Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple alignment calculation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High-speed mapping of surface charge dynamics using sparse scanning Kelvin probe force microscopy

Unraveling local dynamic charge processes is vital for progress in diverse fields, from microelectronics to energy storage. This relies on the ability to map charge carrier motion across multiple length- and timescales and understanding how these processes interact with the inherent material heterogeneities. Towards addressing this challenge, we introduce high-speed sparse scanning Kelvin probe force microscopy, which combines sparse scanning and image reconstruction. This approach is shown to enable sub-second imaging (>3 frames per second) of nanoscale charge dynamics, representing several orders of magnitude improvement over traditional Kelvin probe force microscopy imaging rates. Bridging this improved spatiotemporal resolution with macroscale device measurements, we successfully visualize electrochemically mediated diffusion of mobile surface ions on a LaAlO 3 /SrTiO 3 planar device. Such processes are known to impact band-alignment and charge-transfer dynamics at these heterointerfaces. Furthermore, we monitor the diffusion of oxygen vacancies at the single grain level in polycrystalline TiO 2 . Through temperature-dependent measurements, we identify a charge diffusion activation energy of 0.18 eV, in good agreement with previously reported values and confirmed by DFT calculations. Together, these findings highlight the effectiveness and versatility of our method in understanding ionic charge carrier motion in microelectronics or nanoscale material systems.

25 ENERGY STORAGE↗

IBR-2M Reactor Modeling with MCNP, SERPENT, CUBIT, and GIMP Computer Programs

IBR-2M is a fast research reactor located in Dubna (Russia), which operates in supercritical condition for ~800 μs every 200 ms. Two reflector parts are rotating in opposite directions generating 1.8 GWth peak power when the two parts align with the fuel zone. The reactor core uses plutonium fuel and sodium coolant. The control rods are located in stationary reflector zones. This report describes the computational modeling of the IBR-2M reactor. Two independent computational models were generated using MCNP and SERPENT computer programs. The MCNP model uses combinatorial geometry based on macro bodies, e.g. boxes, cylinders, hexagons, spheres, cones, etc., and surfaces. The SERPENT model is based on the STereo Lithographic (STL) geometry representation that is used by 3D printers. The STL geometry was constructed using the CUBIT computer program. The water cooling system of the stationary and the rotating reflectors has a very complicated geometry, involving serpentines and irregular surfaces profiles. The materials in these areas have been homogenized using the GIMP image editor according to the material distributions obtained from the colors of the design drawings. The MCNP and the SERPENT inputs consist of ~1500 and ~1750 lines, respectively. The calculated effective multiplication factors from these two Monte Carlo computer programs with different models agree within 50 pcm.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Effect of Registration Surrogate and Patient Factors on the Interobserver Variability of Electronic Portal Image Guidance During Prostate Radiotherapy

Intraprostatic fiducial markers (IPM) and electronic portal imaging (EPI) are commonly used to identify and correct for prostate motion during radiotherapy. However, little data is available on the precision of this image-guidance technique. This study quantified impact of different registration surrogates and patient factors on the interobserver variability of manual EPI alignment during prostate radiotherapy. For 50 prostate radiotherapy patients previously implanted with 3 IPM, five observers manually aligned 150 pairs of orthogonal EPI to the reference digital reconstructed radiograph using Varian Vision EPI analysis software. Images were aligned using: Bony anatomy (BA), single mid-prostate IPM (SM); and 2 strategies using 3 IPM: center of mass (COM) and rotate and translate (R and T). Intraclass correlation coefficients (ICCs) were calculated to quantify interobserver variability. The absolute displacements measured using SM and R and T were compared with those using COM. The impact of patients' pelvic diameter and adjuvant hormone therapy on interobserver variability were also evaluated. Twelve thousand displacement values were collected for analysis. The maximum discrepancy between the 5 observers was >2 mm in 47% of measurements using BA, 5% using SM, 4% using R and T, and 3% using COM. Both of the 3 IPM alignment strategies demonstrated lower interobserver variability than the single IPM strategy (ICC 0.94-0.97 vs. 0.82-0.94). BA had the highest interobserver variability (ICC = 0.43-0.90). Pelvic diameter and hormone therapy had no discernible impact on interobserver variability. Compared with COM, the absolute displacements measured using the other IPM strategies were statistically different (p < 0.001), but 95% of the absolute magnitude of differences between the strategies were {<=}1 mm. The high reproducibility among the observers demonstrated the precision of prostate localization using multiple IPM and EPI, which was not influenced by the patient factors studied. Bony anatomy displayed the highest interobserver variability of the 4 alignment, likely because of the limited EPI field-of-view. Alignment using more than one IPM is recommended to minimize interobserver variability.

