Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Super resolution for magneto-optical microscopy

Sub-diffraction limited magneto-optical microscopy, such as Kerr or Faraday effect microscopy, provide many advantages to fields of science and technology for measuring, or imaging, the magnetization structures and magnetization domains of materials. Disclosed is a method and system for performing sub-diffraction limited magneto-optic microscopy. The method includes positioning a microlens or microlens layer relative to a surface of a sample to image the surface of the sample, forming a photonic nanojet to probe the surface of the sample, and receiving light reflected by the surface of the sample or transmitted through the sample at an imaging sensor. The methods and associated systems and devices enable sub-diffraction limited imaging of magnetic domains at resolutions 2 to 8 times the classical diffraction limit.

te Velthuis, Suzanne Gabriëlle Everdine↗

Systems and methods for optical measurement of cross-wind

Various technologies pertaining to optical measurement of cross-wind are described herein. A beam of light is emitted along a trajectory through a shooting space from a location of a shooter to a target using a laser. The beam is reflected by the target, and the beam is received at two optical detectors. Due to changes in the index of refraction of air along the path of the beam, an envelope signal atmospherically encoded on the beam is received at each of the two apertures at different times. A signal analyzer receives a signal from each of the detectors and outputs data indicative of an average speed of the cross-wind along the trajectory in the shooting space based upon a time delay between the signals.

Bagwell, Brett↗

Isotopic analysis of sub-nanogram neodymium loads using new ATONA™ amplifiers

The long-term gains of the ATONA™ amplifiers are shown to have less than 1 ppm variability. Repeat measurements of the JNdi-1 reference material demonstrate the ability of the ATONA™ amplification technology to make measurements of 143 Nd/ 144 Nd ratios with 23 ppm external reproducibility on 100-pg loads. The effect of increasing integration time on analytical reproducibility is also displayed as increasing integration time from 10 to 30s reduced the external measurement uncertainty from 37 to 23 ppm. These measurements represent an improvement of more than a factor of 3 in external measurement reproducibility relative to previously published 143 Nd/ 144 Nd measurements of 100-pg loads. Furthermore, this new technology will allow for the measurement of smaller samples for precise isotope ratios and open new avenues of research in the geological and nuclear forensic communities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Novel Optical Instrument for On-Line Measurement of Particle Size Distribution—Application to Clean Coal Technologies

A flow cell is a critical measurement interface for many optical instruments. However, the flows are often sampled under harsh conditions, such as under high pressure and/or high temperature, in the presence of particles, moisture, vapors with high dew points or corrosive gases. Therefore, obtaining a high-optical-quality flow cell that does not perturb the measurement is a significant challenge. To address this challenge, we proposed a new flow cell that employs a unique laminar coaxial flow field (for the purge and sample flows). A test system was built to conduct particle size distribution (PSD) measurements with no sampling bias using a state-of-the-art analyzer (Malvern Panalytical Insitec). The results revealed that the measurement zone is well defined solely by the sample flow, and the optical windows are well protected by the purge flow, with minimal risk of any depositions from the sample flow. Using this flow cell, the Insitec can successfully measure PSD under high pressure and temperature under moist, corrosive conditions without generating any sampling bias. Importantly, we successfully applied this flow cell for on-line PSD measurement for the flue gas of a 100 kWth pressurized oxy-coal combustor operating at 15 bara.

Cheng, Mao (ORCID:0000000213273900)↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Envelope Improvements and Advanced Air Sealing

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson, et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (GHP) (4.0 COP, 20.5 EER) With Envelope Improvements. This measure combines a two-stage GHP with envelope improvements as a single package. As this package is a combination of two other measures, this document focused on documenting the results associated with this combination of technologies, with individual measure documents for two-stage GHPs and envelope improvements providing the information on the details of these measures. When the two technologies are combined, envelope improvements can modestly reduce energy consumption by a further 10%-15%, but also reduce the required size of the ground heat exchanger and heat pump by approximately 33% on average across all sites. The cost of installing envelope improvements in these homes is likely to be more than paid for by the reduction in equipment and drilling costs in these buildings for the majority of the stock.

