Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Mass-additive modal test method for verification of constrained structural models

A method for deriving constrained or fixed-base modes and frequencies from free-free modes of a structure with mass-loaded boundaries is developed. Problems associated with design and development of test fixtures can be avoided with such an approach. The analytical methodology presented is used to assess applicability of the mass-additive method for three types of structures and to determine the accuracy of derived constrained modes and frequencies. Results show that mass loading of the boundaries enables local interface modes to be measured within a desired frequency bandwidth, thus allowing constrained modes to be derived with considerably fewer free-free modes than for unloaded boundaries. Good convergence was obtained for a simple beam and a truss-like Shuttle payload, both of which had well-spaced modes and stiff interface support structures. Slow convergence was obtained for a space station module prototype, a shell-like structure having high modal density.

Admire, John R.↗

Masses of Black Holes in Active Galactic Nuclei

We present a progress report on a project whose goal is to improve both the precision and accuracy of reverberation-based black-hole masses. Reverberation masses appear to be accurate to a factor of about three, and the black-hole mass/bulge velocity dispersion (M-sigma) relationship appears to be the same in active and quiescent galaxies.

Peterson, Bradley M.↗

Mass transfer from a circular cylinder: Effects of flow unsteadiness and slight nonuniformities

Experiments were performed to determine the effect of periodic variations in the angle of the flow incident to a turbine blade on its leading edge heat load. To model this situation, measurements were made on a circular cylinder oscillating rotationally in a uniform steady flow. A naphthalene mass transfer technique was developed and used in the experiments and heat transfer rates are inferred from the results. The investigation consisted of two parts. In the first, a stationary cylinder was used and the transfer rate was measured for Re = 75,000 to 110,000 and turbulence levels from .34 percent to 4.9 percent. Comparisons with both theory and the results of others demonstrate that the accuracy and repeatability of the developed mass transfer technique is about + or - 2 percent, a large improvement over similar methods. In the second part identical flow conditions were used but the cylinder was oscillated. A Strouhal number range from .0071 to .1406 was covered. Comparisons of the unsteady and steady results indicate that the magnitude of the effect of oscillation is small and dependent on the incident turbulence conditions.

Marziale, M. L.↗

Modeling and new equipment definition for the vibration isolation box equipment system

Our MSAD-funded research project is to provide numerical modeling support for the VIBES (Vibration Isolation Box Experiment System) which is an IML2 flight experiment being built by the Japanese research team of Dr. H. Azuma of the Japanese National Aerospace Laboratory. During this reporting period, the following have been accomplished: A semi-consistent mass finite element projection algorithm for 2D and 3D Boussinesq flows has been implemented on Sun, HP And Cray Platforms. The algorithm has better phase speed accuracy than similar finite difference or lumped mass finite element algorithms, an attribute which is essential for addressing realistic g-jitter effects as well as convectively-dominated transient systems. The projection algorithm has been benchmarked against solutions generated via the commercial code FIDAP. The algorithm appears to be accurate as well as computationally efficient. Optimization and potential parallelization studies are underway. Our implementation to date has focused on execution of the basic algorithm with at most a concern for vectorization. The initial time-varying gravity Boussinesq flow simulation is being set up. The mesh is being designed and the input file is being generated. Some preliminary 'small mesh' cases will be attempted on our HP9000/735 while our request to MSAD for supercomputing resources is being addressed. The Japanese research team for VIBES was visited, the current set up and status of the physical experiment was obtained and ongoing E-Mail communication link was established.

Sani, Robert L.↗

Echocardiographic measurements of left ventricular mass by a non-geometric method

The accuracy of a new nongeometric method for calculating left ventricular myocardial volumes from two-dimensional echocardiographic images was assessed in vitro using 20 formalin-fixed normal human hearts. Serial oblique short-axis images were acquired from one point at 5-deg intervals, for a total of 10-12 cross sections. Echocardiographic myocardial volumes were calculated as the difference between the volumes defined by the epi- and endocardial surfaces. Actual myocardial volumes were determined by water displacement. Volumes ranged from 80 to 174 ml (mean 130.8 ml). Linear regression analysis demonstrated excellent agreement between the echocardiographic and direct measurements.

Parra, Beatriz↗

Small Inertial Measurement Units- Sources of Error and Limitations on Accuracy

Inertial measurement units (IMUs) with very low mass and power can be manufactured using micromachined accelerometers and gyroscopes. Six degree of freedom packages which require a few watts of power and have less than a kg of mass are available commercially, greatly expanding the potential applications of IMUs in guidance and navigation. Recent advances in small sensor design and fabrication have pushed the performance limits of these small devices. However, the limitations on the precision of small IMUs are not entirely due to the performance of the individual sensors.

