Search NASA⌕ Search

SEARCH · Search NASA

Results for “module reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Earth Observing System/Advanced Microwave Sounding Unit-A (EOS/AMSU-A): Reliability prediction report for module A1 (channels 3 through 15) and module A2 (channels 1 and 2)

This report documents the final reliability prediction performed on the Earth Observing System/Advanced Microwave Sounding Unit-A (EOS/AMSU-A). The A1 Module contains Channels 3 through 15, and is referred to herein as 'EOS/AMSU-A1'. The A2 Module contains Channels 1 and 2, and is referred herein as 'EOS/AMSU-A2'. The 'specified' figures were obtained from Aerojet Reports 8897-1 and 9116-1. The predicted reliability figure for the EOS/AMSU-A1 meets the specified value and provides a Mean Time Between Failures (MTBF) of 74,390 hours. The predicted reliability figure for the EOS/AMSU-A2 meets the specified value and provides a MTBF of 193,110 hours.

Geimer, W.↗

Thin-Film Reliability Trends Toward Improved Stability: Preprint

Long-term, stable performance of photovoltaic (PV) modules will be increasingly important to their successful penetration of the power grid. This paper summarizes more than 150 thin-film and more than 1700 silicon PV degradation rates (Rd) quoted in publications for locations worldwide. Partitioning the literature results by technology and date of installation statistical analysis shows animprovement in degradation rate especially for thin-film technologies in the last decade. A CIGS array deployed at NREL for more than 5 years that appears to be stable supports the literature trends. Indoor and outdoor data indicate undetectable change in performance (0.2+/-0.2 %/yr). One module shows signs of slight degradation from what appears to be an initial manufacturing defect, however ithas not affected the overall system performance.

14 SOLAR ENERGY↗

Development of MCAERO wing design panel method with interactive graphics module

A reliable and efficient iterative method has been developed for designing wing section contours corresponding to a prescribed subcritical pressure distribution. The design process is initialized by using MCAERO (MCAIR 3-D Subsonic Potential Flow Analysis Code) to analyze a baseline configuration. A second program DMCAERO is then used to calculate a matrix containing the partial derivative of potential at each control point with respect to each unknown geometry parameter by applying a first-order expansion to the baseline equations in MCAERO. This matrix is calculated only once but is used in each iteration cycle to calculate the geometry perturbation and to analyze the perturbed geometry. The potential on the new geometry is calculated by linear extrapolation from the baseline solution. This extrapolated potential is converted to velocity by numerical differentiation, and velocity is converted to pressure by using Bernoulli's equation. There is an interactive graphics option which allows the user to graphically display the results of the design process and to interactively change either the geometry or the prescribed pressure distribution.

Hawk, J. D.↗

Reliability and engineering of thin-film photovoltaic modules

Objectives were to: examine thin-film cell attributes that influence module performance and reliability, explore the lessons and applicability of crystalline-silicon module technology to thin-film modules, review the current status of thin-film module technologies, and identify problem areas and needed research. A major need is to separate the effects and resons for reversible degradatin from nonreversible degradation. Amorphous-silicon (a-Si) reliability investigations are focusing on exploratory research investigations, accelerated Arrhenius-type testing of a-Si cells, real-time outdoor exposure testing of a-Si cells, cell failure analysis, and failure mechanism research. Studies included the reduction in strength of glass by high temperature depositions on glass and laser scribing, encapsulation materials development needs, and the testing of modules. The new materials and processes in thin-film modules will require a delinquent reliability effort, including: establishment of mechanism-specific reliability goals; quantification of mechanism parameter dependencies; prediction of expected long-term degradation; identification of cost-effective solutions; and testing and failure analysis of trial solutions.

Royal, E. L.↗

Interconnect: Cooperative Research and Development Final Report, CRADA Number CRD-13-00507 (Project 4)

This CRADA modification involves analyses on a variety of CdTe-PV related materials, test structures, solar cells, and modules produced at FSLR and/or NLR and adds analysis related to module degradation and reliability. Materials will be provided by FSLR, NLR, and/or by interleaving FSLR and NLR layers and processes. Module reliability activities will include technical risk assessment, materials characterization, module and test structure characterization, modeling, accelerated test development, and outdoor testing.

