Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Leptonic scalars and collider signatures in a UV-complete model

We study the non-standard interactions of neutrinos with light leptonic scalars ( ϕ ) in a global ( B – L )-conserved ultraviolet (UV)-complete model. The model utilizes Type-II seesaw motivated neutrino interactions with an SU(2) L -triplet scalar, along with an additional singlet in the scalar sector. This UV-completion leads to an enriched spectrum and consequently new observable signatures. We examine the low-energy lepton flavor violation constraints, as well as the perturbativity and unitarity constraints on the model parameters. Then we lay out a search strategy for the unique signature of the model resulting from the leptonic scalars at the hadron colliders via the processes H ±± → W ± W ± ϕ and H ± → W ± ϕ for both small and large leptonic Yukawa coupling cases. We find that via these associated production processes at the HL-LHC, the prospects of doubly-charged scalar H ±± can reach up to 800 (500) GeV and 1.1 (0.8) TeV at the 2 σ (5 σ ) significance for small and large Yukawa couplings, respectively. A future 100 TeV hadron collider will further increase the mass reaches up to 3.8 (2.6) TeV and 4 (2.7) TeV, at the 2 σ (5 σ ) significance, respectively. We also demonstrate that the mass of ϕ can be determined at about 10% accuracy at the LHC for the large Yukawa coupling case even though it escapes as missing energy from the detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low global warming potential (GWP) refrigerant supermarket refrigeration system modeling and its application

As an environmentally friendly low global warming potential (GWP) refrigerant, Carbon dioxide (CO 2 ) has continuously gained popularity and research attention as alternative refrigerant for supermarket refrigeration system. In this paper, to fulfill the increasing need of accurate Low-GWP supermarket refrigeration models for development of supervisory level control and optimization strategies, a high fidelity model is developed for CO 2 transcritical supermarket refrigeration system which includes compressor rack of low temperature (LT) compressors and medium temperature (MT) compressors, air-cooled gas cooler, evaporator, expansion valves and other auxiliary equipment. A resistance-capacity model structure is proposed to simulate the display cases. Semi-thermodynamic models are proposed to estimate reciprocating compressors volumetric efficiency and power consumption. Furthermore the zone modeling approach is used for evaporator simulation, and air-cooled gas cooler is modeled with distributed modeling method. The expansion valve simulation is based on orifice flow model. To calibrate these models, both manufacture performance data and experimental data are used. The experiments are conducted with a full instrumental CO 2 supermarket refrigeration system installed in Oak Ridge National Lab Flexible Research Platform (FRP). The simulation model can predict the system performance, including power consumption, cooling capacity, mass flow rate, temperature, and pressure, with high accuracy (within ±4%) compared to experimental data. In addition, this developed model has been used to create the system optimum high side pressure for high side expansion valve control, and to generate wide operating range simulation data for developing the batter-equivalent commercial refrigeration system model which can be used in grid interactive control development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts

An accelerometer mounting technique has large implications on the frequency range and accuracy of the measurement, with stiffness and the mass relative to the monitored structure as the primary concerns. The International Organization for Standardization (ISO) gives an extensive list in 5348:2021, detailing mounting methods, and provides recommendations for testing mounts that are not specifically defined. In the nuclear industry on the laboratory scale, there is a need for vibration measurements for predictive maintenance and process monitoring that are nondestructive and capable of working in high-temperature environments. Commercial adhesive products with easy application and removal were tested as nondestructive methods, while quick mounts to a commonly used aluminum frame were tested as nondestructive and have potential applicability in high-temperature environments. The sinusoidal excitation method was used, measuring frequencies from 50 Hz to 10 kHz in one-third octave band intervals, utilizing three accelerometers and comparing the results to those obtained with the stud-mounting method. Using the lowest ±3 dB threshold across each accelerometer, foam dots and poster strips were not successful, and foam tapes were accurate up to 2000 Hz, hose clamps and zip ties up to 800 Hz, and a custom 3D printed mount up to 1000 Hz. Knowing the limitations of each mounting technique allows for accurate measurements within the appropriate range.

