Search NASA⌕ Search

SEARCH · Search NASA

Results for “lower plenum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Spectral Analysis of LDV Measurements inside of the TAMU Air-Cooled Reactor Cavity Cooling System - 18688

Spectral analysis was applied to the LDV measurements inside of the TAMU air-cooled RCCS facility at two different locations to both evaluate the feasibility of spectral methods for this experiment and gain a first insight into the flow behavior using a Fourier representation. Application of the wavelet transform showed that there are patterns in the flow signified by repeating frequencies and flow structures. Although the sampling rate of 7.92 Hz at the data point centered at the bottom center of riser 4 was lower than the higher frequency sampling rate of 57.92 Hz at the top data point of the upper plenum, the wavelet transforms of the higher frequency data point showed that the dominant frequencies were bounded within 4 Hz. Application of wavelet analysis is limited by the size of the interrogation window but may be modified according to the frequency range of interest by adjusting the size of the time width for the undilated Morlet mother wavelet. Spectral analysis can be applied to future experiments to understand uncharacterized flow behavior such as flow reversal inside of the upper plenum and for benchmarking future CFD simulations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Examination of entrainment, combustibility, and heat transfer due to cell venting inside simplified battery energy storage enclosures

Battery energy storage systems (ESS) assembled of modules containing lithium-ion batteries can pose fire and explosion hazards during thermal runaway because vented gases may accumulate, combust, or escape enclosures. Here, we propose a prototypical configuration composed of the main components of an ESS rack, where modules are represented as rectangles within an enclosure and vent gas is injected steadily through the top of a module. This idealized geometry allows for exploration of how rack-level characteristics can influence smaller single-cell or module-level scales. Through this geometry, we conduct numerical simulations to understand how variations in the vent velocity, temperature, and vertical location affect entrainment rates, fraction of uncombusted fuel, rich-gas coverage, and heat flux to other modules. At lower vent velocities and vertical positions, buoyancy drives enough entrainment and mixing to react with most of the vent gases on the converging plenum. As jet momentum increases and/or buoyancy decreases via higher vent position in the rack, vent gases can propagate into and burn in the divergence plenum. Heat flux to the impinged module scales strongly with vent momentum and temperature, while heat transfer to upper modules peaks when flames in the diverging plenum reach the surface and declines when combustion is suppressed.

Computational fluid dynamics↗

3D CFD Model Validation Using Benchmark Data of 1/16th Scaled VHTR Upper Plenum and Development of Wall Heat-Transfer Correlation For Laminar Flow

With support from the U.S. Department of Energy-Office of Nuclear Energy’s (DOE-NE’s) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, an effort has been pursued to support high-temperature gas-cooled reactor (HTGR) technology development and its modeling and simulation needs. There is a particular need for advanced modeling and simulation tools to predict thermal-fluid behavior in the nuclear reactor primary system, especially in the core and the lower and upper plena, during safety-related transients. In this report, two main such activities are presented relevant to the HTGRs: (1) three-dimensional (3D) computational fluid dynamics (CFD) validation using benchmark data from the upper plenum of Texas A&M University’s 1/16th scaled very-high-temperature gas-cooled reactor (VHTR), and (2) development of wall heat-transfer correlation for laminar flow in a wall-heated pipe. The CFD tool validation exercises can be helpful to choose the models and CFD tools to simulate and design specific components of the HTRGs such as upper plenum where jet mixing is a complex phenomenon. In a loss of forced circulation event, the laminar flow can be observed during the development of natural circulation flow. This work includes the development and validation of heat transfer correlations for laminar flow using the Nek5000 CFD code due to limited available experimental data for laminar flow conditions to guide low-order models (1D). In this report, the flow characteristics of a single isothermal jet discharging into the upper plenum was investigated using the Nek5000 Large-Eddy Simulation (LES) CFD tool. Several numerical simulations were performed for various jet-discharged Reynolds numbers ranging from 3,413 to 12,819. A grid-independent study was performed. The numerical results of mean velocity, root-mean-square fluctuating velocity, and Reynolds stress were compared against the benchmark data. Good agreement was obtained between simulated and measured data for axial mean velocities, except near the upper plenum hemisphere. The maximum predicted errors for axial mean velocities at various normalized coolant channel diameter heights of 1, 5, and 10 are 1.56%, 1.88%, and 3.82%, respectively. In addition, the predicted root-mean-square fluctuating velocity and Reynolds stress are qualitatively in agreement with the experimental data. The Nek5000 code was used to develop wall-heat transfer correlation for laminar flow in a cylindrical tube. Several simulations were performed for various Reynolds flow and wall-heat fluxes. A new heat transfer correlation was developed using data from Nek5000 simulation results and regression functions in Matlab. The developed heat transfer correlation is valid for various Reynolds flows from 200 to 2000. The predicted R² value for model fit was 0.875, which ensures that 87.5% of the model data lies on the Nek5000 data. Moreover, a machine learning (ML) tool was used to train and test the Nek5000 data. A good fit of the ML-based model was observed with the test data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