14 SOLAR ENERGY↗

Structural Reliability Evaluation of Thermoelectric Generator Modules: Influence of End Conditions, Leg Geometry, Metallization, and Processing Temperatures

Structural reliability of thermoelectric generators (TEGs) in medium to high temperature applications still remains a challenge. Currently there are no established standards for evaluating the thermomechanical reliability of TEGs during new material and module development phases in the industry. In this work we implemented a procedure for evaluating the reliability of brittle TE materials based on the common practice in the ceramics industry. The probabilistic thermomechanical reliability of TEG couples and modules is evaluated using Weibull analysis. Finite element simulations were carried out to study the influence of TEG couple parameters such as element geometry, dimensions, spacing, metallization thickness, and processing conditions on the stresses, and the structural reliability evaluations are conducted based on the TE element stresses. We report results showed that the boundary conditions and processing temperatures have significant influence on the element and metallization stresses and overall device reliability. The external compressive load significantly enhanced structural reliability. Results also showed that among geometrical parameters the element length has a dominating influence on the element stresses compared to the leg cross-sectional shapes. The cross-section geometry of legs showed considerable effect at shorter lengths and the influence diminished with increased lengths. The proposed approach for evaluating the structural reliability could be integrated with performance optimization techniques for developing optimal and reliable TEG devices.

36 MATERIALS SCIENCE↗

Cell-level reliability testing procedures for CIGS photovoltaics

The reliability of photovoltaics is commonly studied at the module level. Many reliability problems originate from module attributes, such as metal interconnections to cells, junction boxes. However, significant work in reliability can also be done prior to module design. Testing for reliability earlier in the research cycle increases the probability of avoiding common module reliability problems before cell changes are implemented on a large scale. Cell-level reliability studies can thus lower the rates of module failures in the field and provide confidence to investors that new technologies will perform as advertised. This report summarizes how we investigated three reliability concerns in Cu(In,Ga)Se 2 (CIGS) photovoltaics at the cell level: metastability, shading-induced damage, and potential-induced degradation (PID). We find that examining these concerns required developing robust measurement protocols including the fabrication of novel testing structures. This information will allow readers to incorporate sound metrics for investigating reliability phenomena and aid their studies of cell and module reliability improvements.

14 SOLAR ENERGY↗

Design and Implementation of Automated Characterization of T-type based Power Module for PV Inverter Reliability Assessment

Reliability of power electronics holds the key for future power and energy systems since it is essential for system integration with renewables and energy storage systems. Variation of power module characteristics over the converter’s operational lifetime is a critical indicator to assess its reliability. Device characterization consists of different steps to collect, process, and visualize results, which is usually time-consuming, especially for power modules based on a non-phase-leg configuration, such as T-type circuits, widely applied for PV inverters. To reduce the time, ensure repeatability, and guarantee consistency, an automated test bench can be helpful. This paper focuses on a T-type-based power module and proposes a unique characterization platform and corresponding automation procedure and implementation. Considering the major characterization difference between T-type power modules over the conventional phase-leg power module, first, the special consideration for static characterization is highlighted. Second, the unique dynamic characterization design associated with the T-type power module is described. Finally, the automation of the power module characterization and the test platform is presented along with results and special considerations.

Siraj, Ahmed↗

Effects of Encapsulant Properties on the Thermo-Mechanical Reliability of Double-Side Cooled Power Modules for Traction Inverters

Double-side cooled power modules are being developed for next-generation traction inverters due to their better heat extraction, lower profile, and lower parasitic inductances. However, due to their rigid structure, they cause reliability concerns arising from high thermo-mechanical stresses at the interconnection joints in the module. In this work, a materials-based approach using rigid encapsulants is presented for reducing thermo-mechanical fatigue. Finite-element thermo- mechanical simulations were performed to examine the effects of the elastic modulus and coefficient of thermal expansion of epoxy- based encapsulants on the bond deformation inside a double-side cooled power module. It was found that a rigid encapsulant with a high modulus of 6.0 GPa or above and a coefficient of thermal expansion around 20 ppm/oC would improve the thermo- mechanical reliability of double-side cooled power modules by decreasing the permanent bond deformation inside the modules by 50-60%.

ADVANCED PROPULSION SYSTEMS↗

Experimental Results from Droop Compensation for the High Voltage Converter Modulators

The High Voltage Convertor Modulators are used to power the RF klystrons used throughout the linear accelerator at the Spallation Neutron Source. The output voltage of the modulator has significant voltage droop and ripple which, combined with low level RF system limitations, affect performance and stability of the accelerator cavities. In conjunction with the progress in the development of the new controller, different modulation techniques were implemented and studied on the test modulator. This paper discusses experimental results from implementation of different modulation schemes has on the modulator output voltage pulse. Thermal measurements were carried out to determine the effect of these modulations schemes on long term reliability of the modulator. Future plans are also discussed.

