Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Atmospheric-pressure ionization and fragmentation of molecules for structural elucidation

A solution-cathode glow discharge mass spectrometry (SCGD-MS) apparatus comprises a SCGD source and a mass spectrometer. The SCGD source may comprise conductive rods, a power source, and a capillary. A method for ionizing an analyte comprises flowing an electrically conductive liquid onto a conductive rod, applying an electric potential to a second conductive rod such that a plasma discharge forms between the first conductive rod and the electrically conductive liquid to produce ions, and separating the ions in a mass spectrometer. The analyte may be a polypeptide that may be contacted with trypsin. The analyte may be a solid, liquid, gas, chemical complex, or ion in solution. The method may comprise sequencing the polypeptide.

Shelley, Jacob T.↗

Volatile Organic Compounds in Bankhead National Forest (AMF3). August to September, 2025

The formation of atmospheric aerosols through the transformation of volatile organic compounds (VOCs) is a fundamental process in aerosol-climate interactions, as these particles serve as cloud condensation nuclei and ultimately influence Earth’s radiative balance. However, there remains a critical need to quantify the effects of multiple coexisting VOC precursors on aerosol formation beyond the limitations of laboratory-scale studies. This research aims to advance the mechanistic understanding of secondary organic aerosol formation in the southeastern United States by investigating interactions among coexisting VOC precursors observed at the third ARM Mobile Facility located in the Bankhead National Forest. The dataset was generated from the deployment of Oak Ridge National Laboratory’s PTR-TOF 6000 X2 Proton Transfer Reaction Time-of-Flight Mass Spectrometer (PTR-ToF-MS) for the real-time, continuous monitoring of VOCs from August 21 to September 15, 2025. To minimize sampling artifacts and compound losses, the PTR-ToF-MS inlet was connected to the cabin flow line by replacing the existing Tygon tubing with 1/2-inch outer diameter perfluoroalkoxy (PFA) tubing. The instrument operated on an hourly measurement cycle consisting of 8 minutes of zero-air measurements followed by 52 minutes of ambient air sampling, with a temporal resolution of 10 seconds. The dataset includes concentrations, reported in ppb, of methanol, acetone, acetonitrile, isoprene, methyl vinyl ketone and methacrolein (MVK + MACR), monoterpenes, benzene, toluene, and catechol.

Atmospheric concentration of volatile organic comp↗

Characterizing Hazardous Gases from NMC811 Materials and Coin Cells with TGA and Tube-Furnace FTIR-MS Evolved-Gas-Analysis

Abuse testing is useful for informing the risks of different battery chemistries but has been limited to larger formats. This paper conducted thermal abuse tests at the smaller coin cell level to determine its relevance in specifying vent gas flammability and toxicity. A nitrogen purge carried the evolved gases into a parallel Fourier-transform infrared spectrometer (FTIR) and a mass spectrometer (MS) downstream of the tube furnace. The experimental system was validated by comparing evolved gas data for single components between the tube furnace system and a thermogravimetric analysis (TGA) instrument. Multiple samples were tested during validation, including CaCO3, electrolyte, delithiated NMC 811 cathode, and lithiated graphite anode. Temperature-resolved gas evolution of HF, CO2, CO, H2, and hydrocarbons from isolated components helped to characterize the emission sources. A previously unreported H2 generation mechanism was found. It was shown that the reduced NMC cathode acts as a catalyst to crack polypropylene-decomposed hydrocarbons into H2 at around 450 degrees C. It was also shown, while studying LiPF6 thermal decomposition, that using the tube furnace with a coin cell casing as the sample holder has some advantages for evolved-gas analysis of environmentally sensitive samples relative to testing in TGA instruments. After validation with single components, a fully charged NMC 811 coin cell was failed in the tube furnace. The measured evolved gases were found to be a combination of the species measured from the single component tests. H2 formation related to the reduced cathode was found to have greater abundance than H2 formed from the anode. Hydrogen fluoride emission factors and diethyl carbonate conversion emission factors assist in understanding the gaseous hazards for larger format cells.