15 GEOTHERMAL ENERGY↗

Multi-modal chemical characterization of highly viscous submicrometer organic particles

Distinguishing highly viscous organic particles within complex mixtures of atmospheric aerosol and accurate descriptions of their composition, size distributions, and mixing states are challenges at the forefront of aerosol measurement science and technology. Here, we present results obtained from complementary single-particle measurement techniques employed for the in-depth characterization of highly viscous particles. In this study, we demonstrate advantages and synergy of this multi-modal particle characterization approach based on the analysis of individual viscous particles formed in the air-discharged waste produced by a common sewer pipe rehabilitation technology. Using oil immersion flow microscopy, we investigate particle size distributions and morphology of colloidal components present in field-collected aqueous waste condensates. We compare these results with corresponding measurements of viscous particles formed in drying droplets of the aerosolized discharged waste. The colloidal components and viscous particles were found to be approximately 10 µm and 0.5 µm, respectively. The aerosolized viscous particles exhibited a spherical morphology, while the colloidal particles appeared noticeably fractal, resembling fragments of a cured composite material. Chemical imaging of the viscous particles collected on substrates was performed using scanning electron microscopy and soft X-ray spectro-microscopy techniques. Through these methods, comprehensive description of these particles emerged, confirming their high solid-like viscosity, wide-ranging sizes, diverse carbon speciation with high degrees of oxygenation, and high organic volume fractions. The aerosolized viscous particles were further characterized using high-throughput single particle mass spectrometry. This technique provides real-time measurements of composition, size, and morphological metrics for large numbers of individual particles, enabling the identification of their distinct mass spectrometric signatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Expanded Capabilities and Opportunities for Virtual Beamline Code

In the 25 years since LLNL broke ground on the National Ignition Facility (NIF) - a cornerstone of the National Nuclear Security Administration’s Stockpile Stewardship Program - the NIF and Photon Science (NIF&PS) Directorate has steadily pushed the boundaries of laser physics, nonlinear optics, and photonics in service of inertial confinement fusion experiments, and advanced photon sources development. Beyond the 192 beamlines of the primary laser facility with its world-record energy and fusion yields, NIF&PS capabilities have expanded to include chirped-pulse amplification, kilojoule petawatt-class short-pulse systems to generate hard x-ray radiographic probes, high-average power lasers as secondary sources for generation or wake field particle acceleration along directed energy applications, and other scientific pursuits. The Computing Directorate partners with NIF&PS on numerous projects and technologies from diagnostic measurements and high performance control systems to data analysis, information technology infrastructure, and scientific simulation code development. “This strong collaboration enables cutting-edge science, particularly with regard to physics-based modeling and simulation,” says physicist Jean-Michel Di Nicola. One crucial capability for NIF&PS is the Virtual Beamline (VBL) laser simulation code. It can model all the major laser physics and technology involved in the design optimization, commissioning, and operations of advanced laser architectures from tabletop to NIF-scale. VBL provides researchers with high-fidelity models and high-resolution calculations of laser performance predictions—including for the entire NIF laser system, the Advanced Radiographic Capability, parts of the High Repetition-Rate Advanced Petawatt Laser System laser delivered to the Czech Republic, and the Optical Science Laser. After more than two decades of experimentally verified physics and computing enhancements, this unique workhorse code is wrapping up another major milestone: migration from Java to C++ with a flurry of user interface and optimization features, as well as laser physics and high-resolution enhancements thanks to parallel execution on Livermore Computing platforms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Smart sensor for online situational awareness in power grids

Waveforms in power grids typically reveal a certain pattern with specific features and peculiarities driven by the system operating conditions, internal and external uncertainties, etc. This prompts an observation of different types of waveforms at the measurement points (substations). An innovative next-generation smart sensor technology includes a measurement unit embedded with sophisticated analytics for power grid online surveillance and situational awareness. The smart sensor brings additional levels of smartness into the existing phasor measurement units (PMUs) and intelligent electronic devices (IEDs). It unlocks the full potential of advanced signal processing and machine learning for online power grid monitoring in a distributed paradigm. Within the smart sensor are several interconnected units for signal acquisition, feature extraction, machine learning-based event detection, and a suite of multiple measurement algorithms where the best-fit algorithm is selected in real-time based on the detected operating condition. Embedding such analytics within the sensors and closer to where the data is generated, the distributed intelligence mechanism mitigates the potential risks to communication failures and latencies, as well as malicious cyber threats, which would otherwise compromise the trustworthiness of the end-use applications in distant control centers. The smart sensor achieves a promising classification accuracy on multiple classes of prevailing conditions in the power grid and accordingly improves the measurement quality across the power grid.

