Search NASA⌕ Search

SEARCH · Search NASA

Results for “molecular spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Accurate Infrared Line Lists for 20 Isotopologues of CS 2 at Room Temperature

To facilitate atmospheric and spectroscopic studies of carbon disulfide, or CS 2 , in both planetary and exoplanetary atmospheres, we adopt the “Best Theory + Reliable High-resolution Experiment” algorithm to generate semiempirical IR line lists for the 20 most abundant CS 2 isotopologues, denoted as Ames-296K. The IR lists are computed using the Ames-1 potential energy surface, refined using the experimental transition set and an ab initio dipole moment surface fitted from CCSD(T)/aug-cc-pV(T/Q/5+d)Z dipoles extrapolated to a one-particle basis set limit. The IR lists cover the range of 0–10,000 cm -1 , with an S 296K cutoff at 10 -31 cm -1 /molecule·cm -2 (abundance included). A “natural” IR line list at 296 K includes about 10 million lines of the 20 isotopologues, with their intensities scaled by the corresponding abundances. The zero-point energy, partition functions, and abundances are reported for each isotopologue. The energy levels in the global effective Hamiltonian model for 12 C 32 S 2 are adopted to improve the line position accuracy. This new IR list for the main isotopologue is denoted as A+I.296K. Reliable HITRAN2020 line positions are also utilized to improve the accuracy of the 32 S 12 C 34 S, 32 S 12 C 33 S, and 32 S 13 C 32 S isotopologue line lists. The final composite line list is validated against Pacific Northwest National Laboratory experimental cross sections, showing excellent agreement. The agreement supports the quality of the composite line list and the power of synergy between experiment and theory. The new data are proposed for use in updating and expanding the CS 2 data in HITRAN and other high-resolution IR databases. Supplementary files are available in Zenodo and AHED.

Exoplanet atmospheric composition↗

Quantum Entanglement Molecular Absorption Spectrum Simulator

Quantum Entanglement Molecular Absorption Spectrum Simulator (QE-MASS) is a computer program for simulating two photon molecular-absorption spectroscopy using quantum-entangled photons. More specifically, QE-MASS simulates the molecular absorption of two quantum-entangled photons generated by the spontaneous parametric down-conversion (SPDC) of a fixed-frequency photon from a laser. The two-photon absorption process is modeled via a combination of rovibrational and electronic single-photon transitions, using a wave-function formalism. A two-photon absorption cross section as a function of the entanglement delay time between the two photons is computed, then subjected to a fast Fourier transform to produce an energy spectrum. The program then detects peaks in the Fourier spectrum and displays the energy levels of very short-lived intermediate quantum states (or virtual states) of the molecule. Such virtual states were only previously accessible using ultra-fast (femtosecond) laser systems. However, with the use of a single-frequency continuous wave laser to produce SPDC photons, and QEMASS program, these short-lived molecular states can now be studied using much simpler laser systems. QE-MASS can also show the dependence of the Fourier spectrum on the tuning range of the entanglement time of any externally introduced optical-path delay time. QE-MASS can be extended to any molecule for which an appropriate spectroscopic database is available. It is a means of performing an a priori parametric analysis of entangled photon spectroscopy for development and implementation of emerging quantum-spectroscopic sensing techniques. QE-MASS is currently implemented using the Mathcad software package.

Nguyen, Quang-Viet↗

Physics of molecules

Molecular physics research on maser spectroscopy, electron excitation, molecular spectra of cesium, and related topics

ATOMIC EXCITATION↗

Mosaic-Detector-Based Fluorescence Spectral Imager

A battery-powered, pen-sized, portable instrument for measuring molecular fluorescence spectra of chemical and biological samples in the field has been proposed. Molecular fluorescence spectroscopy is among the techniques used most frequently in laboratories to analyze compositions of chemical and biological samples. Heretofore, it has been possible to measure fluorescence spectra of molecular species at relative concentrations as low as parts per billion (ppb), with a few nm spectral resolution. The proposed instrument would include a planar array (mosaic) of detectors, onto which a fluorescence spectrum would be spatially mapped. Unlike in the larger laboratory-type molecular fluorescence spectrometers, mapping of wavelengths to spatial positions would be accomplished without use of relatively bulky optical parts. The proposed instrument is expected to be sensitive enough to enable measurement of spectra of chemical species at relative concentrations <1 ppb, with spectral resolution that could be tailored by design to be comparable to a laboratory molecular fluorescence spectrometer. The proposed instrument (see figure) would include a button-cell battery and a laser diode, which would generate the monochromatic ultraviolet light needed to excite fluorescence in a sample. The sample would be held in a cell bounded by far-ultraviolet-transparent quartz or optical glass. The detector array would be, more specifically, a complementary metal oxide/ semiconductor or charge-coupled- device imaging photodetector array, the photodetectors of which would be tailored to respond to light in the wavelength range of the fluorescence spectrum to be measured. The light-input face of the photodetector array would be covered with a matching checkerboard array of multilayer thin film interference filters, such that each pixel in the array would be sensitive only to light in a spectral band narrow enough so as not to overlap significantly with the band of an adjacent pixel. The wavelength interval between adjacent pixels (and, thus, the spectral resolution) would typically be chosen by design to be approximately equal to the width of the total fluorescence wavelength range of interest divided by the number of pixels. The unitary structure comprising the photodetector array overlaid with the matching filter array would be denoted a hyperspectral mosaic detector (HMD) array.

