Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Rapid Cryogenic Electrical Characterization of Materials and Devices Using Gifford-McMahon Cryocoolers

Thin-film heterostructures are necessary building blocks for superconducting and phononic quantum computing devices. Many new generations of quantum hardware demand extensive materials research to optimize performances at cryogenic temperatures (below 10 K). Here, we demonstrate compact cryogenic measurement systems capable of reaching sub-10K temperatures in less than three hours with the ability to measure AC/DC resistance and dielectric properties of thin-film materials. Our platform utilizes Gifford-McMahon (GM) cryocoolers as effective tools for providing high throughput cooling-warming cycles. We successfully used the GM-based measurement systems to measure 1) the superconducting transition temperature for Nb thin films (T c ~7.8 K), and 2) the temperature dependence of the dielectric constant in SiO 2 thin films down to 10 K. The fast electrical characterization feedback will be critical in developing robust materials and components for cryogenic computing devices.

36 MATERIALS SCIENCE↗

Online Alpha Monitoring of High Cs-137 Hanford and SRS High Level Waste with Tensioned Metastable Fluid Detectors

The Department of Energy’s Hanford and Savannah River Sites maintain millions of gallons of caustic supernate and salt high activity waste in their high-level waste (HLW) tank farm inventories. The Savannah River Site is currently treating this waste with a calixarene-based solvent extraction of Cs-137 to reduce these inventories. Hanford is employing an at-tank crystalline silico titanate (CST) based solid phase extraction methodology to reduce their liquid HLW inventories. Due to the high solubility of Cs-137 and the relative insolubility of the actinides in these caustic waste forms, the beta to alpha radioactivity ratio can often exceed six orders of magnitude in the feed solutions to these treatment processes. This unique characteristic leads to significant technical challenges in making rapid gross alpha measurements in the presence of the overwhelming beta, gamma, as well as dissolved sodium salt in these HLW matrices. Conventional radioanalytical techniques, such as liquid scintillation analysis or gas flow proportional counting require significant radiochemistry preparation prior to the radiometric measurements for gross alpha activity. These required pretreatments render these technologies untenable for rapid quantification of gross alpha activity that could be required to support on or at-line measurements ensuring a waste stream will meet regulatory requirements. The radiation measurement properties of Tensioned Metastable Fluid Detectors (TMFDs) have been studied by Purdue University’s Taleyarkhan research group for well over a decade. Fluids tensioned to the appropriate degree will rupture when struck by radiation, resulting in a measurable cavitation event. The negative pressure generating this tension can be adjusted by centrifugal rotation or by acoustic means in such a way that these cavitation events can be generated from alpha radiation but will not be generated by beta or gamma radiation. Purdue University and the Savannah River National Laboratory are currently collaborating to develop a gamma/beta blind, spectroscopic alpha measurement system based on the Tensioned Metastable Fluid Detector technology to provide a potential solution for performing rapid gross alpha measurements on these high gamma/beta sample matrices. Measurements using the Indirect Drive Acoustically Tensioned Metastable Fluid Detectors developed as part of this collaboration were performed with an alpha emitting radionuclide. Successful determination of gross alpha activity was observed, indicating a potential pathway for rapid gross alpha measurements in remote-handled shielded cells or in process situations requiring online alpha monitoring. Measurements using this system have been conducted on high beta activity solutions, demonstrating the beta blind capability of this system. Measurements are currently underway to test the system’s capability to measure gross alpha activity on Savannah River Site high level waste high Cs-137 samples that have been measured by the SRNL radiochemistry team. This work was supported by the DOE EM Technology Development program.

DiPrete, David [Savannah River National Laboratory↗

Next-Generation NGV Driver Information System

Measuring the amount of fuel contained in the tank of a Natural Gas Vehicle (NGV) is not as straightforward as it is for a liquid-fueled vehicle. The fuel in an NGV is a compressed gas at pressures up to 4200psig, and its pressure changes with temperature. The current state-of-the-art, which is used on most NGVs, is a simple pressure gauge as a rough guide for remaining fuel. This presents a high degree of error because pressure varies widely depending on temperature. Immediately following refueling, the temperature in the vehicle’s cylinders is often greater than 150°F. As the driver pulls out of the fueling station and begins consuming gas, the pressure drops at a very fast rate due to expansion cooling of the gas. This pressure drop appears to the driver to be a very rapid decrease in fuel level, reducing trust in the fuel level indication and leading to concern about the distance the vehicle can travel before refueling again, which is known as “range anxiety.”