Dehghanian, Payman↗

A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High throughput single cell multiomics platform [Abstract]

In this collaborative project, PNNL and Scienion will co-develop an integrated microfluidic technology to co-measure the transcriptome and proteome in single cells. The technology will enable us to efficiently separate proteins from mRNA transcripts between two microchips, barcode the molecules, and measure them separately with next-generation sequencing and mass spectrometry, respectively. Multicellular organisms contain diverse cell types and tremendous cell-to-cell heterogeneity that dictates a multitude of biological functions in both physiological and pathological environments. Even in the case of microbes, these genetically identical organisms can randomly differentiate into many subpopulations that assume different roles for the survival of the community. Bulk-scale measurements are insufficient to resolve such complexities. The development and applications of high throughput single-cell omics technologies have transformed our understanding of cellular heterogeneities and their differential responses to internal signaling events or external stimulations. Despite these advances, most current single-cell omic technologies provide information on only one type of biomolecule. Perse, such measurements provide incomplete information because the cell phenotype is determined by multiple layers of biomolecules and the interplay between genome, epigenome, transcriptome, and proteome. For example, mRNA abundance in one cell can not be precisely referred to the corresponding DNA and protein in other cells because of the potential subtle difference in genotype (e.g., somatic mutation or copy number variation) or phenotype (external microenvironment and cell-cell interactions). As such, parallel measurement of multiple biomolecules in the same single cells can offer unique advantages compared with measuring them separately in different single cells. Scienion is a world-leading biotech company focusing on precision liquid handling and its application in single-cell whole-genome sequencing and RNA sequencing. PNNL is the leading institution in ultrasensitive mass spectrometry, microfluidics, and untargeted single-cell proteomics (scProteomics). This collaboration will facilitate a unique fusion between scTranscriptomics capability at Scienion and scProteomics capabilities at PNNL to, for the first time, perform both untargeted transcriptomics and proteomics from the same single cells.

59 BASIC BIOLOGICAL SCIENCES↗

Investigation of Process Emissions during Thermal Cutting of Clad Metals from the Nuclear Sector - 20183

Typically, reactor pressure vessels as well as steam generators comprising low alloyed steel with a cladding of stainless steel. Recently the permissible values for Cr (VI) in the air of the working areas have been reduced in Germany from 100 μg/m{sup 3} to 1 μg/m{sup 3} air. This results in the danger that even with low-alloy steel with claddings these limit values would be exceeded when using flame cutting technologies. In order to ensure compliance with the permissible limit values, exhaust gas systems with gas cleaning measures are provided. The process emission test shall replace the assumptions required for the design of these systems with measured values. NUKEM Technologies Engineering Services GmbH (NUKEM) has chosen autogenous flame cutting as an example of a thermal cutting system for process emission testing, as there are no proven values in the literature for the Cr (VI) and NiOx emissions produced. The autogenous flame cutting can be used for a variety of cutting tasks within decommissioning projects. In order to simulate the material to be cut, mock ups were generated and cut from information about the material specification for the reactor pressure vessel from existing nuclear power plants including possible claddings. The cutting length needed for analysis in the test will be maximum 100 mm. The airborne emissions from the thermal cutting process will be captured and analyzed as follows: - Dust emission: The generated particles will be collected by a hood equipped with strong suction device and suitable filter elements. The resulting filter is gravimetrically measured before and after the tests. - Particle Size Distribution: The airborne particle size distribution measurement will result in figures for the size and number of particles arising from the thermal cutting process. - Gas Analysis: The gas analysis enables the determination of e.g. CO{sub 2}, CO, O{sub 3}, NO, NO{sub 2}. - Cr (VI) and NiOx Analysis: For the Cr (VI) and NiOx analysis, samples of the filter residue will be taken. As a result Cr (VI) in relation to total Cr as well as the Ni content will be determined by ICP-optically emission spectroscopy and put in relation to the total dust amount. The process emissions test itself as well as the necessary gas analyses and spectroscopic analyses were carried out at the Institute of Materials Science (IW) of Leibniz Universitaet Hannover (LUH). The results of the process emission tests are used to confirm the design of the gas cleaning systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Innovative Method for Reliable Measurement of PEM Water Electrolyzer Component Resistances

