Search NASA⌕ Search

SEARCH · Search NASA

Results for “microsphere”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Microspheres for laser velocimetry in high temperature wind tunnel

The introduction of non-intrusive measurement techniques in wind tunnel experimentation has been a turning point in error free data acquisition. Laser velocimetry has been progressively implemented and utilized in various wind tunnels; e.g. subsonic, transonic, and supersonic. The success of the laser velocimeter technique is based on an accurate measurement of scattered light by seeding particles introduced into the flow stream in the wind tunnel. Therefore, application of appropriate seeding particles will affect, to a large extent the acquired data. The seeding material used depends on the type of experiment being run. Among the seeding material for subsonic tunnel are kerosene, Kaolin, and polystyrene. Polystyrene is known to be the best because of being solid particles, having high index of refraction, capable of being made both spherical and monodisperse. However for high temperature wind tunnel testing seeding material must have an additional characteristic that is high melting point. Typically metal oxide powders such as Al2O3 with melting point 3660 F are used. The metal oxides are, however polydispersed, have a high density, and a tendency to form large agglomerate that does not closely follow the flow velocity. The addition of flame phase silica to metal oxide helps to break up the agglomerates, yet still results in a narrow band of polydispersed seeding. The less desirable utility of metal oxide in high temperature wind tunnels necessitates the search for a better alternative particle seeding which this paper addresses. The Laser Velocimetry (LV) characteristic of polystyrene makes it a prime candidate as a base material in achieving the high temperature particle seeding inexpensively. While polystyrene monodisperse seeding particle reported has been successful in a subsonic wind tunnel, it lacks the high melting point and thus is not practically usable in a high temperature wind tunnel. It is well known that rise in melting point of polystyrene can be achieved by a cross-linking technique. Since polystyrene already possesses all the desired characteristics for LV, to circumvent the low melting point, a cross-linking technique was investigated.

Ghorieshi, Anthony↗

Hollow Polyimide Microspheres

A shaped article composed of an aromatic polyimide has a hollow, essentially spherical structure and a particle size of about 100 to about 1500 microns, a density of about I to about 6 pounds/ft3 and a volume change of 1 to about 20% by a pressure treatment of 30 psi for 10 minutes at room temperature. A syntactic foam, made of a multiplicity of the shaped articles which are bounded together by a matrix resin to form an integral composite structure, has a density of about 3 to about 30 pounds/cu ft and a compression strength of about 100 to about 1400 pounds/sq in.

Weiser, Erik S.↗

Hollow Polyimide Microspheres

A shaped article composed of an aromatic polyimide has a hollow, essentially spherical structure and a particle size of about 100 to about 1500 microns a density of about 1 to about 6 pounds/cubic ft and a volume change of 1 to about 20 percent by a pressure treatment of 30 psi for 10 minutes at room temperature. A syntactic foam, made of a multiplicity of the shaped articles which are bonded together by a matrix resin to form an integral composite structure, has a density of about 3 to about 30 pounds/cubic ft and a compression strength 2 of about 100 to about 1400 pounds/sq in.

Weiser, Erik S.↗

Hollow Polyimide Microspheres

A shaped article composed of an aromatic polyimide has a hollow, essentially spherical structure and a particle size of about 100 to about 1500 micrometers, a density of about 1 to about 6 pounds/cubic foot and a volume change of 1 to about 20% by a pressure treatment of 30 psi for 10 minutes at room temperature. A syntactic foam, made of a multiplicity of the shaped articles which are bonded together by a matrix resin to form an integral composite structure, has a density of about 3 to about 30 pounds/cubic feet and a compression strength of about 100 to about 1400 pounds/sq inch.

