Search NASA⌕ Search

SEARCH · Search NASA

Results for “multichannel analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A search strategy for SETI - The search for extraterrestrial intelligence

A search strategy is proposed for the detection of signals of extraterrestrial intelligent origin. It constitutes an exploration of a well defined volume of search space in the microwave region of the spectrum and envisages the use of a combination of sky survey and targeted star approaches. It is predicated on the use of existing antennas equipped with sophisticated multichannel spectrum analyzers and signal processing systems operating in the digital mode. The entire sky would be surveyed between 1 and 10 GHz with resolution bin widths down to 32 Hz. More than 700 nearby solar type stars and other selected interesting directions would be searched between 1 GHz and 3 GHz with bin widths down to 1 Hz. Particular emphasis would be placed on those solar type stars that are within 20 light years of earth.

Billingham, J.↗

A bimodal search strategy for SETI

A SETI plan has been developed jointly by the NASA Ames Research Center and the Jet Propulsion Laboratory with the objective of both observing all potential sites to some limiting equivalent isotropic radiated power and surveying with greater sensitivity a set of especially promising sites. The bimodal search strategy assumes that existing radio telescopes with state-of-the-art receivers and data processing devices will have the sensitivity to explore the vicinity of nearby stars for similar transmitters and the entire galaxy for more powerful signals. The discrete source observational mode is designed to observe 773 F, G and K-type stars within 25 pc of the sun at frequencies from 1.2 to 3 GHz and spot bands between 3 and 25 GHz with sensitivities from 10 to the -25th to 10 to the -27th W/sq m. The sky survey is intended to search the entire celestial sphere between 1.2 and 10 GHz and spot bands between 10 and 25 GHz at a sensitivity limit of approximately 10 to the -23rd times the square root of the frequency. Instrumentation for the surveys includes a large multichannel spectrum analyzer. Immediate goals of the program are the investigation of the RF background at high resolution and the development of signal detection algorithms, with operation to begin in 1984.

Gulkis, S.↗

Signal processing in SETI

It is believed that the Galaxy might contain ten billion potential life sites. In view of the physical inaccessibility of extraterrestrial life on account of the vast distances involved, a logical first step in a search for extraterrestrial intelligence (SETI) appears to be an attempt to detect signals already being radiated. The characteristics of the signals to be expected are discussed together with the search strategy of a NASA program. It is pointed out that all presently planned searches will use existing radio-astronomy antennas. If no extraterrestrial intelligence signals are discovered, society will have to decide whether SETI justifies a dedicated facility of much greater collecting area. Attention is given to a multichannel spectrum analyzer, CW signal detection, pulse detection, the pattern detector, and details of SETI system operation.

Cullers, D. K.↗

The search for extraterrestrial life: Recent developments; Proceedings of the Symposium, Boston University, MA, June 18-21, 1984

The conference presents papers on the history of the search for extraterrestrial life, the scientific rationale and methods used in the search for other planetary systems, the detection of distant planets with the Space Telescope, planetary searches using optical astrometric interferometers, and infrared spectral identification of complex organic molecules in interstellar grains. Also considered are universal protein ancestors from hydrogen cyanide and water, astronomical sources of polarized light and their role in determining molecular chirality on earth, the universal diagrams and life in the universe, the precambrian evolution of terrestrial life and a thermodynamic approach to the occurrance and appearance of galactic life forms. Papers are also presented on the Ohio Seti program, lunar reflections of terrestrial radio leakage, the multichannel spectrum analyzer, software implementation of detection algorithms for the MCSA, the Serendip II design, galactic colonization and competition in a young galactic disk, implications of ancient and future migrations, extraterrestrial intelligence, the ineviability and the possible structures of supercivilizations, planetary, interplanetary and interstellar organic matter, and universal aspects of biological evolution.

Papagiannis, M. D.↗

SETI - A more eclectic approach

NASA's proposed search for extraterrestrial intelligence (SETI) program is discussed. The receiving antennas and search strategy for SETI are described. The use of a multichannel spectrum analyzer which resolves 8 MHz of spectrum into 8 million individual channels is examined. The CW and pulse detection procedures are analyzed.

Oliver, B. M.↗

Software implementation of detection algorithms for the MCSA

The NASA Multichannel Spectrum Analyzer supplies data in several formats and in a wide range of frequency resolutions. To decide if an extraterrestrial signal is present, this data is searched using detection algorithms particularly sensitive to signals concentrated in frequency and/or time. The algorithms, whose ultimate sensitivities are determined by theoretical considerations, are also constrained by available computing power. At present, practical detection of repetitive pulses is possible at an average power about five times lower than that for incoherent CW detection. After a period of field testing, the best detection algorithms, presently implelmented in software, will be converted to hardware to increase their speed.