Understanding the sheet resistance of porous electrodes is essential for improving the performance of polymer electrolyte membrane (PEM) water electrolyzers and related technologies. Despite its importance, existing methods often fail to provide reliable and comprehensive data, especially for porous materials with complex morphologies and non‐uniform thicknesses. This study introduces a robust and straightforward method for determining the sheet resistance of porous electrodes using a novel probe concept based on industrial printed circuit board (PCB) technology. This probe measures resistance across ten distances, ranging from 250 µm to 2500 µm, enabling local mapping of resistance. The study focuses on the sheet resistance of key components in PEM water electrolyzers, including the gas diffusion layer (GDL), porous transport layer (PTL), and catalyst layers deposited on a membrane. Additionally, an image‐processing‐based method is presented to obtain the thickness distribution of the studied catalyst layers, facilitating a detailed analysis of the electrical in‐plane resistivity with thickness variations. Overall, this methodology has the potential to expedite material integration and bridge the gap between electrode engineering and single‐cell testing, thereby advancing the development of PEM water electrolyzers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Circular Economy for Photovoltaics in Service of Energy Transition

The challenge of energy transition is immediate and immense; current projections target 75 TW of photovoltaics (PV) capacity by 2050. While any transition to renewable energy technology is preferable to the current fossil-based system, it is ideal to improve the sustainability of PV to minimize negative environmental and social impacts. Circular economy (CE) has been proposed as a method to improve the sustainability of PV, especially for emerging materials like perovskites. CE is a set of actions, principles, and systems which aim to design out waste and keep products and materials in use, to reduce environmental impacts and enable sustainable development. At the most basic level, CE is "reduce, reuse, recycle", the R-actions, in ranked order. CE of a PV technology can be metricized in a variety of ways, such as the Material Circularity Indicator (Smith and Jones, Ellen MacArthur Foundation, 2019) or recycling rates. Unfortunately, standard CE metrics have several shortcomings for measuring renewable energy technologies in the context of deployment for energy transition (Figge 2018, Saidani 2019): 1) Only measure mass flows; 2) De-prioritization of the use phase in favor of mass circularity when scoring; and 3) Tight focus on a single product scale The use phase and energy flows of PV are key to energy transition, and therefore need to be quantified. Additionally, correlating product-scale to system-scale is necessary for quantifying the environmental impacts of energy transition. Life Cycle Assessment (LCA) can address some of these concerns, but also focuses on a single product scale and has trouble capturing the dynamics of system-scale energy transition, such as the interaction of module lifetime with manufacturing demands for energy transition deployment schedules. Therefore, we developed an open-source Python-based system dynamics model to quantify the mass, energy and carbon impacts of CE R-actions for PV technologies in the energy transition; PV in the CE (PV ICE) (Ovaitt & Mirletz 2021). The tool captures supply chains from material extraction through end of life, incorporating 5 circular end of life pathways. PV ICE takes in any evolving bill of materials, module properties and deployment schedule to support researchers and decision makers with data-backed insights. In this work, we quantify and compare proposed CE sustainable PV module designs and lifecycle management strategies, spanning currently commercialized technologies, government and industry technology targets, and several low Technology Readiness Level (TRL) emerging PV technologies, including perovskites. Our analyses capture the projected evolutions of lifetime, efficiency and material circularity of these PV technologies, as well as their material supply chains. Our analyses emphasize the importance of examining a suite of metrics to identify priorities and tradeoffs, and inform design or lifecycle management decisions holistically. Previous analyses have demonstrated the central importance of PV module lifetime to support energy transition while minimizing impacts. High levels of material circularity (>90%) enable minimizing lifecycle wastes, can reduce virgin material demands if paired with improving efficiency, but demonstrate tradeoffs in energy return on investment. In the fervor of new material and technology development, it is important to remember that CE is not the end goal; decarbonization and energy transition are the end goal. CE should be used in service to improve the sustainability of PV, and R-actions evaluated for their usefulness and efficacy to this end.

carbon↗

From Event Data to Wind Power Plant DQ Admittance and Stability Risk Assessment

This paper presents a dynamic event data-based stability risk assessment method for power grids with high penetrations of inverter-based resources (IBRs). This method relies on obtaining the IBRs' DQ admittance through dynamic event data and computing the system's eigenvalues based on the admittance models. Two critical technologies are employed in this research, including time-domain and frequency-domain data fitting and dq-frame voltage and current signal derivation. The first technology is key to obtaining the s-domain expressions from the transient response data, and the s-domain DQ admittance model from the frequency-domain measurements. The second technology is key to obtaining the dq-frame voltage and current signals from either the three-phase instantaneous measurements or the phasor measurement unit (PMU) data. The method is illustrated using data generated from a Type-4 wind power plant modeled in PSCAD. This paper demonstrates the technical feasibility of the proposed approach.

