Traveling-wave Thomson scattering for electron-beam spectroscopy
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Large databases are required for “Big Data” applications in catalysis and materials science. Thermochemical databases can be created by combining data from various sources and by correcting low-fidelity datasets to higher accuracy with minimal computation. To achieve this “data fusion”, thermochemical quantities of interest, calculated at various levels of density functional theory (DFT), need to be mapped to the same, high levels of theory. In this work, a graph theoretical, statistical framework is proposed for such tasks. Subgraph frequencies are shown to provide a natural representation for learning these fusion maps. The maps are linear and are learnt with automated descriptor selection. Using a dataset of as few as ~1% from the QM9 database of 133,885 molecules, these models can predict multiple thermochemical quantities at a higher level of theory with an accuracy of 1 kcal/mol. Here, the method is explainable, generalizable, and provides a diagnostic tool for outlier identification
Explore the source record for details and available documents.
A microextraction (ME) sampling system, paired with inductively coupled plasma-mass spectrometry (ICP-MS), was employed to spatially analyze proteins tagged with lanthanum (La), gadolinium (Gd), or terbium (Tb) on the surface of western blot paper. The proteins were covalently tagged, separated via gel electrophoresis, and transferred to western blot paper for analysis by ME-ICP-MS. The ME-ICP-MS method enables the direct sampling of the tagged species on the western blot paper, without any sample preparation. Traditionally, the tagged analyte would need to be stained, excised, and digested to be analyzed by ICP-MS for its elemental and isotopic characterization. Preliminary detection limits for the ME-ICP-MS method applied to western blot paper were established to be 564, 54, and 2.5 fg for La, Gd, and Tb, respectively. The developed ME-ICP-MS method was compared to laser ablation (LA) ICP-MS, another direct solid sampling technique; it was readily determined that ME-ICP-MS can effectively map the elemental constituents on the western blot paper with comparable analysis time and measurement sensitivity. The analysis time per 2 × 4 mm extraction is ∼1 minute; if protein spots are directly targeted (rather than systematically mapping the entire blot paper), the analysis time per protein spot is ∼1 min. This developed method proved to be fast, effective, and accessible for correlating protein molecular weight with the detection of the inorganic tagant. The ME-ICP-MS approach could be widely applicable in research areas that involve metal-tagged protein bioconjugates, such as in the development of diagnostic and therapeutic agents and other biochemical probes.
In 2024, an estimated 10 million people developed Tuberculosis (TB), nearly half a million of whom were infected with drug-resistant tuberculosis (DR-TB). Early detection of infection and drug resistance enables rapid engagement in effective care. Bacterial culture and nucleic acid testing remain the primary diagnostic methods, with smear microscopy being phased out. However, these methods present significant limitations for diagnosing drug resistance, such as lengthy time-to-result for phenotypic tests, as well as the need for prior knowledge of resistance mutations and prohibitive cost for molecular tests. To address this, we developed a rapid phenotypic TB drug susceptibility test, termed Tre-DST, based on novel metabolically incorporated trehalose probes, which specifically detect live mycobacteria. We used the nonpathogenic Mycobacterium smegmatis and the virulence-attenuated Mycobacterium tuberculosis (Mtb) H37Ra or auxotrophic Mtb to demonstrate a strong correlation between cost-effective plate reader results and flow cytometry data, suggesting that the plate reader is a suitable fluorescence detector for Tre-DST. We determined that adding a 1-week incubation step allowed Mtb samples originally seeded at 10 4 CFU/mL to become detectable, over 2 weeks earlier than colony-forming unit analysis. We found that Tre-DST reports on drug susceptibility in a drug-agnostic manner, demonstrating loss of fluorescence with frontline TB drugs as well as the newer drug bedaquiline. Tre-DST distinguished RIF- and INH-resistant auxotrophs from susceptible controls and accurately reported the resistance activity. Ultimately, because Tre-DST is agnostic to mechanisms of drug resistance, this assay is likely compatible with all WHO-recommended and future DR-TB drugs as a diagnostic in reference laboratories.