61 RADIATION PROTECTION AND DOSIMETRY↗

Weight function procedure for reduced order fracture analysis of arbitrary flaws in cylindrical pressure vessels

Fracture mechanics calculations using the finite element method can be computationally expensive, which makes them challenging to use in engineering evaluations of flaws in pressure vessels. The weight function (WF) technique is a reduced order fracture modeling method that is widely used to greatly reduce these computational costs. Its computational efficiency is essential for use in probabilistic fracture mechanics evaluations of embrittled nuclear reactor pressure vessels (RPVs), due to the large number of sampled flaws that must be evaluated. Although the WF technique is general, it is typically used only for axis-aligned flaws. Recent discoveries of off-axis flaws in operating nuclear reactors have necessitated detailed simulations of such flaws and the interactions between neighboring flaws. This paper presents a generalized WF approach applicable for analyzing arbitrary flaw geometries in thick-walled cylindrical vessels, including surface-breaking and subsurface flaws, which can either axis-aligned or off-axis, and can account for interactions with other flaws. Herein, this approach is demonstrated on representative simulations of multiple flaw geometries in a RPV subjected to transient loading conditions. In all cases, the WF technique gives good comparison with benchmark results from direct simulation with greatly reduced computational effort.

42 ENGINEERING↗

Wavelength dependent photochemistry of an iron dinitrogen hydride complex via multiple spectroscopies – competing ejection of axial ligands

Nitrogenase (N 2 ase) is a critical enzyme which catalyzes the reaction of N 2 → NH 3 in nature. Studies on the spectroscopy and photochemistry of trans-[Fe II (DMeOPrPE) 2 (N 2 )H][BPh 4 ] (1) and its isotopologues (2–6) provide a possible first step to evaluate the geometries and properties of the real N 2 ase–N 2 structure(s). In this article, we have used FT-IR, FT-Raman, synchrotron-based nuclear resonant vibrational spectroscopy (NRVS) and DFT calculations to examine and assign the normal modes of these complexes. In addition, we have monitored their wavelength dependent photochemistry using mid-IR, near-IR, NRVS, and Mössbauer spectroscopies. Two distinct photolysis pathways are observed with mid-IR at (nominal) 4 K – (1) the cleavage of Fe–N 2 bond in UV or visible light photolyses, which presents a unipolar disappearance of the N 2 peak at 2094 cm −1 and is recombinable; (2) the ejection of trans hydrogen atom with UV irradiation, which has a pair of bipolar peaks with the disappearance of N 2 at 2094 cm −1 and the appearance of a new species at 2056 cm −1 and is non-recombinable. The latter peak is well aligned with the N 2 peak in an Fe I reference complex (7). The combination of mid IR monitored photolysis/recombination and NRVS monitored photolysis form the central evidence for the conclusions in this article. In particular, the Fe II –N 2 and Fe I –H·dissociations are in competition with each other in UV or UV-inclusive photolyses of this dinitrogen hydride complex. In addition, near-IR and Mössbauer also provide consistent evidence about Fe I . This wavelength dependent photochemical work is the first one on a reaction active N 2 ase–N 2 model complex and it also demonstrates the competition ejection between two axial ligands (H· and N 2 ). It offers valuable information for future studies on real N 2 ase–N 2 and its photolysis products.