17 WIND ENERGY↗

Initial Field Testing in the Deep Subsurface for the Thermal Breakout Project for Measuring In Situ Stress

The current state-of-the-art technology for in situ stress measurements involves an integrated approach that combines borehole breakout observations, drilling-induced tensile fractures, and hydraulic fracturing tests (i.e., mini-fracs); however, this methodology has several limitations that often prevent successful in situ stress measurements. One major limitation is that breakouts do not appear in every borehole and are generally a natural occurrence that cannot easily be controlled. Because borehole breakouts are used to measure the maximum horizontal in situ stress magnitude, the absence of borehole breakouts presents a major data gap for in situ stress measurements. As a response to this data gap a new thermal breakout technology is being developed that will provide a method for thermally inducing borehole breakouts and obtaining consistent measurements of the maximum horizontal stress magnitude. This thermal breakout technology involves heating the borehole and increasing the thermoelastic compressive stress in the rock until a breakout develops, which is directly correlated to the maximum horizontal stress magnitude. An initial component of the thermal breakout project involves developing a prototype downhole tool and performing field testing in the deep subsurface. The primary objective of the initial tool development and field testing is to provide a physical proof of concept for the thermal breakout technology. Three thermal breakout field tests were performed at approximately 4850 feet deep in the Sanford Underground Research Facility. Each test was performed in a borehole that had been previously used for overcoring stress measurements. The third and final test successfully created two diametrically opposed breakouts after deploying the thermal breakout tool for approximately 3 hours of continuous heating. Post-analysis of the thermally induced breakouts confirmed that the thermal breakout orientation directly corresponds to the known in situ stress orientation and magnitude.

Voegeli, Sam↗

Bench-Scale Apparatus for Rapid, Simultaneous, Comprehensive Vapor–Liquid Equilibrium and Kinetic Property Measurements to Advance CO 2 Capture Solvent Technology

We present here, the design, fabrication, and testing of a new "pressure, volume, temperature (PVT)" apparatus that enables rapid standardized testing for viscosity, vapor–liquid equilibria, and kinetics for water-lean carbon capture solvents. This unit is the first of its kind where equilibrium data are collected during operation as a PTx (pressure–temperature–composition) cell while kinetic data are collected simultaneously with an internal mini wetted-wall contactor (WWC) using controlled adjustments of CO 2 injections to allow for measurements of gas flux (in and out of the liquid). Additionally, in situ measurements of viscosity data are also continuously collected while a solvent is in circulation during gas absorption. This cell empowers comprehensive testing of critical CO 2 capture solvent properties in a single measurement, ensuring all data are collected at the same temperature, pressure, and CO 2 loading. This apparatus also expedites screening of materials since less than 50 mL of sample is needed as compared to 2–3 L needed to get similar data from a conventional WWC. In conclusion, we describe here the methodology of data collected on this new PVT cell, nicknamed “Gary” in honor of Professor Gary Rochelle, for multiple water-lean amine solvents, which we compare to data collected from conventional instrumentation for amine testing.

Zheng, Richard [STARS Technology Corporation, Rich↗

Monitoring agroecosystem productivity and phenology at a national scale: A metric assessment framework

Effective measurement of seasonal variations in the timing and amount of production is critical to managing spatially heterogeneous agroecosystems in a changing climate. Although numerous technologies for such measurements are available, their relationships to one another at a continental extent are unknown. Using data collected from across the Long-Term Agroecosystem Research (LTAR) network and other networks, we investigated correlations among key metrics representing primary production, phenology, and carbon fluxes in croplands, grazing lands, and crop-grazing integrated systems across the continental U.S. Metrics we examined included gross primary productivity (GPP) estimated from eddy covariance (EC) towers and modelled from the Landsat satellite, Landsat NDVI, and vegetation greenness (Green Chromatic Coordinate, GCC) from tower-mounted PhenoCams for 2017 and 2018. Overall, our analysis compared production dynamics estimated from three independent ground and remote platforms using data for 34 agricultural sites constituting 51 site-years of co-located time series. Pairwise sensor comparisons across all four metrics revealed stronger correlation and lower root mean square error (RMSE) between end of season (EOS) dates (Pearson R ranged from 0.6 to 0.7 and RMSE from 32.5 to 67.8) than start of season (SOS) dates (0.46 to 0.69 and 40.4 to 66.2). Overall, moderate to high correlations between SOS and EOS metrics complemented one another except at some lower productivity grazing land sites where estimating SOS can be challenging. Growing season length estimates derived from 16-day satellite GPP (179.1 days) were significantly longer than those from PhenoCam G CC (70.4 days, p adj < 0.0001) and EC GPP (79.6 days, p adj < 0.0001). Landscape heterogeneity did not explain differences in SOS and EOS estimates. Annual integrated estimates of productivity from EC GPP and PhenoCam G CC diverged from those estimated by Landsat GPP and NDVI at sites where annual production exceeds 1000 gC/m –2 yr –1 . Based on our results, we developed a “metric assessment framework” that articulates where and how metrics from satellite, eddy covariance and PhenoCams complement, diverge from, or are redundant with one another. The framework was designed to optimize instrumentation selection for monitoring, modeling, and forecasting ecosystem functioning with the ultimate goal of informing decision-making by land managers, policy-makers, and industry leaders working at multiple scales.

