Search NASA⌕ Search

SEARCH · Search NASA

Results for “low refractive index”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Enhanced Fluoride Over-Coated Al Mirrors for FUV Astronomy

Astronomical observations in the Far Ultraviolet (FUV) spectral region are some of the more challenging due to the very distant and faint objects that are typically searched for in cosmic origin studies such as origin of large scale structure, the formation, evolution, and age of galaxies and the origin of stellar and planetary systems. These challenges are driving the need to improve the performance of optical coatings over a wide spectral range that would increase reflectance in mirrors and reduced absorption in dielectric filters used in optical telescope for FUV observations. This paper will present recent advances in reflectance performance for Al+MgF2 mirrors optimized for Lyman-alpha wavelength by performing the deposition of the MgF2 overcoat at elevated substrate temperatures. We will also present optical characterization of little studied rare-earth fluorides such as GdF3 and LuF3 that exhibit low-absorption over a wide wavelength range and could therefore be used as high refractive index alternatives for dielectric coatings at FUV wavelengths.

Reflectance↗

Recent Progress on 2012 SAT for UVOIR Coatings

Astronomical observations in the Far Ultraviolet (FUV) spectral region are some of the more challenging due to the very distant and faint objects that are typically searched for in cosmic origin studies such as origin of large scale structure, the formation, evolution, and age of galaxies and the origin of stellar and planetary systems. These challenges are driving the need to improve the performance of optical coatings over a wide spectral range that would increase reflectance in mirrors and reduced absorption in dielectric filters used in optical telescope for FUV observations. This paper will present recent advances in reflectance performance for Al+MgF2 mirrors optimized for Lyman-alpha wavelength by performing the deposition of the MgF2 overcoat at elevated substrate temperatures. We will also present optical characterization of little studied rare-earth fluorides such as GdF3 and LuF3 that exhibit low-absorption over a wide wavelength range and could therefore be used as high refractive index alternatives fordielectric coatings at FUV wavelengths.

LiF↗

Optical characterization of the oceanic unicellular cyanobacterium Synechococcus grown under a day-night cycle in natural irradiance

The optical properties of the ocenanic cyanobacterium Synechococcus (clone WH8103) were examined in a nutrient-replete laboratory culture grown under a day-night cycle in natural irradiance. Measurements of the spectral absorption and beam attenuation coefficients, the size distribution of cells in suspension, and microscopic analysis of samples were made at intervals of 2-4 hours for 2 days. These measurements were used to calculate the optical properties at the level of a single 'mean' cell representative of the acutal population, specifically, the optical cross sections for spectral absorption bar-(sigma(sub a)), scattering bar-sigma(sub b))(lambda), and attentuation bar-(sigma(sub c))(lambda). In addition, concurrent determinations of chlorophyll a and particulate organic carbon allowed calculation of the Chl a- and C-specific optical coefficients. The refractive index of cells was derived from the observed data using a theory of light absorption and scattering by homogeneous spheres. Low irradiance because of cloudy skies resulted in slow division rates of cells in the culture. The percentage of dividing cells was unusually high (greater than 30%) throughout the experiment. The optical cross sections varied greatly over a day-night cycle, with a minimum near dawn or midmorning and maximum near dusk. During daylight hours, bar-(sigma(sub b)) and bar-(sigma(sub c)) can increase more than twofold and bar-(sigma(sub a) by as much as 45%. The real part of the refractive index n increaed during the day; changes in n had equal or greater effect than the varying size distribution on changes in bar-(sigma(sub c)) and bar-(sigma(sub b)). The contribution of changes in n to the increase of bar-(sigma(sub c))(660) during daylight hours was 65.7% and 45.1% on day 1 and 2, respectively. During the dark period, when bar-(sigma(sub c))(660) decreased by a factor of 2.9, the effect of decreasing n was dominant (86.3%). With the exception of a few hours during the second light period, the imaginary part of the refractive index n' showed little variation over a day-night cycle, and bar-(sigma(sub a)) was largely controlled by variations in cell size. The real part of the refractive index at lambda = 660 nm was correlated with the intracellular C concentration and the imaginary part at lambda = 678 nm with the intracellular Chl a concentration. The C-specfic attenuation coefficient showed significant diel variability, which has implications for the estimation of oceanic primary production from measurements of diel variability in beam attenuation. This study provides strong evidence that diel variability is an important component of the optical characterization of marine phytoplankton.

