Electrodynamic tether experiments in the ionosphere

The physical concepts of the space shuttle-borne electrodynamic tether experiment are reviewed, and the engineering realization of the deployment system for the first electrodynamic tether system is described. Models of the mechanisms involved in closing the current loop ionosphere - collector - tether - shuttle - ionosphere are discussed in terms of measurements to verify the models. Application of the electrodynamic tether to power generation and wave stimulation is considered. The characteristics of the instrumentation required on the deployed collector and on the space shuttle are addressed, and the flight operations necessary to demonstrate the capabilities of the electrodynamic tether are treated.

Raitt, W. J.↗

Non-contacting electromagnetic de-spin system for Earth orbiting satellites

A study of electromagnetic satellite de-spin system for orbiting satellites was conducted. Exact closed form solutions for the interacting magnetic flux have been formulated both for the case of the current loop and the bar magnet. The magnet system has been extended to the case of a U shaped magnet. Magnet design details are outlined. Computer simulation of the interacting flux density profile has been attempted. Data for the de-spin times has been extended to higher rpms.

Kadaba, P. K.↗

Remote sensing of chlorophyll concentrations in the northern Gulf of Mexico

During a 17 month period (November 1978 - March 1980), phytoplankton pigment concentrations were remotely sensed in the northern Gulf of Mexico using the Coastal Zone Color Scanner (CZCS). A total of 29 CZCS orbits were processed into pigment (chlorophyll a + phaeopigments) images and then geometrically warped to a Mercator projection. A correction factor of 1.67 was applied to the pigment concentrations to correct for the tendency of the standard fluorometric method to underestimate chlorophyll a concentrations. The spatial and temporal distributions of pigment fronts were quite variable during this time series. Constant features observed throughout the pigment imagery were the entrainment of coastal waters offshore. The most extensive entrainments occurred during intrusions of the Loop Current. For the 17 month survey, the mean HPLC-corrected pigment concentration was 3.30 + or - 1.45 mg/cu m.

Trees, Charles C.↗

Mesoscale air-sea interactions related to tropical and extratropical storms in the Gulf of Mexico

Observations of the lower atmosphere of the northwestern Gulf of Mexico from November 1982 to mid-February 1983 were studied in which seven significant cyclones were generated in the northwestern gulf. It was found that all seven storms occurred when the vorticity correlate of the horizontal air temperature difference was about 3-5 C above the climatological mean difference. It is shown that a maximum in the frequency of tropical storms within the Gulf of Mexico exists some 275 km south of the Mississippi delta at 27 deg N, 90 deg W. This maximum is a result of only those storms which originate within the gulf. Two plausible effects of the Loop Current and its rings on tropical storms are discussed. One is that these ocean features are large and consolidated heat and moisture sources from which a nearby slowly moving atmospheric disturbance can extract energy. The second is that of the cyclonic vorticity that can be generated in the lower atmosphere by such oceanographic features.

Lewis, James K.↗

Electron-Tunneling Magnetometer

Electron-tunneling magnetometer is conceptual solid-state device operating at room temperature, yet offers sensitivity comparable to state-of-art magnetometers such as flux gates, search coils, and optically pumped magnetometers, with greatly reduced volume, power consumption, electronics requirements, and manufacturing cost. Micromachined from silicon wafer, and uses tunneling displacement transducer to detect magnetic forces on cantilever-supported current loop.

Kaiser, William J.↗

SAR observations in the Gulf of Mexico

The Gulf of Mexico (GOM) exhibits a wealth of energetic ocean features; they include the Loop Current with velocities of about 2 m/s and strong shear fronts, mesoscale eddies, double vortices, internal waves, and the outflow of the 'Mighty Mississippi' river. These energetic features can have a strong impact on the economies of the states surrounding the Gulf. Large fisheries, oil and gas production as well as pollution transport are relevant issues. These circulation features in the Gulf are invisible to conventional IR and visible satellite imagery during the Summer months due to cloud cover and uniform surface temperatures. Synthetic Aperture Radar (SAR) imagery of the Gulf does penetrate the cloud cover and shows a rich assembly of features there year-round. Below are preliminary results from GOM SAR imagery taken by SEASAT in 1978 and by the AIRSAR program in 1991.

Sheres, David↗

Is the magnetosphere a lens for MHD waves?

A viewpoint of the magnetosphere as a lens for MHD waves is presented. Using a simple model of the variation of the Alfven speed as proportional to the local magnetic value given by the Earth's dipole field and that due to the magnetopause currents represented by a current loop, it is found that the near-Earth magnetotail, in the range 8-16 R(sub E), is the focus of the magnetospheric lens. This location is found to be quite insensitive to a wide variation of parameters. By using simple diffraction theory analysis it is found that the focal region extends about 1 R(sub E) about the neutral sheet in the north-south plane and 0.2 - 0.5 R(sub E) along the Sun-Earth line. Compressive MHD waves carried by the solar wind or created by the interaction of the wind with the magnetopause can be amplified by a factor of about 100 in the focal region and this has potentially important implications to substorm activity.