THREE-DIMENSIONAL THERMAL MODELING ANALYSIS OF CST MEDIA FOR THE SMALL ION EXCHANGE PROJECT

The Small Column Ion Exchange (SCIX) project is designed to accelerate closure of High Level Waste (HLW) tanks at the Savannah River Site (SRS). The SRS tanks store HLW in three forms: sludge, saltcake, and supernate. An in-tank ion exchange process is being designed to treat supernate and dissolved saltcake waste. Through this process, radioactive cesium from the salt solution is adsorbed into Crystalline Silicotitanate (CST) ion exchange media packed within a flow-through column. A packed column loaded with radioactive cesium generates significant heat from radiolytic decay. The waste supernate solution within the ion exchange bed will boil around 120 C. Solution superheating above the boiling point within the column could lead to violent hazardous energy releases. System heating from loaded CST is also of concern in other process modules, such as the waste tank. Due to tank structural integrity concerns, the wall temperature limit for the SRS waste tanks is 100 C. The transfer of cesium-loaded CST to the tank could result in localized hot spots on the tank floor and walls which may exceed this limit. As a result, thermal modeling calculations have been conducted to predict the maximum temperatures achievable both in the column and in the waste tank. As specified in the associated Technical Task Plan, one objective of the present work was to compute temperature distributions within the ion exchange column module under accident scenarios including loss of salt solution flow through the bed and loss of coolant system flow. The column modeling domain and the scope of the calculations in this case were broadened relative to previous two-dimensional calculations to include vertical temperature distributions within the packed bed of ion exchange media as well as the upper column plenum region containing only fluid. The baseline design conditions and in-column modeling domain for the ion-exchange column module are shown in Figure 1. These evaluations assumed the maximum bounding cesium loading considered possible based on current knowledge regarding CST media and the anticipated feed compositions. Since this cesium loading was considerably higher than the nominal loading conditions in SRS waste, cases with lower loading were also evaluated. Modeling parameters were the same as those used previously unless otherwise indicated. The current model does not capture multi-phase cooling mechanisms operative when solution boiling occurs. This feature is conservative in the sense that it does not account for the large cooling effects associated with phase transfer. However, the potential transfer of heat to the plenum region associated with vertical bubble ascension through the column during boiling is also neglected. Thermal modeling calculations were also performed for the entire waste storage tank for the case where loaded and ground CST was transferred to the tank. The modeling domain used for the in-tank calculations is provided in Figure 2. The in-tank domain is based on SRS Tank 41, which is a Type-IIIA tank. Temperature distributions were evaluated for cylindrical, ground CST mounds located on the tank floor. Media grinding is required prior to vitrification processing of the CST in the SRS Defense Waste Processing Facility (DWPF). The location of the heat source region on the tank floor due to the accumulation of CST material was assumed to be just under the grinder. The shape of the CST mound was assumed to be cylindrical. This shape is believed to be most representative of the actual mound shape formed in the tank, given that submersible mixing pumps will be available for media dispersion. Alternative configurations involving other geometrical shapes for the CST mound were evaluated in the previous work. Sensitivity analysis for the in-tank region was performed for different amounts of CST media. As was the case for the in-column model, the in-tank model does not include multi-phase cooling mechanisms operative when solution boiling occurs. The in-column and the in-tank evaluations incorporated recently updated maximum cesium loading levels calculated using the current SCIX feed compositions, which resulted in significantly higher cesium loading than previously calculated. The calculations were conducted to ensure conservative predictions for the maximum temperatures achievable using the current baseline design. The degree of conservatism was reduced for in-column calculations relative to the previous work by using a three-dimensional modeling approach and selecting parameters which were nearer to expected conditions. The degree of conservatism for the in-tank calculations was also reduced by lowering the soil penetration depth below the tank from 150 to 20 feet. The primary goals of the extended thermal modeling effort were to determine whether fluid boiling or superheating are possible within the column module and to determine the maximum floor temperatures within the tank loaded with spent CST.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

X-ray and gamma-ray tomographic imaging of fuel relocation inside sodium fast reactor test assemblies during severe accidents