Stramski, Dariusz↗

Spacelab experiment definition study on phase transition and critical phenomena in fluids: Interim report on experimental justification

Pure fluids and fluid mixtures near critical points are identified and are related to the progress of several disciplines. Consideration is given to thermodynamic properties, transport properties, and the complex nonlinear phenomena which occur when fluids undergo phase transitions in the critical region. The distinction is made between practical limits which may be extended by advances in technology and intrinsic ones which arise from the modification of fluid properties by the earth's gravitational field. The kinds of experiments near critical points which could best exploit the low gravity environment of an orbiting laboratory are identified. These include studies of the index of refraction, constant volume specific heat, and phase separation.

Moldover, M. R.↗

Air-To-Air Background Oriented Schlieren Technique

An air-to-air background-oriented Schlieren system and method for measuring and rendering visible density changes in air that cause a refractive index change by an airborne vehicle. A sensor aircraft equipped with a high-speed visible spectrum camera travels at low airspeed on a predetermined route and on a level altitude over a background having consistent contrast and sunlight reflectivity. The target aircraft, traveling on the same predetermined route but at an altitude between the sensor aircraft and the ground (background) passes beneath the sensor aircraft. The camera on the sensor aircraft captures a series of images including a reference image immediately before the target aircraft enters the image frame followed by several data images as the target aircraft passes through the image frame. The data images are processed to calculate density gradients around the target aircraft. These density gradients include shockwaves, vortices, engine exhaust, and wakes. Air density gradients cause a refractive index change in the fluid and a slight distortion in the background pattern of the data image. Image processing that compares the data image to the reference image yields the difference caused by the density gradient.

Heineck, James Thomas↗

Optical properties of solid CO2 - Application to Mars

Using a special low-temperature cell, thick layers of solid CO2 are grown on an infrared-transparent window. The transmission spectra of solid CO2 is measured from 4000 to 360 kaysers (2.5-27.8 microns). The complex index of refraction is derived for samples of different thicknesses. Scattering in the samples is the major source of error. Away from the major absorption bands the imaginary index is very low. The absorption coefficient is of the order of 1 kayser. The emissivity in the Viking IRTM 20-micron band of a solid surface of CO2 is estimated at 0.72 + 0.17 or -0.10. Snowlike deposits have similar or lower emissivity. The results of this paper relieve the need for exceptional meteorology to explain Martian brightness temperatures below the CO2 frost point.

Ditteon, R.↗

Photorefractive page composer

Optical information-storage device is small, easy to operate, and has low optical losses. Device utilizes optical system in which storage medium, a plate of photosensitive material, changes its refractive index upon exposure to light. Major design feature is that page-composer plate does not require complete erasure between scans.

Verber, C. M.↗

A program to study antiprotons in the cosmic rays: Arizona collaboration

The Cherenkov detector designed and built for the LEAP (Low Energy AntiProton) experiment utilized a novel design to achieve appreciable sensitive area (02. sq m) with a refractive index of 1.25 in a magnetic fringe field region (500-1000 Gauss). The weight was held to only 64 kg by using 16 unshielded Hamamatsu R2490-01 photomultiplier tubes, each aligned with its local magnetic field. A filling and reservoir system for the highly volatile FC-72 liquid Cherenkov radiator also presented many design challenges. Relativistic particles yielded about 72 photoelectrons, total.

Bowen, Theodore↗

From Low-Cost Sensors to High-Quality Data: A Review of Challenges and Summary of Best Practices for Effectively Using Low-Cost Particulate Matter Mass Sensors

Low-cost sensors for particulate matter mass (PM) enable spatially dense, high temporal resolution measurements of air quality that traditional reference monitoring cannot. Low-cost PM sensors are especially beneficial in low and middle-income countries where few, if any, reference grade measurements exist and in areas where the concentration fields of air pollutants have significant spatial gradients. Unfortunately, low-cost PM sensors also come with a number of challenges that must be addressed if their data products are to be used for anything more than a qualitative characterization of air quality. The various PM sensors used in low-cost monitors are all subject to biases and calibration dependencies, corrections for which range from relatively straightforward(e.g. meteorology, age of sensor) to complex (e.g. aerosol source, composition, refractive index). The methods for correcting and calibrating these biases and dependencies that have been used in the literature likewise range from simple linear and quadratic models to complex machine learning algorithms. Here we review the needs and challenges when trying to get high-quality data from low-cost sensors. We also present a set of best practices to follow to obtain high-quality data from these low-cost sensors.