47 - OTHER INSTRUMENTATION↗

Discovering type I cis-AT polyketides through computational mass spectrometry and genome mining with Seq2PKS

Type 1 polyketides are a major class of natural products used as antiviral, antibiotic, antifungal, antiparasitic, immunosuppressive, and antitumor drugs. Analysis of public microbial genomes leads to the discovery of over sixty thousand type 1 polyketide gene clusters. However, the molecular products of only about a hundred of these clusters are characterized, leaving most metabolites unknown. Characterizing polyketides relies on bioactivity-guided purification, which is expensive and time-consuming. To address this, we present Seq2PKS, a machine learning algorithm that predicts chemical structures derived from Type 1 polyketide synthases. Seq2PKS predicts numerous putative structures for each gene cluster to enhance accuracy. The correct structure is identified using a variable mass spectral database search. Benchmarks show that Seq2PKS outperforms existing methods. Applying Seq2PKS to Actinobacteria datasets, we discover biosynthetic gene clusters for monazomycin, oasomycin A, and 2-aminobenzamide-actiphenol.

60 APPLIED LIFE SCIENCES↗

Metabolite discovery through global annotation of untargeted metabolomics data

Liquid chromatography–high-resolution mass spectrometry (LC-MS)-based metabolomics aims to identify and quantify all metabolites, but most LC-MS peaks remain unidentified. Here we present a global network optimization approach, NetID, to annotate untargeted LC-MS metabolomics data. The approach aims to generate, for all experimentally observed ion peaks, annotations that match the measured masses, retention times and (when available) tandem mass spectrometry fragmentation patterns. Peaks are connected based on mass differences reflecting adduction, fragmentation, isotopes, or feasible biochemical transformations. Global optimization generates a single network linking most observed ion peaks, enhances peak assignment accuracy, and produces chemically informative peak–peak relationships, including for peaks lacking tandem mass spectrometry spectra. Applying this approach to yeast and mouse data, we identified five previously unrecognized metabolites (thiamine derivatives and N-glucosyl-taurine). Isotope tracer studies indicate active flux through these metabolites. Furthermore, NetID applies existing metabolomic knowledge and global optimization to substantially improve annotation coverage and accuracy in untargeted metabolomics datasets, facilitating metabolite discovery.

59 BASIC BIOLOGICAL SCIENCES↗

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Inlet Throttling on Thermohydraulic Instability in a Large Scale Waterbased RCCS: A System-Level Analysis with RELAP5-3D

This paper presents results from system -level modeling of a water -based reactor cavity cooling system using RELAP5-3D. The computational model is benchmarked with experimental data from a half -scale RCCS test facility at Argonne National Laboratory. The model prediction is first compared with a two-phase oscillatory baseline experimental case where mixed accuracy is obtained. The model shows reasonable prediction of mass flow rate, pressure, and temperature but significant overprediction of void fraction. The model prediction is then compared with a fault case where the inlet of the risers is gradually reduced using a throttling valve. As the valve is closed, the model is able to predict some major flow phenomena observed in the experiment such as the dampening of oscillations, the reintroduction of oscillations, as well as boiling, flashing, and geysering in the risers. However, the timeline of these events are not well captured by the model. The model is also used to investigate the evolution of flow regime in the chimney. This work highlights that the semiempirical constitutive relations used in RELAP-3D could have a strong influence on the accuracy of the model in two-phase oscillatory flows.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

How to measure the W Mass: A Theory Perspective [Slides]

CDF used ResBos code at NNLL+NLO accuracy. ResBos v2 is able to go to N 3 LL+NNLO accuracy. ResBos2 corrected major criticism of incorrect angular functions in the ResBos code. Mimic CDF analysis using pseudoexperiments at N 3 LL+NNLO accuracy. We report find shift to be consistent with 0 MeV and up to 10 MeV in worse case.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