25 ENERGY STORAGE↗

The Uranium-Containing and Thorium-Containing Anions Studied by Photoelectron Spectroscopy

An in-depth knowledge of actinide chemistry is fundamental to many aspects of nuclear science and technology, including the synthesis and processing of materials and the remediation of waste disposal sites. Among the actinides, the chemical bonding behaviors of actinium and thorium resemble those of the transition metals; the 5f-electrons of protactinium, uranium, neptunium, and plutonium often play important roles in their bonding; and among the still heavier elements, their bonding tends to mimic the lanthanide elements in terms of electron shielding and their f-electron contributions. Bonding that involves 5f-electrons, however, is especially important, in part because of the significance of uranium and plutonium, but also because these elements are among the few where f-electron participation in bonding is relatively common. This work focused on studying uranium-containing and thorium-containing anions in the gas phase using negative ion photoelectron spectroscopy. Since this technique directly probed valence electrons, it was uniquely positioned to address open questions regarding molecular bonding and electron configurations. A particularly important issue concerned how bonding in actinide-containing molecules was affected by modifications to their actinide atoms’ environment, i.e., due to their interaction with ligands. A closely related question was how actinide atoms’ suborbitals were qualitatively reordered and their energies quantitatively shifted as a result of their ligated environments. These were especially relevant issues in regard to uranium due to it having multiple possible oxidation states (OS) and the potential for 5f electron participation in bonding. The effects of ligands on oxidation states and 5f-orbital energies in uranium bonding was expected to be pronounced. Both ligands and excess electrons were seen as probes of actinide atoms within actinide-containing molecules. Our strategy for advancing knowledge of chemical bonding in the actinide-containing species utilized the synergy between experiments and theory, where in some cases experimental results validated theory and where in others computational results assisted in interpreting experiments. Calculations on actinide systems are terrifically challenging due to large spin-orbit interactions, relativistic effects, and just the sheer number of electrons involved. Even in the simplest species, e.g., U and U2, the most sophisticated, modern calculations carried out by the most experienced theorists often only approximate experimentally-measured values, such as electron affinities. For theory to provide confident predictions that can be used to solve real problems it needed an iterative and ultimately corrective mechanism by which its methods can develop further. Experiments can be used to identify when theory has failed; whereupon the subsequent process of using the experiment-theory interplay can be used to find the cause of the failure. Upon fixing it in one case, different test species can be proposed and studied by the experiment-theory combination to determine whether the problem has been corrected. Thus, experiments not only measure the values of molecular properties, they also provide navigational 3 beacons that keep computations off the reefs in an otherwise dark sea with few reference points. Experimental measurements in the actinide field are not only important, they are in actuality essential to computational progress. While it was not always possible to compare the theoreticallydetermined quantity of interest directly with the same experimentally-measured observable, it was usually possible to compare consequential properties that are both calculable and measurable. In the work completed here electron affinities and electronic state spacings were often sensitive consequential parameters. Reasonable agreement between measured and computational values signaled that a calculation that was very likely to be on-track. We had established collaborative relationships with five computational groups, all of which have expertise in computational actinide chemistry. Their PI’s are L. Cheng, D. Dixon, L. Gagliardi, K. Peterson, and B. Vlaisavljevich. Our close interaction with our theory partners led to us suggesting systems to them and them to us. This reciprocal interaction between our experimental and their computational results was among the most important strengths of this work and was a thread woven throughout. Even though anion photoelectron spectroscopic studies are conducted on anions, much of the information that they provide, pertains to the electronic structure of the neutral counterparts of those anions; among these are electron affinities and electronically excited state spacings. Our experimental tools included several specialized ion sources for forming the anionic species of interest, a mass spectrometer for identifying and mass-selecting them, and an anion photoelectron spectrometer for determining their electron affinities (EA) and characterizing the electronic states of the selected anions’ neutral counterparts. Anion photoelectron spectroscopy is conducted by crossing a mass-selected beam of anions with a fixed-frequency laser beam and energy-analyzing the resultant photodetached electrons. The photodetachment process is governed by the energyconserving relationship: hν = EBE + EKE, where hν is the photon’s energy, EBE is the electron binding (photodetachment transition) energy, and EKE is the electron’s kinetic energy. In our apparatus mass-selection is accomplished via time-of-flight mass spectrometry (TOF-MS), electron energy analysis is achieved with either a magnetic bottle or by velocity mapped imaging. Photodetachment of electrons from anions is implemented via either Nd:YAG or excimer lasers. The photodetachment transition energy, i.e., the EBE, between the ground vibrational and electronic state of an anion and the ground vibrational and electronic state of that anion’s neutral counterpart is the adiabatic electron affinity (EA) of that neutral molecule. Likewise, photodetachment transitions between the ground vibrational and electronic state of an anion and the various electronically-excited states of that anion’s corresponding neutral map the electronic spectrum of that neutral species, i.e., the spectral spacings in the photoelectron spectrum are a mirror image of the neutral’s electronic spectrum. It was, of course, crucial to be able to form the anionic species of interest. There, we had a particularly broad field of anion sources from which to choose. These included several variants of pulsed laser vaporization (LV), laser photoemission, infrared desorption plus photoemission, pulsed arc discharge (PACIS), electrospray ionization (ESI), and Rydberg electron transfer (RET). Each of these anion sources were readily combined with, i.e., connected to, the anion photoelectron spectroscopic portion of our apparatus as described above. Among the sources that utilize lasers, visible light for LV sources as well as IR for desorption sources are provided by Nd:YAG lasers. Ultraviolet photons are provided by both Nd:YAG and excimer lasers, whereas the excitation wavelengths for RET experiments come from two Nd:YAG-pumped dye lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase-Imaging Ion-Cyclotron-Resonance mass spectrometry with the Canadian Penning Trap at CARIBU