Cullers, D. K.↗

Satellite microwave and in situ observations of the Weddell Sea ice cover and its marginal ice zone

The radiative and physical characteristics of the Weddell Sea ice cover and its marginal ice zone are analyzed using multichannel satellite passive microwave data and ship and helicopter observations obtained during the 1983 Antarctic Marine Ecosystem Research. Winter and spring brightness temperatures are examined; spatial variability in the brightness temperatures of consolidated ice in winter and spring cyclic increases and decrease in brightness temperatures of consolidated ice with an amplitude of 50 K at 37 GHz and 20 K at 18 GHz are observed. The roles of variations in air temperature and surface characteristics in the variability of spring brightness temperatures are investigated. Ice concentrations are derived using the frequency and polarization techniques, and the data are compared with the helicopter and ship observations. Temporal changes in the ice margin structure and the mass balance of fresh water and of biological features of the marginal ice zone are studied.

Comiso, J. C.↗

Field test results with the targeted search MCSA

In April 1985, a 74,000 channel prototype of the multichannel spectrum analyzer (MCSA) that NASA plans to use in a systematic search for extraterrestrial intelligence (SETI) was installed at DSS13, a 26 meter R&D antenna facility at the Goldstone Deep Space Network (DSN) site. Since that time the instrumentation has been used to validate the performance of signal detection algorithms using locally injected signals and the weak carriers from distant spacecraft. This paper describes results from the Goldstone Field Tests and plans to move the prototype equipment to other sites where SETI may be conducted in the future.

Tarter, J. C.↗

OPAD 1991

The Optical Plume Anomaly Detection Program, an experimental study in the attempt to create a rocket engine health monitor based on detection and possible quantification of anomalous atomic and molecular species in the exhaust plume, has been in existence for several years. The instruments developed to monitor the exhaust plumes are presented. Two optical instruments are employed: the polychromator and the spectrometer. The polychromator is a 16 channel spectroradiometer having independent channels individually adjustable for center wavelength and pass bandwidth. Those values may be mechanically reset, with the aid of certain lab equipment. The spectrometer is a multichannel spectral analyzer having two 2048 element linear photodiode arrays at the exit plane of the dispersing instrument, which, like the 16 channel device, is a 1/2 meter grating spectrograph. These instruments are equipped with ultraviolet grade multifiber optical input cables, allowing the instruments to be placed in a benign environment. Telescopes mounted on the test stand observe the plume keeping the shock structure in view. The data acquisition and control system consist of four 80386-33 MHz computers: two at the test stand for instrument control and data preconditioning, and two in the test support building providing data archiving, display, and system control. Further descriptions of the instrumentation are provided.

Powers, W. T.↗

Design and Calibration of an Airborne Multichannel Swept-Tuned Spectrum Analyzer

This paper describes the design and calibration of a four-channel, airborne, swept-tuned spectrum analyzer used in two hypersonic flight experiments for characterizing dynamic data up to 25 kHz. Built mainly from commercially available analog function modules, the analyzer proved useful for an application with limited telemetry bandwidth, physical weight and volume, and electrical power. The authors discuss considerations that affect the frequency and amplitude calibrations, limitations of the design, and example flight data.

Hamory, Philip J.↗

Sensitive detection of narrowband pulses

Highly monochromatic signals, such as TV carriers, can be detected sensitively by using a narrow filter (b < or = 1 Hz) and performing power accumulation on its output. If instead a low-duty-cycle pulsed signal of the same total energy is present, the sensitivity of a square law device, followed by a thresholding operation (to eliminate most samples containing only noise), followed by the algorithm to be described, is greater by about 7 dB in typical cases. This is particularly interesting to SETI because such a pulsed signal is exactly what is sent by a rotating beacon with a directional antenna. Such a pulsed signal is, therefore, a good candidate for an extraterrestrial beacon. Software for detecting this signal type is now ready for field testing with the NASA Multichannel Spectrum Analyzer (MCSA).