Hoenk, Michael E.↗

Slow-Neutron Scattering by Rotators. II

The methods developed in a previous paper for extending the neutron scattering formalism of Zemach and Glauber to any type of molecular rotator have been employed to derive generalized forms generalized forms of the differential cross sections for rotator scattering. A mass-ratio expansion for the treatment of the high-energy limit is illustrated on the classical cross section and then employed in the treatment of the more general quantum-mechanical expression for the differential cross section. The results apply to an arbitrarily asymmetric rotator. The very low energy approximation is carried out for the symmetric rotator, and the procedure is compared with the explicit summing of the partial cross sections for individual rotational transitions. The inelastic correction to the static approximation for interference scattering is calculated to an accuracy of first order in the mass ratios for the case of the symmetric rotator.

Volkin, Howard C.↗

Mass Inferencing Model Creation and Deployment to the RASSOR Lunar Excavation Robot

The Regolith Advanced Surface Systems Operations Robot (RASSOR) Excavator is a teleoperated mobile robotic platform with a unique space regolith excavation capability. The Intelligent Capabilities Enhanced RASSOR research project developed functionality for inferencing regolith mass ingested during RASSOR operation, enhancing RASSOR’s ability to successfully complete ISRU missions. To teleoperate or run autonomously, it is crucial for the quantity of regolith mass ingested by RASSOR to be available as a system state for efficient operation. For example, during autonomous operation, RASSOR should navigate and move to a processing plant to offload the collected regolith when the drums are full; without knowledge of how much mass is in the drums, this type of high-level planning is not possible. Four distinct modeling approaches were employed in developing a mass inferencing approach that could work on RASSOR. All take in system states, such as arm/drum positions, velocities, currents, voltages, and robot pose, and output a mass prediction for each set of the robot’s bucket drums.1) A neural network model that takes a vector of normalized system states; 2) A model that uses the integrated power consumption of an arm-raise (normalized by velocity); 3) A model that uses average drum current over a variable length interval of the drum disengaged from the surface; and 4) A real-time estimation model that aggregates excavation drum current. The developed models run in real time, outputting predictions for the front and rear drums, timestamp of the last prediction, and total mass in RASSOR’s drums. Further testing is required to validate the arm-raise model (2), though initial tests indicate reasonable performance (<10% mean error) on the hardware. The linear fit of average drum-current model (3) had a front value of r^2=0.99 and a rear value of r^2=0.98 on the validation dataset. This model currently has the best performance on unseen data. The real time model (4) is still in development, though initial results on a small subset of the training data show that it has high accuracy in predicting the increase in mass during excavation. Though work remains to be done with deploying a high-fidelity model to the physical system that makes predictions with error below the desired threshold, the modular architecture for model development allows quick adjustment of parameters to increase model fidelity. This architecture can also be adapted to use lunar excavation data to create models that are reflective of RASSOR’s dynamics when operating on the lunar surface. The results are promising as it has been shown that models can be developed that accurately estimate excavated regolith mass.

rassor↗

Astrophysics to z approx. 10 with Gravitational Waves

The most useful characterization of a gravitational wave detector's performance is the accuracy with which astrophysical parameters of potential gravitational wave sources can be estimated. One of the most important source types for the Laser Interferometer Space Antenna (LISA) is inspiraling binaries of black holes. LISA can measure mass and spin to better than 1% for a wide range of masses, even out to high redshifts. The most difficult parameter to estimate accurately is almost always luminosity distance. Nonetheless, LISA can measure luminosity distance of intermediate-mass black hole binary systems (total mass approx.10(exp 4) solar mass) out to z approx.10 with distance accuracies approaching 25% in many cases. With this performance, LISA will be able to follow the merger history of black holes from the earliest mergers of proto-galaxies to the present. LISA's performance as a function of mass from 1 to 10(exp 7) solar mass and of redshift out to z approx. 30 will be described. The re-formulation of LISA's science requirements based on an instrument sensitivity model and parameter estimation will be described.

Stebbins, Robin↗

Triply eclipsing triple stars in the northern TESS fields: TICs 193993801, 388459317, and 52041148

In this work we report the discovery and analysis of three new triply eclipsing triple star systems found with the TESS mission during its observations of the northern skies: TICs 193993801, 388459317, and 52041148. We utilized the TESS precision photometry of the binary eclipses and third-body eclipsing events, ground-based archival and follow-up photometric data, eclipse timing variations, archival spectral energy distributions, as well as theoretical evolution tracks in a joint photodynamical analysis to deduce the system masses and orbital parameters of both the inner and outer orbits. In one case (TIC 193993801) we also obtained radial velocity measurements of all three stars. This enabled us to `calibrate' our analysis approach with and without `truth' (i.e., RV) data. We find that the masses are good to 1-3% accuracy with RV data and 3-10% without the use of RV data. In all three systems we were able to find the outer orbital period before doing any detailed analysis by searching for a longer-term periodicity in the ASAS-SN archival photometry data -- just a few thousand ASAS-SN points enabled us to find the outer periods of 49.28 d, 89.86 d, and 177.0 d, respectively. From our full photodynamical analysis we find that all three systems are coplanar to within 1 ∘ −3 ∘ . The outer eccentricities of the three systems are 0.003, 0.10, and 0.62, respectively (i.e., spanning a factor of 200). The masses of the three stars {Aa, Ab, and B} in the three systems are: {1.31, 1.19, 1.34}, {1.82, 1.73, 2.19}, and {1.62, 1.48, 2.74} M ⊙ , respectively.