The Canadian Penning Trap mass spectrometer (CPT) has conducted precision mass measurements of neutron-rich nuclides from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) of the Argonne Tandem Linac Accelerator System (ATLAS) facility at Argonne National Laboratory using the Phase-Imaging Ion-Cyclotron-Resonance (PI-ICR) technique for over half a decade. Here, in this study, we discuss the CPT system, and methods to improve accuracy and precision in mass measurement using PI-ICR including some optimization techniques and recently studied systematic effects.

Penning trap mass spectrometry↗

PPI DataHub Project Data Package: S. elongatus PCC 7942 Circadian Control Bioproduction Metabolomics (PB-DP5)

The purpose of this experiment was to evaluate how circadian clock regulation impacts carbon partitioning between storage, growth, and product synthesis in Synechococcus elongatus PCC 7942 in providing insights to strategies for enhanced bioproduction. Culture samples were collected at 0, 0.5, 1, 2, 4, 6, and 8 hours for extracellular sucrose analysis. Circadian metabolomics data was acquired using a Agilent single quadrupole gas chromatography-mass spectrometer and processed using Agilent Mass Hunter for targeted sucrose quantification. Metabolomic analysis of PCC 7942 light-dark cycle cultures transitioned to constant light revealed distinct temporal patterns in sucrose production. Processed metabolomic datasets are openly accessible from the PNNL DataHub project dataset download page and contain secondary processed GC-MS results files and supporting metadata materials linked to relevant source code information supporting data transparency and reuse.

59 BASIC BIOLOGICAL SCIENCES↗

Mass measurements of neutron-rich indium isotopes for r -process studies

A new series of neutron-rich indium mass measurements is reported from the TITAN multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS). These mass measurements cover 125-134 In (N = 76–85) and include ground states as well as isomeric states. The masses of nuclei in this region are known to be of great importance for accurately modeling r-process nucleosynthesis, and the significance of the reported neutron-rich indium masses is discussed in this context. Results are compared with earlier experimental data where available as well as theoretical mass models. The measurements reported here include the first mass measurements of 133,134 In, as well as the first direct mass measurement of 132 In. The masses of 125-131 In ground states and several isomers were previously measured to higher precision by Penning trap mass spectrometry, which also resolved some low-lying isomers that could not be resolved in this work. The earlier Penning trap measurements serve as excellent cross-checks for the MR-TOF-MS measurements, and in some cases the MR-TOF-MS measurements improve the literature uncertainties of higher-lying isomer masses and excitation energies. Finally, a new isomeric state for 128 In, recently reported for the first time by the JYFLTRAP group, is also confirmed by the TITAN MR-TOF-MS, with a measured excitation energy of 1813(17) keV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HPLC-Parallel accelerator and molecular mass spectrometry analysis of 14 C-labeled amino acids

Accelerator mass spectrometry (AMS) is the method of choice for quantitation of low amounts of 14 C-labeled biomolecules. Despite exquisite sensitivity, an important limitation of AMS is its inability to provide structural information about the analyte. This limitation is not critical when the labeled compounds are well-characterized prior to AMS analysis. However, analyte identity is important in other experiments where, for example, a compound is metabolized and the structures of its metabolites are not known. We previously described a moving wire interface that enables direct AMS measurement of liquid sample in the form of discrete drops or HPLC eluent without the need for individual fraction collection, termed liquid sample-AMS (LS-AMS). Here, we now report the coupling of LS-AMS with a molecular mass spectrometer, providing parallel accelerator and molecular mass spectrometry (PAMMS) detection of analytes separated by liquid chromatography. The repeatability of the method was examined by performing repeated injections of 14 C-labeled tryptophan, and relative standard deviations of the 14 C peak areas were ≤10.57% after applying a normalization factor based on a standard. Five 14 C-labeled amino acids were separated and detected to provide simultaneous quantitative AMS and structural MS data, and AMS results were compared with solid sample-AMS (SS-AMS) data using Bland-Altman plots. To demonstrate the utility of the workflow, yeast cells were grown in a medium with 14 C-labeled tryptophan. The cell extracts were analyzed by PAMMS, and 14 C was detected in tryptophan and its metabolite kynurenine.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Exploring the onset of collectivity approaching 𝑁=40 with masses of manganese isotopes

