Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Precision spectroscopy of fast, hot, exotic isotopes using machine-learning-assisted event-by-event Doppler correction

We propose an experimental scheme for performing sensitive, high-precision laser spectroscopy studies on fast exotic isotopes. By inducing a stepwise resonant ionization of the atoms traveling inside an electric field and subsequently detecting the ion and the corresponding electron, time-, and position-sensitive measurements of the resulting particles can be performed. Using a mixture density network, we can leverage this information to predict the initial energy of individual atoms and thus apply a Doppler correction of the observed transition frequencies on an event-by-event basis. We conduct numerical simulations of the proposed experimental scheme and show that kHz-level uncertainties can be achieved for ion beams produced at extreme temperatures ( > 10 8 K), with energy spreads as large as 10 keV and nonuniform velocity distributions. The ability to perform in-flight spectroscopy, directly on highly energetic beams, offers unique opportunities to study short-lived isotopes with lifetimes in the millisecond range and below, produced in low quantities, in hot and highly contaminated environments, without the need for cooling techniques. Such species are of marked interest for nuclear structure, astrophysics, and new physics searches. Published by the American Physical Society 2024

Udrescu, S. M. (ORCID:000000021989576X)↗

Dissipative Superradiant Spin Amplifier for Enhanced Quantum Sensing

Quantum metrology protocols exploiting ensembles of N two-level systems and Ramsey-style measurements are ubiquitous. However, in many cases excess readout noise severely degrades the measurement sensitivity; in particular in sensors based on ensembles of solid-state defect spins. We present a dissipative “spin-amplification” protocol that allows us to dramatically improve the sensitivity of such schemes, even in the presence of realistic intrinsic dissipation and noise. Our method is based on exploiting collective (i.e., superradiant) spin decay, an effect that is usually seen as a nuisance because it limits spin-squeezing protocols. We show that our approach can allow a system with a highly imperfect spin readout to approach standard-quantum-limit-like scaling in N within a factor of 2, without needing to change the actual readout mechanism. Our ideas are compatible with several state-of-the-art experimental platforms where an ensemble of solid-state spins (NV centers, SiV centers) is coupled to a common microwave or mechanical mode.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlated Noise Estimation with Quantum Sensor Networks

We address the metrological problem of estimating collective stochastic properties imprinted on a network of quantum sensors. Canonical examples include center-of-mass quadrature fluctuations in a system of bosonic modes and correlated dephasing in an ensemble of qubits (e.g., spins), bosons, or fermions. We develop a theoretical framework to determine the limits of correlated (weak) noise estimation with quantum sensor networks and reveal the requirements for entanglement advantage. Notably, an advantage emerges from the synergistic interplay between quantum correlations of the sensors and “classical” correlations of the noises. Here, we determine optimal entangled probe states and identify a sensing protocol—reminiscent of a many-body echo—that achieves the fundamental limits of measurement sensitivity for a broad class of problems, unveiling a route toward entanglement-enhanced metrology of correlated many-body phenomena.

Quantum metrology↗

Impact of Thermal Stress on Attachment and Stability of High Temperature Strain Sensors

Static and dynamic strain sensing is required in high-temperature (HT), harsh-environments (HE) for industrial, aerospace, and energy sector applications to ensure equipment and process safety, reduce the cost of operation and maintenance, and increase process efficiency. Challenges that arise in HT HE sensing applications include device mounting, packaging, integrity, and stability to HT HE conditions. In previously reported work, static and dynamic strain surface acoustic wave resonator (SAWR) sensors were fabricated on langasite (LGS) and mounted on Inconel 625 strain beams for wireless testing up to 400°C. In this work, it has been identified that after subjecting the mounted SAWR strain sensor to thermal cycling between 100°C and 425°C, the measured sensitivity to dynamic strain decreased by 73% due to cracking at the adhesive/LGS interface, further deteriorating after additional thermal cycles. Strain modeling of the mounted LGS sensor chip up to 400°C revealed the existence of concentrated strain at the borders of the LGS chip. Microcracks caused by dicing make the chip boarders the most susceptible location for cracks to initiate when the sensor is subjected to thermal stress. In an attempt to mitigate the high strain at the LGS chip borders due to heating, adhesive shaping is proposed in this work. Simulations indicate a strain reduction of 50% at the border is achieved using both circular and triangular adhesive shapes, while also reducing the maximum strain over the entire adhesive/LGS interface by around 30%. Furthermore, the technique is thus promising for improving the integrity, reliability, and stability of static and dynamic strain sensors, particularly while operating under HT HE with several hundreddegree Celsius temperature excursions.

