Search NASA⌕ Search

SEARCH · Search NASA

Results for “lwir”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Radiation Tolerance Studies of Long Wavelength Infrared InAs/GaSb Detectors

In this work we investigated the effect of proton irradiation on the performance of long wavelength infrared (LWIR) InAs/GaSb photodiodes (λ(sub c) = 10.2µm) based on the complementary barrier infrared detector (CBIRD) design. We found that irradiation with 68MeV protons up to the total ionizing dose TID = 200 kRad results in only small (about 15%) decrease of the Quantum Efficiency and does not increase the operational bias of the photodiodes. However, the irradiation causes a significant increase of the dark current from j(sub d) = 5x10(exp -5) A/sq cm at V(sub b) = 0.1V and T = 80K to j(sub d) = 6x10(exp -3) A/sq cm at TID = 200 kRad. This change in the dark current mechanism can be attributed to the onset of surface leakage current, generated by the trap assisted tunneling processes in the proton displacement damage areas near the device sidewalls.

InAs/GaSb photodiodes↗

Long-wavelength 256x256 QWIP Hand-held Camera

In this paper, we discuss the development of very sensitive long wavelength infrared (LWIR) GaAs/AlxGa1-xAs quantum well infrared photodetectors (QWIPs), fabrication of random reflectors for efficient light coupling, and the demonstration of first hand-held long-wavelength 256x256 QWIP focal plane array camera. Excellent imagery, with a noise equivalent differential temperature of 25 mK has been achieved.

long↗

Stokes resolved differential temperature: an important metric of polarimetric precision in the long-wave infrared

In remote sensing, radiometric measurements taken in the mid-wave infrared and beyond (λ >3μm) are commonly reported in units of Kelvin by utilizing Planck’s radiation law to relate measured radiance and target brightness temperature (Tb). Thus, it is desirable to match this formalism in thermal polarimetry and report the unnormalized Stokes parameters in units of K instead of radiance (Wm−2sr−1). This approach also al-lows common performance metrics in long-wave infrared (LWIR) imaging such as Noise Equivalent DifferentialTemperature (NEDT) to be modified and extended to metrics of polarimetric accuracy and precision. However, since the relationship between measured radiance and Tb are non-linear, the conversion of I, Q, and U in units of radiance to Tb,Tb,Q, and Tb,U in K is ambiguous. As a solution a metric of performance for thermal linear Stokes polarimetry, the Stokes resolved differential temperature (SRDT), is introduced.

polarimetry↗

Optical Characteristics of Radiated Multifunctional Optical Materials

The performance of optical and electronic materials, and devices are affected significantly in space due to exposure from high energy radiations. We have been investigating the effect of -ray radiations on multifunctional binary and ternary selenide and halide crystals. These materials have shown excellent performance for the wavelength conversion in MWIR and LWIR regions, acousto-optics, and great potential for radiation detection. Crystals with high Z materials such as thallium, mercury and lead based compounds have great potential for the development of a variety of devices and components suitable for space applications. We will report on the characteristics of several halides including mercurous halides (Hg2X2, X= Cl, Br, I), Thallium mercury iodide (Tl4HgI4) and thallium arsenic selenide and thallium gallium selenide, and ternary selenides. These crystals, synthesized with high purity source materials, will be evaluated by studying optical characteristics and measuring resistivity after exposure to a 137Cs -ray source.

Radiation↗

Space Qualification Studies of AOTF Devices Under the MISSE-11 Mission

The acousto-optic tunable filter (AOTF) devices are used in a variety of applications including hyperspectral and spectrapolarimetric based imaging. The AOTF devices provide several advantages including speed and random access to desired spectral bands and enable all-solid-state operation that are attractive for space applications. In this paper, the performance of Tellurium Dioxide (TeO 2 ) and Mercurous Bromide (Hg 2 Br 2 ) AOTF devices in space environment carried out under the NASA’s Materials International Space Station Experiments 11 (MISSE-11) mission is discussed. The purpose of the MISSE-11 mission was to study materials and devices subjected to space conditions for long term while attached to the International Space station (ISS). The TeO 2 AOTF was developed for short wavelength IR (SWIR) operation while the Hg 2 Br 2 AOTF device was developed for long wavelength IR (LWIR) operation. These devices were attached to the ISS platform for more than a year. Pre-flight and post-flight performance characterization were performed on these devices. In the case of TeO 2 AOTF, the preflight efficiency was around 87% with a center frequency at 68MHz while the post-flight efficiency was around 83%. However, the optical transmission of Hg 2 Br 2 AOTF had deteriorated considerably. The details of performance testing and analysis of both AOTF devices are discussed.