Accelerators↗

Automated Design-for-Reliability of a Power Electronics Module

The design of a power electronics module is a multiphysics problem and involves electrical, thermal, and reliability targets and constraints. Although the electrical and thermal design consider multiple aspects such as materials, geometry, and energy losses, reliability design is often limited to the selection of the attachment materials and electrical interconnect types. In this paper, we incorporate reliability metrics in the design phase by investigating the impact of package geometry on the thermomechanical behavior of the die-attachment material. To this end, we conducted thermal and power cycling simulations of a commercial six-pack power module with silicon carbide devices to compute junction temperature and strain energy density per cycle, respectively. We performed multiple simulations with different geometric dimensions and established a correlation between input features and output variables using subspace-based dimension reduction. The machine learning-based dimension reduction method serves as a surrogate model, which can be employed to identify the optimal module design from a thermal and reliability standpoint.

design-for-reliability↗

Advancing reliability assessments of photovoltaic modules and materials using combined-accelerated stress testing

Previously undiscovered failure modes in photovoltaic (PV) modules continue to emerge in field installations despite passing protocols for design qualification and quality assurance. Failure to detect these modes prior to widespread use could be attributed to the limitations of present-day standard accelerated stress tests (ASTs), which are primarily designed to identify known degradation or failure modes at the time of development by applying simultaneous or sequential stress factors (usually two at most). Here, we introduce an accelerated testing method known as the combined-accelerated stress test (C-AST), which simultaneously combines multiple stress factors of the natural environment. Simultaneous combination of multiple stress factors allows for improved identification of failure modes with better ability to detect modes not known a priori. A demonstration experiment was conducted that reproduced the field-observed cracking of polyamide- (PA-) and polyvinylidene fluoride (PVDF)–based backsheet films, a failure mode that was not detected by current design qualification and quality assurance testing requirements. In this work, a two-phase testing protocol was implemented. The first cycle (“Tropical”) is a predominantly high-humidity and high-temperature test designed to replicate harsh tropical climates. The second cycle (“Multi-season”) was designed to replicate drier and more temperate conditions found in continental or desert climates. Testing was conducted on 2 × 2-cell crystalline-silicon cell miniature modules constructed with both ultraviolet (UV)–transmitting and UV-blocking encapsulants. Cracking failures were observed within a cumulative 120 days of the Tropical condition for one of the PA-based backsheets and after 84 days of Tropical cycle followed by 42 days of the Multi-season cycle for the PVDF-based backsheet, which are both consistent with failures seen in fielded modules. In addition to backsheet cracking, degradation modes were observed including solder/interconnect fatigue, various light-induced degradation modes, backsheet delamination, discoloration, corrosion, and cell cracking. The ability to simultaneously apply multiple stress factors may allow many of the test sequences within the standardized design qualification procedure to be performed using a single test setup.

14 SOLAR ENERGY↗

Reliable Power Rating of Perovskite PV Modules

As the perovskite technology is ramping up into commercialization, reliable and accurate power rating of large-size perovskite modules becomes a prominent aspect for its future deployment in the PV market. It is known that the performance calibration of perovskite PV devices is very challenging due to its complex dynamic response during a conventional current-voltage (IV) measurement. PV researchers have previously proposed several steady-state performance calibration methods to reliably extract PV efficiencies, but mostly focus on small area research-type cells. In this paper, we emphasize the importance of reliable performance calibration on large-size perovskite modules. Extending the NREL Cell and Module Performance (CMP) group's steady-state performance calibration protocol (i.e., Asymptotic P MAX Scan) for perovskite cells to modules, we justify the necessity of reporting steady-state efficiencies for perovskite cells and discuss the challenges of applying this protocol to modules. We also present our protocol for Maximum Power Point Tracking (MPPT), which is a technique often used for performance calibration of perovskite cells and modules, and show a comparison between MPPT and Asymptotic P MAX . Using MPPT we demonstrate the interplay between metastability and degradation in perovskite modules, and emphasize the necessity to develop preconditioning protocols for stabilizing these devices. Our aim is to promote development of consensus protocols for performance calibration of perovskite modules, and to advance their credible power ratings, which will be beneficial to the growth of perovskite technology in the PV market.

perovskite↗