Papadopoulos, K.↗

Effect of Combined Spaceborne Microwave and Continuous Lightning Measurements on Precipitation Forecasts of the 1998 Ground-Hog Day Storm

We evaluated the impact of several newly available sources of meteorological data on mesoscale model forecasts of precipitation produced by the extra-tropical cyclone that struck Florida on February 2, 1998. Precipitation distributions of convective rainfall events were derived from Special Sensor Microwave Imager (SSM/I) and Multi-Channel Passive Microwave Sensor (TMI) microwave radiometric data by means of the Goddard PROFiling (GPROF) algorithm. Continuous lightning distributions were obtained from sferics measurements obtained from a network of VLF radio receivers. Histograms of coincident sferics frequency distributions were matched to those of precipitation to derive bogus convective rainfall rates from the continuously available sferics measurements. SSM/I and TMI microwave data were used to derive Integrated Precipitable Water (IPW) distributions. The TMI also provided sea surface temperatures (SSTS) of the Loop Current and Gulf Stream with improved structural detail. A series of experiments assimilated IPW and latent heating from the bogus convective rainfall for six-hours in the MM5 mesoscale forecast model to produce nine-hour forecasts of all rainfall as well as other weather parameters. Although continuously assimilating latent heating only slightly improved the surface pressure distribution forecast, it significantly improved the precipitation forecasts. Correctly locating convective rainfall was found critical for assimilating latent heating in the forecast model, but measurement of the rainfall intensity proved to be less important. The improved SSTs also had a positive impact on rainfall forecasts for this case. Assimilating bogus rainfall in the model produced nine-hour forecasts of radar reflectivity distributions that agreed well with coincident observations from the TRMM spaceborne precipitation radar, ground based radar and spaceborne microwave measurements.

Weinman, James A.↗

Enthalpy By Energy Balance for Aerodynamic Heating Facility at NASA Ames Research Center Arc Jet Complex

The NASA Ames Research Center (ARC) Arc Jet Facilities' Aerodynamic Heating Facility (AHF) has been instrumented for the Enthalpy By Energy Balance (EB2) method. Diagnostic EB2 data is routinely taken for all AHF runs. This paper provides an overview of the EB2 method implemented in the AHF. The chief advantage of the AHF implementation over earlier versions is the non-intrusiveness of the instruments used. For example, to measure the change in cooling water temperature, thin film 1000 ohm Resistance Temperature Detectors (RTDs) are used with an Anderson Current Loop (ACL) as the signal conditioner. The ACL with 1000 ohm RTDs allows for very sensitive measurement of the increase in temperature (Delta T) of the cooling water to the arc heater, which is a critical element of the EB2 method. Cooling water flow rates are measured with non-intrusive ultrasonic flow meters.

Hightower, T. Mark↗

Solar Array Sails: Possible Space Plasma Environmental Effects

An examination of the interactions between proposed "solar sail" propulsion systems with photovoltaic energy generation capabilities and the space plasma environments. Major areas of interactions ere: Acting from high voltage arrays, ram and wake effects, V and B current loops and EMI. Preliminary analysis indicates that arcing will be a major risk factor for voltages greater than 300V. Electron temperature enhancement in the wake will be produce noise that can be transmitted via the wake echo process. In addition, V and B induced potential will generate sheath voltages with potential tether like breakage effects in the thin film sails. Advocacy of further attention to these processes is emphasized so that plasma environmental mitigation will be instituted in photovoltaic sail design.

Mackey, Willie R.↗

Improved Sensing Coils for SQUIDs

An improvement in the design and fabrication of sensing coils of superconducting quantum interference device (SQUID) magnetometers has been proposed to increase sensitivity. It has been estimated that, in some cases, it would be possible to increase sensitivity by about half or to reduce measurement time correspondingly. The pertinent aspects of the problems of design and fabrication can be summarized as follows: In general, to increase the sensitivity of a SQUID magnetometer, it is necessary to maximize the magnetic flux enclosed by the sensing coil while minimizing the self-inductance of this coil. It is often beneficial to fabricate the coil from a thicker wire to reduce its self-inductance. Moreover, to optimize the design of the coil with respect to sensitivity, it may be necessary to shape the wire to other than a commonly available circular or square cross-section. On the other hand, it is not practical to use thicker superconducting wire for the entire superconducting circuit, especially if the design of a specific device requires a persistent-current loop enclosing a remotely placed SQUID sensor. It may be possible to bond a thicker sensing-coil wire to thinner superconducting wires leading to a SQUID sensor, but it could be difficult to ensure reliable superconducting connections, especially if the bonded wires are made of different materials. The main idea is to mold the sensing coil in place, to more nearly optimum cross sectional shape, instead of making the coil by winding standard pre-fabricated wire. For this purpose, a thin superconducting wire loop that is an essential part of the SQUID magnetometer would be encapsulated in a form that would serve as a mold. A low-melting-temperature superconducting metal (e.g., indium, tin, or a lead/tin alloy) would be melted into the form, which would be sized and shaped to impart the required cross section to the coil thus formed.

