Search NASA⌕ Search

SEARCH · Search NASA

Results for “microtomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Using x-ray microtomography and pore-scale modeling to quantify sediment mixing and fluid flow in a developing streambed

X-ray micro-tomography (XMT), image processing, and lattice Boltzmann (LB) methods were combined to observe sediment mixing, subsurface structure, and patterns of hydrogeological properties associated with bed sediment transport. Transport and mixing of sand and spherical glass beads were observed in a laboratory flume, beginning from a well-defined layered initial condition. Cores were obtained from the streambed at four different times, and each core was scanned by XMT in order to assess the evolution of spatial patterns within the bed. Image analysis clearly revealed the propagation of a sediment mixing front that began at the bed surface. The image data were used as boundary conditions in 3D LB simulation of pore fluid flow, showing that sediment sorting produced strong vertical gradients in permeability near the streambed surface. This new methodological approach offers potential for greatly improved characterization of mixing and transport of fine sediments in a wide variety of aquatic systems.

58 GEOSCIENCES↗

Revealing the growth kinetics of atmospheric corrosion pitting in aluminum via in situ microtomography

Abstract Understanding the mechanistic relationship between the environment, microstructure, and local kinetics of atmospheric corrosion damage remains a central challenge. To address this challenge, this study used laboratory-based X-ray tomography to directly observe attack in-operando over an extended period, enabling insights into the evolving growth kinetics and morphology of individual pits over months of exposure. Damage progression associated with nine pits in a 99.9% pure aluminum wire exposed to chloride salts in humid air was characterized. Most pits grew at a nominally linear rate up until pit death, which occurred within 12–24 h of nucleation. Exceptions to this were observed, with three pits exhibiting bimodal growth kinetics and growing for 40 or more hours. This was explained by secondary droplets that formed near the pits, increasing the cathode area. A corrosion-driven drying mechanism likely contributed to pit death in both cases. Pits first grew into the material followed by lateral expansion.

36 MATERIALS SCIENCE↗

Performance characterization of microtomography with complementary metal-oxide-semiconductor detectors for computer-aided defect inspection

We developed a computer-aided defect inspection system based on computed tomography (CT). The system consists of a homemade small cone-beam CT (CBCT) system and a graphical toolbox, which is used to extract a computer-aided design (CAD) model from the CT data. In the small CBCT system, the x-ray imaging detector is based on a complementary metal-oxide-semiconductor photodiode array in conjunction with a scintillator. Imaging performance of the detector was evaluated in terms of modulation-transfer function, noise-power spectrum, and detective quantum efficiency. The tomographic imaging performance of the small CBCT system was evaluated in terms of signal-to-noise ratio and contrast-to-noise ratio. The graphical toolbox to support defect inspection incorporates various functional tools such as volume rendering, segmentation, triangular-mesh data generation, and data reduction. All the tools have been integrated in a graphical-user interface form. The developed system can provide rapid visual inspection as well as quantitative evaluation of defects by comparing the extracted CAD file with the original file, if available, of an object. The performance of the developed system is demonstrated with experimental CT volume data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Radiation Dose Effects on Rat Bones Using Synchrotron Radiation Computed Microtomography

In this work, we investigated the consequences of irradiation in the femora and ribs of rats submitted to radiation doses of 5 Gy. Three different sites in femur specimens (head, distal metaphysis and distal epiphysis) and one in ribs (ventral) were imaged using synchrotron radiation microcomputed tomography to assess trabecular bone microarchitecture. Histomorphometric quantification was calculated directly from the 3D microtomographic images using synchrotron radiation. The 3D microtomographic images were obtained at the SYRMEP (SYnchrotron Radiation for MEdical Physics) beamline at the Elettra Synchrotron Laboratory in Trieste, Italy. A better understanding of the biological interactions that occur after exposure to photon radiation is needed in order to optimize therapeutic regimens and facilitate development and strategies that decrease radiation-induced side effects in humans. Results showed significant differences between irradiated and non-irradiated specimens, mostly in head and distal metaphysis bone sites.

60 APPLIED LIFE SCIENCES↗

Application of synchrotron radiation computed microtomography for quantification of bone microstructure in human and rat bones

This work aims to evaluate histomorphometric quantification by synchrotron radiation computed microto-mography in bones of human and rat specimens. Bones specimens are classified as normal and pathological (for human samples) and irradiated and non-irradiated samples (for rat ones). Human bones are specimens which were affected by some injury, or not. Rat bones are specimens which were irradiated, simulating radiotherapy procedures, or not. Images were obtained on SYRMEP beamline at the Elettra Synchrotron Laboratory in Trieste, Italy. The system generated 14 {mu}m tomographic images. The quantification of bone structures were performed directly by the 3D rendered images using a home-made software. Resolution yielded was excellent what facilitate quantification of bone microstructures.