Rare disease diagnostics and disease gene discovery have been revolutionized by whole-exome and genome sequencing but identifying the causative variant(s) from the millions in each individual remains challenging. The use of deep phenotyping of patients and reference genotype-phenotype knowledge, alongside variant data such as allele frequency, segregation, and predicted pathogenicity, has proved an effective strategy to tackle this issue. Here we review the numerous tools that have been developed to automate this approach and demonstrate the power of such an approach on several thousand diagnosed cases from the 100,000 Genomes Project. Finally, we discuss the challenges that need to be overcome if we are going to improve detection rates and help the majority of patients that still remain without a molecular diagnosis after state-of-the-art genomic interpretation.
Direct measurements of the slip velocity in rarefied gas flows produced by local thermodynamic non-equilibrium at the wall represent crucial information for the validation of existing theoretical and numerical models. In this work, molecular tagging velocimetry (MTV) by direct phosphorescence is applied to argon and helium flows at low pressures in a 1-mm deep channel. MTV has provided accurate measurements of the molecular displacement of the gas at average pressures of the order of 1 kPa. To the best of our knowledge, this work reports the very first flow visualizations of a gas in a confined domain and in the slip flow regime, with Knudsen numbers up to 0.014. MTV is cross-validated with mass flowrate measurements by the constant volume technique. The two diagnostic methods are applied simultaneously, and the measurements in terms of average velocity at the test section are in good agreement. Moreover, preliminary results of the slip velocity at the wall are computed from the MTV data by means of a reconstruction method
The conditions in laser-produced plasmas are frequently determined with x-ray spectroscopy by comparing calculated to measured spectra. Line spectra from K-shell transitions of low- to mid-atomic number elements are most often used since the important physical processes are well understood and reliable spectra can be readily measured and calculated. Radiation transfer effects due to large optical depths of strong lines can influence the spectra. In this work, the effects of radiation transfer on the emission spectra of short-laser pulse-heated targets are studied. The possible errors made in inferring electron temperature by not including radiation transfer are quantified. The inclusion of radiative transfer in spectral calculations improves the accuracy of typical temperature diagnostics and allows the use of strong lines for diagnostics.
Over recent years, several hypotheses have been put forward to elucidate supercritical transition states. Despite significant progress on the fundamental understanding of fluids at these supercritical conditions, important questions concerning the microstructure and dynamical processes remain. A particular research issue is hereby the fundamental understanding of the morphology of the molecular microstructure and its effect on the macroscopic behaviour and thermodynamic response functions. It is widely believed that the supercritical state is homogeneous without structural and dynamic observables to distinguish between a liquid and a vapor. However, recent investigations have identified regions of distinct liquid-like or vapor-like properties even under supercritical conditions. Specifically, it was shown that the transition between liquid-like and vapor-like states occurs across an extension to the coexistence line, marked by almost discontinuous changes in fluid properties. This transition was first identified experimentally by Nishikawa and Tanaka and stands in contrast to the classical presentation of the supercritical state space as a featureless, homogeneous domain. Structurally, the most important properties of supercritical fluids are the dynamic heterogeneities and local density fluctuations that are present within the fluid state at the microscopic level. These inhomogeneities are associated with the formation of molecular clusters of various sizes with liquid-like properties separated by voids of unbound gas-phase molecules which continuously restructure itself at picosecond timescales. By utilizing ultrafast X-ray Photon Correlation Spectroscopy (XPCS) at the Linac Coherent Light Source (LCLS) and X-ray synchrotron measurements as an experimental probe of these structural changes at the molecular level we seek to elucidate the higher-order phase transition from a liquid-like to a vapor-like state in the region extending the critical point. Open questions we seek to address particularly with XPCS are: (i) the underlying mechanisms responsible for the density fluctuations at supercritical conditions and how these dynamical processes at the molecular level affect the thermodynamic response functions and (ii) on what timescales do dynamical processes evolve that are associated with thermalization, molecular diffusion, and intermolecular cluster transfer.
Explore the source record for details and available documents.