Space Qualification↗

LWS design replacement study: Optimum design and tradeoff analysis

A design for two long-wavelength (LW) focal-plane and cooler assemblies, including associated preamplifiers and post-amplifiers is presented. The focal-planes and associated electronic assemblies are intended as direct replacement hardware to be installed into the existing 24-channel multispectral scanner used with the NASA Earth Observations Aircraft Program. An organization skilled in the art of LWIR systems can fabricate and deliver the two long-wavelength focal-plane assemblies described in this report when provided with the data and drawings developed during the performance of this contract. The concepts developed during the study including the alternative approaches and selection of components are discussed. Modifications to the preliminary design as reported in a preliminary design review meeting have also been included.

Source record↗

Scene simulation for passive IR systems

The development of large mosaic detector arrays will allow for the construction of staring long wave infrared (LWIR) sensors which can observe large fields of view instantaneously and continuously. In order to evaluate and exercise these new systems, it will be necessary to provide simulated scenes of many moving targets against an infrared clutter background. Researchers are currently developing a projector/screen system. This system is comprised of a mechanical scanner, a diffuse screen, and a miniature blackbody. A prototype of the mechanical scanner, which is comprised of four independently driven scanners, has been designed, fabricated, and evaluated under room and cryogenic vacuum conditions. A large diffuse screen has been constructed and tested for structural integrity under cryogenic/vacuum thermal cycling. Construction techniques have been developed for the fabrication of miniature high-temperature blackbody sources. Finally, a concept has been developed to use this miniature blackbody to produce a spectrally tailorable source.

Holt, J. D.↗

Broadband imaging system with three fields of view

Payload space limitations, high optical fidelity and the desirability of fast slew rates imply that certain broadband active pointing systems should be lightweight, compact and high performance with small moments of inertia. This paper describes a 12 inch diameter, F/5 reflective hybrid with two fields of view in the visible SWIR, and one field of view in the LWIR region. By incorporating two classic optical designs, these stringent requirements are met at a level as to assure reasonably attainable weight, size and performance estimates.

Manhart, Paul K.↗

Gaseous optical contamination of the spacecraft environment: A review

Interactions between the ambient atmosphere and orbiting spacecraft, sounding rockets, and suborbital vehicles, and with their effluents, give rise to optical (extreme UV to LWIR) foreground radiation which constitutes noise that raises the detection threshold for terrestrial and celestial radiations, as well as military targets. Researchers review the current information on the on-orbit optical contamination. Its source species are created in interaction processes that can be grouped into three categories: (1) Reactions in the gas phase between the ambient atmosphere and desorbates and exhaust; (2) Reactions catalyzed by exposed ram surfaces, which occur spontaneously even in the absence of active material releases from the vehicles; and (3) Erosive excitative reactions with exposed bulk (organic) materials, which have recently been identified in the laboratory though not as yet observed on spacecraft. Researchers also assess the effect of optical pumping by earthshine and sunlight of both reaction products and effluents.

