Cherenkov and Transition Radiation as Low-Energy Background Sources in SuperCDMS Detectors

The Weakly Interacting Massive Particle (WIMP) has historically been a prime candidate for dark matter due to its elegant compatibility with the Minimally Supersymmetric Standard Model (MSSM). Recent dark matter experiments have ruled out much of the GeV-TeV mass range predicted by the MSSM, however, and the newest generation of direct detection experiments, such as SuperCDMS SNOLAB, have begunto explore sub-GeV dark matter. As experiments push towards lower masses, sensitivity to eV-scale electron recoil events has become increasingly important. A variety of unexplained excesses at energy deposits of 1-100 eV have been found inmany such low-mass experiments, across different detection techniques and at different excess rates. These low-energy events are not thought to be dark matter, and they must be understood and effectively removed to further improve detector energy resolution. This thesis will outline the simulation of one possible source of low-energy excess at SuperCDMS: optical photons produced from charges in uniform motion, specifically from Cherenkov radiation (CR), transition radiation (TR), and the intermediate hybrid transition-Cherenkov radiation (HR). In the latter case, the standard formulae for HR contain divergences at certain angles in transparent media, which are an artifact of their derivation and become problematic to simulate. To rsolve this, we present a novel approach to normalize the divergent HR peaks, which allows HR to transition smoothly between TR and CR in a numerical simulation. We also add TR and CR as a physics process to the SuperCDMS Monte Carlo simulation package SuperSim, based on the Geant4 simulation toolkit. To verify the physics of our addition, we show some test simulations in comparison to theoretical predictions of optical radiation intensity. We also use the simulation to make some preliminary predictions on the contribution of TR and CR to the low energy background, with the expectation that more thorough analyses will be conducted in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ge:Ga and Ge:Be photoconductive detectors for far infrared astronomy from a space platform

The paper describes some of the development work on gallium-doped germanium (Ge:Ga) and beryllium-doped germanium (Ge:Be) photoconductive detectors for use in far-infrared astronomical observations from a space platform such as IRAS. The paper is concerned primarily with detector performance and is divided into two major parts. The first presents the operating principles of this type of detector, while the second presents measured performance data under low-background flux conditions. It is shown that high sensitivity can be obtained from Ge:Ga and Ge:Be detectors under low-background and low-temperature conditions of operation. These detectors are useful for astronomical observations in the far-infrared over the wavelength range 30-120 microns. Major conclusions of the research work done so far are mentioned, including that detectors cut from the same crystal show reasonably good reproducibility of operating characteristics.

Bratt, P. R.↗

Cherenkov photon background for low-noise silicon detectors in space

Future space observatories dedicated to direct imaging and spectroscopy of extra-solar planets will require ultra-low-noise detectors that are sensitive over a broad range of wavelengths. Silicon charge-coupled devices (CCDs), such as EMCCDs, Skipper CCDs, and Multi-Amplifier Sensing CCDs, have demonstrated the ability to detect and measure single photons from ultra-violet to near-infrared wavelengths, making them candidate technologies for this application. In this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic charged particles traversing a silicon detector. In the intense radiation environment of space, energetic cosmic rays produce high-energy tracks and more extended halos of low-energy Cherenkov photons, which are detectable with ultra-low-noise detectors. We present a model of this effect that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low noise silicon detectors in space. We find that the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds that have previously been considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of photoconductive indium antimonide

Indium antimonide (InSb) material was assessed for use as photoconductive infrared detectors under low background conditions. Such detectors must be more rugged, and have lower capacitance, than the common photovoltaic InSb detector. Electronic grade n-type InSb was etched to 50 micrometers thickness, and tin and gold contacts were applied by evaporation. The test devices showed a relatively low ultimate impedance: 7 Mohms at 4.2 K. This was attributed to the presence of impurity levels of very shallow energies, and this material was judged unsuitable for low background detection.

Low, F. J.↗

Solid state photomultiplier for astronomy, phase 2

Epitaxial layers with varying donor concentration profiles were grown on silicon substrate wafers using chemical vapor deposition (CVD) techniques, and solid state photomultiplier (SSPM) devices were fabricated from the wafers. Representative detectors were tested in a low background photon flux, low temperature environment to determine the device characteristics for comparison to NASA goals for astronomical applications. The SSPM temperatures varied between 6 and 11 K with background fluxes in the range from less than 5 x 10 to the 6th power to 10 to the 13th power photons/square cm per second at wavelengths of 3.2 and 20 cm. Measured parameters included quantum efficiency, dark count rate and bias current. Temperature for optimal performance is 10 K, the highest ever obtained for SSPMs. The devices exhibit a combination of the lowest dark current and highest quantum efficiency yet achieved. Experimental data were reduced, analyzed and used to generate recommendations for future studies. The background and present status of the microscopic theory of SSPM operation were reviewed and summarized. Present emphasis is on modeling of the avalanche process which is the basis for SSPM operation. Approaches to the solution of the Boltzmann transport equation are described and the treatment of electron scattering mechanisms is presented. The microscopic single-electron transport theory is ready to be implemented for large-scale computations.