47 OTHER INSTRUMENTATION↗

Passive Digital Sensing Method and Its Implementation on Passive RFID Temperature Sensors

Benefitting from the advancement of digital electronics in the 20 th century, sensors have also gradually evolved from analog to digital. As semiconductor components are required in digital sensors, a power supply is still needed for the sensor. To eliminate the need for a power supply a concept of passive digital sensing is proposed. Different from the semiconductor-based electrical digital sensing method, the parameter to be measured is first converted to a mechanical signal, then the mechanical signal is encoded to multiple digital bits by a passive digitizer, where each bit is identified as open or short state that is detectable by general IO ports. To demonstrate the proposed sensing concept, a passive RFID temperature sensor is implemented using a bimetallic coil as the temperature sensing unit. The 6-bit binary codes are acquired and transmitted by a passive RFID that is powered by an energy harvester. Furthermore, the test results show that the temperature sensor has a measurement sensitivity of 1.32 °C/bit and a working distance over 10 meters.

47 OTHER INSTRUMENTATION↗

Early detection of amyloid load using 18F-florbetaben PET

A low amount and extent of Aβ deposition at early stages of Alzheimer’s disease (AD) may limit the use of previously developed pathology-proven composite SUVR cutoffs. This study aims to characterize the population with earliest abnormal Aβ accumulation using 18F-florbetaben PET. Quantitative thresholds for the early (SUVR early ) and established (SUVR estab ) Aβ deposition were developed, and the topography of early Aβ deposition was assessed. Subsequently, Aβ accumulation over time, progression from mild cognitive impairment (MCI) to AD dementia, and tau deposition were assessed in subjects with early and established Aβ deposition. The study population consisted of 686 subjects (n = 287 (cognitively normal healthy controls), n = 166 (subjects with subjective cognitive decline (SCD)), n = 129 (subjects with MCI), and n = 101 (subjects with AD dementia)). Three categories in the Aβ-deposition continuum were defined based on the developed SUVR cutoffs: Aβ-negative subjects, subjects with early Aβ deposition (“gray zone”), and subjects with established Aβ pathology. SUVR using the whole cerebellum as the reference region and centiloid (CL) cutoffs for early and established amyloid pathology were 1.10 (13.5 CL) and 1.24 (35.7 CL), respectively. Cingulate cortices and precuneus, frontal, and inferior lateral temporal cortices were the regions showing the initial pathological tracer retention. Subjects in the “gray zone” or with established Aβ pathology accumulated more amyloid over time than Aβ-negative subjects. After a 4-year clinical follow-up, none of the Aβ-negative or the gray zone subjects progressed to AD dementia while 91% of the MCI subjects with established Aβ pathology progressed. Tau deposition was infrequent in those subjects without established Aβ pathology. This study supports the utility of using two cutoffs for amyloid PET abnormality defining a “gray zone”: a lower cutoff of 13.5 CL indicating emerging Aβ pathology and a higher cutoff of 35.7 CL where amyloid burden levels correspond to established neuropathology findings. These cutoffs define a subset of subjects characterized by pre-AD dementia levels of amyloid burden that precede other biomarkers such as tau deposition or clinical symptoms and accelerated amyloid accumulation. The determination of different amyloid loads, particularly low amyloid levels, is useful in determining who will eventually progress to dementia. Quantitation of amyloid provides a sensitive measure in these low-load cases and may help to identify a group of subjects most likely to benefit from intervention.

60 APPLIED LIFE SCIENCES↗

Sensitivity analysis of homogenized cross section in AP1000 lattices

The two-step method for light water reactor simulation consists of performing lattice-level calculations to determine homogenized properties of the lattice for a variety of configurations and burnups then performing a core-level calculation which relies on those pre-calculated lattice properties. Calculating the homogenized lattice properties for the specific conditions needed in the core-level calculation relies on interpolating from the pre-calculated lattice properties. Although many studies have explored different models that can be used for this interpolation, there is a need to explore how to appropriately parameterize the lattice for those interpolation models. The present study uses linear sensitivity methods to determine the sensitivity of homogenized cross sections to both instantaneous and historical values of state variables. The results from this study can be used to inform parameterizations which more appropriately capture history effects in homogenized cross section interpolation. Two different lattices are used for this analysis from the AP1000 reactor, one includes burnable absorbers. It was found that early in the cycle, the historical values of state variables have little effect on the instantaneous value of the homogenized cross sections explored here - especially in the case of the lattice containing burnable absorbers. However, it was found that later in the cycle, the thermal fission homogenized cross section was sensitive to the historic states of the lattice. In fact, using the average of a state variable as a predictor for interpolation models may be insufficient for capturing historic effects due to more recent states having larger sensitivity measures than less recent states. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation the Geotech GS-13BH Borehole Seismic Sensor