Dong, Weibing [Liaoning Normal University (China)]↗

EVIDENCE FOR AN ACCRETION ORIGIN FOR THE OUTER HALO GLOBULAR CLUSTER SYSTEM OF M31

We use a sample of newly discovered globular clusters from the Pan-Andromeda Archaeological Survey (PAndAS) in combination with previously cataloged objects to map the spatial distribution of globular clusters in the M31 halo. At projected radii beyond {approx}30 kpc, where large coherent stellar streams are readily distinguished in the field, there is a striking correlation between these features and the positions of the globular clusters. Adopting a simple Monte Carlo approach, we test the significance of this association by computing the probability that it could be due to the chance alignment of globular clusters smoothly distributed in the M31 halo. We find that the likelihood of this possibility is low, below 1%, and conclude that the observed spatial coincidence between globular clusters and multiple tidal debris streams in the outer halo of M31 reflects a genuine physical association. Our results imply that the majority of the remote globular cluster system of M31 has been assembled as a consequence of the accretion of cluster-bearing satellite galaxies. This constitutes the most direct evidence to date that the outer halo globular cluster populations in some galaxies are largely accreted.

79 ASTRONOMY AND ASTROPHYSICS↗

Collapse and fragmentation of magnetic molecular cloud cores with the Enzo AMR MHD code. II. Prolate and oblate cores

We present the results of a large suite of three-dimensional models of the collapse of magnetic molecular cloud cores using the adaptive mesh refinement code Enzo2.2 in the ideal magnetohydrodynamics approximation. The cloud cores are initially either prolate or oblate, centrally condensed clouds with masses of 1.73 or 2.73 M {sub ☉}, respectively. The radial density profiles are Gaussian, with central densities 20 times higher than boundary densities. A barotropic equation of state is used to represent the transition from low density isothermal phases, to high density optically thick phases. The initial magnetic field strength ranges from 6.3 to 100 μG, corresponding to clouds that are strongly to marginally supercritical, respectively, in terms of the mass to magnetic flux ratio. The magnetic field is initially uniform and aligned with the clouds' rotation axes, with initial ratios of rotational to gravitational energy ranging from 10{sup –4} to 0.1. Two significantly different outcomes for collapse result: (1) formation of single protostars with spiral arms, and (2) fragmentation into multiple protostar systems. The transition between these two outcomes depends primarily on the initial magnetic field strength, with fragmentation occurring for mass to flux ratios greater than about 14 times the critical ratio for prolate clouds. Oblate clouds typically fragment into several times more clumps than prolate clouds. Multiple, rather than binary, system formation is the general rule in either case, suggesting that binary stars are primarily the result of the orbital dissolution of multiple protostar systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Multiple Slater Determinants and Strong Spin-Fluctuations as Key Ingredients of the Electronic Structure of Electron- and Hole-Doped Pb 10− x Cu x (PO 4 ) 6 O

LK-99, with chemical formula Pb 10−x Cu x (PO 4 ) 6 O, was recently reported to be a room-temperature superconductor. While this claim has met with little support in a flurry of ensuing work, a variety of calculations (mostly based on density-functional theory) have demonstrated that the system possesses some unusual characteristics in the electronic structure, in particular flat bands. We have established previously that within DFT, the system is insulating with many characteristics resembling the classic cuprates, provided the structure is not constrained to the P3(143) symmetry nominally assigned to it. Here we describe the basic electronic structure of LK-99 within self-consistent many-body perturbative approach, quasiparticle self-consistent GW (QSGW) approximation and their diagrammatic extensions. QSGW predicts that pristine LK-99 is indeed a Mott/charge transfer insulator, with a bandgap gap in excess of 3 eV, whether or not constrained to the P3(143) symmetry. When Pb 9 Cu(PO 4 ) 6 O is hole-doped, the valence bands modify only slightly, and a hole pocket appears. However, two solutions emerge: a high-moment solution with the Cu local moment aligned parallel to neighbors, and a low-moment solution with Cu aligned antiparallel to its environment. In the electron-doped case the conduction band structure changes significantly: states of mostly Pb character merge with the formerly dispersionless Cu d state, and high-spin and low spin solutions once again appear. Thus we conclude that with suitable doping, the ground state of the system is not adequately described by a band picture, and that strong correlations are likely. Irrespective of whether this system class hosts superconductivity or not, the transition of Pb 10 (PO 4 ) 6 O from being a band insulator to Pb 9 Cu(PO 4 ) 6 O, a Mott insulator, and multi-determinantal nature of doped Mott physics make this an extremely interesting case-study for strongly correlated many-body physics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE SPATIOKINEMATICAL STRUCTURE OF H{sub 2}O AND OH MASERS IN THE ''WATER FOUNTAIN'' SOURCE IRAS 18460-0151