Besser, P. J.↗

A progress report on bolometers operating at 0.1 K using adiabatic demagnetization refrigeration

Bolometers are still the detectors of choice for low background infrared observations at wavelengths longer than 200 microns. In the low background limit, bolometers become more sensitive as their operating temperature decreases, due to fundamental thermodynamic laws. The adiabatic demagnetization technique was evaluated by building a bolometer detection system operating at a wavelength of 1 millimeter for use at a ground based telescope. The system was fit checked at the telescope and is expected to take its first data in November, 1985.

Roellig, T.↗

Cherenkov Photon Background for Low-Noise Detectors in Space

Future space observatories dedicated to the direct imaging and spectroscopy of extra-solar planets require ultra-low-noise detectors sensitive at ultraviolet (UV) to infrared (IR) wavelengths. When observing faint sources, detector noise must be studied and minimized in order to maximize signal-to-noise (SNR). However, due to the intense radiation environment of space and the demonstrated ultra-low-noise achievable by modern detectors, Cherenkov radiation emerges as a relatively unexplored source of low-energy background.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A fixed-target platform for serial femtosecond crystallography in a hydrated environment

For serial femtosecond crystallography at X-ray free-electron lasers, which entails collection of single-pulse diffraction patterns from a constantly refreshed supply of microcrystalline sample, delivery of the sample into the X-ray beam path while maintaining low background remains a technical challenge for some experiments, especially where this methodology is applied to relatively low-ordered samples or those difficult to purify and crystallize in large quantities. This work demonstrates a scheme to encapsulate biological samples using polymer thin films and graphene to maintain sample hydration in vacuum conditions. The encapsulated sample is delivered into the X-ray beam on fixed targets for rapid scanning using the Roadrunner fixed-target system towards a long-term goal of low-background measurements on weakly diffracting samples. As a proof of principle, we used microcrystals of the 24 kDa rapid encystment protein (REP24) to provide a benchmark for polymer/graphene sandwich performance. The REP24 microcrystal unit cell obtained from our sandwiched in-vacuum sample was consistent with previously established unit-cell parameters and with those measured by us without encapsulation in humidified helium, indicating that the platform is robust against evaporative losses. While significant scattering from water was observed because of the sample-deposition method, the polymer/graphene sandwich itself was shown to contribute minimally to background scattering.

36 MATERIALS SCIENCE↗

Toward Trustworthy Detectors Detector Characterization for SuperCDMS SNOLAB Commissioning

SuperCDMS SNOLAB is a next generation direct detection experiment searching for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As commissioning begins, establishing stable, predictable detector response to energy deposits is a prerequisite for future physics analysis. This work studies detector stability and calibration for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium) and det 11 and det 14 (silicon), using Barium-133 calibration data (356 keV gamma ray reference) and low background data (ambient radiation, no external source). The Ba-133 data show no distinct line at the expected energy, and the low background data show a baseline that drifts and oscillates rather than remaining flat, consistently across multiple channels, suggesting a shared, detector wide cause. These observations point to the cryogenic support system as the likely source, since small temperature fluctuations could couple into the temperature sensitive detectors, informing the ongoing commissioning effort.

O'Hanlon, Vika [Skidmore Coll.]↗

Radioactivities of Long Duration Exposure Facility (LDEF) materials: Baggage and bonanzas

Radioactivities in materials onboard the returned Long Duration Exposure Facility (LDEF) satellite were studied by a variety of techniques. Among the most powerful is low-background Ge-semiconductor detector gamma-ray spectrometry, illustrated here by results obtained at the Lawrence Berkeley Laboratory's (LBL) Low Background Facilities. The observed radioactivities are of two origins: those radionuclides produced by nuclear reactions with the radiation field in orbit, and radionuclides present initially as 'contaminants' in materials used for construction of the spacecraft and experimental assemblies. In the first category are experiment-related monitor foils and tomato seeds, and such spacecraft materials as aluminum, stainless steel, and titanium. In the second category are aluminum, beryllium, titanium, vanadium, and some special glasses.

