Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Impact on aggregate/matrix bonding when a refractory contains zinc aluminate instead of spinel and magnesia‐chrome

The high hot strength of MgO–Cr 2 O 3 refractory is often ascribed to its intimate aggregate/matrix bonding. For a fundamental comparison with it, ~2 mm aggregates of MgO and Al 2 O 3 were separately embedded in ZnAl 2 O 4 and MgAl 2 O 4 matrices, sintered at 1600°C, and examined. It was found that similarity of thermal expansion coefficient (TEC) between the aggregate and the matrix is critical to achieve good bonding and this is more important than the extent of interdiffusion. The TEC mismatch of ≥ 5.7 × 10 -6 K -1 caused significant undesirable debonding in MgO aggregate/MgAl 2 O 4 matrix sample and MgO/ZnAl 2 O 4 despite >736 μm Zn 2+ diffusion depth in the latter. Direct bonding, as inferred from a thicker interfacial reaction layer and a greater shift of the aggregate/matrix interface before and after firing, was better in MgAl 2 O 4 /ZnAl 2 O 4 combination, followed by tabular Al 2 O 3 /ZnAl 2 O 4 and Al 2 O 3 /MgAl 2 O 4 . Powder X-ray diffraction indicated that the volatilization of ZnAl 2 O 4 at 1600°C in air was negligible compared to MgO–Cr 2 O 3 .

36 MATERIALS SCIENCE↗

Analysis of useful ion yield for Si in GaN by secondary ion mass spectrometry

The optimum detection levels that can be achieved by a secondary ion mass spectrometer are dependent on how efficiently a particular species of interest can be ionized and detected. One can determine in advance whether the analysis of a particular ion in the sample is possible, if the useful ion yield is known. The useful ion yield depends on the element, instrument transmission, the analytical conditions, the sample matrix, etc. The value of the useful ion yield for a species can diverge from one instrument type to another due to its different transmission and ionization probabilities. However, the same tendencies in the results may be expected for all types of instruments. In this paper, the authors present a quantitative secondary ion mass spectrometry analysis of the useful ion yield for the silicon dopant species in a gallium nitride matrix grown by metal organic chemical vapor deposition. Positively ionized cesium was used as the primary ion beam, and its energy was varied in the range from 0.5 to 5 kV. A quadrupole mass analyzer was utilized to collect secondary ion species of interest. The analysis results can be used to determine the primary beam energies for optimal Si sensitivity.

Senevirathna, M. K. Indika (ORCID:0000000243575029↗

Influence of photon beam energy on the dose enhancement factor caused by gold and silver nanoparticles: An experimental approach

Purpose: Noble metal nanoparticles have found several medical applications in the areas of radiation detection; x-ray contrast agents and cancer radiation therapy. Based on computational methods, many papers have reported the nanoparticle effect on the dose deposition in the surrounding medium. Here the authors report experimental results on how silver and gold nanoparticles affect the dose deposition in alanine dosimeters containing several concentrations of silver and gold nanoparticles, for five different beam energies, using electron spin resonance spectroscopy (ESR). Methods: The authors produced alanine dosimeters containing several mass percentage of silver and gold nanoparticles. Nanoparticle sizes were measured by dynamic light scattering and by transmission electron microscopy. The authors determined the dose enhancement factor (DEF) theoretically, using a widely accepted method, and experimentally, using ESR spectroscopy. Results: The DEF is governed by nanoparticle concentration, size, and position in the alanine matrix. Samples containing gold nanoparticles afford a DEF higher than 1.0, because gold nanoparticle size is homogeneous for all gold concentrations utilized. For samples containing silver particles, the silver mass percentage governs the nanoparticles size, which, in turns, modifies nanoparticle position in the alanine dosimeters. In this sense, DEF decreases for dosimeters containing large and segregated particles. The influence of nanoparticle size-position is more noticeable for dosimeters irradiated with higher beam energies, and dosimeters containing large and segregated particles become less sensitive than pure alanine (DEF < 1). Conclusions: ESR dosimetry gives the DEF in a medium containing metal nanoparticles, although particle concentration, size, and position are closely related in the system. Because this is also the case as in many real systems of materials containing inorganic nanoparticles, ESR is a valuable tool for investigating DEF. Moreover, these results alert to the importance of controlling the size-position of nanoparticles to enhance DEF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

Rapid monitoring of fermentations: a feasibility study on biological 2,3-butanediol production