Using the Very Long Baseline Array and the European Very Long Baseline Interferometry Network, we have observed 22.2 GHz H{sub 2}O and 1612 MHz OH masers in the water fountain source IRAS 18460-0151. The H{sub 2}O maser spectrum has a very wide line-of-sight velocity range ( Almost-Equal-To 310 km s{sup -1}) and consists of three groups of emission features at the blueshifted (-68 km s{sup -1}{approx}< V{sub LSR} {approx}< -17 km s{sup -1}) and redshifted (V{sub LSR} {approx_equal} 240 km s{sup -1}) edges as well as around the systemic velocity (112 km s{sup -1} {approx}< V{sub LSR} {approx}< 133 km s{sup -1}). The first two H{sub 2}O spectral components exhibit a highly collimated high-velocity bipolar jet on the sky, with an angular separation of Almost-Equal-To 120 milliarcsec (mas) (240 AU in linear length) and a three-dimensional flow velocity of Almost-Equal-To 160 km s{sup -1}. The flow dynamical age is estimated to be only Almost-Equal-To 6 yr (at the time of the observation epochs of 2006-2007). Interestingly, the systemic velocity component clearly exhibits a spherically expanding outflow with a radius of Almost-Equal-To 36 AU and a flow velocity of Almost-Equal-To 9 km s{sup -1}. On the other hand, the OH maser spectrum shows double peaks with a velocity separation of Almost-Equal-To 25 km s{sup -1} (V{sub LSR} = 111-116 and 138-141 km s{sup -1}), as typically seen in circumstellar envelopes of OH/IR stars. The angular offset between the velocity-integrated brightness peaks of the two high-velocity H{sub 2}O components is Almost-Equal-To 25 mas (50 AU). The offset direction and the alignment of the redshifted maser spots are roughly perpendicular to the axis of the H{sub 2}O maser flow. High-accuracy astrometry for the H{sub 2}O and OH masers demonstrates that the collimated fast jet and the slowly expanding outflow originate from a single or multiple sources which are located within 15 mas (30 AU). On the other hand, the estimated systemic velocity of the collimated jet (V{sub sys} Almost-Equal-To 87-113 km s{sup -1}) has a large uncertainty. This makes it difficult to provide strong constraints on models of the central stellar system of IRAS 18460-0151.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapidly Assessing the Quality of Targeted Proteomics Experiments through Monitoring Stable-Isotope Labeled Standards