How to measure the W Mass: A Theory Perspective [Slides]

CDF used ResBos code at NNLL+NLO accuracy. ResBos v2 is able to go to N 3 LL+NNLO accuracy. ResBos2 corrected major criticism of incorrect angular functions in the ResBos code. Mimic CDF analysis using pseudoexperiments at N 3 LL+NNLO accuracy. We report find shift to be consistent with 0 MeV and up to 10 MeV in worse case.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring Signatures of Fuel Irradiation in Large Particle Samples

Understanding the operating history of a nuclear facility is one of the key goals in nuclear safeguards, enabling the verification of declared activities. This is accomplished via a number of mechanisms, including the analysis of samples collected at the facility. The best metrics for understanding and verifying the history of nuclear fuel are (1) actinide isotopic content and (2) actinide inter-element ratios. While techniques have long existed for measuring these values with high accuracy and precision in bulk samples, as samples become smaller – such as may be collected in environmental collection – new methods are required both for clean processing of pure samples, and for analysis of these small samples. This study describes a new extraction chromatography technique for recovering U, Pu, and Am from single small aliquots, and advanced mass spectrometry methods for high-precision and high-accuracy analysis of trace and ultra-trace levels of actinides. These techniques are applied to particle samples cut from fuel from a historic nuclear reactor. Ages calculated from Pu–Am chronometry of particles are in excellent agreement with the known operating history of the reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Smart System for the Contactless Measurement of Energy Expenditure

Energy Expenditure (EE) (kcal/day), a key element to guide obesity treatment, is measured from CO 2 production, VCO 2 (mL/min), and/or O 2 consumption, VO 2 (mL/min). Current technologies are limited due to the requirement of wearable facial accessories. A novel system, the Smart Pad, which measures EE via VCO 2 from a room’s ambient CO 2 concentration transients was evaluated. Resting EE (REE) and exercise VCO 2 measurements were recorded using Smart Pad and a reference instrument to study measurement duration’s influence on accuracy. The Smart Pad displayed 90% accuracy (±1 SD) for 14–19 min of REE measurement and for 4.8–7.0 min of exercise, using known room’s air exchange rate. Additionally, the Smart Pad was validated measuring subjects with a wide range of body mass indexes (BMI = 18.8 to 31.4 kg/m2), successfully validating the system accuracy across REE’s measures of ~1200 to ~3000 kcal/day. Furthermore, high correlation between subjects’ VCO 2 and λ for CO 2 accumulation was observed (p < 0.00001, R = 0.785) in a 14.0 m3 sized room. This finding led to development of a new model for REE measurement from ambient CO 2 without λ calibration using a reference instrument. The model correlated in nearly 100% agreement with reference instrument measures (y = 1.06x, R = 0.937) using an independent dataset (N = 56).

47 OTHER INSTRUMENTATION↗

An Extended Halo-based Group/Cluster Finder: Application to the DESI Legacy Imaging Surveys DR8

We extend the halo-based group finder developed by Yang et al. (2005c) to use data simultaneously with either photometric or spectroscopic redshifts. A mock galaxy redshift survey constructed from a high-resolution N-body simulation is used to evaluate the performance of this extended group finder. For galaxies with magnitude z ≤ 21 and redshift 0 < z ≤ 1.0 in the DESI legacy imaging surveys (the Legacy Surveys), our group finder successfully identifies more than 60% of the members in about 90% of halos with mass ≳10 12.5 h –1 M ⊙ . Detected groups with mass ≳10 12.0 h –1 M ⊙ have a purity (the fraction of true groups) greater than 90%. The halo mass assigned to each group has an uncertainty of about 0.2 dex at the high-mass end ≳10 13.5 h –1 M ⊙ and 0.45 dex at the low-mass end. Groups with more than 10 members have a redshift accuracy of ~0.008. We apply this group finder to the Legacy Surveys DR8 and find 6.4 million groups with at least three members. About 500,000 of these groups have at least 10 members. Furthermore, the resulting catalog containing 3D coordinates, richness, halo masses, and total group luminosities is made publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Throughput Large-Scale Targeted Proteomics Assays for Quantifying Pathway Proteins in Pseudomonas putida KT2440