Tamás Borkovits↗

Development of a Miniature, Two-Axis, Triple-Helmholtz-Driven Gimbal

This paper details the development of a Helmholtz-driven, 2-axis gimbal to position a flat mirror within 50 microradian (fine positioning) in a space environment. The gimbal is intended to travel on a deep space mission mounted on a miniature "rover" vehicle. The gimbal will perform both pointing and scanning functions. The goal for total mass of the gimbal was 25 grams. The primary challenge was to design and build a bearing system that would achieve the required accuracy in addition to supporting the relatively large mass of the mirror and the outer gimbal. The mechanism is subjected to 100-G loading without the aid of any additional caging mechanism. Additionally, it was desired to have the same level of accuracy during Earth-bound, 1-G testing. Due to the inherent lack of damping in a zero-G, vacuum environment; the ability of the gimbal to respond to very small amounts of input energy is paramount. Initial testing of the first prototype revealed exceedingly long damping times required even while exposed to the damping effects of air and 1-G friction. It is envisioned that fine positioning of the gimbal will be accomplished in very small steps to avoid large disturbances to the mirror. Various bearing designs, including materials, lubrication options and bearing geometry will be discussed. In addition various options for the Helmholtz coil design will be explored with specific test data given. Ground testing in the presence of 1-G was compounded by the local magnetic fields due to the "compass" effect on the gimbal. The test data will be presented and discussed. Additionally, rationale for estimating gimbal performance in a zero-G environment will be presented and discussed.

Sharif, Boz↗

Fabrication and Thermo-Optical Properties of the MLS Composite Primary Reflector

The Microwave Limb Sounder (MLS) is a limb-sounding radiometer sensing emissions in the millimeter and sub-millimeter range. MLS will contribute to an understanding of atmospheric chemistry by assessing stratospheric and tropospheric ozone depletion, climate forcings and volcanic effects. The heart of the antenna is the primary reflector, constructed from graphite/cyanate composites in a facesheet/core construction. The reflector has an aperture of one square meter, a mass of 8.7 kilos and final figure accuracy of 4.37 microns rms. The surface is also modified to ensure RF reflectivity, prevent solar concentration and provide thermal balance to the spacecraft The surface is prepared by precision beadblasting, then coated with vapor deposited aluminum (VDA) and finally a layer of silicon suboxide (SiO(x)) to control the infrared emissivity. The resulting surface has a solar absorptance of 0.43 and an absorptance/emittance ratio of 1.3. BRDF analysis shows that 93% of the incident thermal energy is reflected outside a 10 degree angle of cone. For its mass and aperture, we believe this reflector to have the highest figure accuracy yet achieved in a composite antenna construction.

