At least 109 records · Page 6

Error analysis in the measurement of average power with application to switching controllers

Power measurement errors due to the bandwidth of a power meter and the sampling of the input voltage and current of a power meter were investigated assuming sinusoidal excitation and periodic signals generated by a model of a simple chopper system. Errors incurred in measuring power using a microcomputer with limited data storage were also considered. The behavior of the power measurement error due to the frequency responses of first order transfer functions between the input sinusoidal voltage, input sinusoidal current, and the signal multiplier was studied. Results indicate that this power measurement error can be minimized if the frequency responses of the first order transfer functions are identical. The power error analysis was extended to include the power measurement error for a model of a simple chopper system with a power source and an ideal shunt motor acting as an electrical load for the chopper. The behavior of the power measurement error was determined as a function of the chopper's duty cycle and back EMF of the shunt motor. Results indicate that the error is large when the duty cycle or back EMF is small. Theoretical and experimental results indicate that the power measurement error due to sampling of sinusoidal voltages and currents becomes excessively large when the number of observation periods approaches one-half the size of the microcomputer data memory allocated to the storage of either the input sinusoidal voltage or current.

Maisel, J. E.↗

Correction of confidence intervals in excess relative risk models using Monte Carlo dosimetry systems with shared errors

Introduction: Measurement errors are ubiquitous in epidemiological studies, especially for doses arising from environmental and occupational exposures, which are difficult to assess. Correction methods for independent measurement errors, have been comprehensively described elsewhere, including regression calibration, simulation extrapolation (SIMEX), etc. However, when exposure estimates are constructed using complicated physical and biological models, uncertainties in the dosimetry system can become very complex. In such systems, uncertainties in some parameters may affect a large group of study participants simultaneously, and hence are “shared” as opposed to independent dosimetric uncertainties. Representing the structure of the uncertainty in the dosimetry by providing multiple realizations of possible dose has been described for several studies. The goal of this paper is to implement, and explore the properties of, a generalized estimating equation-based approach to shared uncertainties based on principles described in an earlier paper. Methods: The effects of shared and unshared dosimetry error on parameter estimates and confidence intervals in a generalized excess relative risk model are examined. A post-hoc correction method is implemented that constructs corrected confidence intervals based on an underlying variance structure described in an earlier paper. In this correction method it is assumed that the estimated slope parameter in a linear excess relative risk model is distributed as a mixture of normal and lognormal components. A simulation study of the behavior of this correction was developed based on multiple realizations provided by the Monte Carlo dosimetry system used for the plutonium exposures in the Mayak Worker Cohort and a risk model with close similarity to that used in analyses of lung cancer data in that cohort. Results: In the simulation study we found that shared dose errors severely degraded the coverage probabilities of confidence limits for the slope parameter in the linear excess relative risk model relating uncertain exposure to lung cancer risk. Using our correction method to adjust the confidence intervals provided much improved coverage probabilities for this parameter. A smaller amount of degradation in confidence interval coverage for other parameters (e.g. those in the baseline and dose modification terms) was noted, and the proposed correction method also improved coverage for these parameters as well. Discussion: Compared to other recently described methods our proposed correction method relies on relatively familiar software to fit dose response models. The basic modeling philosophy described here first uses existing Poisson regression methods to estimate parameters in the excess relative risk model; in this first stage mean dose (computed from the multiple realizations) is used as the independent variable in the regression. Once the model is fit we then correct (widen) the standard errors for all parameters using the proposed correction method. The simulation studies indicate that the methods described here are an important contribution to the available tools for dealing with shared measurement errors in complex risk analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sensitivity of Force Specifications to the Errors in Measuring the Interface Force

Force-Limited Random Vibration Testing has been applied in the last several years at the NASA Goddard Space Flight Center (GSFC) and other NASA centers for various programs at the instrument and spacecraft level. Different techniques have been developed over the last few decades to estimate the dynamic forces that the test article under consideration will encounter in the flight environment. Some of these techniques are described in the handbook, NASA-HDBK-7004, and the monograph, NASA-RP-1403. This paper will show the effects of some measurement and calibration errors in force gauges. In some cases, the notches in the acceleration spectrum when a random vibration test is performed with measurement errors are the same as the notches produced during a test that has no measurement errors. The paper will also present the results Of tests that were used to validate this effect. Knowing the effect of measurement errors can allow tests to continue after force gauge failures or allow dummy gauges to be used in places that are inaccessible to a force gage.