low-cost sensors↗

Low elevation angle KU-band satellite measurements at Austin, Texas

At low elevation angles, the propagation of satellite signals is affected by precipitation as well as by inhomogeneties of the refractive index. Whereas precipitation causes fades for relatively small percentages of time, the refractive index variability causes scintillations which can be observed for most of the time. An experiment is now under way in Austin, Texas, in which the right hand circularly polarized 12 GHz beacon of INTELSAT-V/F10 is observed at a 5.8 deg elevation angle, along with the radiometric sky temperature, rainfall rate, humidity, pressure, temperature, and wind speed and direction. The objective of these measurements is to accumulate a database over a period of 2 years and to analyze the probabilities and dynamical behavior of the signal variations in relation to the meteorological parameters. The hardware and software used for the data acquisition and analysis is described and the results from the first year of measurements are presented.

Vogel, Wolfhard J.↗

Room-temperature continuous operation of InAsSb quantum-dot lasers near 2 mu m based on (100) InP substrate

Single-stack InAsSb self-assembled quantum-dot lasers based on (001) InP substrate have been grown by metalorganic vapor-phase epitaxy. The narrow ridge waveguide lasers lased at wavelengths near 2 mu m up to 25 degrees C in continuous-wave operation. At room temperature, a differential quantum efficiency of 13 percent is obtained and the maximum output optical power reaches 3 mW per facet with a threshold current density of 730 A/cm(sup 2). With increasing temperature the emission wavelength is extremely temperature stable, and a very low wavelength temperature sensitivity of 0.05 nm/degrees C is measured, which is even lower than that caused by the refractive index change.

Semiconductor lasers quantum dots↗

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

Engineering cellular metabolism for targeted biosynthesis can require extensive design-build-test-learn (DBTL) cycles as the engineer works around the cell's survival requirements. Alternatively, carrying out DBTL cycles in cell-free environments can accelerate this process and alleviate concerns with host compatibility. A promising approach to cell-free metabolic engineering (CFME) leverages metabolically active crude cell extracts as platforms for biomanufacturing and for rapidly discovering and prototyping modified proteins and pathways. Realizing these capabilities and optimizing CFME performance requires methods to characterize the metabolome of lysate-based cell-free platforms. That is, analytical tools are necessary for monitoring improvements in targeted metabolite conversions and in elucidating alterations to metabolite flux when manipulating lysate metabolism. In this work, metabolite analyses using high-performance liquid chromatography (HPLC) coupled with either optical or mass spectrometric detection were applied to characterize metabolite production and flux in E. coli S30 lysates. Specifically, this report describes the preparation of samples from CFME lysates for HPLC analyses using refractive index detection (RID) to quantify the generation of central metabolic intermediates and by-products in the conversion of low-cost substrates (i.e., glucose) to various high-value products. The analysis of metabolite conversion in CFME reactions fed with 13 C-labeled glucose through reversed-phase liquid chromatography coupled to tandem mass spectrometry (MS/MS), a powerful tool for characterizing specific metabolite yields and lysate metabolic flux from starting materials, is also presented. Altogether, applying these analytical methods to CFME lysate metabolism enables the advancement of these systems as alternative platforms for executing faster or novel metabolic engineering tasks.