The present work reports on x-ray and gamma-ray high-spatial resolution computerized tomography measurements of the Pin Bundle Metallic Fuel Relocation (PBR) assemblies tested in the Metallic Uranium Safety Experiment (MUSE) facility at Argonne National Lab (ANL). The aim of the study was to characterize fuel relocation structures that develop during severe core accidents pertaining to SFR assemblies; these include but are not limited to advanced core disruption recreated in the PBR-1 assembly, and cladding breach recreated in the PBR-2 assembly. We report the x-ray tomography measurements were able to resolve small quantities of relocation fuel; with increased presence of relocation fuel, the x-ray 1measurements spatially mapped the material but could not resolve the inner regions of these. The gamma-tomography measurements showed improved results, resolving the relocation structures in great detail. The upper plenum of the PBR-1 assembly where the molten uranium was initially inserted presented high structural damage, reflected by the partial and complete disintegration of the central rods. Relocation fuel filled the subchannels, adhering to surviving cladding walls and the assembly casing. In the lower portion of the measured section, the tomogram degrades due to photon starvation effects hinting at the increased amount of relocation fuel potentially plugging the assembly; flow blockage in this section was difficult to determine due to the tomogram’s degradation from photon starvation. Small fragments were observed further down the assembly, dislodged from the initial insertion of the molten material. This section was used as an unperturbed assembly reference, with a calculated blockage of less than 1% from the present fragments. The PBR-2 assembly was characterized by columnar relocation structures propagating through the subchannels. Three of the relocation structures were captured in the measured section, with evidence of cross migration on to adjacent subchannels. The measured section in this assembly captures the leading edge of two structures. The calculated flow blockage was 16% in the planes where the three relocation structures are present, but this quickly decreases to approximately 5% past the leading edge of two of the structures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Transient behavior of a supersonic three-dimensional micronozzle with an intersecting capillary

An analysis of the interaction between a pulsed, supersonic microjet and an intersecting gas-filled capillary is presented, which enables a direct measurement of the pressure evolution inside the nozzle of the microjet. Plasma-emission spectroscopy was used to resolve, on a sub-microsecond timescale, the build-up and decay of pressure in the nozzle, which are shown to be correlated to the volume of the plenum supplying the nozzle and to the nozzle-throat size, respectively. The microjet, which was integrated with a capillary-discharge waveguide in a sapphire structure, was used to create a small, tunable region of high density gas within a centimeter-scale plateau of lower-density for use in a laser-plasma accelerator. The resultant longitudinally structured gas-density profile has been used to provide control of electron trapping and acceleration, but its evolution has not previously been directly quantified. Overall, the results presented here pave the way for improved control of laser-plasma accelerators and are also relevant to applications such as miniature satellites and lab-on-a-chip where precise knowledge of microjet pressure evolution is critical.

47 OTHER INSTRUMENTATION↗

Implementing Fuel Cladding Bonding and Assessing its Impact on Axial Gas Communication

Fuel rods irradiated in light-water reactors to burnup values above 45 MWd/kgU are subject to the formation of a chemical and mechanical bond between the fuel and cladding upon gap closure. The formation of the bond subsequently inhibits the ability of fission gases released from the fuel to flow freely to the plenum of the rod. The flowing of gases within fuel rods is referred to as axial gas communication. During transients, such as loss of coolant accidents, the bond may influence cladding deformation prior to breaking. Upon bond breakage, gases are able to more freely communicate to the lower pressure regions of the rod. The impact of bonding on gas communication and the ballooning behavior of the cladding during a loss of coolant accident is of interest to the nuclear industry in support of burnup extension for the existing light-water reactor fleet. In this report, a model to capture the effects of fuel cladding bonding in the BISON fuel performance code is presented. The theory of the model along with implementation testing is provided. A summary of a previously developed axial gas communication is given to set the stage for how the two models may be coupled together. A full-length pressurized-water reactor fuel rod demonstration is highlighted to evaluate the impact of including bonding on axial gas communication calculations using a preliminary coupling methodology. An overview of the next steps regarding the modeling of bonding, axial gas communication, and a more tightly coupled framework is also provided.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sodium Pumping via Condensation within a Non-Wetting Porous Structure

The sodium thermal electrochemical converter (Na-TEC) is a heat engine that generates electricity via the isothermal expansion of sodium ions through a beta”-alumina solid-electrolyte. The transfer of liquid sodium from a low-pressure condenser to a high-pressure evaporator is necessary to complete the thermodynamic cycle for this conversion process. A unique sodium capillary pump for the Na-TEC is proposed, whereby low-pressure sodium vapor is condensed within a non-wetting (i.e. contact angle > 90o) stainless steel porous structure. Due to the curvature of the non-wetting liquid-vapor interface, the liquid adjacent to the interface is at a higher pressure than the vapor. This is in contrast to traditional wicks, where the liquid adjacent to the interface has a lower pressure. Thus, the curvature created at this non-wetting condensation interface supplies a directed force upon the liquid sodium that effectively “pushes” it towards a high pressure region, whereas a traditional capillary wick “pulls” the liquid. Porous structures made of stainless steel 316 are commercially available, and this material is non-wetting to sodium at the relevant temperature range of the Na-TEC condenser (500K – 673K). An experimental set-up is used to measure several interfacial and transport properties of the condensed sodium within this porous structure. These properties include the temperature dependent Laplace pressure generated at the phase change interface and the permeability of the porous structure. Liquid sodium is in contact with the porous structure and is progressively pressurized with argon gas until the sodium “breaks through” and the liquid begins to flow. This break-through pressure is determined when electrical contact is established between the flowing liquid metal and a set of electrodes cemented along the flow path. The velocity of the flowing sodium can also be measured with these electrodes, and the permeability is then determined by fitting velocity data to the classical Darcy law. These interfacial properties are then applied to a conjugate heat transfer model, which treats the coupled momentum and thermal transport processes within the non-wetting porous structure as sodium vapor is condensed. Due to the low mass flowrates in the Na-TEC (< 0.1 mg/s), higher order friction terms are neglected and the classical Darcy’s law is used for non-isothermal, compressible sodium vapor flow. At lower temperatures, the sodium vapor density becomes sufficiently small and there is a transition from classic Poiseuille flow (Kn < 0.1) to Knudsen flow (Kn > 10). Furthermore, transport due to binary diffusion is considered for situations where there is a substantial presence of non-condensable argon inside the sodium vapor plenum. Initial modeling results showing expected mass flowrates, temperature profiles, and liquid-vapor interface locations are presented for various physical conditions. Finally, the main design features of an experimental set-up used to demonstrate this capillary pumping is described in detail, including the method used to measure the low sodium mass flowrates. Initial experimental results demonstrating sodium pumping for a range of temperatures (800K – 1100K) will be presented and compared against the model predictions. A pump curve used to gauge the performance of this pumping mechanism is also created.