Son, Kyung-Ah↗

Free volume model for molecular weights of polymers

A free volume model has been developed for determining molecular weights of linear polymers. It is based on the size of free volume cells in two geometries of poly(arylene ether ketone)s. Free volume cell sizes in test samples were measured using positron lifetime spectroscopy. The molecular weights computed from free volume cell sizes are in good agreement with the values measured by gel permeation chromatography, with a low angle laser light scattering photometer as the detector. The model has been further tested on two atactic polystyrene samples, where it predicted the ratio of their molecular weights with reasonable accuracy.

Singh, J. J.↗

High Throughput, High Yield Fabrication of High Quantum Efficiency Back-Illuminated Photon Counting, Far UV, UV, and Visible Detector Arrays

In this paper we discuss the high throughput end-to-end post fabrication processing of high performance delta-doped and superlattice-doped silicon imagers for UV, visible, and NIR applications. As an example, we present our results on far ultraviolet and ultraviolet quantum efficiency (QE) in a photon counting, detector array. We have improved the QE by nearly an order of magnitude over microchannel plates (MCPs) that are the state-of-the-art UV detectors for many NASA space missions as well as defense applications. These achievements are made possible by precision interface band engineering of Molecular Beam Epitaxy (MBE) and Atomic Layer Deposition (ALD).

spectroscopy↗

Molecular Composition Analysis of Distant Targets

This document is the Final Report for NASA Innovative Advanced Concepts (NIAC) Phase I Grant 15-NIAC16A-0145, titled Molecular Composition Analysis of Distant Targets. The research was focused on developing a system concept for probing the molecular composition of cold solar system targets, such as Asteroids, Comets, Planets and Moons from a distant vantage, for example from a spacecraft that is orbiting the target (Hughes et al., 2015). The orbiting spacecraft is equipped with a high-power laser, which is run by electricity from photovoltaic panels. The laser is directed at a spot on the target. Materials on the surface of the target are heated by the laser beam, and begin to melt and then evaporate, forming a plume of asteroid molecules in front of the heated spot. The heated spot glows, producing blackbody illumination that is visible from the spacecraft, via a path through the evaporated plume. As the blackbody radiation from the heated spot passes through the plume of evaporated material, molecules in the plume absorb radiation in a manner that is specific to the rotational and vibrational characteristics of the specific molecules. A spectrometer aboard the spacecraft is used to observe absorption lines in the blackbody signal. The pattern of absorption can be used to estimate the molecular composition of materials in the plume, which originated on the target. Focusing on a single spot produces a borehole, and shallow subsurface profiling of the targets bulk composition is possible. At the beginning of the Phase I research, the estimated Technology Readiness Level (TRL) of the system was TRL-1. During the Phase I research, an end-to-end theoretical model of the sensor system was developed from first principles. The model includes laser energy and optical propagation, target heating, melting and evaporation of target material, plume density, thermal radiation from the heated spot, molecular cross section of likely asteroid materials, and estimation of the absorption profile at a distant spectrometer. Results obtained by executing simulations based on the model provide compelling evidence that the concept of remote laser evaporative molecular absorption spectroscopy is feasible. In this document, technical details of the model are presented, and results of simulations are described that indicate the utility of the proposed sensor system. Additionally, an asteroid rendezvous mission is analyzed, with a survey of system requirements to accomplish molecular composition analysis of the asteroid. Based on positive theoretical results obtained during Phase I, the estimated TRL of the system is now TRL-2. This document also describes potential future research and experimentation that could push the system to TRL-4 within 2 years. Steps required for construction of a laboratory prototype are described. An experiment to test predictions of the theory is described, based on the laboratory prototype setup.

