Search NASA⌕ Search

SEARCH · Search NASA

Results for “microgrids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Resilient Communication Scheme for Distributed Decision of Interconnecting Networks of Microgrids

Networking of microgrids can provide the operational flexibility needed for the increasing number of DERs deployed at the distribution level and supporting end-use demand when there is loss of the bulk power system. But, networked microgrids are vulnerable to cyber-physical attacks and faults due to the complex interconnections. As such, it is necessary To design resilient control systems to support the operations of networked microgrids in responses to cyber-physical attacks and faults. This paper introduces a resilient communication scheme for interconnecting multiple microgrids to support critical demand, in which the interconnection decision can be made distributedly by each microgrid controller even in the presence of cyberattacks to some communication links or microgrid controllers. This scheme blends a randomized peer-to-peer communication network for exchanging information among controllers and resilient consensus algorithms for achieving reliable interconnection agreement. The network of 6 microgrids divided from a modified 123-node test distribution feeder is used to demonstrate the effectiveness of the proposed resilient communication scheme.

Vu, Thanh Long↗

Scalable Distributed Reachability Analysis for Cyber-Physical Networked Microgrids with Communication Latency

Due to the high penetration of power-electronic-interfaced distributed energy resources (DERs), a microgrid's inertia is significantly reduced, making it sensitive to cyberand physical operational changes. When multiple microgrids are interconnected to form networked microgrids for improving system's resilience, the changes of one microgrid can quickly escalate to the overall system. In cyber-physical networked microgrids, the communication latency varies a lot. To efficiently quantify the impact of the communication latency on the dynamics of networked microgrids, a scalable distributed reachability analysis approach is presented in this paper. Reachable sets are calculated for each microgrid and then composited for the overall system dynamics evaluation. Extensive tests in the full paper will demonstrate the influence of communication latency on system dynamics and validate reachable sets can bound a system's all dynamic trajectories subject to latency changes. The test results also offer an insight into designing and managing the communication network for enhancing the system's resilience.

Li, Yan↗

Day-Ahead Forecasting with Federated LSTM to Plan Energy Sharing in a Community Microgrid

Energy balancing in microgrids is a key enabler of resilience. Community microgrids located close to each other have the added benefit of networking and sharing surplus energy, if available. Such complex decision-making runs on optimization that requires reliable short-term (up to very-short-term) forecasts of energy generation and consumption for scheduling or trading. Each microgrid may also opt to not expose their sensitive data such as consumption patterns of individual businesses or residences. This paper investigates a federated approach to dayahead forecasting that trains naive long short-term memory (LSTM) at each business in a microgrid and aggregates weights at the microgrid controller using proximal regularization. This approach ensures that the controller has access only to energy surplus/deficit and not the actual generation or consumption values, avoiding unwanted exposure of sensitive data. A community microgrid in Adjuntas, Puerto Rico with 3 businesses is selected as a case study with a laboratory-scale computing setup. A central LSTM forecaster, where sensitive data from businesses are aggregated at the controller, is implemented as a baseline for qualifying the results. This work serves as a proof-of-concept for scaling the approach to networked and nested microgrids with more complex control options.

Sundararajan, Aditya [ORNL] (ORCID:000000033577854↗

Microgrid Design Toolkit (MDT) User Guide. Software v1.3.

The Microgrid Design Toolkit (MDT) supports decision analysis for new ("greenfield") microgrid designs as well as microgrids with existing infrastructure. The current version of MDT includes two main capabilities. The first capability, the Microgrid Sizing Capability (MSC), is used to determine the size and composition of a new, grid connected microgrid in the early stages of the design process. MSC is focused on developing a microgrid that is economically viable when connected to the grid. The second capability is focused on designing a microgrid for operation in islanded mode. This second capability relies on two models: the Technology Management Optimization (TMO) model and Performance Reliability Model (PRM).

42 ENGINEERING↗

Water Microgrids: A Primer for Facility Managers

A water microgrid is similar in concept to an energy microgrid, which the U.S. Department of Energy defines as “a local energy grid with control capability, which means it can disconnect from the traditional grid and operate autonomously.” Similarly, a water microgrid is a local water system that supplies, treats, and distributes water, with the primary objective to meet mission critical water demands during a disruption of the primary supply. A water microgrid has the capability to operate independently of an existing primary water system and includes a layer of sensing capability that provides the necessary monitoring and controls to operate the water microgrid. A water microgrid may offer a viable solution for a site to address resilience gaps identified through the resilience planning process. For example, a site may not have adequate and redundant water supply to meet mission critical demands with vulnerabilities in the operating systems. A water microgrid provides the ability to island the water system from the primary water supply to satisfy water demand requirements throughout an outage or disruption.