2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be produced by the fermentation of sugars using an engineered strain of Zymomonas mobilis . These fermentations require continuous monitoring and modification of fermentation conditions to maximize 2,3-BDO yields and minimize the production of the undesired coproducts glycerol and acetoin. Because of the time required for sampling and off-line chromatographic measurement of fermentation samples, the ability of fermentation scientists to modify fermentation conditions in a timely manner is limited. The goal of this study was to test if near-infrared spectroscopy (NIRS) along with multivariate statistics could reduce the time needed for this analysis and enable real-time monitoring and control of the fermentation. In this work we developed partial least squares (PLS) calibration models to predict the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol in fermentations via NIRS using two different spectrometers and two different spectroscopy modalities. We first evaluated the feasibility of rapid NIRS monitoring through experiments where we measured the signals from each analyte of interest and built NIRS-based PLS models using spectra from synthetic samples containing uncorrelated concentrations of these analytes. All analytes showed unique spectral signatures, and this initial modeling showed that all analytes could be detected simultaneously. We then began work with samples from laboratory fermentation experiments and tested the feasibility of regression model development across two spectral collection modalities (at-line and on-line) and two instruments: a laboratory-grade instrument and a low-cost instrument with a more limited spectral range. All modalities showed promise in the ability to monitor Z. mobilis fermentations of glucose and xylose to 2,3-BDO. The low-cost instrument displayed a lower signal-to-noise ratio than the laboratory-grade instrument, which led to comparatively lower performance overall, but still provided sufficient accuracy to monitor fermentation trends. While the ease of use of on-line monitoring systems was favored as compared to at-line systems due to the lack of sampling required and potential for automated process control, we observed some decrease in performance due to the additional complexity of the sample matrix. We have demonstrated that NIRS combined with multivariate analysis can be used for at-line and on-line monitoring of the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol during Z. mobilis fermentations. The decrease in signal-to-noise ratio when using a low-cost spectrometer led to greater prediction error than the laboratory-grade spectrometer for at-line monitoring. The on-line monitoring modality showed great promise for real time process control via NIRS.

09 BIOMASS FUELS↗

Portable Diagnostics and Rapid Germination

In the Bioenergy and Defense Department of Sandia National Laboratories, characterization of the BaDx (Bacillus anthracis diagnostic cartridge) was performed and rapid germination chemistry was investigated. BaDx was tested with complex sample matrixes inoculated with Bacillus anthracis, and the trials proved that BaDx will detect Bacillus anthracis in a variety of the medium, such as dirt, serum, blood, milk, and horse fluids. The dimensions of the device were altered to accommodate an E. coli or Listeria lateral flow immunoassay, and using a laser printer, BaDx devices were manufactured to identify E. coli and Listeria. Initial testing with E. coli versions of BaDx indicate that the device will be viable as a portable diagnostic cartridge. The device would be more effective with faster bacteria germination; hence studies were performed the use of rapid germination chemistry. Trials with calcium dipicolinic acid displayed increased cell germination, as shown by control studies using a microplate reader. Upon lyophilization the rapid germination chemistry failed to change growth patterns, indicating that the calcium dipicolinic acid was not solubilized under the conditions tested. Although incompatible with the portable diagnostic device, the experiments proved that the rapid germination chemistry was effective in increasing cell germination.

09 BIOMASS FUELS↗

Radiation History of Fission Gamma-Ray Spectra Relevant to Post-Detonation Debris Analysis

Quantifying the fissile content within trace amounts of nuclear material is of significant importance to safeguards and nuclear forensics communities. Traditionally, measurement methods have relied on destructive analysis (DA) measurements or passive detection of gamma/neutron signatures through nondestructive assay (NDA). These methods are highly accurate and employed globally as both a nuclear forensics capability and a material accountability measurement. However, common DA techniques rely on sample dissolution, a time-consuming process which can be particularly difficult for certain sample matrices, such as melt-glass formed from nuclear fallout. Likewise, trace quantities of nuclear materials prove difficult to measure using passive NDA techniques due to relatively low emission rates and potential interference from activated materials within the sample matrix.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LLNL Evaluation of 44th OPCW Environmental Proficiency Test

The goal of the test was to analyze all samples for the presence of any Scheduled Chemicals and/or their precursors/degradation/reaction products and chemicals listed in the list of “Additional Non-Scheduled Reportable Chemicals”. According to the test scenario, the samples were collected from a facility described as an industrial research laboratory for developing new chemical compounds. Each participating laboratory received a set of three aqueous samples (described as “Decon Waste”) and a set of three soil samples (described as collected in an area of suspected chemical contamination, near a chemical storage facility). Each set of samples contained one “test sample”, one “control sample”, and one “blank sample” without indication of their identities. The test sample contained an unknown number of spiking chemicals, each present at a concentration of 1 ppm or greater. The control sample contained an unknown number of spiking chemicals, each present at a concentration of 5 ppm or greater. The blank sample contained no chemicals relevant to the aim of the test. However, for this test, the blank samples did contain irrelevant chemicals in addition to the sample matrix.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

