Logging Crew Attributes by Region in the Southeast USA

Urbanization, shrinking markets, and reduced forestry investment may affect harvesting efficiency in regions of the US South. To monitor these conditions, logging businesses have been tracked by surveys conducted by universities and trade associations. This project used a sampling approach coordinated with FIA utilization studies to sample logging crews based on a harvesting location. The approach was used to develop relationships among firm attributes and site attributes in six southeastern states (AL, GA, FL, NC, SC, and VA) from 2011 to 2018. The data included harvest attributes (location, harvest size and stand type) and logging firm attributes (production, crew labor, crew number, the number of machines by type, and machine age). For crew capital value, an equation was developed for this study using machine number and average machine age. The data from logging crews on 419 harvests were analyzed by region, harvest size, and stand type. Mean values for crew labor ranged from 3.1 to 7.1 workers. The average capital value per crew ranged from $\$220,000$ to $\$524,000$ per crew in the Coastal Plain with a narrower range in the Piedmont. In the Coastal Plain, higher productivity was detected for larger harvests and pine versus hardwood and mixed stands; however, in the Piedmont those trends were less obvious. Ratio of feller-bunchers, skidders and loaders were mostly 1:1:1 or 1:2:1 with 41% and 24% of samples, respectively. There were notable trends among Coastal Plain loggers regarding capital value and productivity with evidence supported by a production function. The differences in Piedmont (e.g., ownership size, market access, terrain, population density, etc.) may combine to limit daily production and labor productivity.

54 ENVIRONMENTAL SCIENCES↗

A THEORETICAL AND EXPERIMENTAL INVESTIGATION OF FLUSH MOUNTING CONFIGURATIONS FOR LOG PERIODIC STRUCTURES

Many types of log periodic structures have been described in the literature; but, as far as is known, flush-mounted log periodic antennas have not been studied heretofore. The purpose of this study is to investigate, primarily by experimental methods, the input impedance and radiation characteristics of a particular type of log periodic antenna when flush-mounted over a suitable cavity or recess in a conducting surface. The particular type of log periodic antenna chosen for use in the investigation is referred to as a monopole-tooth antenna and is described in detail in Part II of the report. A suitable cavity over which the monopole-tooth antenna may be mounted is described in Part III, and experimentally determined characteristics of the antenna-cavity assembly are presented in Part IV. The first objective of the study was to obtain an optimum or nearoptimum design of the antenna-cavity assembly. This objective has been reached within the limits of the experimental approach, and the results obtained are summarized in Part V of the report. A second objective, which will be reported upon at a future date, is to establish optimum design criteria and performance characteristics of the antenna-cavity assembly when the cavity is filled with low-loss dielectric material.

RADIATION FUNCTION↗

When Workflow Management Systems and Logging Systems Meet: Analyzing Large-Scale Execution Traces

This poster shows the benefits of integrating a workflow management system with logging and log mining capabilities. By combing two existing, mature technologies: Pegasus-WMS and Netlogger, we are able to efficiently process execution logs of earthquake science workflows consisting of hundreds of thousands to one million tasks. In particular we show results of processing logs of CyberShake, a workflow application running on the TeraGrid. Client-side tools allow scientists to quickly gather statistics about a workflow run and find out which tasks executed, where they were executed, what was their runtime, etc. These statistics can be used to understand the performance characteristics of a workflow and help tune the execution parameters of the workflow management system. This poster shows the scalability of the system presenting results of uploading task execution records into the system and by showing results of querying the system for overall workflow performance information.