Targeted proteomics is a mass spectrometry-based protein quantification technique with high sensitivity, accuracy, and reproducibility. As a key component in the multi-omics toolbox of systems biology, targeted liquid chromatography-selected reaction monitoring (LC-SRM) measurements are critical for enzyme and pathway identification and design in metabolic engineering. To fulfill the increasing need for analyzing large sample sets with faster turnaround time in systems biology, high-throughput LC-SRM is greatly needed. Even though nanoflow LC-SRM has better sensitivity, it lacks the speed offered by microflow LC-SRM. Recent advancements in mass spectrometry instrumentation significantly enhance the scan speed and sensitivity of LC-SRM, thereby creating opportunities for applying the high speed of microflow LC-SRM without losing peptide multiplexing power or sacrificing sensitivity. Here, we studied the performance of microflow LC-SRM relative to nanoflow LC-SRM by monitoring 339 peptides representing 132 enzymes in Pseudomonas putida KT2440 grown on various carbon sources. The results from the two LC-SRM platforms are highly correlated. In addition, the response curve study of 248 peptides demonstrates that microflow LC-SRM has comparable sensitivity for the majority of detected peptides and better mass spectrometry signal and chromatography stability than nanoflow LC-SRM.

59 BASIC BIOLOGICAL SCIENCES↗

Predicting images for the dynamics of stellar clusters ( π-DOC ): a deep learning framework to predict mass, distance, and age of globular clusters

ABSTRACT Dynamical mass estimates of simple systems such as globular clusters (GCs) still suffer from up to a factor of 2 uncertainty. This is primarily due to the oversimplifications of standard dynamical models that often neglect the effects of the long-term evolution of GCs. Here, we introduce a new approach to measure the dynamical properties of GCs, based on the combination of a deep-learning framework and the large amount of data from direct N-body simulations. Our algorithm, π-DOC (Predicting Images for the Dynamics Of stellar Clusters) is composed of two convolutional networks, trained to learn the non-trivial transformation between an observed GC luminosity map and its associated mass distribution, age, and distance. The training set is made of V-band luminosity and mass maps constructed as mock observations from N-body simulations. The tests on π-DOC demonstrate that we can predict the mass distribution with a mean error per pixel of 27 per cent, and the age and distance with an accuracy of 1.5 Gyr and 6 kpc, respectively. In turn, we recover the shape of the mass-to-light profile and its global value with a mean error of 12 per cent, which implies that we efficiently trace mass segregation. A preliminary comparison with observations indicates that our algorithm is able to predict the dynamical properties of GCs within the limits of the training set. These encouraging results demonstrate that our deep-learning framework and its forward modelling approach can offer a rapid and adaptable tool competitive with standard dynamical models.

Chardin, Jonathan↗

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory ↗

A case study on the use of carbon sticky tabs for microbeam uranium isotope measurement with an emphasis on understanding the influence of subtle variations in substrate composition

