Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Chemical and physical studies of type 3 chondrites. I - Metamorphism related studies of Antarctic and other type 3 ordinary chondrites

New thermoluminescence (TL) sensitivity measurements on 17 finds and one fall are presented, and petrologic assignments are made on the basis of TL sensitivity and silicate heterogeneity. The correlation that exists between TL sensitivity and glow curve shape is discussed, with the difference in the glow curve shapes of meteorite types 3.4 and less and type 3.5 and greater being tentatively attributed to an order-disorder transition in plagioclase, the TL phosphor. A correlation between TL sensitivity and heteogeneity of the silicate composition is found, but it tends to break down in the most heterogeneous meteorites. For Antarctic meteorites, the TL data show a much more restricted range in TL sensitivity than in silicate heterogeneity. The Quinyambie meteorite is the only one not consistent with the observed trend. Several explanations are offered, none of them totally satisfactory.

Sears, D. W.↗

Portable Instrument to Measure CDOM Light Absorption in Aquatic Systems: WPI Success Story

World Precision Instruments, Inc. (WPI), of Sarasota, FL, in collaboration with NASA's John C. Stennis Space Center, has developed an innovative instrument to accurately measure Colored Dissolved Organic Matter (CDOM) absorption in the field. This successful collaboration has culminated in an exciting new device, called the UltraPath, now commercially available through WPI. Traditional methods of measuring absorption of dissolved materials require special handling and storage prior to measurement. Use of laboratory spectrophotometers as the measuring devices have proven time consuming, cumbersome, and delicate to handle. The UltraPath provides a low-cost, highly sensitive, rugged, portable system that is capable of high sensitivity measurements in widely divergent waters.

Source record↗

Investigation of Advanced Radar Techniques for Atmospheric Hazard Detection with Airborne Weather Radar

In 2013 ProSensing Inc. conducted a study to investigate the hazard detection potential of aircraft weather radars with new measurement capabilities, such as multi-frequency, polarimetric and radiometric modes. Various radar designs and features were evaluated for sensitivity, measurement range and for detecting and quantifying atmospheric hazards in wide range of weather conditions. Projected size, weight, power consumption and cost of the various designs were also considered. Various cloud and precipitation conditions were modeled and used to conduct an analytic evaluation of the design options. This report provides an overview of the study and summarizes the conclusions and recommendations.

Pazmany, Andrew L.↗

Differential phase shift of partially reflected radio waves.

The addition of phase difference measurements to differential absorption experiments is shown to be both feasible and desirable. The phase information can provide a more sensitive measurement of electron density above about 75 km. The differential phase shift is only weakly dependent on collision frequency in this range, and so an accurate collision frequency profile is not a prerequisite. The differential phase shift and differential absorption measurements taken together can provide both electron density and collision frequency data from about 70 to 90 km.

Connolly, D. J.↗

Motion-Contrast Sensitivity: Visibility of Motion Gradients of Various Spatial Frequencies

The purpose of our experiments was to estimate basic sensitivity to motion gradients and to evaluate the evidence for second-order integration and differentiation of motion signals. We measured sensitivity to spatially sinusoidal contrast modulation between two oppositely moving bandpass-filtered noise images. The motion-contrast sensitivity function, defined as the inverse of threshold modulation amplitude as a function of modulation spatial frequency, was bandpass in shape with declines at both highest and lowest frequencies. The functions for three noise spatial frequencies had approximately the same shape when modulation frequency was expressed as a fraction of noise frequency. We compared the data with a model in which linear motion filters, whose outputs are squared or rectified, are followed by a second stage of excitatory or inhibitory pooling. The data are consistent with a model in which (1) all excitatory pooling occurs at the linear stage and (2) the second stage contains a large inhibitory pooling area, with a radius approximately eight times that of the linear receptive field.

Watson, Andrew B.↗

Analysis of Particle Image Velocimetry (PIV) Data for Acoustic Velocity Measurements

Acoustic velocity measurements were taken using Particle Image Velocimetry (PIV) in a Normal Incidence Tube configuration at various frequency, phase, and amplitude levels. This report presents the results of the PIV analysis and data reduction portions of the test and details the processing that was done. Estimates of lower measurement sensitivity levels were determined based on PIV image quality, correlation, and noise level parameters used in the test. Comparison of measurements with linear acoustic theory are presented. The onset of nonlinear, harmonic frequency acoustic levels were also studied for various decibel and frequency levels ranging from 90 to 132 dB and 500 to 3000 Hz, respectively.