Worth, Daniel↗

On the representation and estimation of spatial uncertainty

This paper describes a general method for estimating the nominal relationship and expected error (covariance) between coordinate frames representing the relative locations of objects. The frames may be known only indirectly through a series of spatial relationships, each with its associated error, arising from diverse causes, including positioning errors, measurement errors, or tolerances in part dimensions. This estimation method can be used to answer such questions as whether a camera attached to a robot is likely to have a particular reference object in its field of view. The calculated estimates agree well with those from an independent Monte Carlo simulation. The method makes it possible to decide in advance whether an uncertain relationship is known accurately enough for some task and, if not, how much of an improvement in locational knowledge a proposed sensor will provide. The method presented can be generalized to six degrees of freedom and provides a practical means of estimating the relationships (position and orientation) among objects, as well as estimating the uncertainty associated with the relationships.

Smith, Randall C.↗

Heat Flow Measurement

Heat gauges are used to measure heat flow in industrial activities. They must periodically be certified by instruments designed to provide a heat flux measurement standard. CSTAR, a NASA CCDS, and REMTECH have developed a portable heat flux checker/calibrator. The Q-CHEC can be carried to the heat gauge for certification, reducing out of service time for the gauge and eliminating the need for a replacement gauge during certification. It can provide an "end-to-end" check of the instrumentation measurement system or be used as a standalone calibrator. Because Q-CHEC offers on-site capability to detect and eliminate measurement errors, measurements do not have to be repeated, and money is saved.

Source record↗

SSC Geopositional Assessment of the Advanced Wide Field Sensor

The geopositional accuracy of the standard geocorrected product from the Advanced Wide Field Sensor (AWiFS) was evaluated using digital orthophoto quarter quadrangles and other reference sources of similar accuracy. Images were analyzed from summer 2004 through spring 2005. Forty to fifty check points were collected manually per scene and analyzed to determine overall circular error, estimates of horizontal bias, and other systematic errors. Measured errors were somewhat higher than the specifications for the data, but they were consistent with the analysis of the distributing vendor.

Ross, Kenton↗

Sensitivity of Force Specifications to the Errors in Measuring the Interface Force

Force-Limited Random Vibration Testing has been applied in the last several years at NASA/GSFC for various programs at the instrument and system level. Different techniques have been developed over the last few decades to estimate the dynamic forces that the test article under consideration will encounter in the operational environment. Some of these techniques are described in the handbook, NASA-HDBK-7004, and the monograph, NASA-RP-1403. A key element in the ability to perform force-limited testing is multi-component force gauges. This paper will show how some measurement and calibration errors in force gauges are compensated for w en tie force specification is calculated. The resulting notches in the acceleration spectrum, when a random vibration test is performed, are the same as the notches produced during an uncompensated test that has no measurement errors. The paper will also present the results of tests that were used to validate this compensation. Knowing that the force specification can compensate for some measurement errors allows tests to continue after force gauge failures or allows dummy gauges to be used in places that are inaccessible.

Worth, Daniel↗

Error latency measurements in symbolic architectures

Error latency, the time that elapses between the occurrence of an error and its detection, has a significant effect on reliability. In computer systems, failure rates can be elevated during a burst of system activity due to increased detection of latent errors. A hybrid monitoring environment is developed to measure the error latency distribution of errors occurring in main memory. The objective of this study is to develop a methodology for gauging the dependability of individual data categories within a real-time application. The hybrid monitoring technique is novel in that it selects and categorizes a specific subset of the available blocks of memory to monitor. The precise times of reads and writes are collected, so no actual faults need be injected. Unlike previous monitoring studies that rely on a periodic sampling approach or on statistical approximation, this new approach permits continuous monitoring of referencing activity and precise measurement of error latency.