54 ENVIRONMENTAL SCIENCES↗

Identify and Assess Technical Challenges in Safeguards Measurements of Spent Advanced Reactor Fuels

Advanced reactor (AR) designs use various nuclear fuel types that can be significantly different than conventional light-water reactor (LWR) fuels, including differences in sizes, compositions, and chemical forms (e.g., oxide, carbide, metal). Nearly all the proposed AR fuels use high-assay low-enriched uranium (HALEU), which will have higher enrichments (5–20 wt% 235 U) than LWR fuels (currently limited to <5 wt% 235 U). In advance of the wide use of these new fuel types around the world, international safeguards organizations such as the International Atomic Energy Agency (IAEA]) are working with some of the AR vendors to formulate safeguards approaches for these AR fuel cycles. As part of the overall safeguards approach, it is important to identify the potential technical challenges in performing safeguards verification measurements of these AR fuels (both fresh and spent fuels) in advance of the widespread adoption of these new fuel types, because new safeguards technologies can take several years to develop, test, and approve for use. This report documents work performed in fiscal year 2024 based on modeling and simulation to assess the performance of the existing safeguards measurement technologies for irradiated or spent AR fuel elements or items. This work is a continuation of the work performed in fiscal year 2023 that focused on fresh AR fuels. Spent AR fuels have a distinct difference from their LWR counterparts: unlike the spent LWR fuels typically stored in a water-filled pool, some spent AR fuels—such as tristructural-isotropic (TRISO)-based fuels—will most likely be stored in air-filled hot cells. Because most safeguards measurements on spent fuel performed to date have been conducted under water, the air-filled hot cell environment could present unique challenges to safeguards measurements. Fork detector (FDET) and Cerenkov viewing device (CVD) systems have been the two primary instruments used by the IAEA for several decades to measure spent LWR fuel assemblies stored in pools for safeguards verification purposes. Because the lower refractive index of air causes Cerenkov light to be of lower intensity in air than in water, existing CVDs are likely unable to perform safeguards verification measurements for spent fuel stored in an air-filled hot cell, as is the case for the TRISO-based spent fuel elements (e.g., pebbles, graphite fuel blocks). Unlike FDET measurements, CVD measurements do not require fuel be moved, so they are a simpler and faster to take than FDET measurements. The inability to perform CVD measurements on the TRISO-based AR fuel types presents a major technical challenge in the effort to use existing technology to perform safeguards measurements on spent AR fuels. This study was mainly conducted through the modeling and simulation of an FDET or an FDET-like system on five spent AR fuel types, including one metallic fuel type and four TRISO-based fuel types in both pebble and graphite block forms in their respective storage configurations and environments. Because the various AR fuel types have significantly different dimensions, FDET systems must be adapted to accommodate them. Partial defect tests were also simulated in this study to assess the FDET’s ability to detect potential fuel diversions. The FDET measures the fuel’s total passive neutron and gamma emissions. The simulated FDET results from spent AR fuel items are compared against results from a typical spent pressurized water reactor (PWR) assembly. High-purity germanium (HPGe) gamma detector measurements were also simulated for the spent AR fuel types and the PWR assembly because the signature photopeaks have been used in LWR safeguards verifications, although HPGe is usually not used to detect diversions because of the fuel’s self-attenuation effects on those photopeaks. The results indicate that these detectors have significant challenges in performing safeguards measurements of the spent AR fuel items, including incompatibilities between AR fuel items and existing FDETs, lower neutron count rates, lower sensitivities to fuel diversions in certain AR fuel items, and significantly higher interference from a neighboring fuel item when the measurement is performed in air. These results suggest that an alternative technology or significant and timely technology development is needed to perform adequate safeguards measurements of some of these AR fuel items.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