Blackshire, James L.↗

Charge-injection-device 2 x 64 element infrared array performance

Three 2 x 64 element Si:Bi accumulation-mode charge-injection-device (CID) arrays were tested at low and moderate background to evaluate their usefulness for space-based astronomical observations. Testing was conducted both in the laboratory and in ground-based telescope IR observations. The devices showed an average readout noise level below 200 equivalent electrons, a peak responsivity of 4 A/W, and a noise equivalent power of 3 x 10 to the -17th W/sq rt Hz. This sensitivity compares well with that of nonintegrating discrete extrinsic silicon photoconductors. The array well capacity was significantly smaller than predicted. The measured sensitivity makes extrinsic silicon CID arrays useful for certain astronomical applications. However, their readout efficiency and frequency response represent serious limitations in low-background applications.

Mckelvey, M. E.↗

Pulsed Electric Propulsion Thrust Stand Calibration Method

The evaluation of the performance of any propulsion device requires the accurate measurement of thrust. While chemical rocket thrust is typically measured using a load cell, the low thrust levels associated with electric propulsion (EP) systems necessitate the use of much more sensitive measurement techniques. The design and development of electric propulsion thrust stands that employ a conventional hanging pendulum arm connected to a balance mechanism consisting of a secondary arm and variable linkage have been reported in recent publications by Polzin et al. These works focused on performing steady-state thrust measurements and employed a static analysis of the thrust stand response. In the present work, we present a calibration method and data that will permit pulsed thrust measurements using the Variable Amplitude Hanging Pendulum with Extended Range (VAHPER) thrust stand. Pulsed thrust measurements are challenging in general because the pulsed thrust (impulse bit) occurs over a short timescale (typically 1 micros to 1 millisecond) and cannot be resolved directly. Consequently, the imparted impulse bit must be inferred through observation of the change in thrust stand motion effected by the pulse. Pulsed thrust measurements have typically only consisted of single-shot operation. In the present work, we discuss repetition-rate pulsed thruster operation and describe a method to perform these measurements. The thrust stand response can be modeled as a spring-mass-damper system with a repetitive delta forcing function to represent the impulsive action of the thruster.

Wong, Andrea R.↗

4-Pixel Heterodyne Receiver at 1.9 THz using a CMOS Spectrometer

We present results from a 4x1-pixel 1.9 THz heterodyne array for the astrophysically important [CII] spectral line. A 4-pixel multiplier chain at 1.9 THz, with a compact spacing of 5 mm, is used as an LO. Receiver performance is verified by y-factor measurements with measured sensitivities of 900 K. Finally, using a coherent source near the target frequency of 1.9 THz, we down convert to baseband and measure spectra with both an IBOB and a new CMOS-based spectrometer. The CMOS spectrometer provides several advantages over more traditional spectrometers because of its compact size and low power consumption. This receiver prototype is easily scalable to other frequencies and larger focal plane arrays. Furthermore, because of its compact configuration, it can be easily packaged for orbital or sub-orbital missions.

Mehdi, Imran↗

Performance of charge-injection-device infrared detector arrays at low and moderate backgrounds

Three 2 x 64 element charge injection device infrared detector arrays were tested at low and moderate background to evaluate their usefulness for space based astronomical observations. Testing was conducted both in the laboratory and in ground based telescope observations. The devices showed an average readout noise level below 200 equivalent electrons, a peak responsivity of 4 A/W, and a noise equivalent power of 3x10 sq root of W/Hz. Array well capacity was measured to be significantly smaller than predicted. The measured sensitivity, which compares well with that of nonintegrating discrete extrinsic silicon photoconductors, shows these arrays to be useful for certain astronomical observations. However, the measured readout efficiency and frequency response represent serious limitations in low background applications.