Isotopes in the region of the nuclear chart below 68 Ni have been the subject of intense experimental and theoretical effort due to the potential onset of a new “island of inversion” when crossing the harmonic oscillator subshell closure at 𝑁=40. Here, we have measured the masses of 64−68 Mn using TITAN's multiple-reflection time-of-flight mass spectrometer, resulting in the first precision mass measurements of 67 Mn and 68 Mn. These results are compared to ab initio calculations and modern shell model calculations and show an increase in collectivity approaching 𝑁=40.

binding energy & masses↗

High resolution identification and quantification of diffuse deep groundwater discharge in mountain rivers using continuous boat-mounted helium measurements

Discharge of deeply sourced groundwater to streams is difficult to locate and quantify, particularly where both discrete and diffuse discharge points exist, but diffuse discharge is one of the primary controls on solute budgets in mountainous watersheds. The noble gas helium is a unique identifier of deep groundwater discharge because groundwater with long residence times is commonly enriched in helium. In this study, a portable mass spectrometer was used to measure longitudinal variation in dissolved helium concentrations in two mountainous rivers at high spatial resolution not feasible with traditional sampling techniques. Helium profiles were then simulated using a mass-balance model to quantify longitudinal variation in groundwater discharge to the receiving rivers. Results indicate helium concentrations were enriched by multiple orders of magnitude above atmospheric equilibrium in both rivers and that this persisted for up to 18 km below observed pulse inputs in the Colorado River. Helium mass-balance models match observed longitudinal patterns with the exception of sharp initial increases in helium observed in the rivers. Increased longitudinal groundwater discharge rates correspond to mapped geologic structures in both watersheds that likely transport deep geothermal water. Models show variable sensitivity to spatial assignment of input variables representing the groundwater source, illustrating the importance of collecting data from discrete groundwater discharges where possible. The methodology shows promise for field experiments designed to assess air–water exchange rates and to quantify total groundwater discharge from a combination of discrete and diffuse sources.

Deep groundwater↗

Enhancing the mass resolving power of FRIB’s proposed high-voltage MR-ToF mass separator and spectrometer: Addressing non-ideal conditions

Multi-reflection time-of-flight mass separators and spectrometers (MR-ToF MSs) are indispensable tools at radioactive ion beam (RIB) facilities. These electrostatic ion beam traps act as highly selective mass separators and high-precision mass spectrometers for rare and exotic nuclei. When well-tuned and designed to minimize higher-order flight-time aberrations, state-of-the-art MR-ToF MSs approach, and slightly exceed, mass resolving powers of m/Δm = 10 6 . Achieving m/Δm ≥ 3 ⋅ 10 6 would provide the ability to resolve > 90 % of all known isomeric states with half-lives above 10 ms. However, the ability to mass separate in all practical setups is limited by non-ideal conditions which place such resolving powers out of reach. Here, to this end, we present a simulated analysis of these conditions in the newly proposed high-voltage MR-ToF MS for the Facility for Rare Isotope Beams (FRIB). It is expected to store ions at 30 keV beam energy and increase ion throughput by two orders of magnitude compared to current devices. Existing efforts to mitigate the effects of non-ideal conditions employed for current MR-ToF devices storing ions at < 3 keV beam energy will already enable mass resolving powers approaching 10 6 for FRIB’s high-voltage MR-ToF device. Simulations of newly proposed mitigation strategies show that even mass resolving powers approaching 10 7 might become feasible.

Electrostatic ion beam traps↗

Browne_EtOHCIMS_SGP_2021

Mixing ratios of ammonia and pyridine. These were measured on a chemical ionization time-of-flight mass spectrometer with ethanol reagent ion at the ARM Southern Great Plains site in October 2021.