Sandia National Laboratories has tested and evaluated the Geotech GS-13BH borehole sensor. The sensor provides a response similar to that of the standard GS-13 short-period seismic sensor intended for pier-installations in a borehole package. The purpose of this seismometer evaluation was to determine a measured sensitivity, amplitude and phase response, self-noise and dynamic range, passband and acceleration response of its calibration coil.

47 OTHER INSTRUMENTATION↗

Entangled-photon interferometry for plasmas

Sub-picosecond coincidence timing from nonlocal intensity interference of entangled photons allows quantum interferometry for plasmas. Using a warm plasma dispersion relation, we correlate phase measurement sensitivity with different plasma properties or physics mechanisms over 6 orders of magnitude. Due to N α (α ≤ - 1/2) scaling with the photon number N, quantum interferometry using entangled light can probe small signals in plasmas not previously accessible. As an example, it is predicted that plasmas will induce shifts to a Gaussian dip, a well-known quantum optics phenomenon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Outgassing of casted and 3D printed silicones

Outgassing of 3D printed and casted silica-filled silicones was studied using a standard ASTM E-595 procedure and a modified Soreq’s method that allows very sensitive measurements of the outgassing kinetics even at low temperatures, 20 – 50 °C. We studied three different silica-filled silicones, non-porous cased M9787, and 3D printed LL50 and 40P materials. The present report shows that vacuum outgassing products of polysiloxane-based materials include multiple species. In addition to chemisorbed and physisorbed water outgassing, previously studied by TPD, polymer fragments of varying sizes evaporate as well. The chemical composition of the condensable volatile species collected on a Germanium substrate, was analyzed by FTIR. It was shown that all studied materials produce mostly PDMS-based outgassing products that form stable droplet-like structure on the Ge substrate. The highest amount of the condensable volatile species was measured for LL50. Isothermal TGA in nitrogen atmosphere of the LL50 material was compared to the standard vacuum outgassing. The results of TGA showed lower mass loss and higher water regain. The kinetics of the outgassing at relatively low temperatures of 20, 30 and 50 °C was studied using Thermoelectric Quartz Crystal Microbalance (TQCM). The TQCM surface was held at -10 °C to enhance condensation of the outgassed moisture. The analysis presented here, when combined with the extensive previous work on moisture outgassing, provides a better understanding of the aging mechanism of polysiloxane-based materials. In this work we show that outgassing techniques, usually applied for qualification of polymers for space-related applications, may be used as a complementary method to study thermal degradation and aging of silica-based silicones. Our results indicate that the long-term degradation mechanics and thermal degradation products depend primarily on the chemical composition of silicone-based material and only slightly affected by the manufacturing process. Surprisingly, the surface-to-volume ratio of the 3D printed vs. casted/molded materials showed only minor effect on the outgassing kinetic parameters.

36 MATERIALS SCIENCE↗

The Design and Integrated Performance of SPT-3G

Abstract SPT-3G is the third survey receiver operating on the South Pole Telescope dedicated to high-resolution observations of the cosmic microwave background (CMB). Sensitive measurements of the temperature and polarization anisotropies of the CMB provide a powerful data set for constraining cosmology. Additionally, CMB surveys with arcminute-scale resolution are capable of detecting galaxy clusters, millimeter-wave bright galaxies, and a variety of transient phenomena. The SPT-3G instrument provides a significant improvement in mapping speed over its predecessors, SPT-SZ and SPTpol. The broadband optics design of the instrument achieves a 430 mm diameter image plane across observing bands of 95, 150, and 220 GHz, with 1.2′ FWHM beam response at 150 GHz. In the receiver, this image plane is populated with 2690 dual-polarization, trichroic pixels (∼16,000 detectors) read out using a 68× digital frequency-domain multiplexing readout system. In 2018, SPT-3G began a multiyear survey of 1500 deg 2 of the southern sky. We summarize the unique optical, cryogenic, detector, and readout technologies employed in SPT-3G, and we report on the integrated performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simons Observatory: Characterization of the Large Aperture Telescope Receiver