Selected reaction monitoring (SRM), also known as multiple reaction monitoring (MRM), is a data acquisition technique used in targeted analysis of molecules, including targeted proteomic studies. It exploits the unique capability of triple-quadrupole (QQQ) mass spectrometers to monitor the predefined precursor and fragment ion pairs of specific molecules of interest throughout a liquid chromatography (LC) elution profile. Compared to shotgun proteomics, targeted proteomics using SRM has high selectivity, high sensitivity, and a wide linear dynamic range,(1-3) which makes it especially useful in the accurate and reproducible quantification of low-abundance proteins in highly complex biological samples. SRM has been widely used in the fields of biomarker discovery,(4-7) analysis of protein post-translational modifications(8) and characterization of biological protein networks.(4,9) In the recent years, multiple technical advances have greatly improved the throughput of SRM analyses, allowing for the quantification of hundreds of peptides in a single analysis.(6,7,10) For example, a single 800-plex SRM assay (e.g., 400 unlabeled and heavy-labeled peptide pairs and 2400 transitions with retention time scheduling) using ultrahigh-performance liquid chromatography (UHPLC) has been developed to quantify proteins in plasma.(11) Advanced labeling techniques utilizing in vitro proteome-assisted MRM for protein absolute quantification (iMPAQT) demonstrated the capability of SRM in genome-wide protein quantification of over 18?000 human proteins.(12) Moreover, the scan speed of QQQ instrumentation has been greatly improved in recent releases of commercial instrumentation. The newly developed TSQ Altis (released in 2017) can scan more than 600 transitions per second, which is 6 times more than a traditional QQQ scan speed of 100 transitions per second. The breadth of measurement enabled by these technological improvements to QQQ mass spectrometry has increased the feasibility and popularity of large scale targeted proteomics studies,(13) a major application of which will be in clinical studies in which up to hundreds of protein candidates need to be quantified in hundreds of clinical specimens.(14) Quantitative accuracy is a primary motivating factor for utilizing a targeted proteomics protocol. The precise and reproducible absolute quantification produced by SRM assays is essential to many clinical and laboratory experiments.(15,16) Because the abundance of an endogenous peptide is calculated from the measurement of the spiked-in reference standard, it is essential to assess the data quality of these references.(17) In early applications of targeted proteomics, when instrument speed greatly limited the number of transitions that could be monitored, much of this quality assessment was done manually. However, recent improvements in instrument performance and experimental design have enabled a dramatic increase in the number of target peptides and associated SRM transitions, which makes manual quality assessment an untenable and laborious task. A variety of computational tools assist in SRM experiment design and data analysis. The first task in creating an SRM experiment is the choice of proteins and representative peptides to monitor. Achieving a reliable protein abundance requires appropriately choosing peptides that have a strong signal and are free from interferences in the biological matrix. Numerous computational tools exist to facilitate assay design by identifying peptides and refining SRM transitions.(18-21) To help share these assays and eliminate time spent designing the same transitions at multiple institutions, community portals have begun to host well-designed and vetted assays.(22-24) Analyzing the experimental data requires significant computational effort to align files across replicates and experimental conditions, pick peaks and produce quantitative values, normalize data and perform statistical tests, etc.(25-27)

Gibbons, Bryson C.↗

Collective outflow from a small multiple stellar system

The formation of high-mass stars is usually accompanied by powerful protostellar outflows. Such high-mass outflows are not simply scaled-up versions of their lower-mass counterparts, since observations suggest that the collimation degree degrades with stellar mass. Theoretically, the origins of massive outflows remain open to question because radiative feedback and fragmentation of the accretion flow around the most massive stars, with M > 15 M {sub ☉}, may impede the driving of magnetic disk winds. We here present a three-dimensional simulation of the early stages of core fragmentation and massive star formation that includes a subgrid-scale model for protostellar outflows. We find that stars that form in a common accretion flow tend to have aligned outflow axes, so that the individual jets of multiple stars can combine to form a collective outflow. We compare our simulation to observations with synthetic H{sub 2} and CO observations and find that the morphology and kinematics of such a collective outflow resembles some observed massive outflows, such as Cepheus A and DR 21. We finally compare physical quantities derived from simulated observations of our models to the actual values in the models to examine the reliability of standard methods for deriving physical quantities, demonstrating that those methods indeed recover the actual values to within a factor of two to three.

79 ASTRONOMY AND ASTROPHYSICS↗

Improving the reliability of automated non-destructive inspection

In automated NDE a region of an inspected component is often interrogated several times, be it within a single data channel, across multiple channels or over the course of repeated inspections. The systematic combination of these diverse readings is recognized to provide a means to improve the reliability of the inspection, for example by enabling noise suppression. Specifically, such data fusion makes it possible to declare regions of the component defect-free to a very high probability whilst readily identifying indications. Registration, aligning input datasets to a common coordinate system, is a critical pre-computation before meaningful data fusion takes place. A novel scheme based on a multiobjective optimization is described. The developed data fusion framework, that is able to identify and rate possible indications in the dataset probabilistically, based on local data statistics, is outlined. The process is demonstrated on large data sets from the industrial ultrasonic testing of aerospace turbine disks, with major improvements in the probability of detection and probability of false call being obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EFFECTS OF FOSSIL MAGNETIC FIELDS ON CONVECTIVE CORE DYNAMOS IN A-TYPE STARS