54 ENVIRONMENTAL SCIENCES↗

Application of a Chemical Index to Aerosol Mass Spectrometry: Delta Plots and Functional Group Distributions

A better understanding of the chemical properties of organic aerosol (OA) particles will improve our ability to characterize their sources and predict their lifetime. The high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA in real time using thermal vaporization followed by electron ionization (EI). EI creates fragment ions that can be assigned to functional groups using delta analysis, a method of classifying mass spectra according to the presence of different chemically related ion series. In this study, we demonstrate the application of delta analysis to characterize molecular structures using a new visualization method. We also use delta analysis to quantify the functional group distribution with an average absolute error of ∼5–6% for individual standard molecules, comparable to the error observed for OA mixtures from biomass and coal combustion fit with Fourier transform infrared spectroscopy. Finally, we apply delta functional group analysis to AMS positive matrix factorization (PMF) factors across seven different field campaigns and find a similar composition across the more oxidized factors with about 55% acid and 26% alcohol groups. The analysis method described here can be applied to any HR-ToF-AMS data set to provide quantitative relative functional group distributions for OA mixtures.

aerosol↗

Direct Mass Measurements to Inform the Behavior of 128m $\mathrm{Sb}$ in Nucleosynthetic Environments

Nuclear isomer effects are pivotal in understanding nuclear astrophysics, particularly in the rapid neutron-capture process where the population of metastable isomers can alter the radioactive decay paths of nuclei produced during astrophysical events. The β-decaying isomer 128m Sb was identified as potentially impactful since the β-decay pathway along the A = 128 isobar funnels into this state bypassing the ground state. Here we report the first direct mass measurements of the 128 Sb isomer and ground state using the Canadian Penning Trap mass spectrometer at Argonne National Laboratory. We find mass excesses of -84564.8(25) keV and -84608.8(21) keV, respectively, resulting in an excitation energy for the isomer of 43.9(33) keV. These results provide the first key nuclear data input for understanding the role of 128m Sb in nucleosynthesis, and we show that it will influence the flow of the rapid neutron-capture process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Balancing Trade-Offs Imposed by Growth Media and Mass Spectrometry for Bacterial Exometabolomics

The bacterial exometabolome consists of a vast array of specialized metabolites, many of which are only produced in response to specific environmental stimuli. For this reason, it is desirable to control the extracellular environment with a defined growth medium composed of pure ingredients. However, complex (undefined) media are expected to support the robust growth of a greater variety of microorganisms than defined media. Here, we investigate the trade-offs inherent to a range of complex and defined solid media for the growth of soil microorganisms, production of specialized metabolites, and detection of these compounds using direct infusion mass spectrometry. We find that complex media support growth of more soil microorganisms, as well as allowing for the detection of more previously discovered natural products as a fraction of total m/z features detected in each sample. However, the use of complex media often caused mass spectrometer injection failures and poor-quality mass spectra, which in some cases resulted in over a quarter of samples being removed from analysis. Defined media, while more limiting in growth, generated higher quality spectra and yielded more m/z features after background subtraction. These results inform future exometabolomic experiments requiring a medium that supports the robust growth of many soil microorganisms.

59 BASIC BIOLOGICAL SCIENCES↗

Time-resolved chemical studies via time-of-flight secondary ion mass spectrometry

A method of performing time-of-flight secondary ion mass spectrometry on a sample includes the step of directing a beam of primary ions to the sample, and stimulating the migration of ions within the sample while the beam of primary ions is directed at the sample. The stimulation of the ions is cycled between a stimulation state and a lower stimulation state. Secondary ions emitted from the sample by the beam of primary ions are collected in a time-of-flight mass spectrometer. Time-of-flight secondary ion mass spectrometry is then performed on the secondary ions. A system for performing time-of-flight secondary ion mass spectrometry on a sample is also disclosed.

Ievlev, Anton V.↗

CoURAGE Stationary ELF PTR-MS Measurements at the Mt. Airy Site

Gas phase measurements of volatile organic compounds (VOC) taken at the DOE ARM S2 site for the CoURAGE campaign using a Vocus ELF PTR-ToF (Tofwerk) mass spectrometer. Measurements of several VOC's (e.g., acetaldehyde, acetone, benzene, etc.) were obtained at 1-minute resolution from 4/08 to 5/19.

acetaldehyde_concentration↗

Positive and Negative Ion CIMS Measurements, SGP, May-June 2024

The negative ion measurements were taken using two LTOF-CIMS with two different nitrate inlets. The data labeled Aerodyne_Inlet used an Aerodyne nitrate inlet. Data labeled PCC used a custom transverse inlet. The positive ion measurements were taken using one LTOF-CIMS with hydronium as an ionization reagent using a custom transverse inlet with an inlet voltage difference of 700 V. See https://doi.org/10.1021/acs.jpca.2c01672 for more information. Peaks were autofit using tofware. Positive ion data is published in the form of peak signal/reagent signal. Data files of peak signal/reagent signal for the two mass spectrometers for the negative ion measurements are separate. Concentrations of H2SO4 are combined into one file. When measurements were overlapping, measurements from the Aerodyne nitrate inlet were used.

54 ENVIRONMENTAL SCIENCES↗