Weiser, Erik S.↗

Magnetic Microspheres for Therapeutical Applications

Hyperthermia is a well known cancer therapy and consists of heating a tumor region to the elevated temperatures in the range of 40-45 C for an extended period of time (2-8 hours). This leads to thermal inactivation of cell regulatory and growth processes with resulting widespread necrosis, carbonization and coagulation. Moreover, heat boosts the tumor response to other treatments such as radiation, chemotherapy or immunotherapy. Of particular importance is careful control of generated heat in the treated region and keeping it localized. Higher heating, to about 56 C can lead to tissue thermo-ablation. With accurate temperature control, hyperthermia has the advantage of having minimal side effects. Several heating techniques are utilized for this purpose, such as whole body hyperthermia, radio-frequency (RF) hyperthermia, ultrasound technique, inductive microwave antenna hyperthermia, inductive needles (thermoseeds), and magnetic fluid hyperthermia (MFH).MFH offers many advantages as targeting capability by applying magnets. However, this technology still suffers significant inefficiencies due to lack of thermal control. This paper will provide a review of the topic and outline the ongoing work in this area. The main emphasis is in devising ways to overcome the technical difficulty in hyperthermia therapy of achieving a uniform therapeutic temperature over the required region of the body and holding it steady. The basic obstacle of the present heating methods are non-uniform thermal properties of the tissue. Our approach is to develop a novel class of magnetic fluids which have inherent thermoregulating properties. We have identified a few magnetic alloys which can serve as a suitable nano-particle material. The objective is to synthesize, characterize and evaluate the efficacy of TRMF for hyperthermia therapy.

Mazuruk, K.↗

Magnetic Microspheres and Tissue Model Studies for Therapeutical Applications

Hyperthermia is a well known cancer therapy and consists of heating a tumor region to the elevated temperatures in the range of 40-45 C for an extended period of time (2-8 hours). This leads to thermal inactivation of cell regulatory and growth processes with resulting widespread necrosis, carbonization and coagulation. Moreover, heat boosts the tumor response to other treatments such as radiation, chemotherapy or immunotherapy. Of particular importance is careful control of generated heat in the treated region and keeping it localized. Higher heating, to about 56 C can lead to tissue thermo-ablation. With accurate temperature control, hyperthermia has the advantage of having minimal side effects. Several heating techniques are utilized for this purpose, such as whole body hyperthermia, radio-frequency (RF) hyperthermia, ultrasound technique, inductive microwave antenna hyperthermia, inductive needles (thermoseeds), and magnetic fluid hyperthermia (MFH).MFH offers many advantages as targeting capability by applying magnets. However, this technology still suffers significant inefficiencies due to lack of thermal control. This paper will provide a review of the topic and outline the ongoing work in this area. The main emphasis is in devising ways to overcome the technical difficulty in hyperthermia breast therapy of achieving a uniform therapeutic temperature over the required region of the body and holding it steady for an extended period (2-3 hours). The basic shortcomings of the presently utilized heating methods stem from the non-uniform thermal properties of the tissue and the point heating characteristics of the techniques without any thermal control. Our approach is to develop a novel class of magnetic fluids, which have inherent thermoregulating properties. We have identified a few magnetic alloys which can serve as suitable nano to micron-size particle material. The objective is to synthesize, characterize and evaluate the efficacy of Thermo Regulating Magnetic Fluids (TRMF) for hyperthermia therapy. The development of a tissue model and testing the fluid dynamics of particle motion, settling, distribution in the tissue matrix and heat generation will be discussed.

Ramachandran, N.↗

Structural and Acoustic Damping Characteristics of Polyimide Microspheres

A broad range of tests have been performed to evaluate the capability of tiny lightweight polyimide spheres to reduce sound and vibration. The types of testing includes impedance tube measurement of propagation constant, sound power insertion loss for single and double wall systems, particle frame wave characterization and beam vibration reduction. The tests were performed using spheres made of two types of polyimide and with varying diameter. Baseline results were established using common noise reduction treatment materials such as fiberglass and foam. The spheres were difficult to test due to their inherent mobility. Most tests required some adaptation to contain the spheres. One test returned obvious non-linear behavior, a result which has come to be expected for treatments of this type. The polyimide spheres are found to be a competent treatment for both sound and vibration energy with the reservation that more work needs to be done to better characterize the non-linear behavior.