Not Available
Coherent microwave scattering from laser-induced plasmas, including weakly ionized plasma, laser sparks, Multiphoton Ionization (MPI), and Resonance Enhanced Multi-Photon Ionizations (Radar REMPI) has achieved much successes in plasma, reactive and nonreactive flow diagnostics. Under illumination of microwaves (Radar), electrons inside the laser-induced plasma oscillate with the electric field of the microwave and re-radiate from the electrons forming coherent scattering. In the far-field approximation, the microwave scattering from the small volume plasma reflects the generation and evolution of unbounded electrons inside the plasma, when the microwave wavelength is much greater than the size of the plasma and the skin layer depth at the microwave frequency is larger than the size of the plasma. Laser excitation schemes, microwave detection methods, calibration of microwave scattering, and the novel applications of the technique have been significantly expanded and improved. Furthermore, this review paper summarizes physical principles, various REMPI excitation schemes for atomic and molecular species, and temperature measurements in plasma and reactive flows. Discussions on new research directions and applications are given at the end.
The properties of materials under extreme conditions of pressure and density are of key interest to a number of fields, including planetary geophysics, materials science, and inertial confinement fusion. In geophysics, the equations of state of planetary materials, such as hydrogen and iron, under ultrahigh pressure and density provide a better understanding of their formation and interior structure [Celliers et al., “Insulator-metal transition in dense fluid deuterium,” Science 361, 677–682 (2018) and Smith et al., “Equation of state of iron under core conditions of large rocky exoplanets,” Nat. Astron. 2, 591–682 (2018)]. The processes of interest in these fields occur under conditions of high pressure (100 GPa–100 TPa), high temperature (>3000 K), and sometimes at high strain rates (>103 s−1) depending on the process. With the advent of high energy density (HED) facilities, such as the National Ignition Facility (NIF), Linear Coherent Light Source, Omega Laser Facility, and Z, these conditions are reachable and numerous experimental platforms have been developed. To measure compression under ultrahigh pressure, stepped targets are ramp-compressed and the sound velocity, measured by the velocity interferometer system for any reflector diagnostic technique, from which the stress-density of relevant materials is deduced at pulsed power [M. D. Knudson and M. P. Desjarlais, “High-precision shock wave measurements of deuterium: Evaluation of exchange-correlation functionals at the molecular-to-atomic transition,” Phys. Rev. Lett. 118, 035501 (2017)] and laser [Smith et al., “Equation of state of iron under core conditions of large rocky exoplanets,” Nat. Astron. 2, 591–682 (2018)] facilities. To measure strength under high pressure and strain rates, experimenters measure the growth of Rayleigh–Taylor instabilities using face-on radiography [Park et al., “Grain-size-independent plastic flow at ultrahigh pressures and strain rates,” Phys. Rev. Lett. 114, 065502 (2015)]. The crystal structure of materials under high compression is measured by dynamic x-ray diffraction [Rygg et al., “X-ray diffraction at the national ignition facility,” Rev. Sci. Instrum. 91, 043902 (2020) and McBride et al., “Phase transition lowering in dynamically compressed silicon,” Nat. Phys. 15, 89–94 (2019)]. Medium range material temperatures (a few thousand degrees) can be measured by extended x-ray absorption fine structure techniques, Yaakobi et al., “Extended x-ray absorption fine structure measurements of laser-shocked V and Ti and crystal phase transformation in Ti,” Phys. Rev. Lett. 92, 095504 (2004) and Ping et al., “Solid iron compressed up to 560 GPa,” Phys. Rev. Lett. 111, 065501 (2013), whereas more extreme temperatures are measured using x-ray Thomson scattering or pyrometry. This manuscript will review the scientific motivations, experimental techniques, and the regimes that can be probed for the study of materials under extreme HED conditions.