The vigorous magnetic dynamo action achieved within the convective cores of A-type stars may be influenced by fossil magnetic fields within their radiative envelopes. We study such effects through three-dimensional simulations that model the inner 30% by radius of a 2 M {sub sun} A-type star, capturing the convective core and a portion of the overlying radiative envelope within our computational domain. We employ the three-dimensional anelastic spherical harmonic code to model turbulent dynamics within a deep rotating spherical shell. The interaction between a fossil field and the core dynamo is examined by introducing a large-scale magnetic field into the radiative envelope of a mature A star dynamo simulation. We find that the inclusion of a twisted toroidal fossil field can lead to a remarkable transition in the core dynamo behavior. Namely, a super-equipartition state can be realized in which the magnetic energy built by dynamo action is 10-fold greater than the kinetic energy of the convection itself. Such strong-field states may suggest that the resulting Lorentz forces should seek to quench the flows, yet we have achieved super-equipartition dynamo action that persists for multiple diffusion times. This is achieved by the relative co-alignment of the flows and magnetic fields in much of the domain, along with some lateral displacements of the fastest flows from the strongest fields. Convection in the presence of such strong magnetic fields typically manifests as 4-6 cylindrical rolls aligned with the rotation axis, each possessing central axial flows that imbue the rolls with a helical nature. The roll system also possesses core-crossing flows that couple distant regions of the core. We find that the magnetic fields exhibit a comparable global topology with broad, continuous swathes of magnetic field linking opposite sides of the convective core. We have explored several poloidal and toroidal fossil field geometries, finding that a poloidal component is essential for a transition to super-equipartition to occur.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-dimensional coherent spectrum of high-spin models via a quantum computing approach

Here in this work we present and benchmark a quantum computing approach to calculate the two-dimensional coherent spectrum (2DCS) of high-spin models. Our approach is based on simulating their real-time dynamics in the presence of several magnetic field pulses, which are spaced in time. We utilize the adaptive variational quantum dynamics simulation algorithm for the study due to its compact circuits, which enables simulations over sufficiently long times to achieve the required resolution in frequency space. Specifically, we consider an antiferromagnetic quantum spin model that incorporates Dzyaloshinskii-Moriya interactions and single-ion anisotropy. The obtained 2DCS spectra exhibit distinct peaks at multiples of the magnon frequency, arising from transitions between different eigenstates of the unperturbed Hamiltonian. By comparing the one-dimensional coherent spectrum with 2DCS, we demonstrate that 2DCS provides a higher resolution of the energy spectrum. We further investigate how the quantum resources scale with the magnitude of the spin using two different binary encodings of the high-spin operators: the standard binary encoding and the Gray code. At low magnetic fields both encodings require comparable quantum resources, but at larger field strengths the Gray code is advantageous. Numerical simulations for spin models with increasing number of sites indicate a polynomial system-size scaling for quantum resources. Lastly, we compare the numerical 2DCS with experimental results on a rare-earth orthoferrite system. The observed strength of the magnonic high-harmonic generation signals in the 2DCS of the quantum high-spin model aligns well with the experimental data, showing significant improvement over the corresponding mean-field results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of nodal coverage utilizing image guided radiation therapy for primary gynecologic tumor volumes