14 SOLAR ENERGY↗

Sodium Pumping via Condensation within a Non-Wetting Porous Structure

The transfer of liquid sodium from a low-pressure condenser to a high-pressure evaporator is required to complete the thermodynamic cycle of a sodium thermal electrochemical converter (Na-TEC). A unique capillary pump is explored in this work, whereby low-pressure sodium vapor is condensed within a non-wetting (i.e. contact angle > pi/2) stainless steel porous structure. Due to the curvature of the non-wetting liquid-vapor interface, the liquid adjacent to the interface is at a higher pressure than the vapor. This is in contrast to traditional wicks, where the liquid adjacent to the interface has a lower pressure. Conjugate heat transfer techniques are used to model the coupled momentum and thermal transport processes within this non-wetting porous structure. Due to the low mass flowrates in the Na-TEC (< 0.1 mg/s), higher order friction terms are neglected and the classical Darcy’s law is used for the non-isothermal, compressible vapor flow. At lower temperatures, the sodium vapor density becomes sufficiently small and there is a transition from classic Poiseuille flow (Kn < 0.1) to Knudsen flow (Kn > 10). Furthermore, transport due to binary diffusion is also considered for situations where there is a substantial presence of non-condensable argon in the sodium vapor plenum. Initial modeling results showing expected mass flowrates, temperature profiles, and liquid-vapor interface locations are presented for various physical conditions. The main design features of an experimental set-up used to demonstrate this capillary pumping is also described in detail, including the method used to measure the low sodium mass flowrates. Initial experimental results demonstrating sodium pumping for a range of temperatures (800K – 1100K) will be presented and compared against the model predictions. Finally, several of the challenges with this experiment will be discussed, and specific strategies used to address these are presented.

14 SOLAR ENERGY↗

Stasis PCM Test Results

A phase change material product distributed by Stasis Group, designed to reduce the cooling energy requirements of multi-story commercial buildings, was tested in a side-by-side comparison at FLEXLAB® (LBNL, 2018), a calibrated test facility for low energy building technology solutions. The product was installed according to Stasis recommendations in the ceiling plenum of a 600 ft 2 cell representative of an office space, while an identical cell was operated in the same conditions, except for the night-time pre-cooling sequence and without the product, to gather baseline data. The cells were operated to replicate summer conditions of a candidate office building for retrofit. For the tests conducted at FLEXLAB, two Phase Change Material (PCM) compositions were tested, with the second product having an upgraded composition for thermal performance and upgraded packaging that was used to meet with fire safety requirements for a plenum application. Two rounds of tests were performed, which were designed to collect data for both core (designated as Round 1) and perimeter (Round 2) office space conditions. Following the analysis of the data collected during Round 1, the experimental design was modified to better represent the thermal conditions of a typical office space in relation to the PCM performance. A new product was also brought in for testing in Round 2, which had an improved operational temperature range and packaging properties. In Round 1, multiple tests were conducted to evaluate the performance of the product under different conditions of internal loads, temperature setpoints, pre-cooling strategies and temperature control strategies. In Round 2, the internal conditions were kept constant, while the test conditions only differ in the amount of PCM installed in the test cell plenum and the length of the nighttime pre-cooling sequence. The performance benefits of PCM are generally two-fold: the material may reduce peak cooling energy use during daytime hours (a peak demand energy use benefit) and may allow for energy savings with pre-cooling at night through night flush HVAC controls when night time outside air temperatures are lower, and fan energy use for cooling is more efficient than the use of daytime compressor-based cooling. The focus of this research project was mainly on quantifying the energy savings potential of the latter case although some effects on peak reduction were noted. Between the cell with PCM and nighttime precooling and the reference cell without PCM or precooling, a reduction in cooling load during occupied hours was noted between 7.6 kWh (or 22% of occupied hours cooling load) and 12.5 kWh (or 33% of occupied pg. 7 hours cooling load). Future work can further evaluate the peak cooling load reduction benefits of this product in more detail. This report highlights the results of Round 2, which reflect the performance of the modified PCM product when operated in suitable conditions. The results of Round 1, along with an analysis of the experimental data to identify the factors that prevented the product from performing as desired are presented in Appendix B.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Counter cross-flow evaporator geometries for supercritical organic Rankine cycles