We report ultra-high resolution mass spectrometry (UHR-MS) coupled with direct infusion (DI) electrospray ionization offers a fast solution for accurate untargeted profiling. Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometers have been shown to produce a wealth of insights into complex chemical systems because they enable unambiguous molecular formula assignment even if the vast majority of signals is of unknown identity. Inter-laboratory comparisons are required to apply this type of instrumentation in quality control (for food industry or pharmaceutics), large-scale environmental studies or clinical diagnostics. Extended comparisons employing different FT-ICR MS instruments with qualitative direct infusion analysis are scarce since the majority of detected compounds cannot be quantified. The extent to which observations can be reproduced by different laboratories remains unknown. We set up a preliminary study which encompassed a set of seventeen laboratories around the globe, diverse in instrumental characteristics and applications, to analyze the same sets of extracts from commercially available standard human blood plasma and Standard Reference Material (SRM) for blood plasma (SRM1950), which were delivered at different dilutions or spiked with different concentrations of pesticides. The aim of this study was to assess the extent to which the outputs of differently tuned FTICR mass spectrometers, with different technical specifications, are comparable for setting the frames of a future DI-FT-ICR MS ring trial. We concluded that a cluster of five laboratories, with diverse instrumental characteristics showed comparable and representative performance across all experiments, setting a reference to be used in a future ring trial on blood plasma.
Molecular imaging is a non-invasive process that enable the visualization, characterization, and quantitation of biological processes at the molecular and cellular level. With the emergence of theragnostic agents to diagnose and treat disease for personalized medicine there is a growing need for matched pairs of isotopes. Matched pairs offer the unique opportunity to obtain patient specific information from SPECT or PET diagnostic studies to quantitate in vivo function or receptor density to inform and tailor therapeutic treatment. There are several isotopes of arsenic that have emissions suitable for either or both diagnostic imaging and radiotherapy. Their half-lives are long enough to pair them with peptides and antibodies which take longer to reach maximum uptake to facilitate improved patient pharmacokinetics and dosimetry then can be obtained with shorter lived radionuclides. Arsenic-72 even offers availability from a generator that can be shipped to remote sites and thus enhances availability. Arsenic has a long history as a diagnostic agent, but until recently has suffered from limited availability, lack of suitable chelators, and concerns about toxicity have inhibited its use in nuclear medicine. However, new production methods and novel chelators are coming online and the use of radioarsenic in the pico and nanomolar scale is well below the limits associated with toxicity. This manuscript will review the production routes, separation chemistry, radiolabeling techniques and in vitro/in vivo studies of three medically relevant isotopes of arsenic (arsenic-74, arsenic-72, and arsenic-77).
This project advanced quantum algorithms, quantum information theory, strongly correlated electronic structure methods, molecular quantum materials, and exciton transport imaging in coherent condensed phase systems. Across the award period, the team developed new methods for open-quantum-system simulation, Hamiltonian learning, state tomography, reduced-density-matrix and contracted-quantum eigensolver approaches, and quantum diagnostics for device capability and openness.
Nonthermal plasma processes are promising for the modular valorization of plastic waste, especially into hydrogen and carbon materials, due to their high intensity, lack of reliance on catalysts or consumables, and suitability to be directly powered by electricity. We investigate the production of hydrogen from low-density polyethylene (LDPE) as a plastic waste model using streamer Dielectric Barrier Discharge (sDBD) plasma in nitrogen at atmospheric pressure. Here, we examine the effects of process energy density (energy input per unit of feedstock mass), feedstock mass, and plasma intensity (electric voltage) on plasma properties, hydrogen yield and energy efficiency via gas chromatography, optical emission spectroscopy, and electrical diagnostics, together with reactor-scale and nonlinear electric circuit modeling. The characteristic temperature of free electrons in the sDBD plasma is approximately 15000 K (1.3 eV), and that of gas species 10 times lower, demonstrating strong thermal non-equilibrium that can lead to molecular bond scission via charged species impact rather than direct heating. Experimental results show that higher energy density leads to greater hydrogen production and diminishing energy efficiency, and that higher plasma intensity and larger feedstock mass lead to greater hydrogen yield due to higher plasma temperatures and enhanced energy fluxes to the feedstock.
Here we present the development of an experimental platform that can collect four frames of x-ray diffraction data along a single line of sight during laser-driven, dynamic-compression experiments at the National Ignition Facility. The platform is comprised of a diagnostic imager built around ultrafast sensors with a 2-ns integration time, a custom target assembly that serves also to shield the imager, and a 10-ns duration, quasi-monochromatic x-ray source produced by laser-generated plasma. We demonstrate the performance with diffraction data for Pb ramp compressed to 150 GPa and illuminated by a Ge x-ray source that produces ∼7 × 10 11 , 10.25-keV photons/ns at the 400 μm diameter sample.