03 NATURAL GAS↗

URBANopt™ District Energy Systems HVAC Measures (DES_HVAC) [SWR-21-30]

DES_HVAC is a repository of a Parametric Analysis Tool (PAT) project and for scripts related to modeling of different HVAC systems for buildings in a district served by a district thermal energy system. The Measures directory contains the new measures developed to extract data from the simulations. Update these measures and not the measures in the Test Suite measures directory. PAT should be used to update the measures in the Test Suite project. The Test directory contains a PAT project for testing the functionality of the measures. The PAT project is named HVAC_Test and can be opened in PAT > 3.x.

Allen, Amy↗

Measurement placement in electric power transmission and distribution grids: Review of concepts, methods, and research needs

Sensing and measurement systems are quintessential to the safe and reliable operation of electric power grids. Their strategic placement is of ultimate importance because it is not economically viable to install measurement systems on every node and branch of a power grid, though they need to be monitored. An overwhelming number of strategies have been developed to meet oftentimes multiple conflicting objectives. The prime challenge in formulating the problem lies in developing a heuristic or an optimisation model that, though mathematically tractable and constrained in cost, leads to trustworthy technical solutions. Further, large-scale, long-term deployments pose additional challenges because the boundary conditions change as technologies evolve. For instance, the advent of new technologies in sensing and measurement, as well as in communications and networking, might impact the cost and performance of available solutions and shift initially set conditions. Also, the placement strategies developed for transmission grids might not be suitable for distribution grids, and vice versa, because of unique characteristics; therefore, the strategies need to be flexible, to a certain extent, because no two power grids are alike. Despite the extensive literature on the present topic, the focus of published works tends to be on a specific subject, such as the optimal placement of measurements to ensure observability in transmission grids. There is a dearth of work providing a comprehensive picture for developing optimal placement strategies. Because of the ongoing efforts on the modernisation of electric power grids, there is a need to consolidate the status quo while exposing its limitations to inform policymakers, industry stakeholders, and researchers on the research-and-development needs to push the boundaries for innovation. Accordingly, this paper first reviews the state-of-the-art considering both transmission and distribution grids. Then, it consolidates the key factors to be considered in the problem formulation. Finally, it provides a set of perspectives on the measurement placement problem, and it concludes with future research directions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated electrochemical nuclear decontamination system

An electrochemical cell that oxidizes a solution provides a continuous and stable supply of an oxidizing ion solution to a fixture or vessel used for the purposes of decontaminating metal and metal alloys. The electrochemical cell includes an anode compartment that oxidizes the solution in nitric acid or methane sulfonic acid at a rate equal to or greater than a rate of reduction, or generates the oxidizing ions prior to use in a batch. The electrochemical cell is part of a larger system that facilitates online measurement system which measures the oxidizing ion solution and the dissolved PuO 2 , UO 2 , AmO 2 , other radionuclides, or other contaminates in real-time. Solution decontamination system removes the dissolved PuO 2 /UO 2 /AmO 2 , other radionuclides, or other contaminates from the oxidizing ion solution, real time acoustic monitoring of the thickness of the surface being contaminated, and automation of a delivery system facilitates flow between surface and electrochemical cell.

Karmiol, Benjamin↗

An LES-based airborne Doppler lidar simulator and its application to wind profiling in inhomogeneous flow conditions