Purpose: To evaluate radiation dose delivered to pelvic lymph nodes, if daily Image Guided Radiation Therapy (IGRT) was implemented with treatment shifts based on the primary site (primary clinical target volume [CTV]). Our secondary goal was to compare dosimetric coverage with patient outcomes. Materials and methods: A total of 10 female patients with gynecologic malignancies were evaluated retrospectively after completion of definitive intensity-modulated radiation therapy (IMRT) to their pelvic lymph nodes and primary tumor site. IGRT consisted of daily kilovoltage computed tomography (CT)-on-rails imaging fused with initial planning scans for position verification. The initial plan was created using Varian's Eclipse treatment planning software. Patients were treated with a median radiation dose of 45 Gy (range: 37.5 to 50 Gy) to the primary volume and 45 Gy (range: 45 to 64.8 Gy) to nodal structures. One IGRT scan per week was randomly selected from each patient's treatment course and re-planned on the Eclipse treatment planning station. CTVs were recreated by fusion on the IGRT image series, and the patient's treatment plan was applied to the new image set to calculate delivered dose. We evaluated the minimum, maximum, and 95% dose coverage for primary and nodal structures. Reconstructed primary tumor volumes were recreated within 4.7% of initial planning volume (0.9% to 8.6%), and reconstructed nodal volumes were recreated to within 2.9% of initial planning volume (0.01% to 5.5%). Results: Dosimetric parameters averaged less than 10% (range: 1% to 9%) of the original planned dose (45 Gy) for primary and nodal volumes on all patients (n = 10). For all patients, ≥99.3% of the primary tumor volume received ≥ 95% the prescribed dose (V95%) and the average minimum dose was 96.1% of the prescribed dose. In evaluating nodal CTV coverage, ≥ 99.8% of the volume received ≥ 95% the prescribed dose and the average minimum dose was 93%. In evaluating individual IGRT sessions, we found that 6 patients had an estimated minimal nodal CTV dose less than 90% (range: 78 to 99%) of that planned. With a median follow-up of 42.5 months, 2 patients experienced systemic disease progression at an average of 19.6 months. One patient was found to have a local or regional failure with an average follow-up of 42 months. Conclusion: Using only 3 dimensional IGRT corrections in gynecological radiation allows excellent coverage of the primary target volume and good average nodal CTV coverage. If IGRT corrections are based on alignment to the primary tumor volume, and is only able to be corrected in 3 degrees, this can create situations in which nodal volumes may be under dosed. Utilizing multiple IGRT sessions appears to average out dose discrepancies over the course of treatment. The implication of underdosing in a single IGRT session needs further evaluation in future studies. Based on the concern of minimum dose to a nodal target volume, these findings may signal caution when using IGRT and IMRT in gynecological radiation patients. Possible techniques to overcome this situation may include averaging shifts between tumor and nodal volume, use of a treatment couch with 6° of freedom, deformable registration, or adaptive planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Star Block Copolymers at Homopolymer Interfaces: Conformation and Compatibilization

Star block copolymers (s-BCPs), comprised of multiple linear diblock copolymers joined at a central point, are shown to segregate to the interface between two immiscible homopolymers that are identical to the blocks of the s-BCPs. The s-BCPs undergo a configurational transition at the interface, with different blocks of copolymers being embedded in their respective homopolymers, thereby bridging the interface and promoting adhesion. A series of 4-arm s-BCPs were synthesized with hydrogenated or deuterated polystyrene (PS/dPS) as the core block and poly(2-vinylpyridine) (P2VP) as the corona block, which was directly placed at the interface between the two homopolymers. Neutron reflectivity (NR) was used to determine the concentration profiles of the PS homopolymer, s-BCP core blocks, and P2VP total segments under equilibrium. The investigation varies the molecular weight (MW) and the total number of s-BCPs at the interface. Self-consistent-field theory (SCFT) was also employed to calculate the concentration profiles of the components at the interface, which were in excellent agreement with experimental results. The NR showed that the interfacial width between the homopolymers increased with the increasing number of s-BCPs at the interface up to a saturation limit. Beyond this limit, additional s-BCPs were released into the corona-miscible phase as unimolecular micelles. For a comparable interlayer thickness of s-BCPs at the interface, lower MW s-BCPs generated a broader interface. SCFT analysis suggested that, at the same packing density, the arms of the low MW s-BCPs align more parallel to the interface, while the arms of high MW s-BCPs adopt a more normal orientation, like their linear BCP counterparts. Furthermore, it was also observed that the core blocks, constrained by the junction points, were oriented more parallel and closer to the interface than the corona blocks. The phase behavior of the polymer blends revealed that s-BCP additives can efficiently reduce the domain size, with the low MW yielding smaller domain sizes due to the greater reduction in the interfacial energy and the high MW arresting phase separation due to their higher binding energy and a jamming of the interfacial assemblies. Asymmetric double cantilever beam (ADCB) tests demonstrated that s-BCPs promoted adhesion more efficiently than their linear BCP counterparts due to stronger binding energy per molecule, suggesting a more efficient compatibilizer for polymer upcycling. In conclusion, the results from these studies provide fundamental insights into the assembly of s-BCPs at homopolymer interfaces, the reduction of domain size, and promotion of adhesion, providing a strategy for the use of s-BCPs as stealth surfactants and universal compatibilizers.