59 BASIC BIOLOGICAL SCIENCES↗

Low Index Contrast Valley Hall Topological Photonics for Robust Transport in the Visible Spectrum

We report topological photonics is an emerging platform to study light-matter interactions with promising features such as robust edge state transmission that could be advantageous for quantum information applications. However, applying common topological photonic designs for visible wavelength light-matter interactions is challenging because materials compatible with the visible spectrum have lower refractive index contrasts. We design and demonstrate a novel valley Hall topological photonic crystal that can support a complete topological band gap in the visible spectrum. We also show an overetch procedure can be used to reduce the leakage loss common for low index contrast materials. To demonstrate these advantages, we fabricate topological photonic devices following these design principles and show that edge states at energies in the complete band gap have robust transmission around sharp corners. The compatibility of this photonic structure with straightforward fabrication methods will facilitate the study of interactions between topologically nontrivial photons and nanomaterials active in the visible spectrum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Biomass-Based Fuels and Fuel Blends for Low-Emissions, Advanced Compression Ignition Engines (Final Report)

The goal of the Co-Optima program was to accelerate deployment of co-optimized fuels and engines that will reduce fuel consumption, and criterion pollutants and greenhouse gas (GHG) emissions for both spark and compression-ignited engines. In this project, combustion measurements from a constant pressure flow rig (CPFR) with optical access were used to assess fundamental combustion behavior of number of different candidate fuels and fuel blends. This chamber and its peripheral systems allowed stable control of ambient air pressure and temperature and fuel injection pressure and timing for hundreds of repeat injections allowing statistical interpretation of the results. The optical diagnostics enabled capturing of liquid length, vapor length, ignition timing, lift-off length as well as localized (temporal and spatially resolved) mixture refractive index, flame structure, and soot mass. The operating conditions allowed the study of combustion conditions promoting lean lifted flame combustion (LLFC), a mixing-controlled low-temperature combustion (LTC) strategy to reduce soot production in Advanced Compression Ignition (ACI) engines.

09 BIOMASS FUELS↗

A search for the prewetting line

This paper describes efforts to locate the prewetting line in a binary liquid system (isopropanol-perfluoromethylcyclohexane) at the vapor-liquid interface. Tight upper bounds were placed on the temperature separation (0.2 K) between the prewetting line and the line of bulk liquid phase separation. The prewetting line in systems at equilibrium was not detected. Experimental signatures indicative of the prewetting line occurred only in nonequilibrium situations. Several theories predict that the adsorption of one of the components (the fluorocarbon, in this case) at the liquid-vapor interface should increase abruptly, at a temperature sightly above the temperature at which the mixture separates into two liquid phases. A regular solution calculation indicates that this prewetting line should have been easily detectable with the instruments used in this experiment. Significant features of the experiment are: (1) low-gradient thermostatting, (2) in situ stirring, (3) precision ellipsometry from the vapor-liquid interface, (4) high resolution differential index of refraction measurements using a novel cell design, and (5) computer control.

Schmidt, J. W.↗

A design study of a photorefractive page composer

A laboratory demonstration and preliminary system analysis of a page composer designed to have the dual advantages of low optical loss and small size, were reported. The current page composer is optically addressed and functions by virtue of optically induced refractive index changes in the active material. Laboratory demonstrations of the device were successfully performed using 10 x 10 bit and 128 x 128 bit data arrays. It was established that the only significant obstacle to the construction of a brass-board model working at megabit data rates is the lack of sensitivity of the photorefractive materials which were considered during the course of this study. Possible materials for future consideration are the photoplastics. While they have more than the required sensitivity, their stability and suitability for double exposure holography was not investigated. If a sufficiently sensitive material is found, then the photorefractive page composer could be built to perform in a highly efficient fashion which would result in a overall reduction of the size of the memory system and an easing of the requirements upon the sensitivity of the holographic recording material.

Source record↗

The rate of occurrence of dayside Pc 3,4 pulsations - The L-value dependence of the IMF cone angle effect

When the angle of the IMF to the earth sun line is 15 deg or less, the occurrence rate of dayside Pc 3,4 pulsations in 7-8 times the average at L values of 2.4-2.8, and 2.2-3.5 times the average at L of 4-4.3. These waves disappear when the IMF is nearly at right angles to the sun-earth line. Such observations are consistent with a source originating in the waves upstream of the subsolar bow shock, which are transported by convection to the magnetopause. There, they couple to oscillations of magnetospheric field lines. Because the magnetospheric plasma's index of refraction decreases with radial distance except at the plasmapause, inwardly propagating waves should be refracted away from the radial direction. To reach low L values, the waves should therefore couple near the stagnation point and propagate nearly radially inwards. The streamline geometry and its connection to the foreshock region is illustrated for various IMF orientations, using a simple approximation to the magnetosheath flow field.

Russell, C. T.↗