With recent advancements in advanced manufacturing techniques, it is now possible to fabricate complex geometries that take advantage of well known principles of heat transfer. Therefore, unconventional configurations to enhance effectiveness beyond conventional designs can now be considered for practical application. Thermal performance and overall cost of a new design of heat exchangers in counter cross-flow configurations are studied using a simplified but accurate computational method. The new heat exchanger design was introduced and studied previously for a cross-flow configuration by Sabau et al. (2016, 2018). This new design concept uses multi-scale configurations with successive plenums for the working fluid. At the smallest scale the tubes are sized to be equal to the hydraulic entrance length of the inside fluid, in accord with constructal design. With this being said, results indicate that compared to the earlier cross-flow configuration, the counter cross-flow arrangement improves the thermal performance of the heat exchanger by as much as 17% and lowers the total cost by as much as 14%.

42 ENGINEERING↗

Studying the effect of the upper internal structure design on thermal stratification in sodium fast reactors

Thermal stratification and mixing in large reactor pools can pose significant issues with regard to operation and safety of nuclear plants. While significant work has been done in this area on light water reactors it is more critical for sodium reactors and there is far less data with regard to low Prandtl number fluids. Here this paper focuses on the effect of the upper internal structure on the formation of thermal stratification in a scaled sodium fast reactor upper plenum. Six different upper internal structure configurations were tested to observe the effect on thermal stratification. The degree of stratification was quantified using the stratification number. Each configuration was tested from low to high flow rates at a temperature difference of 50 and 100 °C. Over this broad array of testing, it was observed that higher flow rates, more porosity in the upper internal structure design, and a smaller temperature difference yielded a lower degree of stratification. This information can be used to aid in the design of the upper internal structure in a sodium fast reactor. Furthermore, this high resolved temperature data can be used to verify models under prototypic low Prandtl numbers.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Visual Inspection of Defense Waste Processing Facility Melter 2 Interior after End of Service

Defense Waste Processing Facility (DWPF) Melter 2 reached its end of service life after nearly14 years. A visual inspection of the interior of the melter was performed using a remotely operated camera to provide insight into melter performance and potential failure mechanisms. The condition of the interior of the melter was generally good considering its relatively long service life. The plenum refractory appeared to be in good condition. Spalling and wear of the glass contact refractory was evident at the melt line. There appeared to be some degree of degradation and deposition of material at the dome heater penetrations. Deformation, or sagging of the dome heaters was visible. Only the top surfaces of the upper electrodes were visible due to the full inventory of glass remaining after melter shutdown. The electrodes exhibited small cracks as well as minor deformation (creep or slumping). The lower electrode failure mechanism could not be determined since it was not visible.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

25-Pin metallic fuel performance benchmark case based on the EBR-II X430 experiments series

A metallic fuel benchmark case was developed for the fuel performance code BISON based on 25 uranium-zirconium and uranium-plutonium-zirconium pins of the Experimental Breeder Reactor II X430 experiment series. Results of the benchmarks were compared with measurements and calculations made at the time of the experiment as well as subsequent measurements reported in 2019. The comparisons were used to quantify the accuracy of the BISON predictions and to identify patterns in the BISON differences.BISON predicted burnup, plenum pressure, and fission gas release fractions accurately. BISON temperature predictions were somewhat cooler than the temperatures determined at the time of the experiment but appeared to be reasonably accurate considering uncertainties in the legacy temperature calculations, uncertainties in the legacy linear heat rate calculations, and the high sensitivities of the BISON-predicted temperatures to BISON inputs. Fuel axial elongation predictions had errors correlated to fuel composition; BISON tended to underpredict the elongation of binary fuels and overpredict the elongation of ternary fuels. BISON cladding radial dilation predictions were also significantly lower than legacy PIE measurements.Recommendations were made to improve the BISON fuel gaseous swelling model to account for fuel composition, to add additional capabilities to the coolant channel temperature model to ease benchmark development, and to continue developing benchmark cases based on a wide range of experiments in several reactors. Once a wide array of benchmarks is developed, an attempt can be made to enhance or calibrate BISON models to improve the cladding dilation predictions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Metal fuel relocation experiments with pressure injection