asteroid↗

Rotational spectroscopy at the Jet Propulsion Laboratory

Environmental monitoring, atmospheric remote sensing and astrophysical studies promoted by NASA require a strong basis of spectroscopic information. The rotational spectroscopy capabilities at NASAs Jet Propulsion Laboratory (JPL) are currently maintained for the measurement of key mission priorities that enable modeling and retrieval of geophysical data from the atmosphere as well as validation of the space-borne instruments in the Earth Observing System, particularly the Microwave Limb Sounder. Rotational spectra are measured using a variety of spectroscopic techniques including pulsed-beam Fourier transform microwave spectroscopy (at CalTech); millimeter wavelength Stark spectroscopy; millimeter, submillimeter and THz FM spectroscopy; laser sideband spectroscopy and Fourier Transform far-infrared spectroscopy. Remote measurements of atmospheric rotational spectra are made using two limb-sounder instruments in the submillimeter and THz. Recent advances in the direct synthesis of THz radiation that enable more efficient laboratory science will be presented. Software for comprehensive and systematic study of different molecular systems is maintained at JPL, the software is freely available via http://spec.jpl.nasa.gov and is used by our group to create and sustain the JPL spectral line catalog also available online.

molecular spectroscopy↗

Collision spectroscopy. I.

Scaling law derived from small angle scattering theory, interpreting data in spectroscopic manner to deduce potentials and interactions between electronic states

ELECTRON STATE↗

Temperature gradients through EHD films and molecular alignment evidenced by infrared spectroscopy

Partial and complete emission band reversals have been observed in the infrared emission spectra from portions of operating sliding contacts. An elementary analysis has been carried out to show that partial reversals are due to temperature gradients in the fluid film - the film acts both as a radiation-emitter and absorber, and that total reversals - an emission spectrum appears as an absorption spectrum are likely to be due to a continuum source, such as hot solid asperities. The total energy radiated under the latter conditions exceeds that under the others. A decrease in gap width with increased load was accompanied by a dramatic spectral change in the case of 5P4E polyphenyl ether, which is indicative of molecular alignment.

King, V. W.↗

Walls and windows in the molecular Milky Way

Estimates are presented of the distances to the nearest CO-emitting material along 31,500 lines of sight in the northern Milky Way on the basis of an analysis of the Massachusetts-Stony Brook survey of CO emission in the first Galactic quadrant. For Galactic latitudes between -1.0 and +1.0 deg and longitudes between 8 and 53 deg, significant CO emission (greater than 1.2 K) and associated optical obscuration (greater than 1.2 mag) is found within 2 kpc of the sun in 21,149 of the lines of sight. Much of this local emission is associated with the Aquila Rift system of dark clouds. Another 8,179 lines of sight are obscured at distances between 2 and 10 kpc. The remaining 2,172 lines of sight are completely free of significant CO emission. These cloud-free positions can be used as 'offs' for radio or IR spectroscopy of molecular sources in the Galactic plane, as 'ons' for studies of the diffuse intercloud medium itself, and as possible 'windows', through which distant disk and bulge stars might be optically observable.

Waller, William H.↗

ALMA Mapping of Rapid Gas and Dust Variations in Comet C/2012 S1 (ISON): New Insights into the Origin of Cometary HNC

Observations of the sungrazing comet C/2012 S1 (ISON) were carried out using the Atacama Large Millimeter/submillimeter Array at a heliocentric distance of 0.58-0.54 AU (Astronomical Units) (pre-perihelion) on 2013 November 16-17. Temporally resolved measurements of the coma distributions of HNC, CH3OH, H2CO, and dust were obtained over the course of about an hour on each day. During the period UT 10:10-11:00 on November 16, the comet displayed a remarkable drop in activity, manifested as a greater than 42 percent decline in the molecular line and continuum fluxes. The H2CO observations are consistent with an abrupt, approximately 50 percent reduction in the cometary gas production rate soon after the start of our observations. On November 17, the total observed fluxes remained relatively constant during a similar period, but strong variations in the morphology of the HNC distribution were detected as a function of time, indicative of a clumpy, intermittent outflow for this species. Our observations suggest that at least part of the detected HNC originated from degradation of nitrogen-rich organic refractory material, released intermittently from confined regions of the nucleus. By contrast, the distributions of CH3OH and H2CO during the November 17 observations were relatively uniform, consistent with isotropic outflow and stable activity levels for these species. These results highlight a large degree of variability in the production of gas and dust from comet ISON during its pre-perihelion outburst, consistent with repeated disruption of the nucleus interspersed with periods of relative quiescence.

techniques: interferometric↗