In this paper we integrate laser induced breakdown spectroscopy (LIBS), large geometry secondary ion mass spectrometry (LG-SIMS), laser ablation—multi collector—inductively coupled plasma—mass spectrometry (LA-MC-ICP-MS), and trace elemental compositions obtained by bulk digestion from a suite of commercially available carbon sticky tabs to determine if subtle variations in the tab’s composition can be tied to shifts in the observed uranium isotopic composition of the IRMM-2020 standard relative to its ‘true’ value. The results suggest that, although clear differences exist in the relative abundances of carbon and hydrogen across the various carbon sticky tabs examined, as well as differences in their trace elemental and total uranium concentrations, these differences do not appear to influence the LG-SIMS or LA-MC-ICP-MS uranium isotope ratio measurements, or the appearance of the uranium mass spectrum scans. Instead, the quality (i.e., precision and accuracy) of the LG-SIMS and LA-MC-ICP-MS results are directly proportional to the observed signal intensity at the time of analysis. For the LG-SIMS measurements, there does appear to be a direct correlation between 235U1H hydride formation rates and vacuum conditions within the instrument’s analytical chamber. Furthermore, none of the carbon sticky tabs examined by LG-SIMS displayed evidence of elevated background uranium content. While a preliminary correlation was observed between the uranium isotope background signal during LA-MC-ICP-MS and the total uranium concentrations determined by isotope dilution, none of the tabs displayed a high enough analytical background to affect the isotope ratio measurements.

Zirakparvar, Alex [ORNL] (ORCID:0000000337797730)↗

Weak boundary conditions for Lagrangian shock hydrodynamics: A high-order finite element implementation on curved boundaries

Here, we propose a new Nitsche-type approach for weak enforcement of normal velocity boundary conditions for a Lagrangian discretization of the compressible shock-hydrodynamics equations using high-order finite elements on curved boundaries. Specifically, the variational formulation is appropriately modified to enforce free-slip wall boundary conditions, without perturbing the structure of the function spaces used to represent the solution, with a considerable simplification with respect to traditional approaches. Total energy is conserved and the resulting mass matrices are constant in time. The robustness and accuracy of the proposed method are validated with an extensive set of tests involving nontrivial curved boundaries.

97 MATHEMATICS AND COMPUTING↗

The Electron Thermal Conductivity of Pu and Zr Substituted $\mathcal{γ}$-U

Uranium alloys are attractive recycled nuclear fuels because of their high thermal conductivity (𝑘) and fissile density. Limited experimental studies of the 𝑘 of U-Pu-Zr alloys in the range of 15 to 20 wt% Pu and 6 to 15 wt% Zr indicate that increasing the content of either Zr or Pu tends to lower 𝑘. However, which element has the greater effect on 𝑘, and the associated mechanisms, remains unclear. Here, in this study, the electron thermal conductivity (𝑘 𝑒 ) of U-Pu-Zr compositions are calculated using density functional theory. The electronic structure is evaluated to understand the effects of plutonium (Pu) and zirconium (Zr) substitution on the 𝑘 𝑒 of 𝛾-U. Alloys of up to 37.5 at. % Pu and 37.5 at. % Zr are examined. Two methods are applied to calculate 𝑘 𝑒 ; we find that the accuracy of each method depends on the electronic and mass similarities between the solute and solvent atoms. Specifically, when the solute atom is similar in electronic structure and mass, the more accurate method is that which employs the electron relaxation time of 𝛾-U, while if the elements are dissimilar, a mixed method that mixes several parameters associated with JNW_S⁢3033426825100132 from each element in the alloy is best. The introduction of all alloying elements decreases 𝑘 𝑒 ; however, in binary compounds, Pu and Zr have different effects. Pu flattens the electronic bands but compensates for this deleterious effect by increasing electron density near the Fermi level. Zr flattens the electronic bands more severely without adding electron density near the Fermi level. Therefore, Zr decreases 𝑘 𝑒 more than Pu in binary compounds. In ternary compounds, the difference between Pu and Zr is minimal due to the phononic change from the large mass change of Zr substitution, even at 12.5 at. %. Thus, we predict that higher loadings of Pu, and potentially other actinides, can be added to U-Pu-Zr compositions for faster recycling of spent fuel without sacrificing 𝑘. We also note that these 𝑘 𝑒 calculation methods can be applied to non-fuel alloys that require 𝑘 𝑒 predictions, such as cladding, heat exchanger, and structural materials.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