Smith, Alan R.↗

Chirped-Superlattice, Blocked-Intersubband QWIP

An Al(x)Ga(1-x)As/GaAs quantum-well infrared photodetector (QWIP) of the blocked-intersubband-detector (BID) type, now undergoing development, features a chirped (that is, aperiodic) superlattice. The purpose of the chirped superlattice is to increase the quantum efficiency of the device. A somewhat lengthy background discussion is necessary to give meaning to a brief description of the present developmental QWIP. A BID QWIP was described in "MQW Based Block Intersubband Detector for Low-Background Operation" (NPO-21073), NASA Tech Briefs Vol. 25, No. 7 (July 2001), page 46. To recapitulate: The BID design was conceived in response to the deleterious effects of operation of a QWIP at low temperature under low background radiation. These effects can be summarized as a buildup of space charge and an associated high impedance and diminution of responsivity with increasing modulation frequency. The BID design, which reduces these deleterious effects, calls for a heavily doped multiple-quantum-well (MQW) emitter section with barriers that are thinner than in prior MQW devices. The thinning of the barriers results in a large overlap of sublevel wave functions, thereby creating a miniband. Because of sequential resonant quantum-mechanical tunneling of electrons from the negative ohmic contact to and between wells, any space charge is quickly neutralized. At the same time, what would otherwise be a large component of dark current attributable to tunneling current through the whole device is suppressed by placing a relatively thick, undoped, impurity-free AlxGa1 x As blocking barrier layer between the MQW emitter section and the positive ohmic contact. [This layer is similar to the thick, undoped Al(x)Ga(1-x)As layers used in photodetectors of the blocked-impurity-band (BIB) type.] Notwithstanding the aforementioned advantage afforded by the BID design, the responsivity of a BID QWIP is very low because of low collection efficiency, which, in turn, is a result of low electrostatic- potential drop across the superlattice emitter. Because the emitter must be electrically conductive to prevent the buildup of space charge in depleted quantum wells, most of the externally applied bias voltage drop occurs across the blocking-barrier layer. This completes the background discussion. In the developmental QWIP, the periodic superlattice of the prior BID design is to be replaced with the chirped superlattice, which is expected to provide a built-in electric field. As a result, the efficiency of collection of photoexcited charge carriers (and, hence, the net quantum efficiency and thus responsivity) should increase significantly.

Gunapala, Sarath↗

Twelve-crystal prototype of Li 2 MoO 4 scintillating bolometers for CUPID and CROSS experiments

An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, μBq/kg, level of the LMO crystals radioactive contamination by 228 Th and 226 Ra.

47 OTHER INSTRUMENTATION↗

Detector Characterization for SuperCDMS Commissioning

Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB is a next generation direct detection experiment search ing for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As the experiment begins its first commissioning data taking, establishing that the detectors respond to energy deposits in a stable, predictable way is a prerequisite for any future physics analysis. This work presents a study of detector stability for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium), and det 11 and det 14 (silicon), using two data sets taken during early commissioning: dedicated Barium-133 calibration runs, which provide a known gamma ray energy reference at 356 keV, and low background runs, which record whatever background radiation the detectors see with no external source present. The Ba-133 data do not show a distinct, well localized line at the expected energy, and the low background data show a baseline that drifts and oscillates over time rather than remaining flat. This baseline instability appears consistently across multiple channels rather than being confined to one, suggesting a shared, detector wide cause rather than a single faulty channel. Together, these observations point to the detectors’ cryogenic support system as the likely source of the instability, since small temperature fluctuations introduced during normal operation of the cooling system could plausibly couple into the exquisitely temperature sensitive detectors. These results inform the ongoing commissioning effort by narrowing down where instability in the current data is originating from.

O'Hanlon, Viktoria M. [Skidmore Coll.; Fermilab]↗

Detector Characterization for SuperCDMS Commissioning

Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB is a next generation direct detection experiment search ing for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As the experiment begins its first commissioning data taking, establishing that the detectors respond to energy deposits in a stable, predictable way is a prerequisite for any future physics analysis. This work presents a study of detector stability for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium), and det 11 and det 14 (silicon), using two data sets taken during early commissioning: dedicated Barium-133 calibration runs, which provide a known gamma ray energy reference at 356 keV, and low background runs, which record whatever background radiation the detectors see with no external source present. The Ba-133 data do not show a distinct, well localized line at the expected energy, and the low background data show a baseline that drifts and oscillates over time rather than remaining flat. This baseline instability appears consistently across multiple channels rather than being confined to one, suggesting a shared, detector wide cause rather than a single faulty channel. Together, these observations point to the detectors’ cryogenic support system as the likely source of the instability, since small temperature fluctuations introduced during normal operation of the cooling system could plausibly couple into the exquisitely temperature sensitive detectors. These results inform the ongoing commissioning effort by narrowing down where instability in the current data is originating from.