A pool-type sodium-cooled fast reactor (SFR) using metal fuels has a number of inherent safety features that can support benign consequences for design basis accidents (DBAs). Even in postulated severe accident conditions, the core is designed to remain under sub-critical condition in a passive coolable geometry. In case of the postulated severe accidents in SFRs, fuel relocation in the core region along the coolant channel is an important negative reactivity feedback factor that lowers the reactor power level and consequently eliminates the possibility of recriticality. Therefore, understanding the relocation behavior of fuels and the coolability of the relocated fuels in the postulated severe accident is one of the most important factors in the safety assessment of SFRs. In the present study, the relocation behavior of the metal fuel in a pin bundle geometry was investigated by injecting the metal fuels into the coolant channels with pressure. The first metal fuel relocation with pressure injection (RPI-1) experiment showed that many of the metal fuels levitated to upper plenum. In case of RPI-2 experiment, the Real Time X-ray Video System (RTXVS) was constructed and used to obtain a real time X-ray video of the experiment. This real time X-ray video clearly showed the relocation behavior of the pressure injected metallic uranium in the sodium coolant channel. Through this video, it was confirmed that part of the fuel was dispersed downward and part of the fuel was dispersed upward, and the relocation behavior of the injected fuel proceeded simultaneously in the downward and upward directions. So, it can be concluded that in case of pressure injection of the metallic fuel, there is a possibility that the metallic fuel can be quickly removed from the core region, resulting in a negative reactivity feedback effect.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cluster Dynamics Simulations of Intra-Granular Fission Gas Bubble Size and Pressure Evolution in UO 2

Fission gases such as xenon (Xe) play a critical role in determining the behavior and response of nuclear fuel. Given that Xe has little solubility in UO 2 , it accumulates and forms bubbles, which significantly impact fuel performance. Intra- and inter-granular bubble nucleation and growth can lead to fuel swelling, and once bubbles interconnect at grain boundaries, fission gas can be released into the plenum. At low temperatures, limited uranium vacancy mobility can restrict swelling, therefore causing the bubbles to become highly pressurized. Consequently, this can induce micro-cracking, promote fission gas release (increasing the likelihood of cladding failure), and even lead to fuel pulverization under accident conditions such as a loss of coolant accident. As bubble evolution is strongly influenced by local temperature and fission rate, markedly different behavior occurs across the radial profile of the fuel pellet. Capturing the mechanisms that underpin bubble evolution is therefore important to predict these behaviors in the fuel. Previous models describing important mechanisms informed by lower length scale simulations have been developed under the NEAMS program. These can describe the evolution of a single bubble type (i.e., single value for radius and pressure) at each position in the pellet, for instance using the Centipede cluster dynamic code. However, in reality, a full distribution in bubble sizes and pressures exists within the microstructure at a given position in the pellet. To address this the cluster dynamics code Xolotl, which can predict Xe and vacancy phase space (i.e., bubble distributions) for intra-granular bubbles, has been used before. Prior work benchmarked the Xolotl code against the Centipede cluster dynamics code to ensure compatibility and to verify that mobile defect properties are adequately transferred between the two codes, along with some physics improvements. In this work, we go further by introducing a physics-based set of improvements that will allow us to accurately predict bubble size distributions and internal bubble pressures under representative UO 2 irradiation conditions. The improvements include (i) coupling bubble-defect reaction energies to a virial equation of state (EOS), (ii) including a bubble surface tension contribution, (iii) incorporating radiation-induced re-solution of Xe and vacancies, (iv) enabling pressure-driven dislocation loop punching through an effective emission of interstitial clusters informed by interstitial loop energetics, (v) accounting for radiation induced athermal diffusion of Xe, and (vi) implementing a Booth-type grain boundary sink representation for all mobile defects and defect clusters. After these modifications, we observe good agreement of Xolotl fission gas bubble size and concentration predictions with legacy experimental measurements. Additionally, it allows the distribution of Xe bubble pressures and radius to also be predicted and compared to data produced through the Advanced Fuels Campaign (AFC) program. Here, we have done this by running simulations under conditions similar to the AFC post-irradiation examination (PIE) samples irradiated at North Anna 2 light water reactor (LWR). Our results shows excellent agreement with these experimental measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Novel evaporator architecture with entrance-length crossflow-paths for supercritical Organic Rankine Cycles

Here in this article, a novel geometry is proposed for evaporators that are used in Supercritical Organic Rankine Cycles. The proposed geometry consists of successive plenums at several length-scale levels, creating a multi-scale heat exchanger (HX). The channels at the lowest length-scale levels were considered to have their length determined by the thermal entrance-length. Numerical simulations based on turbulent flow correlations for supercritical R134a and water were used to evaluate the performance of heat exchangers. Using the data on pumping power and area of heat exchange, the total present cost was evaluated using a cost model for shell-and-tube heat exchangers. With respect to the shell-and-tube baseline case, the cost per heat load and total costs of new HXs is lowered by approximately 20–26% and 15–30%, respectively. This reduction in present costs of the new HXs were found to be attributed to higher operational costs for the shell-and-tube HXs, as evidenced by the higher pumping power, as well their capital investment costs. The cost savings in the new HX designs compared to those of the shell-and-tube HXs, at similar heat load performance, indicate that the new HX architectures proposed in this paper are valid alternatives to traditional HX designs.