interface↗

Bifurcations, stability, and dynamics of multiple matter-wave vortex states

In the present work, we offer a unifying perspective between the dark soliton stripe and the vortex multipole (dipole, tripole, aligned quadrupole, quintopole, etc.) states that emerge in the context of quasi-two-dimensional Bose-Einstein condensates. In particular, we illustrate that the multivortex states with the vortices aligned along the (former) dark soliton stripe sequentially bifurcate from the latter state in a supercritical pitchfork manner. Each additional bifurcation adds an extra mode to the dark soliton instability and an extra vortex to the configuration; moreover, the bifurcating states inherit the stability properties of the soliton prior to the bifurcation. The critical points of this bifurcation are computed analytically via a few-mode truncation of the system, which clearly showcases the symmetry-breaking nature of the corresponding bifurcation. We complement this small(-er) amplitude, few mode bifurcation picture, with a larger amplitude, particle-based description of the ensuing vortices. The latter enables us to characterize the equilibrium position of the vortices, as well as their intrinsic dynamics and anomalous modes, thus providing a qualitative description of the nonequilibrium multivortex dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TOPOS: A new topometric patient positioning and tracking system for radiation therapy based on structured white light

Purpose: A patient positioning system for radiation therapy based on structured white light and using off-the-shelf hardware components for flexibility and cost-effectiveness has been developed in house. Increased accuracy, patient comfort, abandonment of any skin marks, accelerated workflow, objective reading/recording, better usability and robust sensor design, compared to other positioning approaches, were the main goals of this work. Another aim was the application of a 6 degrees of freedom tracking system working without dose deposition. Methods: Two optical sensors are the main parts of the TOPOS Registered-Sign system (Topometrical Positioning, cyberTECHNOLOGIES, Germany). The components: cameras, projectors, and computers are commercial off-the-shelf products, allowing for low production costs. The black/white cameras of the prototype are capable of taking up to 240 frames per second (resolution: 640 Multiplication-Sign 488 pixels). The projector has a resolution of 1024 Multiplication-Sign 768 and a refresh rate of 120 Hz. The patient's body surface is measured continuously and registered to a reference surface, providing a transformation to superimpose the patient's surface to the reference (planning CT) surface as best as possible. The execution of the calculated transformation provides the correct patient position before the treatment starts. Due to the high-speed acquisition of the surfaces, a surveillance of the patient's (respiration) motion during treatment is also accomplished. The accuracy of the system was determined using a male mannequin. Two treatment sites were evaluated: one simulating a head and neck treatment and the other simulating a thoracic wall treatment. The mannequin was moved to predefined positions, and shift vectors given by the surface registration were evaluated. Additionally manual positioning using a color-coding system was evaluated. Results: Two prototypes have been developed, each allowing a continuous high density scan of a 500 Multiplication-Sign 500 Multiplication-Sign 400 mm{sup 3} (L Multiplication-Sign W Multiplication-Sign D) large volume with a refresh rate of 10 Hz (extendible to 20 Hz for a single sensor system). Surface and position correction display, as well as respiratory motion, is shown in real-time (delay < 200 ms) using present graphical hardware acceleration. For an intuitive view of the patient's misalignment, a fast surface registration algorithm has been developed and tested and a real-time color-coding technique is proposed and verified that allows the user to easily verify the position of the patient. Using first the surface registration and then the color coding the best results were obtained: for the head and neck case, the mean difference between the actual zero position and the final match was 0.1 {+-} 0.4, -0.2 {+-} 0.7, and -0.1 {+-} 0.3 mm in vertical, longitudinal, and lateral direction. For the thoracic case, the mean differences were 0.3 {+-} 0.5, -0.6 {+-} 1.9, 0.0 {+-} 0.4 mm. Conclusions: The presented system copes with the increasing demand for more accurate patient positioning due to more precise irradiation technologies and minimizes the preparation times for correct patient alignment, therefore optimizing the treatment workflow. Moreover, TOPOS is a versatile and cost effective image guided radiation therapy device. It allows an objective rating of the patient's position before and during the irradiation and could also be used for respiratory gating or tracking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