NASA Discipline Number 52-60↗

A multichannel dual-mixer stability analyzer: progress report

A stability analyzer is being developed for frequency standards in JPL's Deep Space Network. Prototype hardware and software have been built. Initial tests on 100-MHz sources show an Allan deviation noise floor of about 7 X 10(sup -15) at 1 second for a dual-mixer channel.

frequency time stability dual mixer↗

Pulsed, Photonuclear-induced, Neutron Measurements of Nuclear Materials with Composite Shielding

Active measurements were performed using a 10-MeV electron accelerator with inspection objects containing various nuclear and nonnuclear materials available at the Idaho National Laboratory’s Zero Power Physics Reactor (ZPPR) facility. The inspection objects were assembled from ZPPR reactor plate materials to evaluate the measurement technologies for the characterization of plutonium, depleted uranium or highly enriched uranium shielded by both nuclear and non-nuclear materials. A series of pulsed photonuclear, time-correlated measurements were performed with unshielded calibration materials and then compared with the more complex composite shield configurations. The measurements used multiple 3He detectors that are designed to detect fission neutrons between pulses of an electron linear accelerator. The accelerator produced 10-MeV bremsstrahlung X-rays at a repetition rate of 125 Hz (8 ms between pulses) with a 4-us pulse width. All inspected objects were positioned on beam centerline and 100 cm from the X-ray source. The time-correlated data was collected in parallel using both a Los Alamos National Laboratory-designed list-mode acquisition system and a commercial multichannel scaler analyzer. A combination of different measurement configurations and data analysis methods enabled the identification of each object. This paper describes the experimental configuration, the ZPPR inspection objects used, and the various measurement and analysis results for each inspected object.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance of the Zeeman analyzer system of the McDonald Observatory 2.7 meter telescope

The paper describes a multichannel photoelectric Zeeman analyzer at the coude spectrograph of the McDonald 2.7 m reflector. A comparison of Lick and McDonald observations of HD 153882 reveals no significant difference in slopes or zero points of the two magnetic fields indicating that the systematic scale difference of 30-40% is probably instrumental in origin. Observations of the magnetic variable beta Cor Bor revealed a more nearly sinusoidal magnetic curve with less internal scatter than the photographically determined field measures of the Lick and Mauna Kea Zeeman systems. Investigation of periodicity in the secularly varying magnetic minima of beta Cor Bor did not yield evidence of previously noted periodicities other than that expected from the time structure of the data sampling.

Vogt, S. S.↗

Multichannel effects near confinement-induced resonances in harmonic waveguides

We analyze the impact of multichannel scattering in harmonic waveguides on the positions and widths of confinement-induced resonances for both isotropic and anisotropic transversal confinement. Multichannel scattering amplitudes and transmission coefficients are calculated and used to characterize the resonant behavior of atomic collisions with varying anisotropy. A mechanism is established which leads to a splitting of the confinement-induced resonance in the presence of anisotropy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

R-matrix Analysis of Reactions in the {sup 9}B Compound System

Recent activity in solving the ‘lithium problem’ in big bang nucleosynthesis has focused on the role that putative resonances may play in resonance-enhanced destruction of {sup 7}Li. Particular attention has been paid to the reactions involving the {sup 9}B compound nuclear system, d+{sup 7}Be→{sup 9}B. These reactions are analyzed via the multichannel, two-body unitary R-matrix method using the code EDA developed by Hale and collaborators. We employ much of the known elastic and reaction data, in a four-channel treatment. The data include elastic {sup 3}He+{sup 6}Li differential cross sections from 0.7 to 2.0 MeV, integrated reaction cross sections for energies from 0.7 to 5.0 MeV for {sup 6}Li({sup 3}He,p){sup 8}Be{sup *} and from 0.4 to 5.0 MeV for the {sup 6}Li({sup 3}He,d){sup 7}Be reaction. Capture data have been added to an earlier analysis with integrated cross section measurements from 0.7 to 0.825 MeV for {sup 6}Li({sup 3}He,γ){sup 9}B. The resulting resonance parameters are compared with tabulated values, and previously unidentified resonances are noted. Our results show that there are no near d+{sup 7}Be threshold resonances with widths that are 10's of keV and reduce the likelihood that a resonance-enhanced mass-7 destruction mechanism, as suggested in recently published work, can explain the {sup 7}Li problem.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct determination of lead-210 by liquid-scintillation counting

Soft betas, the internal conversion electrons, and unconverted gamma rays from lead-210 are efficiently detected in a liquid scintillation counting system with efficiency of 97 percent. The counter is interfaced with a multichannel pulse height analyzer. The spectra obtained is stored on paper tape and plotted on an x-y plotter.

Fairman, W. D.↗