Wind profiling by Doppler lidar is common practice and highly useful in a wide range of applications. Airborne Doppler lidar can provide additional insights relative to ground-based systems by allowing for spatially distributed and targeted measurements. Providing a link between theory and measurement, a first large eddy simulation (LES)-based airborne Doppler lidar simulator (ADLS) has been developed. Simulated measurements are conducted based on LES wind fields, considering the coordinate and geometric transformations applicable to real-world measurements. The ADLS provides added value as the input truth used to create the measurements is known exactly, which is nearly impossible in real-world situations. Thus, valuable insight can be gained into measurement system characteristics as well as retrieval strategies. As an example application, airborne Doppler lidar wind profiling is investigated using the ADLS. For commonly used airborne velocity azimuth display (AVAD) techniques, flow homogeneity is assumed throughout the retrieval volume, a condition which is violated in turbulent boundary layer flow. Assuming an ideal measurement system, the ADLS allows to isolate and evaluate the error in wind profiling which occurs due to the violation of the flow homogeneity assumption. Overall, the ADLS demonstrates that wind profiling is possible in turbulent wind field conditions with reasonable errors (root mean squared error of 0.36 m s –1 for wind speed when using a commonly used system setup and retrieval strategy for the conditions investigated). Nevertheless, flow inhomogeneity, e.g., due to boundary layer turbulence, can cause an important contribution to wind profiling error and is non-negligible. Results suggest that airborne Doppler lidar wind profiling at low wind speeds (<5 m s –1 ) can be biased, if conducted in regions of inhomogeneous flow conditions.

17 WIND ENERGY↗

Method and system for measurement of impedance of electrochemical devices

The present disclosure provides methods for determining impedance of an electrochemical device by electrically connecting a variable impedance in parallel with the electrochemical device; electrically connecting a power supply to the electrochemical device, the power supply generating a power supply current; modulating a current through the variable impedance; measuring a stack current flowing through the electrochemical device; measuring, at the electrochemical device, a voltage across at least a portion of the electrochemical device; and calculating, based on the measured stack current and the measured voltage, the impedance of the electrochemical device. Systems for performing such methods are also provided.

Klein, Jr., Walter Ellis↗

A New Reflected Target Optical Assessment System: Stage 1 Development Results

NREL has completed stage 1 development of an indoor optical measurement tool for fully assembled heliostats and single facets. This tool began as an indoor version of NREL’s outdoor Non-Intrusive Optical (NIO) measurement technique [1]. It uses similar techniques to other available tools (deflectometry, photogrammetry, etc.), but is designed to require very little infrastructure, labor, and time to set up and collect surface slope and canting measurements, making it a valuable tool for quality assurance and laboratory measurement of heliostat optics. It accomplishes this by using computer vision, photogrammetry, and multiple images stitched together to minimize the printed target size and required setup precision. This adaptable setup is useful for taking measurements at a variety of heliostat pointing angles, and for measuring fully assembled heliostats on the assembly line. In this paper, we describe the methodology behind the measurement system, present an initial analysis of its uncertainty and sensitivity, and compare it with established optical measurement systems.

Kesseli, Devon (ORCID:0000000193113036)↗

A New Reflected Target Optical Assessment System - Stage 1 Development Results: Preprint

NREL has completed stage 1 development of an indoor optical measurement tool for fully assembled heliostats and single facets. This tool began as an indoor version of NREL's NIO technique. It uses similar techniques to other available tools (deflectometry, photogrammetry, etc.), but is designed require very little infrastructure, labor, and time to set up and collect surface slope and canting measurements on fully assembled heliostats and parabolic trough facets, making it a valuable tool for quality assurance and laboratory measurement of helio-stat optics. It accomplishes this by using computer vision, photogrammetry, and multiple images stitched together to minimize the printed target size and required setup precision. This adaptable setup is useful for taking measurements at a variety of heliostat pointing angles, and for measuring fully assembled heliostats on the assembly line. The measurement system's methodology and an analysis of its uncertainty, sensitivity and comparison with established optical measurement systems is described below.

canting↗

Development of the high energy engineering X-ray (HEX) superconducting wiggler, magnetic measurement, installation, and commissioning

The High energy Engineering X-ray (HEX) diffraction beamline at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL) is the first high-energy beamline capable of reaching 200 keV for a monochromatic beam. With the 3 GeV electron beam energy for the NSLS-II ring, only the superconducting wiggler (SCW) producing greater than 4 T peak field can cover these ranges with a sufficient number of photons. The 1.2 m-long HEX-SCW has a period length of 70 mm and a field strength on-axis of 4.3 T. It utilizes no liquid helium, and the vertical aperture size of the electron beam vacuum chamber is 8 mm. Unlike regular undulators/wigglers, there is no standard configuration for the magnetic measurement system for superconducting insertion devices. The NSLS-II Insertion Devices group has developed, in collaboration with the vacuum group, a novel in-vacuum Hall mapper with a 1.75 m in-vacuum linear motor and an in-vacuum flip coil system utilizing many commercial-off-the-shelf products. The measurements were conducted at the BNL, and the device was installed in the ring and commissioned. Here, this paper provides a description of the SCW and its magnetic measurement systems, as well as a brief account of the installation and commissioning efforts.