The Simons Observatory (SO) is a ground-based cosmic microwave background (CMB) survey experiment that currently consists of three 0.42 m small-aperture telescopes and one 6 m large-aperture telescope (LAT), located at an elevation of 5200 m in the Atacama Desert in Chile. At the LAT’s focal plane, SO will install >62,000 transition-edge sensor detectors across 13 optics tubes (OTs) within the Large Aperture Telescope Receiver (LATR), the largest cryogenic camera ever built to observe the CMB. Furthermore we report on the validation of the LATR in the laboratory and the subsequent dark testing and validation within the LAT. We show that the LATR meets cryogenic, optical, and detector specifications required for high-sensitivity measurements of the CMB. At the time of writing, the LATR is installed in the LAT with six OTs (corresponding to >31,000 detectors), and the LAT mirrors and remaining seven OTs are undergoing development.

Astronomical instrumentation↗

Neutrino Hunting: Looking through a UV Lens Scintillation Photon Detection in a Large-Volume Liquid Argon Time Projection Chamber, Exposed to a Multi-GeV Charged Particle Beam

The Deep Underground Neutrino Experiment (DUNE) will be a world-class neutrino observatory and nucleon decay detector designed to answer fundamental questions about elementary particles and their role in the universe. The DUNE experiment will consist of a a Near Detector, located at Fermilab, and a Far Detector, approximately 1.5~km underground at the Sanford Underground Research Facility in South Dakota, located $\sim$1300~km away. The accelerator complex at Fermilab will host an intense beam of neutrinos directed toward the two detectors. My dissertation centers on the implementation of technologies used to detect scintillation photon signals in liquid argon in the context of the DUNE's Far Detector Single-Phase (SP) module design, and features direct contributions to the Photon Detection System (PDS) deployed in the ProtoDUNE-SP Large-Volume Liquid Argon Time Projection Chamber (LArTPC) prototype. The PDS is needed for non-beam event timing, such as atmospheric neutrinos, proton d ecay, and supernova detection. The PDS provides a prompt signal ($t_{0}$ information) for micro-second event time determination, which improves the TPC's spatial localization along drift direction, enables accurate ionization-signal-attenuation determination, and even provides calorimetry. My dissertation will discuss an overview of the DUNE and ProtoDUNE-SP experiment and how we detect neutrinos in LAr, via charge and scintillation light. It will discuss my core experimental and analysis work, in regards to the Photon Detection System; including my contributions in establishing procedures for the commissioning and integration for the Photon Detector System that will be valuable during the construction, installation, commissioning, and operations of the DUNE Far Detector. In addition, it will comprehensively discuss the capability of three different photon detection technologies, and their characteristics and responses to muon and electron beam particles over a range of beam momenta , from 0.3~GeV/$c$ - 7~GeV/$c$. Further, the overall progress detailed in this thesis will help pave the way toward understanding the physical properties of these detectors, which will contribute to the success of the sensitivity measurements required for determining the neutrino mass hierarchy and $\delta_{CP}$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity and Importance Measure Analyses for Various Design Architectures for High Safety-Significant Safety-Related Digital Instrumentation and Control Systems of Nuclear Power Plants

A transition from analog instrumentation and control (I&C) technologies to digital I&C technologies is taking place for license renewals of existing nuclear power plants and for operating licenses of new advanced reactors. This transition necessitates research on risk and economic assessments of digital I&C technologies to ensure the long-term safety and reliability of vital systems, reduce uncertainty in licensing costs in addition to timeline, support integration of digital I&C systems in the plant, and find the most efficient technology upgrades. Adding redundancy within systems or components is a common means of improving design safety; however, it can also make designs more prone to common-cause failures (CCFs). Introducing diversity into redundant systems or components is a way to mitigate and possibly eliminate CCFs, but it also increases plant complexity and may be costly. The balance between redundancy and diversity remains a challenge for digital I&C systems. This study performs sensitivity and importance analyses for four design architectures of two digital I&C systems—the reactor-trip system and the engineered safety features actuation system. For each system, two architectures are examined, including a redundant, non-diverse configuration and a redundant, diverse configuration. The sensitivity analysis will provide insights on the impact of introducing diversity to system reliability. The importance results will help identify risk-significant and risk-sensitive components and failure modes, which may be good candidates for future design improvement.