Penanen, Konstantin↗

Measurement and Control of Oxygen Partial Pressure in an Electrostatic Levitator

Recently the NASA Marshall Space Flight Center electrostatic levitation (ESL) laboratory has been upgraded to include an oxygen control system. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled, at elevated temperatures, theoretically in the range from 10(exp -36) to 10(exp 0) bar. The role of active surface agents in liquid metals is fairly well known; however, published surface tension data typically has large scatter, which has been hypothesized to be caused by the presence of oxygen. The surface tension of metals is affected by even a small amount of adsorption of oxygen. It has even been shown that oxygen partial pressures may need to be as low as 10(exp -24) bar to avoid oxidation. While electrostatic levitation is done under high vacuum, oxide films or dissolved oxygen may have significant effects on materials properties, such as surface tension and viscosity. Therefore, the ability to measure and control the oxygen partial pressure within the chamber is highly desirable. The oxygen control system installed at MSFC contains a potentiometric sensor, which measures the oxygen partial pressure, and an oxygen ion pump. In the pump, a pulse-width modulated electric current is applied to yttrium-stabilized zirconia, resulting in oxygen transfer into or out of the system. Also part of the system is a control unit, which consists of temperature controllers for the sensor and pump, PID-based current loop for the ion pump, and a control algorithm. This system can be used to study the effects of oxygen on the thermophysical properties of metals, ceramics, glasses, and alloys. It can also be used to provide more accurate measurements by processing the samples at very low oxygen partial pressures. The oxygen control system will be explained in more detail and an overview of its use and limitations in an electrostatic levitator will be described. Some preliminary measurements have been made, and the results to date will be provided.

SanSoucie, Michael P.↗

Effects of Oxygen Partial Pressure on the Surface Tension of Liquid Nickel

The NASA Marshall Space Flight Center's electrostatic levitation (ESL) laboratory has been recently upgraded with an oxygen partial pressure controller. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled, theoretically in the range from 10‐36 to 100 bar. The oxygen control system installed in the ESL laboratory's main chamber consists of an oxygen sensor, oxygen pump, and a control unit. The sensor is a potentiometric device that determines the difference in oxygen activity in two gas compartments (inside the chamber and the air outside of the chamber) separated by an electrolyte, which is yttria‐stabilized zirconia. The pump utilizes coulometric titration to either add or remove oxygen. The system is controlled by a desktop control unit, which can also be accessed via a computer. The controller performs temperature control for the sensor and pump, PID-based current loop, and a control algorithm. Oxygen partial pressure has been shown to play a significant role in the surface tension of liquid metals. Oxide films or dissolved oxygen may lead to significant changes in surface tension. The effects of oxygen partial pressure on the surface tension of undercooled liquid nickel will be analyzed, and the results will be presented. The surface tension will be measured at several different oxygen partial pressures while the sample is undercooled. Surface tension will be measured using the oscillating drop method. While undercooled, each sample will be oscillated several times consecutively to investigate how the surface tension behaves with time while at a particular oxygen partial pressure.

SanSoucie, Michael P.↗

High Performance Torso Cooling Garment

The concept proposed in this paper is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area, which could facilitate removal of LCVG tubing from the arms and legs, thereby increasing suited crew member mobility. EVA space suit mobility in micro-gravity is challenging, and it becomes even more challenging in the gravity of Mars. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased. This increase in efficiency could provide the required liquid cooling via torso tubing only; no arm or leg LCVG tubing would be required. Benefits of this approach include increased crewmember mobility, reduced LCVG mass, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development. This report describes analysis and test activities performed to evaluate the potential improvements to the thermal performance of the LCVG. Analyses evaluated potential tube shapes for improving the thermal performance of the LCVG. The analysis results fed into the selection of flat flow strips to improve thermal contact with the skin of the suited test subject. Testing of small segments was performed to compare thermal performance of the tubing approach of the current LCVG to the flat flow strips proposed as the new concept. Results of the testing is presented along with recommendations for future development of this new concept.