Tran, N. H.↗

Sensor requirements for Earth and planetary observations

Future generations of Earth and planetary remote sensing instruments will require extensive developments of new long-wave and very long-wave infrared detectors. The upcoming NASA Earth Observing System (EOS) will carry a suite of instruments to monitor a wide range of atmospheric and surface parameters with an unprecedented degree of accuracy for a period of 10 to 15 years. These instruments will observe Earth over a wide spectral range extending from the visible to nearly 17 micrometers with a moderate to high spectral and spacial resolution. In addition to expected improvements in communication bandwidth and both ground and on-board computing power, these new sensor systems will need large two-dimensional detector arrays. Such arrays exist for visible wavelengths and, to a lesser extent, for short wavelength infrared systems. The most dramatic need is for new Long Wavelength Infrared (LWIR) and Very Long Wavelength Infrared (VLWIR) detector technologies that are compatible with area array readout devices and can operate in the temperature range supported by long life, low power refrigerators. A scientific need for radiometric and calibration accuracies approaching 1 percent translates into a requirement for detectors with excellent linearity, stability and insensitivity to operating conditions and space radiation. Current examples of the kind of scientific missions these new thermal IR detectors would enhance in the future include instruments for Earth science such as Orbital Volcanological Observations (OVO), Atmospheric Infrared Sounder (AIRS), Moderate Resolution Imaging Spectrometer (MODIS), and Spectroscopy in the Atmosphere using Far Infrared Emission (SAFIRE). Planetary exploration missions such as Cassini also provide examples of instrument concepts that could be enhanced by new IR detector technologies.

Chahine, Moustafa T.↗

A novel electron tunneling infrared detector

The pneumatic infrared detector, originally developed by Golay in the late 1940s, uses the thermal expansion of one cm(exp 3) of xenon at room temperature to detect the heat deposited by infrared radiation. This detector was limited by thermal fluctuations within a 10 Hz bandwidth, but suffered from long thermal time constants and a fragile structure. Nevertheless, it represents the most sensitive room temperature detector currently available in the long wavelength infrared (LWIR). Fabrication of this type of detector on smaller scales has been limited by the lack of a suitably sensitive transducer. Researchers designed a detector based on this principle, but which is constructed entirely from micromachined silicon, and uses a vacuum tunneling transducer to detect the expansion of the trapped gas. Because this detector is fabricated using micromachining techniques, miniaturization and integration into one and two-dimensional arrays is feasible. The extreme sensitivity of vacuum tunneling to changes in electrode separation will allow a prototype of this detector to operate in the limit of thermal fluctuations over a 10 kHz bandwidth. A calculation of the predicted response and noise of the prototype is presented with the general formalism of thermal detectors. At present, most of the components of the prototype have been fabricated and tested independently. In particular, a characterization of the micromachined electron tunneling transducer has been carried out. The measured noise in the tunnel current is within a decade of the limit imposed by shot noise, and well below the requirements for the operation of an infrared detector with the predicted sensitivity. Assembly and characterization of the prototype infrared detector will be carried out promptly.

Kenny, T. W.↗

Growth and properties of Hg-based quantum well structures and superlattices

An overview of the properties of HgTe-CdTe quantum well structures and superlattices (SL) is presented. These new quantum structures are candidates for use as new long wavelength infrared (LWIR) and very long wavelength infrared (VLWIR) detectors, as well as for other optoelectronic applications. Much has been learned within the past two years about the physics of such structures. The valence band offset has been determined to be approx. 350 meV, independent of temperature. The occurrence of electron and hole mobilities in excess of 10(exp 5)cm(exp 2)/V center dot s is now understood on the basis of SL band structure calculations. The in-plane and out-of-plane electron and hole effective masses have been measured and interpreted theoretically for HgTe-CdTe superlattices. Controlled substitutional doping of superlattices has recently been achieved at North Carolina State University (NCSU), and modulation-doped SLs have now been successfully grown and studied. Most recently, a dramatic lowering of the growth temperature of Hg-based quantum well structure and SLs (to approx. 100 C) has been achieved by means of photoassisted molecular beam epitaxy (MBE) at NCSU. A number of new devices have been fabricated from these doped multilayers.

Schetzina, J. F.↗

Boeing infrared sensor (BIRS) calibration facility

The Boeing Infrared Sensor (BIRS) Calibration Facility represents a major capital investment in optical and infrared technology. The facility was designed and built for the calibration and testing of the new generation large aperture long wave infrared (LWIR) sensors, seekers, and related technologies. Capability exists to perform both radiometric and goniometric calibrations of large infrared sensors under simulated environmental operating conditions. The system is presently configured for endoatmospheric calibrations with a uniform background field which can be set to simulate the expected mission background levels. During calibration, the sensor under test is also exposed to expected mission temperatures and pressures within the test chamber. Capability exists to convert the facility for exoatmospheric testing. The configuration of the system is described along with hardware elements and changes made to date are addressed.