Palumbo, Daniel L.↗

Experiments and Models for Polymeric Microsphere Foams

The current project was performed under the direction of Dr. Byron Pipes as its lead investigator from January 2001 to August 2004. With the permission of the NASA, the project was transferred to Dr. Thein Kyu as the principle investigator for the period of September 2004 - June 2005. There were two major thrust areas in the original proposal; (1) experimental characterization and kinematics of foam structure formation and (2) determination of the mechanical, physical, and thermal properties, although these thrust areas were further sub- divided into 7 tasks. The present project has been directed primarily to elucidate kinematics of micro-foam formation (tasks 1 and 3) and to characterize micro-foam structures, since the control of the micro-structure of these foams is of paramount importance in determining their physical, mechanical and thermal properties. The first thrust area was accomplished in a timely manner; however, the second thrust area of foam properties (tasks 2,4-7) has yet to be completed because the area of kinematics of foam structure formation turned out to be extremely complex and thus consumed more time than what have been anticipated. As will be reported in what follows, the present studies have greatly enhances the in-depth understanding of mechanisms and kinematics of the micro-foam formation from solid powders. However, in order to implement all objectives of the second thrust areas regarding investigations of mechanical, physical, and thermal properties and establishment of the correlation of structure - properties of the foams, the project needs additional time and resources. The technical highlights of the accomplishment are summarized as follows. The present study represents a first approach to understanding the complexities that act together in the powder foaming process to achieve the successful inflation of polyimide microstructures. This type of study is novel as no prior work had dissected the fundamentals that govern the inflation process in this type of systems. The systematic approach to each of the different phenomena (i.e. morphological, diffusive, kinetic and dynamic) brings into context each of them in a way that allows separate understanding and analysis. Of the different phenomena studied, probably the one that gives a higher level of control over the inflation process has been shown to be the morphological aspects of the precursor particles. It is a major contribution of the present work to isolate and identify this phenomenon and highlight the features that with careful control during the synthesis of the precursor material can lead to a highly optimized and specialized final product (neat foam or microstructure). Some of these accomplishments have been presented in various national meetings and some of which are either published in refereed journals or still in various stages of publications. One of the presentations was selected for "Best of ANTEC 2004" Online Presentation Series of the Society of Plastics Engineers (SPE) (September 2004)

Pipes, R. Byrona↗

Fiber-coupled microsphere laser

A fiber-coupled laser based on a whispering-gallery-mode resonator formed of a laser gain medium and an angle-polished fiber coupler.

Maleki, Lutfollah↗

Coupling system to a microsphere cavity

At technique for holding a resonator relative to an optical fiber at a specified distance. Structures including a rectangular indentation may be formed in the end of the optical fiber. The resonator may be placed against edges of the structures, to hold a different portion of the resonator spaced from an area where the waveguide modes will emanate.

Iltchenko, Vladimir↗

Measuring Work of Adhesion of Polystyrene Microspheres

Particle adhesion is relevant in fields ranging from aerospace and energy to civil engineering and medicine. The functions of aerodynamic surfaces, heat exchangers, solar panels, ventilation systems, and blood vessels are affected by the buildup of particulates on their surfaces. Direct measurement of the adhesive force between a particle and a surface is key to understanding and mitigating particle fouling. Approaches such as the Johnson-Kendall-Roberts (JKR) and Derjaguin-Muller-Toporov (DMT) models offer a first approximation of the forces involved but do not account for non-idealities like roughness or plastic deformation. Experimental measurements of adhesive forces often deviate significantly from predictions. One approach to measure adhesion is the colloidal probe technique, which uses a particle attached to the tip of an atomic force microscope (AFM) cantilever. The particle is touched to a surface and then withdrawn and a pull-off force (FPO) determined by cantilever deflection. FPO can be used to estimate work of adhesion (Wa) and other properties from existing models. We describe a new method for producing colloidal probes using wax as an adhesive to attach micrometer-scale spheres to AFM tips. This method can be used with a range of particles and minimizes the potential for changes to the particle surface chemistry or geometry from exposure to heat, chemicals, radiation, or external forces. Particle attachment to AFM tips is robust and reversible, allowing old particles to be replaced with new ones in a few minutes. Pull-off measurements using polystyrene (PS) particles, pristine and modified with myristyltrimethylammonium bromide (14-TAB), were collected from various substrates to demonstrate the viability of this technique and investigate the impact of particle surface modification.

Schmitz, Russell C.↗

Method of Making Dye-Doped Polystyre Microparticles

Various embodiments provide dye-doped polystyrene microspheres generated using dispersion polymerization. Polystyrene microspheres may be doped with fluorescent dyes, such as xanthene derivatives including kiton red 620 (KR620), using dispersion polymerization. Certain functionalities, such as sodium styrene sulfonate, may be used to shift the equilibrium distribution of dye molecules to favor incorporation of the dye into the particles. Polyelectrolyte materials, such as poly(diallyldimethyl ammonium chloride), PolyDADMAC, may be used to electrostatically trap and bind dye molecules within the particles. A buffer may be used to stabilize the pH change of the solution during dye-doped polystyrene microsphere generation and the buffer may be selected depending on the pKa of the dye being incorporated. The various embodiments may provide dye-doped polystyrene microspheres, such as KR620-doped polystyrene microspheres that are non-toxic and non-carcinogenic. These non-toxic and non-carcinogenic dye-doped polystyrene microspheres may be suitable for use in wind tunnel testing.