Young, L. T.↗

Nonsimultaneous coupled laser velocimeter measurement technique: Error prediction for spatially noncoincident measurements

A technique for obtaining orthogonal velocity components from nonorthogonal measurements using the NASA Ames Research Center Long-Range Laser Velocimeter (LRLV) is briefly discussed. A description is then presented of the error that occurs when these nonorthogonal measurements are spatially noncoincident because of positioning inaccuracies, and equations are developed for predicting this error. Sample data are presented and a prediction of the expected error for two typical applications is made. To cover other cases in general, a parametric study is conducted and the results are presented in a tabular format.

Reinath, M. S.↗

Mathematical Models for Doppler Measurements

Error analysis increases precision of navigation. Report presents improved mathematical models of analysis of Doppler measurements and measurement errors of spacecraft navigation. To take advantage of potential navigational accuracy of Doppler measurements, precise equations relate measured cycle count to position and velocity. Drifts and random variations in transmitter and receiver oscillator frequencies taken into account. Mathematical models also adapted to aircraft navigation, radar, sonar, lidar, and interferometry.

Lear, William M.↗

The intercrater plains of Mercury and the Moon: Their nature, origin and role in terrestrial planet evolution. Measurement and errors of crater statistics

Planetary imagery techniques, errors in measurement or degradation assignment, and statistical formulas are presented with respect to cratering data. Base map photograph preparation, measurement of crater diameters and sampled area, and instruments used are discussed. Possible uncertainties, such as Sun angle, scale factors, degradation classification, and biases in crater recognition are discussed. The mathematical formulas used in crater statistics are presented.

Leake, M. A.↗

A novel network-based approach to determining measurement representation error for model evaluation of aerosol microphysical properties

Atmospheric aerosol size and abundance influence radiative effects and climate change. To date, efforts to constrain global climate models’ radiative forcing with in situ aerosol observations have been hamstrung by uncertainty. One source of error, the regional “representation error,” arises when accurate but sparse single-point measurements of atmospheric aerosol distributions are compared with a model value, assuming that the single-point measurement is representative of the model domain. The Portable Optical Particle Spectrometer network in the Southern Great Plains (POPSnet-SGP) campaign has demonstrated that a network of nearly autonomous aerosol instruments operating at ambient temperature and relative humidity (with low measurement error) may be used to quantify measurement representation error and investigate the factors introducing heterogeneity in aerosol distributions across a rural, continental background region. Measurements were made using Portable Optical Particle Spectrometer (POPS) instruments at several sites for five months across the Department of Energy’s Aerosol Radiation Measurement Southern Great Plains (ARM-SGP) User Facility in the central USA. Measurement representation error decreased with longer averaging periods (20-40 % between 1 sec and 1 day), varied between sites by 10 – 20 % for aerosol concentration 140 – 2500 nm in diameter (N_140), and was higher for aerosols > 400 nm in diameter (N_400). Our measurements also show the influence of local meteorology on aerosol surface area (A_140) and size distributions: A_140 is positively correlated with wind speed and relative humidity, negatively correlated with precipitation, and lower given westerly winds. Based on this study, we conclude that the POPSnet approach provides considerably more insight into the spatial variability in the aerosol population that can be used to constrain climate models than would be available from similar networks of PM 2.5 monitors.

54 ENVIRONMENTAL SCIENCES↗

Error analysis of bent ray radio occultation measurments

There are two types of experimental measurement errors of the Doppler data associated with the radio occultation, random and systematic. Random errors are due to thermal noise in the transmission channel, and the phase lock loop, and quantization error in the digital circuitry. These are called noise type errors. The systematic errors are due to geometric uncertainty and equipment phase instability. Considered is the amount of uncertainty, due to random measurement errors, in the refractivity profiles reconstructed by this type of indirect sensing experiment. A class of refractivity profiles is defined which approximately fit the set of measured data. Bounds are placed on the extent of this class of solution profiles. To accomplish this, the sensivity of the reconstructed refractivity profiles to errors in the measured quantity and the statistics of the errors in the measurement are examined.

Saintgermain, R. L.↗