36 MATERIALS SCIENCE↗

WAMS-Based HVDC Damping Control for Cyber Attack Defense

Owing to the fast and large power regulating the capacity of the HVDC system, the wide-area measurement system (WAMS) based high voltage direct current (HVDC) system has been regarded as a prospective solution to deal with the low-frequency oscillation issue. However, due to the vulnerability of the WAMS communication, WAMS based HVDC system control can be a prime target of malicious penetrations that could lead to disastrous events. To remediate this adverse effect, an improved WAMS based HVDC damping control framework is proposed in this paper. First, a lightweight network named Attack Shuffle convolutional neural Networks (ASNet) is proposed to learn the characteristics of cyber attacks. Then, a model-free-based cyber attack defense framework is introduced to quickly identify the attack types based on the continuous wavelet transform and ASNet. Additionally, an improved control framework of the WAMS and HVDC-based wide-area power oscillation damping control (WH-PODC) is developed to provide different response control for mitigation of the impact of cyber attacks. Finally, the performance of the proposed WH-PODC control framework is evaluated with real PMU data in multiple scenarios in RTDS, where the results indicate that the response intensity can be kept under multiple types of cyber attacks while providing similar effectiveness in oscillation suppression to conventional controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar Radiation Research Laboratory (SRRL) Core Project Final Report: Fiscal Years 2022-2024

The Solar Radiation Research Laboratory (SRRL) at the National Laboratory of the Rockies (NLR) is a world-leading solar calibration and measurement facility and maintains and disseminates the World Radiation Reference (essentially the W/m2) for the United States that is essential for traceable and accurate measurements of solar radiation at all solar generation facilities. SRRL operates two calibration facilities that meet International Standards Organization-17025 (ISO-17025) standards and provide unique high-quality calibrations to NREL and other U.S. Department of Energy laboratories. The Baseline Measurement System (BMS) at SRRL provides a high-quality record of solar irradiance and surface meteorological conditions. SRRL capabilities are used to develop (1) improved methods for the calibration of solar radiometers; (2) new standards through the ISO, the International Electrotechnical Commission (IEC), and the American Standards for Testing of Materials (ASTM) International; (c) solar radiation and meteorological models; and (d) advanced instrumentation and methods for operating solar measurement stations. The SRRL datasets are also critical for the validation of new models and datasets, such as the National Solar Radiation Database (NSRDB). The research and development of solar radiation measurement systems and resource modeling techniques are essential for advancing the scientific basis for producing reliable resource data. Specifically, the spatial, temporal, and spectral (wavelength dependency) characteristics of the solar resource are required in several different time frames for various project phases.

14 SOLAR ENERGY↗

Experimental validation of a Kalman observer using linearized OpenFAST and a fully instrumented 1:70 model

Abstract To enable real‐time monitoring and control strategies for floating offshore wind turbines, accurate information about the state of the system is needed. This paper details the application of a Kalman filter to the UMaine VolturnUS‐S floating wind platform to provide accurate state estimates in real time using minimal system measurements. The midfidelity nonlinear simulation tool OpenFAST was used to generate the underlying linear state‐space model for the Kalman filter. This linear model and its limitations are demonstrated through comparison with experimental data collected on a 1:70 froude‐scaled model of the floating platform and tower. Using a selection of five measurements from the real system, a Kalman filter was developed to provide estimates for the remaining system states and measurements. These estimates were then validated against the experimental values collected from testing of the scale model. Validation of the Kalman filter produced accurate estimates of surge, heave, and tower base bending moment, measurements of which were not available to the Kalman filter. Performance of the Kalman filter was tested and validated over a range of sea conditions from rated wind speed to storm events and demonstrated robustness in the Kalman filter to maintain accuracy across all operating conditions despite significant error in the underlying linear model for extreme conditions.