Wohl, Jr., Christopher J.↗

Design of polymeric immunomicrospheres for cell labelling and cell separation

Synthesis of several classes of hydrophylic microspheres applied to cell labeling and cell separation is described. Five classes of cross-linked microspheres with functional groups such as carboxyl, hydroxyl, amide and/or pyridine groups were synthesized. These functional groups were used to bind covalently antibodies and other proteins to the surface of the microspheres. To optimize the derivatisation technique, polyglutaraldehyde immunomicrospheres were prepared and utilized. Specific populations of human and murine lymphocytes were labelled with microspheres synthesized by the emulsion of the ionizing radiation technique. The labelling of the cells by means of microspheres containing an iron core produced successful separation of B from T lymphocytes by means of a magnetic field.

Rembaum, A.↗

Cell sorting apparatus

Polymeric functional microspheres containing metal or metal compounds are formed by addition polymerization of a covalently bondable olefinic monomer such as hydroxyethylmethacrylate in the presence of finely divided metal or metal oxide particles, such as iron, gold, platinum or magnetite, which are embedded in the resulting microspheres. The microspheres can be covalently bonded to chemotherapeutic agents, antibodies, or other proteins providing a means for labeling or separating labeled cells. Labeled cells or microspheres can be concentrated at a specific body location such as in the vicinity of a malignant tumor by applying a magnetic field to the location and then introducing the magnetically attractable microspheres or cells into the circulatory system of the subject. Labeled cells can be separated from a cell mixture by applying a predetermined magnetic field to a tube in which the mixture is flowing. After collection of the labeled cells, the magnetic field is discontinued and the labeled sub-cell population recovered.

Yen, Shiao-Ping S.↗

Method for producing a biological reagent

Polymeric functional microspheres containing metal or metal compounds are formed by addition polymerization of a covalently bondable olefinic monomer such as hydroxyethylmethacrylate in the presence of finely divided metal or metal oxide particles, such as iron, gold, platinum or magnetite, which are embedded in the resulting microspheres. The microspheres can be covalently bonded to chemotherapeutic agents, antibodies, or other proteins providing a means for labeling or separating labeled cells. Labeled cells or microspheres can be concentrated at a specific body location such as in the vicinity of a malignant tumor by applying a magnetic field to the location and then introducing the magnetically attractable microspheres or cells into the circulatory system of the subject. Labeled cells can be separated from a cell mixture by applying a predetermined magnetic field to a tube in which the mixture is flowing. After collection of the labeled cells, the magnetic field is discontinued and the labeled sub-cell population recovered.

Yen, Shiao-Ping S.↗

Bioavailability of intranasal promethazine dosage forms in dogs

Intramuscular promethazine (PMZ) is used aboard the US Space Shuttle to ameliorate symptoms of space motion sickness. Bioavailability after an oral dose of PMZ during space flight is thought to be impaired because of gastrointestinal disturbances associated with weightlessness and space motion sickness. In an attempt to find an alternative dosage form for use in space, we evaluated two intranasal (i.n.) dosage forms of PMZ in dogs for absorption and bioavailability relative to that of an equivalent intramuscular dose. Promethazine (5 mg kg-1) was administered as two intranasal dosage forms and as an intramuscular (i.m.) dose to three dogs in a randomised cross-over design. Serial blood samples were taken and analysed for PMZ concentrations and the absorption and bioavailability of PMZ were calculated for the three dosage forms. PMZ absorption from the carboxymethyl cellulose microsphere i.n. dosage form was more rapid and complete than from the myverol cubic gel formulation or from an i.m. injection. Bioavailability of the microsphere formulation was also greater than that of the gel formulation (AUC 3009 vs 1727 ng h ml-1). The bioavailability of the two i.n. dosage forms (relative to that of the i.m. injection) were 94% (microsphere) and 54% (gel). The i.n. microsphere formulation of PMZ offers great promise as an effective non-invasive alternative for treating space motion sickness due to its rapid absorption and bioavailability equivalent to the i.m. dose.