From Fossil Fuels to Green Mines: Understanding Hydrogen-Shale Interactions for Secure Underground Storage

Hydrogen-powered mining trucks are rapidly gaining traction as a key driver of decarbonization in the mining industry. This surge necessitates a decisive shift towards renewable energy sources, primarily for hydrogen production. However, the inherent intermittency of renewables poses a challenge for continuous operations, demanding efficient storage solutions for hydrogen fuel. Hydrogen, derived from renewables, requires large-scale storage, with underground hydrogen storage (UHS) in depleted oil and gas reservoirs projected to provide this capacity. An impermeable seal (caprock) overlying depleted reservoirs is crucial for preventing leakage and ensuring secure storage. Shale, a potential caprock, has been recognized for its effectiveness in containing natural gas for geological time-periods. This study investigates the impact of hydrogen exposure on the matrix permeability of Marcellus shale, a key factor influencing its sealing capacity. A novel time-resolved approach was employed, measuring matrix permeability after each exposure to understand the dynamic interactions between hydrogen and the shale matrix. Samples were exposed to hydrogen in pressure reactions at realistic reservoir conditions at varying time durations. Preliminary results reveal an initial increase in permeability, while subsequent exposures show a decrease, indicating potential microstructural changes.

08 HYDROGEN↗

INFRARED AND ULTRAVIOLET SPECTRA OF METHANE DILUTED IN SOLID NITROGEN AND IRRADIATED WITH ELECTRONS DURING DEPOSITION AT VARIOUS TEMPERATURES

We recorded the infrared and ultraviolet absorption spectra of CH{sub 4}:N{sub 2} matrix samples that underwent electron bombardment during deposition in the temperature range of 10–44 K. In contrast to a previous experiment on the IR spectroscopy of electron-bombarded icy samples, methyl and azide radicals became the main products upon electron bombardment during deposition; furthermore, reduced production of nitrile species was observed for deposition at 10 and 20 K. On the other hand, for deposition above 33 K, the observed bands of the radical species (such as methyl and azide) decreased, and bands of large nitriles appeared. This observation may suggest that radical species easily diffuse and recombine to form more complex molecules in solid nitrogen at higher temperatures. Further measurements of similar samples at 10–33 K in the UV region revealed the intense band of azide radicals at 272.5 nm and weak, broad, overlapping features of methyl and azide radicals in the 225–197 nm region. For deposition at 44 K, only a broad feature centered at 219.4 nm was observed, and the possible carriers of nitrile species were proposed based on the corresponding IR spectrum and theoretical predictions of excitation energy. This band is similar to the observed absorption feature of Pluto’s surface recorded by the Hubble telescope in terms of both band position and bandwidth. Our findings therefore further support the suggestion that complex nitrile species may exist on the surface of Pluto.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Consortium studies of matrix of light gray breccia 73215

A description is presented of the preliminary results of interdisciplinary studies of matrix samples. The significance of the 73215 studies is considered and the relationship of 73215 to other Apollo 17 highland breccias is discussed. According to a tentative hypothesis 73215 is an aggregate of fragments plus melt generated in a very large impact, possibly the Serenitatis basin-forming event. If this is correct, studies of this sample will make it possible to date the Serenitatis event and will provide an insight into the breccia-forming processes associated with such events. Studies of the clasts in the breccia will provide an opportunity to formulate a partial characterization of the preimpact source terrain. An investigation of the deep lunar crust might perhaps also be possible.

James, O. B.↗

Matrix material in type 3 chondrites - Occurrence, heterogeneity and relationship with chondrules

Variations between mean matrix compositions of individual type 3 ordinary chondrites are nearly fivefold, and partly reflect systematic differences between H, L, and LL matrices. Such variations are probably the result of a nebular separation of feldspathic material and ferromagnesian silicates. While compositions of chondrules and their matrix rims are normally unrelated, rim compositions are correlated with those of matrix lumps inside chondrules. Matrix lumps are as heterogeneous as chondrules, but mean chondrule and matrix compositions differ. Since bulk compositions of matrix lumps and rims have probably not changed significantly since their formation, the present matrix samples cannot represent typical chondrule precursor materials.

Scott, E. R. D.↗

SMI adaptive antenna arrays for weak interfering signals

The performance of adaptive antenna arrays is studied when a sample matrix inversion (SMI) algorithm is used to control array weights. It is shown that conventional SMI adaptive antennas, like other adaptive antennas, are unable to suppress weak interfering signals (below thermal noise) encountered in broadcasting satellite communication systems. To overcome this problem, the SMI algorithm is modified. In the modified algorithm, the covariance matrix is modified such that the effect of thermal noise on the weights of the adaptive array is reduced. Thus, the weights are dictated by relatively weak coherent signals. It is shown that the modified algorithm provides the desired interference protection. The use of defocused feeds as auxiliary elements of an SMI adaptive array is also discussed.