Mckelvey, M. E.↗

Coupled Inertial Navigation and Flush Air Data Sensing Algorithm for Atmosphere Estimation

This paper describes an algorithm for atmospheric state estimation based on a coupling between inertial navigation and flush air data-sensing pressure measurements. The navigation state is used in the atmospheric estimation algorithm along with the pressure measurements and a model of the surface pressure distribution to estimate the atmosphere using a nonlinear weighted least-squares algorithm. The approach uses a high-fidelity model of atmosphere stored in table-lookup form, along with simplified models propagated along the trajectory within the algorithm to aid the solution. Thus, the method is a reduced-order Kalman filter in which the inertial states are taken from the navigation solution and atmospheric states are estimated in the filter. The algorithm is applied to data from the Mars Science Laboratory entry, descent, and landing from August 2012. Reasonable estimates of the atmosphere are produced by the algorithm. The observability of winds along the trajectory are examined using an index based on the observability Gramian and the pressure measurement sensitivity matrix. The results indicate that bank reversals are responsible for adding information content. The algorithm is applied to the design of the pressure measurement system for the Mars 2020 mission. A linear covariance analysis is performed to assess estimator performance. The results indicate that the new estimator produces more precise estimates of atmospheric states than existing algorithms.

Karlgaard, Christopher D.↗

Performance evaluation of the SAO VLG-11 atomic hydrogen masers

A new generation of frequency standards, the VLG-11 hydrogen maser, has been designed and built at the Smithsonian Astrophysical Observatory (SAO). A comprehensive series of environmental and short-term stability tests on three VLG-11 masers has been completed and evaluated. The test results reported here show substantial improvements over previous hydrogen masers in measured sensitivity to variations in ambient temperature, barometric pressure, and magnetic fields. The maser frequency stability, as represented by the two-sample (Allan) variance, has been measured for averaging times ranging from 1 to 100,00 seconds. The variance is lower than 1 x 10 to the -15th for averaging intervals between 1400 and 20,000 seconds. For times shorter than 4000 seconds, the measured stability data agree remarkably well with theoretical values calculated from thermal noise mechanisms and the 'noise within the linewidth' regime is clearly discernable in the data.

Levine, M. W.↗

Satellite and Ground-based Radiometers Reveal Much Lower Dust Absorption of Sunlight than Used in Climate Models

The ability of dust to absorb solar radiation and heat the atmosphere is one of the main uncertainties in climate modeling and the prediction of climate change. Dust absorption is not well known due to limitations of in situ measurements. New techniques to measure dust absorption are needed in order to assess the impact of dust on climate. Here we report two new independent remote sensing techniques that provide sensitive measurements of dust absorption. Both are based on remote sensing. One uses satellite spectral measurements, the second uses ground based sky measurements from the AERONET network. Both techniques demonstrate that Saharan dust absorption of solar radiation is several times smaller than the current international standards. Dust cooling of the earth system in the solar spectrum is therefore significantly stronger than recent calculations indicate. We shall also address the issue of the effects of dust non-sphericity on the aerosol optical properties.

Kaufman, Y. J.↗

Spectrally Resolved Synthetic Aperture Imaging Interferometer: Final Report of NASA Innovative Advanced Concepts - Phase 1 Study

The Spectrally Resolved Synthetic-Aperture Imaging Interferometer (SRSAII) is a system proposed to provide high-resolution and high-sensitivity measurements of astronomical objects. SRSAII uses long baseline interferometric methods to achieve the resolution and low-noise, high time-precision detection to achieve the sensitivity. The primary goal of the SRSAII study was to lay out a framework for using new optical physics technologies to directly resolve, both spatially and spectrally, the disk of an exoplanet. In addition to the ambitious goal of directly resolving an exoplanet, the SRSAII team also sought to identify science opportunities achievable with intermediate system configurations which may offer resolution significantly higher than the current state of the art, but insufficient for direct resolution of an exoplanetary disk. An operational SRSAII system can function with essentially arbitrarily large baselines, achieving correspondingly high angular resolution. The primary limitation occurs in the system sensitivity, which became the major technical focus for study. In this report, we compare the predicted performance (sensitivity in SNR (Signal-to-Noise Ratio) along with angular resolution) of three interferometric techniques: direct detection (also known as homodyne interferometry), multi-channel intensity interferometry (using the Hanbury Brown and Twiss effect), and multi-channel heterodyne interferometry (using an optical frequency comb as a local oscillator). Additionally, quantum-assisted interferometry is also explored as a prospective enhancement of established methods. This report presents a survey of the technologies that enable the SRSAII techniques - optical frequency combs, single photon detectors, and photonic integrated circuits. These technologies are the basis of methods critical to SRSAII's success: precision timing, length and frequency metrology, sensitive photodetection, fine-scale wavelength filtering, and dense multi-channel operation. Lastly, we give some notional performance metrics and propose some possible experimental observations.