97 MATHEMATICS AND COMPUTING↗

Combined Structural Analysis of Core and Image Log of TGH 76-31 South East of Mt Baker, Washington State

Despite active volcanism, few geothermal energy resources have been developed in the Cascades Range. Temperature Gradient Hole 76-31 was drilled to ~440 m measured depth to probe for zones where fractures provide fluid conduits that transport deep volcanic heat to shallow depths that could support baseload, carbon neutral electrical generation. These zones were predicted by a Play Fairway assessment (PFA) of resource potential along a zone 11 km west-southwest of the summit of Mount Baker Volcano. Rock core, temperature logs, and an acoustic image log were obtained. By comparison to outcrops, the core has been initially interpreted as the Chilliwack group comprised of partially metamorphosed basaltic to andesitic volcanics. Core mapping reveals complex, steeply dipping networks of fractures and brecciation along slickensided strike slip faults; clay alteration is common in many of these structures. The majority of fractures are thoroughly healed by layers of chlorite and calcite; preservation of pyrite indicates anoxic conditions. The majority of fracture porosity resides in very dense fractures a few centimeters or less in length. The image log provides good insights into attitude of fractures that fully transect the core, but generally underestimates fracture density. The combination of complex, non-planar fracture zones containing many short fractures and healing promote misinterpretation of natural fracture attitude and density in the image log. The healing and anoxic minerals are consistent with the conductive temperature gradient measured in the well below a shallow isothermal zone, although, several fractures are open or only partially healed and resulted in fluid entries into the well. Here, the equilibrated measured temperature gradient of 64ºC/km and calculated heat flow of 145 mW/m2 is more than twice the regional average, indicating local influence of the Mt Baker magmatic system at the Little Park Creek TGH site.

Cascades↗

SLoG: Large-Scale Logging Middleware for HPC and Big Data Convergence

Cloud developers traditionally rely on purpose-specific services to provide the storage model they need for an application. In contrast, HPC developers have a much more limited choice, typically restricted to a centralized parallel file system for persistent storage. Unfortunately, these systems often offer low performance when subject to highly concurrent, conflicting I/O patterns. This makes difficult the implementation of inherently concurrent data structures such as distributed shared logs. Yet, this data structure is key to applications such as computational steering, data collection from physical sensor grids, or discrete event generators. In this paper we tackle this issue. We present SLoG, shared log middleware providing a shared log abstraction over a parallel file system, designed to circumvent the aforementioned limitations. We evaluate SLoG’s design on up to 100,000 cores of the Theta supercomputer: the results show high append velocity at scale while also providing substantial benefits for other persistent backend storage systems.

big data↗

Fallon FORGE: Well 21-31 Wireline Logs

Included are the following wireline logs from the Fallon FORGE Well 21-31: Ormat_Forge 21-31_8.5 inch section: FMI data in PDF and DLIS formats; MSCT data in PDF format; Pressure and Temperature data in PDF, LAS, and DLIS formats; Sonic Scanner data in PDF, DLIS, and LAS formats (LAS format contains Stoneley Slowness, Shear Slowness, and Compressional Slowness logs); Triple Combo in PDF, DLIS, and LAS formats; and USIT data in DLIS and PDF formats. Ormat_Forge_21-31_12.25 inch section: Resistivity data in PDF and LAS formats; Sonic Scanner data in PDF, DLIS, and LAS formats (LAS format contains Stoneley Slowness, Shear Slowness, and Compressional Slowness logs); Triple Combo in PDF and LAS formats; and Caliper data in PDF format (DLIS format for caliper data is included in the Sonic Scanner DLIS).

15 GEOTHERMAL ENERGY↗

Fallon FORGE: Well Log Database

Master well database for all logs and other well data pertaining to the Fallon FORGE site. Tables are formatted in NGDS Teir 3 schema where appropriate; redundancies between tables are omitted, and should be queried off of the main WellHeader table. All relationships are set on the "HeaderURI" primary key. Tables: WellHeader - well locations and information ChemFluid - aqueous chemistry analyses ChemRock - rock chemistry analyses DensityCore - rock densities from core FracturesInduced - induced borehole fractures FracturesNatural - natural borehole factures LithIntercepts - lithology picks from cuttings and core MagSuscCore - magnetic susceptibility for core samples MagSuscPmag - magnetic susceptibility for pmag samples PTSLogs - pressure-temperature-spin logs WirelineLogs - digital wireline logs (21-31 only)