42 ENGINEERING↗

Application of Autonomous Spacecraft Power Control Technology to Terrestrial Microgrids

This paper describes the potential of the power campus located at the NASA Glenn Research Center (GRC) in Cleveland, Ohio for microgrid development. First, the benefits provided by microgrids to the terrestrial power grid are described, and an overview of Technology Needs for microgrid development is presented. Next, GRC's work on development of autonomous control for manned deep space vehicles, which are essentially islanded microgrids, is covered, and contribution of each of these developments to the microgrid Technology Needs is detailed. Finally, a description is provided of GRC's existing physical assets which can be applied to microgrid technology development, and a phased plan for development of a microgrid test facility is presented.

Controls↗

Application of Autonomous Spacecraft Power Control Technology to Terrestrial Microgrids

This paper describes the potential of the power campus located at the NASA Glenn Research Center (GRC) in Cleveland, Ohio for microgrid development. First, the benefits provided by microgrids to the terrestrial power grid are described, and an overview of Technology Needs for microgrid development is presented. Next, GRC's work on development of autonomous control for manned deep space vehicles, which are essentially islanded microgrids, is covered, and contribution of each of these developments to the microgrid Technology Needs is detailed. Finally, a description is provided of GRC's existing physical assets which can be applied to microgrid technology development, and a phased plan for development of a microgrid test facility is presented.

Space Flight↗

Development of an integrated platform for hardware-in-the-loop evaluation of microgrids prior to site commissioning

This paper presents an integrated hardware-in-the-loop (HIL) platform for testing the operation and control of a real-world microgrid system prior to site commissioning. The proposed testing approach shows the value of setting up an integrated HIL platform to test multiple hardware devices (including the system-level controller, device controllers, and field devices). A test bed developed for the Borrego Springs community microgrid is used as an example to demonstrate the feasibility of the integrated platform. Comprehensive tests are carried out using the Borrego Springs test bed to validate the platform, meet the test objectives, and gain valuable insight prior to site commissioning. The selected test scenarios, initial conditions, events, test metrics, etc., are similar to those defined in IEEE P2030.8. The test objectives are to evaluate the microgrid controller and the operation of the microgrid. The HIL platform presented in this paper shows good value for microgrid testing in terms of its flexibility and scalability for testing various microgrids; its accuracy in its representation of the field; the comprehensiveness of the testing capability; and the efficiency of testing, which can reduce risks prior to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Small-Signal Stability Conditions for Inverter-Based Unbalanced Microgrids

The proliferation of inverter-based generation and advanced sensing, controls, and communication infrastructure have facilitated accelerated deployment of microgrids. A coordinated network of microgrids can maintain reliable power delivery to critical facilities during extreme events. Low-inertia offered by the power-electronics–interfaced energy resources, however, can present significant challenges to ensuring stable operation of the microgrids. In this work, distributed small-signal stability conditions for inverter-based microgrids are developed that involve the droop-controller parameters and the network parameters (e.g. line impedances, loads). The distributed closed-form parametric stability conditions derived in this paper can be verified in a computationally efficient manner, facilitating reliable design and operations of networks of microgrids. Dynamic phasor models have been used to capture the effects of electromagnetic transients. Furthermore, numerical results are presented, along with PSCAD simulations, to validate the analytical stability conditions. Effects of design choices, such as the conductor types, and inverter sizes, on the small-signal stability of inverter-based microgrids are investigated to derive useful engineering insights.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Engineering Microgrids Amid the Evolving Electrical Distribution System

Non-wires alternatives and microgrid technologies are maturing and present great opportunities for electric utilities to increase the benefits they offer to their customers. They have the potential to decrease the cost of resolving traditional electrical system loading issues, contribute to carbon emissions reductions, and improve the electrical distribution system’s resilience to extreme weather events. The authors of this manuscript present a review of the research on microgrids and their practical applications. This is leveraged with the past work of the authors of this manuscript and other authors to develop specific objectives for microgrids, practical criteria for engineers to consider when deploying microgrids, stochastic methods to optimize microgrid designs, and black start requirements. This guidance is then used for the design of actual networked microgrids being deployed with adaptive boundaries.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Hardware-in-the-Loop Interfaces for Inverter-Based Microgrid Experiments Including Transitions: Preprint