Hazen, John D.↗

Advanced Si IR detectors using molecular beam epitaxy

SiGe/Si heterojunction internal photoemission (HIP) long wavelength infrared (LWIR) detectors have been fabricated by MBE. The SiGe/Si HIP detector offers a tailorable spectral response in the long wavelength infrared regime by varying the SiGe/Si heterojunction barrier. Degenerately doped p(+) SiGe layers were grown using elemental boron, as the dopant source allows a low growth temperature. Good crystalline quality was achieved for boron-doped SiGe due to the reduced growth temperature. The dark current density of the boron-doped HIP detectors was found to be thermionic emission limited. HIP detectors with a 0.066 eV were fabricated and characterized using activation energy analysis, corresponding to a 18 micron cutoff wavelength. Photoresponse of the detectors at wavelengths ranging from 2 to 12 microns has been characterized with corresponding quantum efficiencies of 5 - 0.1 percent.

Lin, T. L.↗

Clementine: Anticipated scientific datasets from the Moon and Geographos

The Clementine spacecraft mission is designed to test the performance of new lightweight and low-power detectors developed at the Lawrence Livermore National Laboratory (LLNL) for the Strategic Defense Initiative Office (SDIO). A secondary objective of the mission is to acquire useful scientific data, principally of the Moon and the near-Earth asteroid Geographos. The spacecraft will be in an elliptical polar orbit about the Moon for about 2 months beginning in February of 1994 and it will fly by Geographos on August 31. Clementine will carry seven detectors each weighing less than about 1 kg: two Star Trackers wide-angle uv/vis wide-angle Short Wavelength IR (SWIR) Long-Wavelength IR (LWIR) and LIDAR (Laser Image Detection And Ranging) narrow-angle imaging and ranging. Additional presentations about the mission detectors and related science issues are in this volume. If fully successful Clementine will return about 3 million lunar images, a dataset with nearly as many bits of data (uncompressed) as the first cycle of Magellan and more than 5000 images of Geographos. The complete and efficient analysis of such large data sets requires systematic processing efforts. Described below are concepts for two such efforts for the Clementine mission: global multispectral imaging of the Moon and videos of the Geographos flyby. Other anticipated datasets for which systematic processing might be desirable include multispectral observations of Earth; LIDAR altimetry of the Moon with high-resolution imaging along each ground track; high-resolution LIDAR color along each lunar ground track which could be used to identify potential titanium-rich deposits at scales of a few meters; and thermal IR imaging along each lunar ground track (including nighttime observations near the poles).

Mcewen, A. S.↗

Evolution of miniature detectors and focal plane arrays for infrared sensors

Sensors that are sensitive in the infrared spectral region have been under continuous development since the WW2 era. A quest for the military advantage of 'seeing in the dark' has pushed thermal imaging technology toward high spatial and temporal resolution for night vision equipment, fire control, search track, and seeker 'homing' guidance sensing devices. Similarly, scientific applications have pushed spectral resolution for chemical analysis, remote sensing of earth resources, and astronomical exploration applications. As a result of these developments, focal plane arrays (FPA) are now available with sufficient sensitivity for both high spatial and narrow bandwidth spectral resolution imaging over large fields of view. Such devices combined with emerging opto-electronic developments in integrated FPA data processing techniques can yield miniature sensors capable of imaging reflected sunlight in the near IR and emitted thermal energy in the Mid-wave (MWIR) and longwave (LWIR) IR spectral regions. Robotic space sensors equipped with advanced versions of these FPA's will provide high resolution 'pictures' of their surroundings, perform remote analysis of solid, liquid, and gas matter, or selectively look for 'signatures' of specific objects. Evolutionary trends and projections of future low power micro detector FPA developments for day/night operation or use in adverse viewing conditions are presented in the following test.

Watts, Louis A.↗