High Resolultion↗

A comparison of water vapor derived from GPS occultations and global weather analyses

Occultation measurements from the Global Positioning System (GPS) should improve upon this situation. Individual occultations yield profiles of specific humidity accurate to 0.2 to 0.5 g/kg providing sensitive measurements of lower and middle tropospheric water vapor with global coverage in a unique, all-weather, limb-viewing geometry with several hundred metres to a kilometre vertical resolution. The authors have derived water vapor profiles from June 21 to July 4, 1995

global↗

Wide-Field Imaging Using Nitrogen Vacancies

Nitrogen vacancies in bulk diamonds and nanodiamonds can be used to sense temperature, pressure, electromagnetic fields, and pH. Unfortunately, conventional sensing techniques use gated detection and confocal imaging, limiting the measurement sensitivity and precluding wide-field imaging. Conversely, the present sensing techniques do not require gated detection or confocal imaging and can therefore be used to image temperature, pressure, electromagnetic fields, and pH over wide fields of view. In some cases, wide-field imaging supports spatial localization of the NVs to precisions at or below the diffraction limit. Moreover, the measurement range can extend over extremely wide dynamic range at very high sensitivity.

Englund, Dirk Robert↗

The Measurement of Aerosol Optical Properties using Continuous Wave Cavity Ring-Down Techniques

Large uncertainties in the effects that aerosols have on climate require improved in situ measurements of extinction coefficient and single-scattering albedo. This paper describes the use of continuous wave cavity ring-down (CW-CRD) technology to address this problem. The innovations in this instrument are the use of CW-CRD to measure aerosol extinction coefficient, the simultaneous measurement of scattering coefficient, and small size suitable for a wide range of aircraft applications. Our prototype instrument measures extinction and scattering coefficient at 690 nm and extinction coefficient at 1550 nm. The instrument itself is small (60 x 48 x 15 cm) and relatively insensitive to vibrations. The prototype instrument has been tested in our lab and used in the field. While improvements in performance are needed, the prototype has been shown to make accurate and sensitive measurements of extinction and scattering coefficients. Combining these two parameters, one can obtain the single-scattering albedo and absorption coefficient, both important aerosol properties. The use of two wavelengths also allows us to obtain a quantitative idea of the size of the aerosol through the Angstrom exponent. Minimum sensitivity of the prototype instrument is 1.5 x 10(exp -6)/m (1.5 M/m). Validation of the measurement of extinction coefficient has been accomplished by comparing the measurement of calibration spheres with Mie calculations. This instrument and its successors have potential to help reduce uncertainty currently associated with aerosol optical properties and their spatial and temporal variation. Possible applications include studies of visibility, climate forcing by aerosol, and the validation of aerosol retrieval schemes from satellite data.

Strawa, Anthony W.↗

The Measurement of Aerosol Optical Properties Using Continuous Wave Cavity Ring-Down Techniques

Large uncertainties in the effects that aerosols have on climate require improved in-situ measurements of extinction coefficient and single-scattering albedo. This abstract describes the use of continuous wave cavity ring-down (CW-CRD) technology to address this problem. The innovations in this instrument are the use of CW-CRD to measure aerosol extinction coefficient, the simultaneous measurement of scattering coefficient, and small size suitable for a wide range of aircraft applications. Our prototype instrument measures extinction and scattering coefficient at 690 nm and extinction coefficient at 1550 nm. The instrument itself is small (60 x 48 x 15 cm) and relatively insensitive to vibrations. The prototype instrument has been tested in our lab and used in the field. While improvements in performance are needed, the prototype has been shown to make accurate and sensitive measurements of extinction and scattering coefficients. Combining these two parameters, one can obtain the single-scattering albedo and absorption coefficient, both important aerosol properties. The use of two wavelengths also allows us to obtain a quantitative idea of the size of the aerosol through the Angstrom exponent. Minimum sensitivity of the prototype instrument is 1.5 x 10(exp -6)/m (1.5/Mm). Validation of the measurement of extinction coefficient has been accomplished by comparing the measurement of calibration spheres with Mie calculations. This instrument and its successors have potential to help reduce uncertainty currently associated with aerosol optical properties and their spatial and temporal variation. Possible applications include studies of visibility, climate forcing by aerosol, and the validation of aerosol retrieval schemes from satellite data.

Strawa, A. W.↗