17 WIND ENERGY↗

Measurement Uncertainty in One-of-a-kind Experiments

A golden standard in science is to repeat an experimental measurement multiple times and calculate the measured value with experimental uncertainty by following well developed statistical procedures. For various reasons – cost, technical difficulty, international treaties, ethics of dealing with human or animal subjects, ecology - many important experiments and observations can not be repeated. Astronomy, earthquakes, hurricanes produce data from one-of-a-kind events. When information is not available in any other way, it should not be dismissed as qualitative, anecdotal evidence only. Analyzed in a mathematically rigorous way, it produces quantitative experimental data. Analysis of data from one-of-a-kind event differs from analysis of repeated experiments’ data. For repeated experiments, the experimental error includes a range of true values generated by repetitions of the experiment, and measurement uncertainty caused by detectors. They are independent. Repetitions of any experiment, as similar as achievable, always have built-in differences resulting in a range of the true values rather than in a single value. Measurement uncertainty depends on the measurement system only. Digital measurements have very small uncertainty, frequently smaller than the range of true experimental values resulting from built-in differences in the experiment repetitions. When data from one–of–a kind experiment are analyzed, only the measurement uncertainty can be reported.

42 ENGINEERING↗

In Situ Cloud Measurements at AMF3 Field Campaign Report

This campaign is a follow-up project to the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility field campaign entitled Cloud Droplet Measurement System for TBS that was focused on integration of the Mesa Photonics' cloud droplet measurement system (CDMS) into the DOE ARM tethered balloon system (TBS) and its initial field testing at ARM’s Southern Great Plains (SGP) atmospheric observatory in February–March 2020. The CDMS performs in situ measurement of droplet size distribution function and droplet number density in clouds. These characteristics are important cloud microphysical properties that are critical input parameters for atmospheric models and are also useful for proper calibration and validation of performance of other atmospheric measurement instrumentation. The overall goals of this campaign were to deploy the CDMS on the DOE ARM TBS, test its compatibility with the TBS under relevant conditions, and perform a series of in-cloud measurements at the third ARM Mobile Facility (AMF3) at Oliktok Point, Alaska. The TBS flights were conducted on November 12–19, 2020.

54 ENVIRONMENTAL SCIENCES↗

Uranium Mass Attribute System (UMAS) Study: Evaluation of Options against the Arms Control Evaluation Criteria

In this FY19 study, a range of possible measurement systems for confirming a U-235 mass attribute were identified. The systems were reviewed for their applicability in a potential future arms control agreement, and a subset of the eight most plausible systems were selected for further evaluation against the Arms Control Evaluation Criteria (ACEC). The evaluation results were then used to identify a primary and secondary recommended measurement system for confirming a U-235 mass attribute on warheads, nuclear components of warheads, and/or materials as part of a hypothetical arms control agreement.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Open Radiation Monitoring: Conceptual System Design

The Open Radiation Monitoring (ORM) Project seeks to develop and demonstrate a modular radiation detection architecture designed specifically for use in arms control treaty verification (ACTV) applications that will facilitate rapid development of trusted systems to meet the needs of potential future treaties. Development of trusted systems to support potential future treaties is a complex and costly endeavor that typically results in a purpose-built system designed to perform one specific task. The majority of prior trusted system development efforts have relied on the use of commercial embedded computers or microprocessors to control the system and process the acquired data. These processors are complex, making authentication and certification of measurement systems and collected data challenging and time consuming. We believe that a modular architecture can be used to reduce more complex systems to a series of single-purpose building blocks that could be used to implement a variety of detection modalities with shared functionalities. With proper design, the functionality of individual modules can be confirmed through simple input/output testing, thereby facilitating equipment inspection and in turn building trust in the equipment by all treaty parties. Furthermore, a modular architecture can be used to control data flow within the measurement system, reducing the risk of "hidden switches" and constraining the amount of sensitive information that could potentially be inadvertently leaked. This report documents a conceptual modular system architecture that is designed to facilitate inspection in an effort to reduce overall authentication and certification burden. As of publication, this architecture remains in a conceptual phase and additional funding is required to prove out the utility of a modular architecture and test the assumptions used to rationalize the design.

61 RADIATION PROTECTION AND DOSIMETRY↗