15 GEOTHERMAL ENERGY↗

Informing Plant Asset Reliability and Availability Through AI-Driven Analysis of Operator Logs

The availability and reliability of nuclear power plant (NPP) structures, systems, and components (SSCs) are critical parameters for NPP safety. Tracking these parameters is necessary but costly and labor-intensive, requiring the collection and evaluation of SSC event data such as shutdowns, startups, and failures. To show how these events are needed for the parameters an example is given: one measure of reliability is based on the number of equipment failure events and the number of run hours (i.e., the time from a startup event to a shutdown event). Here, this work investigates using artificial intelligence (AI) to mine NPP operator log entry texts for SSC event data. Four AI approaches were explored for identifying these events, including natural language processing (NLP) methods, generative AI, generative AI combined with NLP, and topic modeling. A key challenge addressed with all four approaches is the brevity of operator log entries. Among these four a neural network–based NLP method was shown to be the most promising for this application, achieving F1 scores of 86.0% for shutdowns, 92.2% for startups, and 80.4% for failures on a subject-matter-expert-curated dataset from NPP operator logs, compared to a baseline of 66.6% for a random classifier. This shows that NLP methods can perform better than generative AI. Additionally, the NLP methods combined with generative AI were shown to perform better than generative AI alone. Generative AI was most successful at providing the background information for the NLP methods to use. This work demonstrates the potential to use AI to automate parameter collection from NPP operator log entries and other records.

97 - MATHEMATICS AND COMPUTING↗

FTLADS: Object-Logging Based Fault-Tolerant Big Data Transfer System Using Layout Aware Data Scheduling

The layout-aware data scheduling (LADS) data movement framework optimizes congestion for end-to-end data transfers. During data transfer, LADS can avoid congested storage elements by exploiting the underlying storage layout at each endpoint. This improves the I/O bandwidth and hence the data transfer rate across high-speed networks. However, the absence of fault tolerance (FT) in LADS results in data retransmission overhead and may lead to possible data integrity issues upon faults. In this paper, we propose object-logging FT mechanisms to avoid transmitting the objects that are successfully written into the parallel file system (PFS) at the sink end. Depending on the number of log files created for the whole dataset, we have classified our FT mechanisms into three different categories: file logger, transaction logger, and universal logger. Also, to address the space overhead, we have proposed different methods of populating the log files with the information of the successfully transferred objects. We have evaluated the data transfer performance and recovery time overhead of the proposed object-logging-based FT mechanisms on the LADS data transfer framework. Our experimental results reflect that FT mechanisms exhibit negligible overhead (<; 1%) with respect to the data transfer time. Yet, the fault recovery time is 10% higher than the total data transfer time at any fault point.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-784: Using MLC Log Files for Daily IMRT Delivery Verification

Purpose: To verify daily intensity modulated radiation therapy (IMRT) treatments using multi-leaf collimator (MLC) log files. Methods: The MLC log files from a NovalisTX Varian linear accelerator were used in this study. The MLC files were recorded daily for all patients undergoing IMRT or volumetric modulated arc therapy (VMAT). The first record of each patient was used as reference and all records for subsequent days were compared against the reference. An in house MATLAB software code was used for the comparisons. Each MLC log file was converted to a fluence map (FM) and a gamma index (γ) analysis was used for the evaluation of each daily delivery for every patient. The tolerance for the gamma index was set to 2% dose difference and 2mm distance to agreement while points with signal of 10% or lower of the maximum value were excluded from the comparisons. Results: The γ between each of the reference FMs and the consecutive daily fraction FMs had an average value of 99.1% (ranged from 98.2 to 100.0%). The FM images were reconstructed at various resolutions in order to study the effect of the resolution on the γ and at the same time reduce the time for processing the images. We found that the comparison of images with the highest resolution (768×1024) yielded on average a lower γ (99.1%) than the ones with low resolution (192×256) (γ 99.5%). Conclusion: We developed an in-house software that allows us to monitor the quality of daily IMRT and VMAT treatment deliveries using information from the MLC log files of the linear accelerator. The information can be analyzed and evaluated as early as after the completion of each daily treatment. Such tool can be valuable to assess the effect of MLC positioning on plan quality, especially in the context of adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-R-12: Prediction of TrueBeam Hardware Issues Using Trajectory Log Analysis