NASA Center JSC↗

Phase-Shifting Liquid Crystal Interferometers for Microgravity Fluid Physics

The initial focus of this project was to eliminate both of these problems in the Liquid Crystal Point-Diffraction Interferometer (LCPDI). Progress toward that goal will be described, along with the demonstration of a phase shifting Liquid Crystal Shearing Interferometer (LCSI) that was developed as part of this work. The latest LCPDI, other than a lens to focus the light from a test section onto a diffracting microsphere within the interferometer and a collimated laser for illumination, the pink region contained within the glass plates on the rod-mounted platform is the complete interferometer. The total width is approximately 1.5 inches with 0.25 inches on each side for bonding the electrical leads. It is 1 inch high and there are only four diffracting microspheres within the interferometer. As a result, it is very easy to align, achieving the first goal. The liquid crystal electro-optical response time is a function of layer thickness, with thinner devices switching faster due to a reduction in long-range viscoelastic forces between the LC molecules. The LCPDI has a liquid crystal layer thickness of 10 microns, which is controlled by plastic or glass microspheres embedded in epoxy 'pads' at the corners of the device. The diffracting spheres are composed of polystyrene/divinyl benzene polymer with an initial diameter of 15 microns. The spheres deform slightly when the interferometer is assembled to conform to the spacing produced by the microsphere-filled epoxy spacer pads. While the speed of this interferometer has not yet been tested, previous LCPDIs fabricated at the Laboratory for Laser Energetics switched at a rate of approximately 3.3 Hz, a factor of 10 slower than desired. We anticipate better performance when the speed of these interferometers is tested since they are approximately three times thinner. Phase shifting in these devices is a function of the AC voltage level applied to the liquid crystal. As the voltage increases, the dye in the liquid crystal tends to become more transparent, thus introducing a rather large amount of error into the phase-shifting measurement. While that error can be greatly reduced by normalization, we prefer eliminating the source of the error. To that end, we have pursued development of a 'blend' of custom dyes that will not exhibit these properties. That goal has not yet been fully achieved. Guardalben, et al, presented a similar set of interferograms in a paper partially funded by this grant. Shearing interferometers are a second class of common path interferometers. Typically they consist of a thick glass plate optimized for equal reflection from the front and back surface. While not part of the original thrust of the project, through the course of laboratory work, we demonstrated a prototype of a shearing interferometer capable of phase shifting using a commercial liquid crystal retardation plate. A schematic of this liquid crystal shearing interferometer (LCSI) and a sample set of interferograms are in the reference. This work was also supported by the U.S. Department of Energy Office of Inertial Confinement Fusion under Cooperative Agreement No. DE-FC03-92SF19460, the University of Rochester, and the New York State Energy Research and Development Authority. The support of DOE does not constitute an endorsement by DOE of the views expressed in this article. Additional information is included in the original extended abstract.

Griffin, DeVon W.↗

Home Insulation With the Stroke of a Brush

Hy-Tech Thermal Solutions, LLC, of Melbourne, Florida, is producing a very complex blend of ceramic vacuum-filled refractory products designed to minimize the path of hot air transfer through ceilings, walls, and roofs. The insulating ceramic technology blocks the transfer of heat outward when applied to paint on interior walls and ceilings, and prevents the transfer of heat inward when used to paint exterior walls and roofs, effectively providing year-round comfort in the home. As a manufacturer and marketer of thermal solutions for residential, commercial, and industrial applications, Hy-Tech Thermal Solutions attributes its success to the high performance insulating ceramic microsphere originally developed from NASA thermal research at Ames Research Center. Shaped like a hollow ball so small that it looks as if it is a single grain of flour to the naked eye (slightly thicker than a human hair), the microsphere is noncombustible and fairly chemical-resistant, and has a wall thickness about 1/10 of the sphere diameter, a compressive strength of about 4,000 pounds per square inch, and a softening point of about 1,800 C. Hy-Tech Thermal Solutions improved upon these properties by removing all of the gas inside and creating a vacuum. In effect, a 'mini thermos bottle' is produced, acting as a barrier to heat by reflecting it away from the protected surface. When these microspheres are combined with other materials, they enhance the thermal resistance of those materials. In bulk, the tiny ceramic 'beads' have the appearance of a fine talcum powder. Their inert, nontoxic properties allow them to mix easily into any type of paint, coating, adhesive, masonry, or drywall finish. Additionally, their roundness causes them to behave like ball bearings, rolling upon each other, and letting the coatings flow smoothly. When applied like paint to a wall or roof, the microsphere coating shrinks down tight and creates a dense film of the vacuum cells. The resulting ceramic layer improves fire resistance, protects from ultraviolet rays, repels insects such as termites, and shields from the destructive forces of nature.

Source record↗