Gupta, I. J.↗

SMI adaptive antenna arrays for weak interfering signals

The performance of adaptive antenna arrays in the presence of weak interfering signals (below thermal noise) is studied. It is shown that a conventional adaptive antenna array sample matrix inversion (SMI) algorithm is unable to suppress such interfering signals. To overcome this problem, the SMI algorithm is modified. In the modified algorithm, the covariance matrix is redefined such that the effect of thermal noise on the weights of adaptive arrays is reduced. Thus, the weights are dictated by relatively weak signals. It is shown that the modified algorithm provides the desired interference protection.

Gupta, Inder J.↗

A microstructural lattice model for strain oriented problems: A combined Monte Carlo finite element technique

A specialized, microstructural lattice model, termed MCFET for combined Monte Carlo Finite Element Technique, was developed which simulates microstructural evolution in material systems where modulated phases occur and the directionality of the modulation is influenced by internal and external stresses. In this approach, the microstructure is discretized onto a fine lattice. Each element in the lattice is labelled in accordance with its microstructural identity. Diffusion of material at elevated temperatures is simulated by allowing exchanges of neighboring elements if the exchange lowers the total energy of the system. A Monte Carlo approach is used to select the exchange site while the change in energy associated with stress fields is computed using a finite element technique. The MCFET analysis was validated by comparing this approach with a closed form, analytical method for stress assisted, shape changes of a single particle in an infinite matrix. Sample MCFET analytical for multiparticle problems were also run and in general the resulting microstructural changes associated with the application of an external stress are similar to that observed in Ni-Al-Cr alloys at elevated temperature.

Gayda, J.↗

Analysis of modified SMI method for adaptive array weight control

An adaptive array is applied to the problem of receiving a desired signal in the presence of weak interference signals which need to be suppressed. A modification, suggested by Gupta, of the sample matrix inversion (SMI) algorithm controls the array weights. In the modified SMI algorithm, interference suppression is increased by subtracting a fraction F of the noise power from the diagonal elements of the estimated covariance matrix. Given the true covariance matrix and the desired signal direction, the modified algorithm is shown to maximize a well-defined, intuitive output power ratio criterion. Expressions are derived for the expected value and variance of the array weights and output powers as a function of the fraction F and the number of snapshots used in the covariance matrix estimate. These expressions are compared with computer simulation and good agreement is found. A trade-off is found to exist between the desired level of interference suppression and the number of snapshots required in order to achieve that level with some certainty. The removal of noise eigenvectors from the covariance matrix inverse is also discussed with respect to this application. Finally, the type and severity of errors which occur in the covariance matrix estimate are characterized through simulation.

Dilsavor, R. L.↗

Analysis of Modified SMI Method for Adaptive Array Weight Control

An adaptive array is used to receive a desired signal in the presence of weak interference signals which need to be suppressed. A modified sample matrix inversion (SMI) algorithm controls the array weights. The modification leads to increased interference suppression by subtracting a fraction of the noise power from the diagonal elements of the covariance matrix. The modified algorithm maximizes an intuitive power ratio criterion. The expected values and variances of the array weights, output powers, and power ratios as functions of the fraction and the number of snapshots are found and compared to computer simulation and real experimental array performance. Reduced-rank covariance approximations and errors in the estimated covariance are also described.

Dilsavor, Ronald Louis↗

On the determination of iridium in diverse geological samples employing HPGe-coincidence/NaI(Tl)-anticoincidence spectrometry

This paper reports the Ir content of a variety of geological samples determined by the high-purity Ge-coincidence/NaI(Tl)-anticoincidence gamma-ray spectrometry (henceforth referred to as coincidence/anticoincidence technique) and by the conventional INAA. The advantages of this technique are: (1) the Ir content of the samples is obtained (ppm to a fraction of ppb ranges) not only by the 468.1 keV peak as in the conventional INAA but also by the 784.6 keV and 920.9 keV sum peaks, which gives more confidence in the values obtained; and (2) it is well suited for the samples with high Compton background for which it is difficult to measure the Ir content by the conventional INAA technique. The practical sensitivity of this technique depends on the sample matrix. Under present experimental conditions, it varied from 0.1 ng for Mn nodules and 0.004 ng for Libyan Desert Glass. Iridium values obtained on small (about 1 microg) olivine grains demonstrate the potential application of this new technique to microsamples. The principle and methodology of this new technique as well as its advantages and disadvantages over the conventional INAA are discussed.

Murali, A. V.↗