O'Hanlon, Viktoria M. [Skidmore Coll.; Fermilab]↗

Development and evaluation of integrated infrared arrays for astronomical applications

The status of a technology program to evaluate existing infrared detector arrays, and to develop improved ones for low background astronomical applications, is described. For applications such as the Shuttle Infrared Telescope Facility, arrays that cover as much of the 1-1000 micron range as possible are of interest. Low background test results for a 2 x 64 Si:Bi charge-injection-device, and 1 x 20 InSb charge-coupled-device arrays, are included. As a result of the present testing, improved, astronomy-optimized extrinsic silicon arrays in both linear and area formats are planned. Efforts to develop accumulation mode MOSFETs specifically for liquid helium temperatures, and cryogenic amplifier and multiplexer circuits, are discussed.

Mccreight, C. R.↗

Evaluation and mitigation of trace 210Pb contamination on copper surfaces

Clean materials are required to construct and operate many low-background physics experiments. High-purity copper has found broad use because of its physical properties and availability. In this paper, we describe methods to assay and mitigate Pb-210 contamination on copper surfaces, such as from exposure to environmental radon or coming from bulk impurities. We evaluated the efficacy of wet etching on commercial samples and observed that Po-210 contamination from the copper bulk does not readily pass into solution. During the etch, the polonium appears to trap at the copper-etchant boundary, such that it is effectively concentrated at the copper surface. We observed a different behavior for Pb-210; high-sensitivity measurements of the alpha emissivity versus time indicate the lowest level of Pb-210 contamination ever reported for a commercial copper surface: 0 +/- 12 nBq/cm2 (1-sigma). Additionally, we have demonstrated the effectiveness of mitigating trace Pb-210 and Po-210 surface backgrounds using custom, high-purity electroplating techniques. These approaches were evaluated utilizing assays performed with an XIA UltraLo-1800 alpha spectrometer.

radon, copper, copper cleaning, dark matter, Pb-21↗

Crystallization of ApoA1 and ApoE4 Nanolipoprotein Particles and Initial XFEL-Based Structural Studies

Nanolipoprotein particles (NLPs), also called “nanodiscs”, are discoidal particles with a patch of lipid bilayer corralled by apolipoproteins. NLPs have long been of interest due to both their utility as membrane-model systems into which membrane proteins can be inserted and solubilized and their physiological role in lipid and cholesterol transport via high-density lipoprotein (HDL) and low-density lipoprotein (LDL) maturation, which are important for human health. Serial femtosecond crystallography (SFX) at X-ray free electron lasers (XFELs) is a powerful approach for structural biology of membrane proteins, which are traditionally difficult to crystallize as large single crystals capable of producing high-quality diffraction suitable for structure determination. To facilitate understanding of the specific role of two apolipoprotein/lipid complexes, ApoA1 and ApoE4, in lipid binding and HDL/LDL particle maturation dynamics, and to develop new SFX methods involving NLP membrane protein encapsulation, we have prepared and crystallized homogeneous populations of ApoA1 and ApoE4 NLPs. Crystallization of empty NLPs yields semi-ordered objects that appear crystalline and give highly anisotropic and diffuse X-ray diffraction, similar to fiber diffraction. Several unit cell parameters were approximately determined for both NLPs from these measurements. Thus, low-background, sample conservative methods of delivery are critical. Here we implemented a fixed target sample delivery scheme utilizing the Roadrunner fast-scanning system and ultra-thin polymer/graphene support films, providing a low-volume, low-background approach to membrane protein SFX. This study represents initial steps in obtaining structural information for ApoA1 and ApoE4 NLPs and developing this system as a supporting scaffold for future structural studies of membrane proteins crystalized in a native lipid environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Results of low energy background measurements with the Liquid Scintillation Detector (LSD) of the Mont Blanc Laboratory

The 90 tons liquid scintillation detector (LSD) is fully running since October 1984, at a depth of 5,200 hg/sq cm of standard rock underground. The main goal is to search for neutrino bursts from collapsing stars. The experiment is very sensitive to detect low energy particles and has a very good signature to gamma-rays from (n,p) reaction which follows the upsilon e + p yields n + e sup + neutrino capture. The analysis of data is presented and the preliminary results on low energy measurements are discussed.

Aglietta, M.↗