42 ENGINEERING↗

Enabling Staged Pressurized Oxy-Combustion: Improving Flexibility and Performance at Reduced Cost

Introduction: The staged pressurized oxy-combustion (SPOC) process, developed by Washington University in St. Louis (WUSTL), is an oxy-combustion carbon capture technology that employs a steam power cycle to generate electricity. As with atmospheric-pressure oxy-combustion processes, carbon dioxide (CO 2 ) capture rates of 90% or higher can be achieved. The staged-combustion approach of the SPOC process, when operated at elevated gas pressure, allows for near elimination of flue gas recycle (FGR) and leads to significant improvements in efficiency and reduced costs. The primary goal of this project was to investigate the potential for SPOC for flexible operation beyond the capabilities of conventional coal-fired power plants, particularly those employing carbon capture and storage (CCS). Oxy-combustion differs from conventional coal combustion in that the combustion of coal is carried out using oxygen as opposed to air. The resultant flue gas is a mixture of primarily CO 2 and water, greatly simplifying CO 2 capture. As SPOC does the oxy-combustion process under pressure, it is higher efficiency and lower cost than atmospheric oxy-combustion. The project was led by the Electric Power Research Institute, Inc., with the assistance of WUSTL, Doosan Babcock (DBL – boiler plant original equipment manufacturer), and Air Liquide (AL – air separation experts). The specific objectives of the project were to: (1) Evaluate the SPOC concept and develop a risk-based approach to the heating surface layout ensuring that performance (gas and steam side), manufacturing, transportation, and plant erection considerations were fully accounted for in the system design. (2) Improve the technology to ensure its performance and cost potential are substantially better than today’s baseline pulverized coal power plant with post-combustion capture (PCC) or atmospheric oxy-combustion, and show progress toward performance commensurate with projected commercial operation, including 90% or more CO 2 capture. (3) Address critical technology gaps and improving overall system performance for the technology. (4) Perform combustion tests at scale under commensurate pressure to the commercial operating system validate combustor and advance the SPOC combustion modeling tools that will facilitate full-scale design. Combustion Testing: Testing was initially carried out at atmospheric pressure with methane to ensure that all systems were correctly operating. Following this, the testing then proceeded to moderate pressure operation at 4 bara, where different stoichiometric conditions were used across an extended heat input range, showing that a stable flame could be maintained. Testing then proceeded at 10 and 15 bara where it was shown that the ignition system needed to be replaced at these operating conditions. When testing recommenced, a similar stable flame shape was achieved, without any methane support, and the full 100 kWth coal oxy-combustion was demonstrated. Heat flux measurements showed 400 kW/m 2 (0.126 MMBtu/hr-ft 2 ) from the flame, within the 450 kW/m 2 (0.142 MMBtu/hr-ft 2 ) preferred limit defined by DBL for the full-scale design case. Carbon monoxide and carbon-in-ash measurements showed that complete combustion was possible with ultra-low excess oxygen at 1 vol % in the product flue gas. This allowed the full-scale models to be calculated based on this level of excess oxygen, improving the performance of the system as lower feed oxygen is produced in the air separation unit (ASU), saving auxiliary power. Full-Scale Design: The full-scale design is sized to deliver 550 MWe net electrical power output to allow direct comparison with the National Energy Technology Laboratory (NETL) baseline cases using the same Montana Powder River Basin (PRB) fuel. The cases used for direct comparison are: Case S12A (supercritical [SC] coal without CO 2 capture), Case S12B (SC coal with PCC at 90% CO 2 capture, and Case S12F (atmospheric oxy-combustion SC coal with 90% CO 2 capture). The SPOC stages were configured to be identical arrangements, allowing for a more straightforward design, construction, and control strategy. Each stage consists of two PVs, the first being the combustor PV module and the second being the convective PV module. The combustor module is the tallest vessel, with local coal feeding equipment and the burner FGR and oxygen plenums at the top and ash management at the bottom. The combustor module is effectively an open cross section with membrane tubes around the circumference – this unobstructed slender profile ensures that the relatively slower burnout mechanism needed for the low-speed turbulent mixing burner can proceed unimpeded and that molten ash will not attach to any surfaces at an angle to the predominant flue gas flow. The steam turbine used in the SPOC design is essentially the same unit utilized in the atmospheric oxy-combustion case except the degree of heat recovery possible allows the low-pressure (LP) feedwater heater train to be eliminated. This is a result of being able to capture the latent heat of evaporation of the moisture produced in the combustion (normally lost to the stack). The SPOC system outperforms the NETL atmospheric oxy-combustion baseline case by 3.3% points and the PCC case by 7.5% points. This performance increase is mainly a result of the improved heat recovery possible from the product flue gas and from the reduced auxiliary power consumption from the ASU and the CO 2 compression and purification unit over the atmospheric equivalent. The combined improvement in boiler efficiency and reduction in the steam turbine heat rate resulted in a net improvement in the overall plant efficiency by 0.61%, to 35.6% on a HHV basis. This relatively small improvement in plant