Microgrids continue to proliferate, particularly those that rely on inverter-based resources as the microgrid's voltage and frequency leader. Hardware-in-the-loop (HIL) simulations can de-risk microgrid deployments, and therefore we need power-hardware-in-the-loop (PHIL) interfaces for grid-forming (GFM) inverters to enable simulations of seamless transitions between islanded and grid-connected operation. Such microgrid interfaces are particularly challenging to model when the inverters need to switch modes, i.e., between grid-following (GFL) and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents two PHIL interfaces for such microgrids and the preliminary experimental results: One interface is suitable for those who have access to a power amplifier that can operate as a controllable current source, and the other is for those who need a solution that uses a voltage-mode power amplifier.

battery energy storage system↗

Voices of Experience: Microgrids for Resiliency

Modern attitudes around microgrids have evolved, from the idea that microgrids represent "grid defection" to perceiving them as a tool that utilities can use to solve challenges. One such challenge is improving resiliency. Faced with unpredictable, yet intensifying and dynamic weather and cyber risks, the value of resiliency is only growing for utility customers, regulators, and policymakers. Moreover, policymakers and regulators are increasingly asking utilities to accommodate the expansion and enhancement of such resiliency. The purpose of Voices of Experience: Microgrids for Resiliency is to guide discussions around this topic - everything from defining the many types of microgrids, to siting, ownership, control, and value streams. Utilities who participated in this project were generous with their time, insights, and examples of how they are using microgrids to solve one of their most urgent challenges: resiliency.

61 RADIATION PROTECTION AND DOSIMETRY↗

Protection schemes used in North American microgrids

This study reviewed existing conventional and nonconventional protection schemes for grid-connected and islanded mode operations in North American microgrid projects. The microgrid projects investigated in this study used different types of distributed energy resources (DERs) and integrated hydropower/diesel generators, gas/steam/wind turbines, and photovoltaic systems with energy storage. In this work, conventional protection schemes were defined as those within the IEEE Standard C37.2-2008, whereas nonconventional schemes were those not defined within this standard. The pros and cons of conventional and nonconventional protection schemes were discussed in detail. The overvoltage, undervoltage, and frequency elements were the most common conventional protection schemes applied in microgrid projects in North America. These protection elements were used to detect the islanded conditions and faults that could not be sensed by overcurrent relays because of small fault currents contributed by low-inertia DERs and power-electronic sources. Directional overcurrent elements were used to distinguish between external (grid) and internal (microgrid) faults. Adaptive protection was the most popular nonconventional protection scheme applied to the microgrid projects. In conclusion, different types of DERs and operational modes must be considered in order to address the protection and control challenges of each microgrid and to obtain the best technical and economical solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Power-Hardware-in-the-Loop (PHIL) Evaluation of Service Restoration With Networked Microgrids

This paper describes the power-hardware-in-the- loop (PHIL) evaluation of the feasibility of service restoration solutions determined by the PowerModelsONM.jl tool. This tool incorporates microgrids and the networking of microgrids into its determination of an optimal service restoration solution. The paper presents PHIL simulation results for a case study based on a real distribution feeder with multiple microgrids, showcas- ing the effectiveness of networked microgrids in aiding system restoration after an outage. The study leverages high-fidelity, real- time electromagnetic transient models to ensure accuracy in the simulation results. This work is the final output from the Resilient Operation of Networked Microgrids (RONM) project funded by the U.S. Department of Energy Office of Electricity Microgrid Program and led by Los Alamos National Laboratory. RONM focused on the application of PowerModelsONM.jl to enhance the resilience of distribution systems.

fault location isolation and service restoration (↗

Enhancing Cyber Resilience of Networked Microgrids using Vertical Federated Reinforcement Learning

This paper presents a novel federated reinforcement learning (Fed-RL) methodology to inject sufficient resiliency into the operations of the network of microgrids. We consider adversarial actions to the voltage and power control loop reference signals at the grid forming (GFM) inverters in the microgrids which are essential to integrate renewable resources. Therefore, we formulate a resilient reinforcement learning training setup that uses these adversarial injections to generate episodic trajectories and train the RL agents to alleviate their impact on performance. To circumvent the concerns about data-sharing and privacy for different owners of the microgrids in the networked setting, we bring in the aspects of the federated operation to propose novel Fed-RL algorithms. As the dynamics of each microgrid are coupled due to electrical interlinks, the conventional federated RL approaches using decoupled independent environments are not applicable, which leads us to propose a multi-agent vertically federated variation of actor-critic algorithms, namely federated soft actor-critic (FedSAC). We have performed numerical simulations on an IEEE 123-bus benchmark test feeder with three microgrids by creating a customized simulation setup by encapsulating the microgrid dynamic simulations in GridLAB-D/HELICS co-simulation platform with the OpenAI Gym environment and validated the proposed resilient and secured learning methodology.

Artificial Intelligence (AI), reinforcement learni↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

controller hardware-in-the-loop↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