Purpose: To predict potential failures of hardware within the Varian TrueBeam linear accelerator in order to proactively replace parts and decrease machine downtime. Methods: Machine downtime is a problem for all radiation oncology departments and vendors. Most often it is the result of unexpected equipment failure, and increased due to lack of in-house clinical engineering support. Preventative maintenance attempts to assuage downtime, but often is ineffective at preemptively preventing many failure modes such as MLC motor failures, the need to tighten a gantry chain, or the replacement of a jaw motor, among other things. To attempt to alleviate downtime, software was developed in house that determines the maximum value of each axis enumerated in the Truebeam trajectory log files. After patient treatments, this data is stored in a SQL database. Microsoft Power BI is used to plot the average maximum error of each day of each machine as a function of time. The results are then correlated with actual faults that occurred at the machine with the help of Varian service engineers. Results: Over the course of six months, 76,312 trajectory logs have been written into the database and plotted in Power BI. Throughout the course of analysis MLC motors have been replaced on three machines due to the early warning of the trajectory log analysis. The service engineers have also been alerted to possible gantry issues on one occasion due to the aforementioned analysis. Conclusion: Analyzing the trajectory log data is a viable and effective early warning system for potential failures of the TrueBeam linear accelerator. With further analysis and tightening of the tolerance values used to determine a possible imminent failure, it should be possible to pinpoint future issues more thoroughly and for more axes of motion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-230: A Simple Method to Assess Accuracy of Dynamic Wave Arc Irradiation Using An Electronic Portal Imaging Device and Log Files

Purpose: The Dynamic Wave Arc (DWA) technique, where the multi-leaf collimator (MLC) and gantry/ring move simultaneously in a predefined non-coplanar trajectory, has been developed on the Vero4DRT. The aim of this study is to develop a simple method for quality assurance of DWA delivery using an electronic portal imaging device (EPID) measurements and log files analysis. Methods: The Vero4DRT has an EPID on the beam axis, the resolution of which is 0.18 mm/pixel at the isocenter plane. EPID images were acquired automatically. To verify the detection accuracy of the MLC position by EPID images, the MLC position with intentional errors was assessed. Tests were designed considering three factors: (1) accuracy of the MLC position (2) dose output consistency with variable dose rate (160–400 MU/min), gantry speed (2.4–6°/s), ring speed (0.5–2.5°/s), and (3) MLC speed (1.6–4.2 cm/s). All the patterns were delivered to the EPID and compared with those obtained with a stationary radiation beam with a 0° gantry angle. The irradiation log, including the MLC position and gantry/ring angle, were recorded simultaneously. To perform independent checks of the machine accuracy, the MLC position and gantry/ring angle position were assessed using log files. Results: 0.1 mm intentional error can be detected by the EPID, which is smaller than the EPID pixel size. The dose outputs with different conditions of the dose rate and gantry/ring speed and MLC speed showed good agreement, with a root mean square (RMS) error of 0.76%. The RMS error between the detected and recorded data were 0.1 mm for the MLC position, 0.12° for the gantry angle, and 0.07° for the ring angle. Conclusion: The MLC position and dose outputs in variable conditions during DWA irradiation can be easily detected using EPID measurements and log file analysis. The proposed method is useful for routine verification. This research is (partially) supported by the Practical Research for Innovative Cancer Control (15Ack0106151h0001) from Japan Agency for Medical Research and development, AMED. Authors Takashi Mizowaki and Masahiro Hiraoka have consultancy agreement with Mitsubishi Heavy Industries, Ltd., Japan.

60 APPLIED LIFE SCIENCES↗