99 GENERAL AND MISCELLANEOUS↗

Measurement of the Sensitivity of Two-Particle Correlations in $\mathcal{pp}$ Collisions to the Presence of Hard Scatterings

A key open question in the study of multiparticle production in high-energy pp collisions is the relationship between the “ridge”—i.e., the observed azimuthal correlations between particles in the underlying event that extend over all rapidities—and hard or semihard scattering processes. In particular, it is not known whether jets or their soft fragments are correlated with particles in the underlying event. To address this question, two-particle correlations are measured in pp collisions at $\sqrt{s}$=13 TeV using data collected by the ATLAS experiment at the LHC, with an integrated luminosity of 15.8 pb -1 , in two different configurations. In the first case, charged particles associated with jets are excluded from the correlation analysis, while in the second case, correlations are measured between particles within jets and charged particles from the underlying event. Second-order flow coefficients, v2, are presented as a function of event multiplicity and transverse momentum. These measurements show that excluding particles associated with jets does not affect the measured correlations. Moreover, particles associated with jets do not exhibit any significant azimuthal correlations with the underlying event, ruling out hard processes contributing to the ridge.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SPECTER: an instrument concept for CMB spectral distortion measurements with enhanced sensitivity

Deviations of the cosmic microwave background (CMB) energy spectrum from a perfect blackbody uniquely probe a wide range of physics, ranging from fundamental physics in the primordial Universe (μ-distortion) to late-time baryonic feedback processes (y-distortion). While the y-distortion can be detected with a moderate increase in sensitivity over that of COBE/FIRAS, the ΛCDM-predicted μ-distortion is roughly two orders of magnitude smaller and requires substantial improvements, with foregrounds presenting a serious obstacle. Within the standard model, the dominant contribution to μ arises from energy injected via Silk damping, yielding sensitivity to the primordial power spectrum at wavenumbers k ≈ 1-10 4 Mpc -1 . Here, we present a new instrument concept, SPECTER, with the goal of robustly detecting μ. The instrument technology is similar to that of LiteBIRD, but with an absolute temperature calibration system. Using a Fisher approach, we optimize the instrument's configuration to target μ while marginalizing over foreground contaminants. Unlike Fourier-transform-spectrometer-based designs, the specific bands and their individual sensitivities can be independently set in this instrument, allowing significant flexibility. We forecast SPECTER to observe the ΛCDM-predicted μ-distortion at ≈ 5σ (10σ) assuming an observation time of 1 (4) year(s) (corresponding to mission duration of 2 (8) years), after foreground marginalization. Our optimized configuration includes 16 bands spanning 1–2000 GHz with ∼degree-scale angular resolution at ∼ 150 GHz and 1100 total detectors. SPECTER will additionally measure the y-distortion at sub-percent precision and its relativistic correction at percent-level precision, yielding tight constraints on the total thermal energy and mean temperature of ionized gas.

CMBR experiments↗

Characterizing Canopy Openness in Open Forests: Spherical Densiometer and Canopy Photography Are Equivalent but Less Sensitive than Direct Measurements of Solar Radiation

In forest ecosystems, canopy openness affects understory light availability, plant growth, and tree species recruitment, thus shaping future forest composition, structure, and functional diversity. Foresters must correctly and quickly measure canopy openness to meet their management objectives. To help guide the selection of an appropriate method for measuring canopy openness, we compared three common techniques that vary in cost, complexity, and time required for measurements and data processing: smartphone-based hemispherical photography, spherical densiometer measurements, and direct measurements of solar radiation (using AccuPAR ceptometer). We measured canopy openness using these three methods on 28 permanent forest health monitoring plots in pine-oak forests of the Central Pine Barrens of Long Island in New York State. By analysis of variance and regression analyses, we found the three methods (particularly densiometer and hemispherical photographs) yielded broadly equivalent and strongly positively correlated descriptions of canopy openness. The direct measurements of solar radiation seemed to have a greater potential to detect subtle variation in forest understory light. Forest managers may sufficiently characterize canopy openness using quick and cheap methods (e.g., spherical densiometers) and avoid larger costs of devices for direct light measurements (e.g., ceptometers) and the larger data processing times of hemispherical photography.

54 ENVIRONMENTAL SCIENCES↗