60 APPLIED LIFE SCIENCES↗

X-ray microtomography and laser ablation in the analysis of ink distribution in coated paper

A novel method was developed for studying the ink-paper interface and the structural variations of a deposited layer of ink. Combining high-resolution x-ray tomography with laser ablation, the depth profile of ink (toner), i.e., its varying thickness, could be determined in a paper substrate. X-ray tomography was used to produce the 3D structure of paper with about 1 μm spatial resolution. Laser ablation combined with optical imaging was used to produce the 3D structure of the printed layer of ink on top of that paper with about 70 nm depth resolution. Ablation depth was calibrated with an optical profilometer. It can be concluded that a toner layer on a light-weight-coated paper substrate was strongly perturbed by protruding fibers of the base paper. Such fibers together with the surface topography of the base paper seem to be the major factors that control the leveling of toner and its penetration into a thinly coated paper substrate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High speed automated microtomography of nuclear emulsions and recent application

The development of high-speed automatic scanning systems was the key-factor for massive and successful emulsions application for big neutrino experiments like OPERA. The emulsion detector simplicity, the unprecedented sub-micron spatial resolution and the unique ability to provide intrinsically 3-dimensional spatial information make it a perfect device for short-living particles study, where the event topology should be precisely reconstructed in a 10-100 um scale vertex region. Recently the exceptional technological progress in image processing and automation together with intensive R&D done by Italian and Japanese microscopy groups permit to increase the scanning speed to unbelievable few years ago m{sup 2}/day scale and so greatly extend the range of the possible applications for emulsion-based detectors to other fields like: medical imaging, directional dark matter search, nuclear physics, geological and industrial applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

About a method for compressing X-ray computed microtomography data

The management of scientific data is of high importance especially for experimental techniques that produce big data volumes. Such a technique is x-ray computed tomography (CT) and its community has introduced advanced data formats which allow for better management of experimental data. Rather than the organization of the data and the associated meta-data, the main topic on this work is data compression and its applicability to experimental data collected from a synchrotron-based CT beamline at the Elettra-Sincrotrone Trieste facility (Italy) and studies images acquired from various types of samples. This study covers parallel beam geometry, but it could be easily extended to a cone-beam one. The reconstruction workflow used is the one currently in operation at the beamline. Contrary to standard image compression studies, this manuscript proposes a systematic framework and workflow for the critical examination of different compression techniques and does so by applying it to experimental data. Beyond the methodology framework, this study presents and examines the use of JPEG-XR in combination with HDF5 and TIFF formats providing insights and strategies on data compression and image quality issues that can be used and implemented at other synchrotron facilities and laboratory systems. In conclusion, projection data compression using JPEG-XR appears as a promising, efficient method to reduce data file size and thus to facilitate data handling and image reconstruction

data compression↗

Characterization of enamel caries lesions in rat molars using synchrotron X-ray microtomography

Dental caries is a ubiquitous infectious disease with a nearly 100% lifetime prevalence. Rodent caries models are widely used to investigate the etiology, progression and potential prevention or treatment of the disease. To explore the suitability of these models for deeper investigations of intact surface zones during enamel caries, the structures of early-stage carious lesions in rats were characterized and compared with previous reports on white spot enamel lesions in humans. Synchrotron X-ray microcomputed tomography non-destructively mapped demineralization in carious rat molar specimens across a range of caries severity, identifying 52 lesions across the 30 teeth imaged. Of these lesions, 13 were shown to have intact surface zones. Depth profiles of fractional mineral density were qualitatively similar to lesions in human teeth. However, the thickness of the surface zone in the rat model ranges from 10 to 58 µm, and is therefore significantly thinner than in human enamel. These results indicate that a fraction of lesions in rat caries possess an intact surface zone and are qualitatively similar to human lesions at the micrometer scale. This suggests that rat caries models may be a suitable analog through which to investigate the structure of surface zone enamel and its role during dental caries.

60 APPLIED LIFE SCIENCES↗

A new mini-triaxial cell for combined high-pressure and high-temperature in situ synchrotron X-ray microtomography experiments up to 400°C and 24 MPa

A new experimental triaxial cell for in situ synchrotron X-ray micro-computed tomography aimed at imaging small samples of (6 mm × 19 mm) at high temperatures (up to 400°C) and pressures (up to 24 MPa confining) is presented. The system has flow-through capabilities, independent axial and radial pressure control, and has been developed and tested at the 8.3.2. beamline at the Advanced Light Source. The characteristics of this new experimental rig are described, along with the challenges, mainly concerning the combination of X-ray transparency with vessel strength at high temperature, and solutions found during the development stage. An experiment involving oil shale pyrolysis under subsurface conditions, highlighting the importance of a device able to operate in this pressure and temperature range, is also introduced. Furthermore, the availability of this cell enables an unprecedented range of experiments in the Earth Sciences, with a special focus on subsurface geothermal processes.

47 OTHER INSTRUMENTATION↗