Willis, Paul B.↗

Simulation Study of a Follow-on Gravity Mission to GRACE

The gravity recovery and climate experiment (GRACE) has been providing monthly estimates of the Earth's time-variable gravity field since its launch in March 2002. The GRACE gravity estimates are used to study temporal mass variations on global and regional scales, which are largely caused by a redistribution of water mass in the Earth system. The accuracy of the GRACE gravity fields are primarily limited by the satellite-to-satellite range-rate measurement noise, accelerometer errors, attitude errors, orbit errors, and temporal aliasing caused by unmodeled high-frequency variations in the gravity signal. Recent work by Ball Aerospace and Technologies Corp., Boulder, CO has resulted in the successful development of an interferometric laser ranging system to specifically address the limitations of the K-band microwave ranging system that provides the satellite-to-satellite measurements for the GRACE mission. Full numerical simulations are performed for several possible configurations of a GRACE Follow-On (GFO) mission to determine if a future satellite gravity recovery mission equipped with a laser ranging system will provide better estimates of time-variable gravity, thus benefiting many areas of Earth systems research. The laser ranging system improves the range-rate measurement precision to approximately 0.6 nm/s as compared to approx. 0.2 micro-seconds for the GRACE K-band microwave ranging instrument. Four different mission scenarios are simulated to investigate the effect of the better instrument at two different altitudes. The first pair of simulated missions is flown at GRACE altitude (approx. 480 km) assuming on-board accelerometers with the same noise characteristics as those currently used for GRACE. The second pair of missions is flown at an altitude of approx. 250 km which requires a drag-free system to prevent satellite re-entry. In addition to allowing a lower satellite altitude, the drag-free system also reduces the errors associated with the accelerometer. All simulated mission scenarios assume a two satellite co-orbiting pair similar to GRACE in a near-polar, near-circular orbit. A method for local time variable gravity recovery through mass concentration blocks (mascons) is used to form simulated gravity estimates for Greenland and the Amazon region for three GFO configurations and GRACE. Simulation results show that the increased precision of the laser does not improve gravity estimation when flown with on-board accelerometers at the same altitude and spacecraft separation as GRACE, even when time-varying background models are not included. This study also shows that only modest improvement is realized for the best-case scenario (laser, low-altitude, drag-free) as compared to GRACE due to temporal aliasing errors. These errors are caused by high-frequency variations in the hydrology signal and imperfections in the atmospheric, oceanographic, and tidal models which are used to remove unwanted signal. This work concludes that applying the updated technologies alone will not immediately advance the accuracy of the gravity estimates. If the scientific objectives of a GFO mission require more accurate gravity estimates, then future work should focus on improvements in the geophysical models, and ways in which the mission design or data processing could reduce the effects of temporal aliasing.

Loomis, Bryant D.↗

A New Era in Geodesy and Cartography: Implications for Landing Site Operations

The Mars Global Surveyor (MGS) Mars Orbiter Laser Altimeter (MOLA) global dataset has ushered in a new era for Mars local and global geodesy and cartography. These data include the global digital terrain model (Digital Terrain Model (DTM) radii), the global digital elevation model (Digital Elevation Model (DEM) elevation with respect to the geoid), and the higher spatial resolution individual MOLA ground tracks. Currently there are about 500,000,000 MOLA points and this number continues to grow as MOLA continues successful operations in orbit about Mars, the combined processing of radiometric X-band Doppler and ranging tracking of MGS together with millions of MOLA orbital crossover points has produced global geodetic and cartographic control having a spatial (latitude/longitude) accuracy of a few meters and a topographic accuracy of less than 1 meter. This means that the position of an individual MOLA point with respect to the center-of-mass of Mars is know to an absolute accuracy of a few meters. The positional accuracy of this point in inertial space over time is controlled by the spin rate uncertainty of Mars which is less than 1 km over 10 years that will be improved significantly with the next landed mission.

Duxbury, T. C.↗

Stability and accuracy analysis of some fully-discrete algorithms for the one-dimensional second-order wave equation

The present investigation is concerned with some basic results for a predictor-multicorrector algorithm applied to the one-dimensional wave equation, giving particular attention to so-called 2-pass explicit schemes in which both lumped and coupled mass matrices are employed. In an assessment of the accuracy and stability properties of the algorithms, use is made of the one-dimensional, second-order wave equation. The maximum stable time step of the lumped right-hand-side mass, 2-pass explicit algorithm is twice that of the 1-pass explicit algorithm. Improved accuracy is obtained by employing higher-order, or consistent, right-hand-side, mass.

Hughes, T. J. R.↗

On the Conservative Interface Treatment for Multi-Block Viscous Flow Computations

A pressure-based multi-block computational method is developed for solving the incompressible Navier-Stokes equations in general curvilinear grid systems. The scheme is based on the semi-implicit type flow solver with the staggered grid. Issues concerning the mass and momentum flux treatments at the discontinuous grid interface are addressed. Systematic numerical experiments for different interface treatments involving (1) straightforward interpolation, (2) globally conservative scheme, and (3) locally conservative scheme have been conducted. It is demonstrated that mass conservation has to be maintained locally, at the grid interface, with accuracy compatible with that of the scheme used in interior domain. Direct interpolation or globally conservative interface treatment of mass flux can not yield solutions with desirable accuracy.

Liu, J.↗

Precision Measurement of Complete Black Hole Binary Inspiral-Merger-Ringdown Signals with LISA

Until recently, only the inspiral and ringdown phases of black hole binary (131-113) coalescences had been modeled. The merger signals, which were expected to be the most luminous portion of the total signal, were unavailable due to the technical difficulty of calculating the behavior of a BHB in this highly dynamical and non-linear regime. Advancements in the field of numerical relativity make it possible to include the merger segment of 131113 coalescence in the search for and characterization of gravitational wave signals. The implications for LISA include an increase in the event rate due to the increase in achievable signal-to-noise ratio, as well as potentially improved accuracy regarding the extraction of the source parameters. We investigate the degree to which mergers improve parameter estimation, by studying the impact of including mergers on achievable parameter accuracy over a significant range of masses and mass ratios for nonspinning systems, and its impact on LISA science.