Conger, Bruce↗

High Performance Torso Cooling Garment

The concept proposed in this paper is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area, which could facilitate removal of LCVG tubing from the arms and legs, thereby increasing suited crew member mobility. EVA space suit mobility in micro-gravity is challenging, and it becomes even more challenging in the gravity of Mars. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased. This increase in efficiency could provide the required liquid cooling via torso tubing only; no arm or leg LCVG tubing would be required. Benefits of this approach include increased crewmember mobility, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development. This report describes analysis and test activities performed to evaluate the potential improvements to the thermal performance of the LCVG. Analyses evaluated potential tube shapes for improving the thermal performance of the LCVG. The analysis results fed into the selection of flat flow strips to improve thermal contact with the skin of the suited test subject. Testing of small segments was performed to compare thermal performance of the tubing approach of the current LCVG to the flat flow strips proposed as the new concept. Results of the testing is presented along with recommendations for future development of this new concept.

Conger, Bruce↗

Development and Calibration of a Field-Deployable Microphone Phased Array for Propulsion and Airframe Noise Flyover Measurements

A new aeroacoustic measurement capability has been developed consisting of a large channelcount, field-deployable microphone phased array suitable for airframe noise flyover measurements for a range of aircraft types and scales. The array incorporates up to 185 hardened, weather-resistant sensors suitable for outdoor use. A custom 4-mA current loop receiver circuit with temperature compensation was developed to power the sensors over extended cable lengths with minimal degradation of the signal to noise ratio and frequency response. Extensive laboratory calibrations and environmental testing of the sensors were conducted to verify the design's performance specifications. A compact data system combining sensor power, signal conditioning, and digitization was assembled for use with the array. Complementing the data system is a robust analysis system capable of near real-time presentation of beamformed and deconvolved contour plots and integrated spectra obtained from array data acquired during flyover passes. Additional instrumentation systems needed to process the array data were also assembled. These include a commercial weather station and a video monitoring / recording system. A detailed mock-up of the instrumentation suite (phased array, weather station, and data processor) was performed in the NASA Langley Acoustic Development Laboratory to vet the system performance. The first deployment of the system occurred at Finnegan Airfield at Fort A.P. Hill where the array was utilized to measure the vehicle noise from a number of sUAS (small Unmanned Aerial System) aircraft. A unique in-situ calibration method for the array microphones using a hovering aerial sound source was attempted for the first time during the deployment.

Humphreys, William M., Jr.↗

Development of a Field-Deployable Microphone Phased Array for Airframe Noise Flyover Measurements

This technical memorandum describes in detail the construction and use of a large channel-count, field-deployable microphone phased array designed for airframe noise flyover measurements for a range of aircraft types and scales. The array incorporated 185 hardened, weather-resistant sensors suitable for outdoor use. A custom 4-mA current loop receiver circuit with temperature compensation was developed to power the sensors over extended cable lengths with minimal loss of signal-to-noise. Extensive calibrations and performance testing of the sensors were conducted to verify the design specifications. A compact data system combining sensor power, signal conditioning, and digitization was assembled for use with the array. Complementing the data system was a robust analysis system capable of near real-time presentation of beamformed and deconvolved contour plots and integrated spectra obtained from data acquired during flyover passes of the array. Additional instrumentation systems needed to process the array data were also developed, including a commercial 10-meter weather station comprised of a sonic anemometer, aspirated temperature/humidity probe and pressure sensor. Unique methods for assessing the health of the array in-situ were developed and demonstrated. A detailed mock-up of the instrumentation suite (phased array, weather station, and data processor) was performed in the NASA Langley Acoustic Development Laboratory in 2014 to vet the system performance. Issues with the sensors and electronics were identified during the mock-up and subsequently corrected. The array was then deployed for preliminary field testing at Fort A.P. Hill in Virginia in 2015 followed by the array being utilized in three separate full-scale airframe noise test campaigns at Edwards Air Force Base in California from 2016 to 2018 where the system was used to characterize the noise generated by both baseline and treated flaps and main landing gear on a commercial transport-sized vehicle.

Phased Array↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System: Preprint

This paper develops improved control strategy of GFM inverter with fault ride-through (FRT) capabilities to guarantee stable operation of microgrid under fault conditions especially islanded microgrid and asymmetrical faults. The proposed control strategy includes dual control of positive-sequence and negative-sequence control, and the adaptive virtual impedance (VI) control. Unlike the existing works, the proposed strategy only applies the VI control for the d-component of the positive-sequence control and leaves the q-component of positive-sequence control and dq-component of negative-sequence control zero, thus achieving the improved stability and balanced three-phase voltage under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults which could cause saturated inner current loop and instability if the VI is not adaptive. Simulation results of a phase-to-phase-ground fault show that the proposed control strategy improves the stability of GFM and achieves the stable and balanced output voltages in islanded microgrid.