efficiency between sub-bituminous and bituminous coals shows the value of useful moisture latent heat recovery offered by the SPOC system when using low rank fuels. Flexibility and Turndown: The SPOC system has inherent high turndown capabilities because of a demonstrated high range of combustion stability and the ability to bypass stages, thereby reducing steam generation rates proportionally without altering firing rates in operating stages. ASU units do not generally offer significant turndown opportunities as they are limited by the performance of the compression plant. The baseline SPOC design has a 2-train ASU configuration, needed to be able to meet the 10,500 tonnes per day duty, that can deliver efficient turndown points between 85–100% load with both trains operating, and at 45–50% load with a single train operating. Outside these operating points, the flexibility and efficiency are limited and may be uncompetitive at loads below 45% as the ASU systems are unable to turndown beyond 85% for the base case and 70% for the flexible case. The ASU cold box for the flexible case was designed to operate at loads between 40-100%, below this operating range the purity of the produced oxygen cannot be guaranteed, resulting in additional load for the CPU equipment. The additional power consumption of these cases yields an uneconomic operating condition with poor efficiency when operating at low loads such as 25% and 12%. To address this flexibility constraint, AL evaluated how the ASU configuration could be altered to deliver efficient oxygen supply over the load range. This involved integrating the compressor duties across both ASU trains into a shared duty arrangement with multiple compressors, strategically sized to deliver the duty required across all load ranges between 40–100% by enabling different combinations of the main air compressors and the booster air compressors. The oxygen purity cannot be guaranteed below 40% load for each train – the power consumption at 25% and 12% loads were estimated based on the multi-compressor configuration at maximum turndown as these load cases were not considered in the flexible ASU design. With a different cold box configuration, i.e. number of trains, the entire load range could be delivered within oxygen purity specifications. Although there is a small efficiency reduction at full load, there are significant improvements in overall plant performance during low-load operation. The exact ASU configuration needed will therefore be dependent on the expected operating profile of the unit. Economic Analysis: Cost estimates for the baseline and the flexible cases were developed using NETL baseline case data for common BOP items and an Association for the Advancement of Cost Engineering International Class 5 (conceptual/screening study) assessment of key components unique to the SPOC system. The capital, operating, and maintenance costs were assessed along with the first-year power cost, levelized cost of electricity, and CO 2 captured and avoided cost for the SPOC cases were compared against the relevant NETL baseline cases in January 2019 dollars. Both SPOC cases achieve a lower cost that the alternative NETL baseline cases (with the flexible SPOC case being slightly higher than the baseline SPOC case due to the compounded impact of higher capital costs and lower efficiency at full load). The SPOC cases deliver a lower cost of CO 2 avoided than the NETL baseline cases due to greater efficiency in generating low-carbon power. However, the cost of CO 2 captured is higher because the higher efficiency of the SPOC process generates less CO 2 , hence less needs to be captured, resulting in a high capital cost being shared over a reduced CO 2 quantity. The flexible ASU adds 1.6% overall to the plant cost in comparison to the baseline case, but the efficiency improvements at loads below 50% are significant. Subsequently, depending on the plant load-profile expectation, the flexible ASU would be beneficial if the plant spends a significant portion of its operating life below 50% load. This kind of operating profile is likely to be required for all fossil plants when more renewable electricity generators are installed on the local grid, particularly solar power that can be predicted ahead of time, allowing for appropriate pricing signals to be incorporated into the diurnal cycle. R&D Recommendations: SPOC, while a promising technology, is a relatively recent concept and, as such, operability issues of combustor design and steam-side integration for such systems at a scale relevant to commercial deployment have not been evaluated. WUSTL has conducted extensive small pilot-scale (100 kWth) research to understand and advance pressurized oxy-combustion processes, including investigation of combustion and flame characteristics, radiative heat flux, burner operability, turn down, char burnout, ash characteristics, water-wash column operation, etc. for pressurized oxy-combustion systems. Nonetheless, at this stage in the development of the SPOC process, what is needed is a large-scale pilot plant that can serve to study pressurized oxy-combustion systems and components at a scale commensurate with the maturity of the technology. A scale of 10 MWth, which includes steam-side integration and two stages would yield essential information with respect to heat transfer characteristics both in the radiative and convective sections of the pressure vessels, and the ability to operate the fuel staging process. In addition, while modeling results indicate that combustion and flame characteristics improve with scale, direct studies of the combustor at this scale will ensure that the models can be relied upon for scale up to commercial scale. Furthermore, a detailed analysis must be performed to understand the scaling aspects of key components and systems.

20 FOSSIL-FUELED POWER PLANTS↗